• 제목/요약/키워드: tensioning

검색결과 253건 처리시간 0.02초

고속철도 전차선로 고장력 실시간 모니터링 기술 구현 (Implementation Technique of Real-time Monitoring System for High-Speed Rail Contact Wire with High Tension)

  • 조용현;박영;정현진
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1256-1261
    • /
    • 2015
  • Along with the increase of railway catenary system operation speed to 400 km/h, there have been growing demands for good quality current collection systems that satisfy quality standards as well as criteria for safe working. Retaining uniform elasticity tension of contact wires is essential in maintaining high quality contact between pantograph and OCL (Overhead Contact Line) of current collection systems in high speed railways. Therefore, the tension of contact wire must be kept within tight tolerance limits in both working conditions and adverse weather conditions of catenary system. In accordance with these conditions, this paper presents a real time monitoring system for the tensioning device of the newly installed catenary system on the special route of Honam high speed line for 400 km/h operation. For the verification of the true value of tension of contact wires, we have developed ring-type tensioning sensors which were installed on supporting points of mast which compose the catenary system. According to the field test performed on the Honam high speed line catenary system, variation of tension was measured accurately in real-time.

구조의 절점 형식에 따른 형상 형성의 거동 특성 (Behavior Characteristic of Shaping Formation according to Joint Type of Structures)

  • 김진우;엄장섭;이용희
    • 한국해양공학회지
    • /
    • 제26권5호
    • /
    • pp.18-24
    • /
    • 2012
  • This paper concerned with the behaviour of shaping formation and the erection for SCST structure by cable-tensioning for three kinds of structure models. The joint types of experimental models are ball type joints, bolt type joints with gusset plates, and bolt type joints. The feasibility of the proposed shaping method and the reliability of the established geometric model were confirmed with a nonlinear finite element analysis and an experimental investigation for full size scaled pyramid test model and three kinds of SCST structure models. The characteristic of the behaviour of each joint type is shown in the shaping test for practical design purposes. As a results, the behaviour characteristics of joints is very significant in shaping analysis of space structures. So the joint type should be considered in the design and analysis of the shape formation for space structures. Also, in the special field condition, it could be a fast and economical method for constructing the space structure.

Snap back testing of unbonded post-tensioned concrete wall systems

  • Twigden, Kimberley M.;Henry, Richard S.
    • Earthquakes and Structures
    • /
    • 제16권2호
    • /
    • pp.209-219
    • /
    • 2019
  • Unbonded Post-Tensioned (UPT) precast concrete systems have been shown to provide excellent seismic resistance. In order to improve understanding of the dynamic response of UPT systems, a series of snap back tests on four UPT systems was undertaken consisting of one Single Rocking Wall (SRW) and three Precast Wall with End Columns (PreWEC) systems. The snap back tests provided both a static pushover and a nonlinear free vibration response of a system. As expected the SRW exhibited an approximate bi-linear inertia force-drift response during the free vibration decay and the PreWEC walls showed an inertia force-drift response with increased strength and energy dissipation due to the addition of steel O-connectors. All walls exhibited negligible residual drifts regardless of the number of O-connectors or the post-tensioning force. When PreWEC systems of the same strength were compared the inclusion of further energy dissipating O-connectors was found to decrease the measured peak wall acceleration. Both the local and global wall parameters measured at pseudo-static and dynamic loading rates showed similar behaviour, which demonstrates that the dynamic behaviour of UPT walls is well represented by pseudo-static tests. The SRW was found to have Equivalent Viscous Damping (EVD) between 0.9-3.8% and the three PreWEC walls were found to have maximum EVD of between 14.7-25.8%.

외적 포스트텐셔닝 강봉으로 보강된 철근콘크리트 보의 ABAQUS를 이용한 비선형해석 (Nonlinear Analysis using ABAQUS Software of Reinforced Concrete (RC) Beams Strengthened with Externally Post-tensioning Steel Rods)

  • 이수헌;신경재;김진욱;이희두
    • 대한건축학회논문집:구조계
    • /
    • 제34권2호
    • /
    • pp.11-17
    • /
    • 2018
  • Concrete is the well-used material in many architectural and civil structures. The behavior of concrete does exhibit a different characteristic in compression and tension, and it also shows an inelastic-nonlinear behavior. In addition, the concrete properties vary slightly depending on the environmental factor and manufacturer. These properties of concrete make the modeling or simulation of concrete material difficult. In reinforced concrete, particularly, there is a difficulty in bond-slip relationship between concrete and steel. However, in this paper, reserving remainder of these limits the finite element analysis for reinforced concrete beams through ABAQUS simulation has been carried out with some assumptions. Assumptions include the perfect bond of steel and concrete as well as the concrete damaged plasticity (CDP) in concrete property. There is a reasonable agreement between the experimental and numerical results, although the analytical strength and external rod deformation are slightly overestimated. The average and standard deviation between two results are 1.05 and 0.05, respectively. And the models and the computations lead to the evolution of fracture in bending beam.

긴장재 및 차량속도 변화에 따른 콘크리트 충전 타이드 아치형 거더의 동적거동 (Effects of Post-Tensioning Tendons and Vehicle Speeds on Dynamic Response of Concrete-Filled Steel Tubular Tied Arch Girder)

  • 노화성;홍상현;박경훈;이종세
    • 대한토목학회논문집
    • /
    • 제31권3A호
    • /
    • pp.163-172
    • /
    • 2011
  • CFTA 거더는 아치형상을 갖는 콘크리트 충전 강관구조이며 초기처짐 및 공용 중 응력제어를 위해 외부긴장재를 배치한 거더 형식이다. 본 연구에서는 차량진행에 따른 거더의 동적거동에 긴장재가 미치는 영향을 분석하였다. 이를 위해 유한요소 프로그램을 이용하여 거더 및 긴장재 등을 수치모델링하였으며 긴장재의 양과 긴장력을 다양한 값으로 변화시켰다. 차량하중은 도로교설계기준의 DB-24 하중을 고려하였으며 3축-2트랙으로 모델링하였다. 차량하중은 등가절점하중으로 적용시켰으며 차량하중의 이동은 차량통과 시간 및 절점수를 고려한 각 절점에서의 시간함수로 나타내었다. 차량속도는 40 km/hr에서 100 km/hr까지 20 km/hr씩 증가시켰다. 해석결과 긴장재의 긴장력 변화는 거더의 동적거동에 영향을 주지않았으며 초기처짐에만 영향을 주었다. 긴장재의 양에 따라서는 거더의 동적거동이 다르게 나타났으며 긴장재의 양이 적을수록 동적처짐은 증가하였다. 이를 바탕으로 거더의 동적증폭계수(DAF)를 산출하였으며 긴장재가 없는 경우에도 AASHTO LRFD와 도로교 표준시방서에서 정한 기준값보다 매우 작은 안정적인 거동을 보였다.

복합긴장방식이 적용된 세그멘탈 U형 거더 정적 거동 연구 (A Study of Statistic Behavior of Segmental U-shaped Prestressed Concrete Girder Applied with Integrated Tensioning Systems)

  • 장현옥;장일영
    • 한국재난정보학회 논문집
    • /
    • 제20권2호
    • /
    • pp.329-338
    • /
    • 2024
  • 연구목적: 본 연구는 긴장방식을 복합적으로 적용한 세그멘탈 PSC U형 거더에 대한 해석적 거동을 기반으로 실대형 실험체의 휨 거동 결과를 평가하여 거동의 안전성을 검증하고자 한다. 연구방법: 도로교설계기준 한계상태설계법의 사용한계 및 극한한계상태 설계 결과를 바탕으로 40m 실대형 실험체의 가력하중을 산정하고 이에 대한 4점재하방식 정적 하중재하 실험을 수행하였다. 연구결과: 설계하중, 균열하중 및 극한하중이 작용할 때 해석적 처짐값 대비 97.1%, 98.5% 그리고 79.0%에 해당하는 실험체 처짐이 발생하였다. 설계하중, 균열하중 및 극한하중이 작용할 때 균열계는 각 연결부에서 0.009~0.035mm, 0.014~0.050mm, 6.383~5.522mm로 계측되었다. 결론: 균열하중 재하시까지 실험체는 탄성적으로 거동하였고 균열발생 후 극한하중까지 변형율-경화현상을 보이며 작용하중에 대하여 휨 저항 거동이 뚜렷이 나타났음을 확인하였다. 실대형 실험체 연결부(Dry Joint) 균열은 시설물 상태평가 B등급 기준 25% 미만의 결과로써 연결부의 탄성적 거동을 확인하였고 극한하중 제거 후 최종적 잔류 변형은 0.114mm로써 세그먼트 연결부의 안정적 거동을 확인하였다.

복합긴장방식이 적용된 세그멘탈 U형 거더 동적 거동 특성 연구 (A Study of Dynamic Behavior of Segmental U-shaped Prestressed Concrete Girder Applied with Integrated Tensioning Systems)

  • 장현옥;장일영
    • 한국재난정보학회 논문집
    • /
    • 제20권2호
    • /
    • pp.369-378
    • /
    • 2024
  • 연구목적: 본 연구는 복합 긴장 방식이 적용된 세그멘탈 PSC U형 거더와 콘크리트 바닥판 슬래브가 합성된 40m 실대형 실험체를 제작하여 동적 거동 실험을 실시하고 수치해석적기법 결과와 비교 검토함으로써 구조적 안정성을 검증하고자 한다. 연구방법: 손상이 없는 실대형 실험체에 impact hammer 타격으로 동적 거동 실험을 실시하여 고유진동수와 감쇠비를 측정하고 수치해석적기법 및 구조물의 일반적인 감쇠비와 상호 비교 검토하였다. 연구결과: 거더와 슬래브 합성단면으로 구성된 수치해석 모델의 고유진동수는 2.561Hz로 계산되었고 실대형 실험체의 고유진동수는 2.670Hz로 계측되었으며 감쇠비는 0.42~0.68%로 산정되었다. 결론: 실대형 실험체 고유진동수는 수치해석 모델의 고유진동수 대비 약 4.3% 증가된 값으로써 실대형 실험체와 수치해석 모델의 질량이 동일하므로(99.97%) 실대형 실험체 강성은 구조적 안전성을 확보하였음을 도출할 수 있으며 결과적으로 실험체의 동적 거동 안정성을 검증하였다. 계측된 감쇠비 0.42~0.68%는 탄성영역의 PSC구조물 감쇠비 0.5~1.0%와 비교하여 볼 때, 안정적 동적 거동임을 확인하였다.

세그멘탈 합성보 접합부 전단 모델 시험 (Shear Modeling Tests for Post-Tensioned Composite Segmental Beams)

  • 설동재;김인규;유승룡
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.481-486
    • /
    • 2002
  • A precast concrete beam which is larger than the limits of domestic transportation regulation in weight, length, and volume is divided into three parts, transported separately, and erected with a composite beam by post-tensioning in site. Shear tests are performed on the post-tensioned composite segmental beam models with 1/2 scale. The jacking force and the ratio of area of shear key to beam section are major experimental variables. Nine shear strength are resulted from the tests with two variables. Rational equation for estimation of shear strength are obtained from the regression analysis on test results.

  • PDF

P.C 구조물 정착부의 구조 안전성 해석

  • 한석규;안세희;박종철;김두환
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1999년도 춘계 학술논문발표회 논문집
    • /
    • pp.163-168
    • /
    • 1999
  • Post-Tensioning System은 강선(Strand)을 긴장하여 콘크리트 부재에 미리 압축력을 주어 응력을 도입시키기 위한 텐던(Tendon)과 정착구(Anchorage)의 조합체계로서 이루어진다. 여기서 텐던이란 와이어, 스트랜드, 바아등의 긴장재의 하나 혹은 여러개의 묶음을 의미하며, 정착구란 긴장된 텐던에 발생된 힘을 지탱하여 그 힘을 콘크리트에 전달해 주는 기계적 장치를 말하며 콘과 Wedge로 구성된다. (중략)

  • PDF

Buckling of post-tensioned composite beams

  • Bradford, M.A.
    • Structural Engineering and Mechanics
    • /
    • 제2권1호
    • /
    • pp.113-123
    • /
    • 1994
  • A method for computing the elastic buckling prestressing force of a post-tensioned composite steel-concrete tee-beam is presented. The method is based on a virtual work formulation, and incorporates the restraint provided by the concrete slab to the buckling displacements of the steel beam. The distortional buckling solutions are shown to be given by a quadratic equation. The application of the analysis to calculation buckling strengths is given, based on codified rules for beam-columns. Conclusions are then drawn on the importance of distortional buckling when a post-tensioned composite beam is stressed during jacking.