• 제목/요약/키워드: tension sensitivity

검색결과 127건 처리시간 0.027초

텍스타일형 스트레치 센서를 이용한 스마트 축구 양말 개발 -14~15세 여중생을 중심으로- (Development of Smart Soccer Socks Using a Textile Stretch Sensor -Focused on Middle School Girls between the Ages of 14 and 15-)

  • 김지선;박진희;김주용
    • 패션비즈니스
    • /
    • 제24권3호
    • /
    • pp.17-29
    • /
    • 2020
  • This study aimed to produce fiber stretch sensors for smart soccer socks to prevent injuries during training. A sensor was manufactured with stretchable fabric and tested to ensure convenience during training. In order to manufacture the fiber stretch sensor, a CNT dispersion solution was applied to an e-band and elastic polyester fabric, and the performance of the sensors was evaluated by a tensile test. Performance evaluation showed that both of the tested fabrics are excellent for this purpose. Both sensors were attached to socks to create prototype wearable devices, and an experiment was conducted to determine whether a resistance change accompanying relaxation and contraction of the gastrocnemius muscle could be detected. In order to accurately evaluate performance as a sensor, the fabric was stretched 20 times at low speeds of 1 Hz and 0.5 Hz. A change in resistance due to tension was observed, with both the E-band and the stretchable poly fabric showing high sensitivity and high reproducibility. Both can be used as relaxation/contraction sensors. Smart soccer socks were made using the two materials, and an evaluation was conducted. Tensile tests were done on the smart soccer socks; the tests were done 20 times per sock, and the sensor showed a stable resistance change between 30 and 40 ohms depending on the tension of the sensor. As a result, we confirmed that smart soccer socks with stretch sensors made of E-bands can measure changes in the gastrocnemius muscle.

냉간단조 금형 WC-Co합금의 인장시험방법 개발 및 물성평가 (Development of Uniaxial Tensile Test Method to Evaluate Material Property of Tungsten Carbide-Cobalt Alloys for Cold Forging Dies)

  • 권인우;서영호;정기호
    • 소성∙가공
    • /
    • 제27권6호
    • /
    • pp.370-378
    • /
    • 2018
  • Cold forging, carried out at room temperature, leads to high dimensional accuracy and excellent surface integrity as compared to other forging methods such as warm and hot forgings. In the cold forging process, WC-Co (Tungsten Carbide-Cobalt) alloy is the mainly used material as a core dies because of its superior hardness and strength as compared to other structural materials. For cold forging, die life is the most significant factor because it is directly related to the manufacturing cost due to periodic die replacement in mass production. To investigate die life of WC-Co alloy for cold forging, mechanical properties such as strength and fatigue are essentially necessary. Generally, uniaxial tensile test and fatigue test are the most efficient and simplest testing method. However, uniaxial tension is not efficiently application to WC-Co alloy because of its sensitivity to alignment of the specimen due to its brittleness and difficulty in thread machining. In this study, shape of specimen, tools, and testing methods, which are appropriate for uniaxial tensile test for WC-Co alloy, are proposed. The test results such as Young's modulus, tensile strength and stress-strain curves are compared to those in previous literature to validate the proposed testing methods. Based on the validation of test results it was concluded that the newly developed testing method is applicable to other cemented carbides like Titanium carbides with high strength and brittleness, and also can be utilized to carry out fatigue tests for further investigation on die life of cold forging.

혈관평활근에 대한 Methylene Blue의 수축작용 - 가토흉부대동맥근과 돼지장간막동맥근 - (Contractile Response of Methylene Blue on Vascular Smooth Muscles - Rabbit Thoracic Aorta and Porcine Mesenteric Artery -)

  • 백영홍;최수용;김재하;조남기
    • 대한약리학회지
    • /
    • 제26권1호
    • /
    • pp.13-23
    • /
    • 1990
  • 가토흉부대동백근에서 MeB와 gentian violet는 용량-의존성 수축반응을 일으켰으나 evans blue와 eosine yellowish는 전혀 수축반응을 일으키지 못하였다. MeB는 돼지 장간막 동맥에서도 용량-의존성 수축반응을 일으켰다. 양표본에서 MeB $10^{-4}$ M의 단회투여는 수축반응에 이어 이완반응이 나타나는 양상성 반응을 일으켰으나, tyramine은 지속적인 수축반응을 일으켰다. Tyramine의 수축반응은 반복적이었으나 MeB의 그것은 일차 수축반응후 $3{\sim}5$시간후까지도 반복되지 않았다. Tyramine $10^{-4}$ M의 최대 수축반응 상태에서 MeB $10^{-4}$ M의 추가투여는 현저한 추가수축반응을 일으켰으나 반대로 MeB의 최대수축반응 상태에서 tyramine의 추가투여는 그이상의 수축반응을 일으키지 못하였다. Tyramine과 MeB 수축반응은 교감신경계 악물로 소실 또는 유의하게 억제되었다. Tyramine 수축반응은 MeB 수축보다 guanethidine과 6-hydroxydopamine에 더 예민한 반면, $Ca^{2+}-free$ PSS와 reserpine에 대하여는 MeB 수축반응이 tyramine 수축보다 더 예민하였고 prazosin하에서는 두 수축반응이 비슷하게 억제되었다. MeB 수축반응은 6-hydroxydopamine으로 유의하게 억제는 되었으나 소실되지 않았고, MeB 수축반응 관찰후에는 tyramine 뿐만아니라 6-hydroxydopamine의 수축반응도 소실되었다. 이상의 성적은 가토흉부대동맥과 돼지 장간막동맥에서 MeB 수축반응은 부분적으로 세포외 calcium 의존성이고 adrenaline성 신경발단으로부터의 norepinephrine유리에 기인하며, MeB의 norepinephrine유리 및 고갈작용이 tyramine 또는 6-hydroxydopamine의 작용보다 더 강력함을 시사하고 있다.

  • PDF

Structural health monitoring of seismically vulnerable RC frames under lateral cyclic loading

  • Chalioris, Constantin E.;Voutetaki, Maristella E.;Liolios, Angelos A.
    • Earthquakes and Structures
    • /
    • 제19권1호
    • /
    • pp.29-44
    • /
    • 2020
  • The effectiveness and the sensitivity of a Wireless impedance/Admittance Monitoring System (WiAMS) for the prompt damage diagnosis of two single-storey single-span Reinforced Concrete (RC) frames under cyclic loading is experimentally investigated. The geometrical and the reinforcement characteristics of the RC structural members of the frames represent typical old RC frame structure without consideration of seismic design criteria. The columns of the frames are vulnerable to shear failure under lateral load due to their low height-to-depth ratio and insufficient transverse reinforcement. The proposed Structural Health Monitoring (SHM) system comprises of specially manufactured autonomous portable devices that acquire the in-situ voltage frequency responses of a network of twenty piezoelectric transducers mounted to the RC frames. Measurements of external and internal small-sized piezoelectric patches are utilized for damage localization and assessment at various and increased damage levels as the magnitude of the imposed lateral cycle deformations increases. A bare RC frame and a strengthened one using a pair of steel crossed tension-ties (X-bracing) have been tested in order to check the sensitivity of the developed WiAMS in different structural conditions since crack propagation, damage locations and failure mode of the examined frames vary. Indeed, the imposed loading caused brittle shear failure to the column of the bare frame and the formation of plastic hinges at the beam ends of the X-braced frame. Test results highlighted the ability of the proposed SHM to identify incipient damages due to concrete cracking and steel yielding since promising early indication of the forthcoming critical failures before any visible sign has been obtained.

The Impact of Deflection on the Sensing Response of Fiber Bragg Gratings Bonded to Graphene and PMMA Substrates

  • Salih, Younis Mohammed;Ameen, Mudhaffer Mustafa;Muhammadsharif, Fahmi F.;Ahmad, Mohammad Fadhli;Mokhtar, Nor Aieni Haji;Saeed, Ismael Mohammed Mohammed;Siddique, Md Nurul Islam;Dagang, Ahmad Nazri;Rahman, Salisa Abdul;Latiff, Nurul Adilah Abdul;Ismail, Abd Khamim
    • Current Optics and Photonics
    • /
    • 제4권2호
    • /
    • pp.95-102
    • /
    • 2020
  • The impact of graphene and poly(methyl methacrylate) (PMMA) substrates on the response of a fiber Bragg grating (FBG) due to mechanical deflection was investigated. For this purpose, four FBGs with grating lengths of 5, 15, 25, and 35.9 mm were utilized. Higher sensitivity was found for FBGs of larger grating length and for those bonded to graphene substrate. It was concluded that FBGs of smaller grating length (5 and 15 mm) were more sensitive in compression mode, while those of larger grating length (25 and 35.9 mm) were seen to be highly sensitive in tension mode.

C. M. I에 의한 갱년기 여성의 신체 및 정신건강 평가 (Evaluation of the Mental and Physical Health Status of Women in the Involutions period using the Cornell Medical Index)

  • 최명성
    • 대한간호학회지
    • /
    • 제7권1호
    • /
    • pp.73-79
    • /
    • 1977
  • This study was carried on between June first and July thirty-first 1976 using as subjects women living in the areas of Pusan, Kyoung Sang Buk Do and Kyoung Sang Nam Do. The subjects were divided into 3 groups according to different environments and styles of life, namely married life, widowhood and religious life and according to ages ranging between 45 and 55. Each of these 3 groups of women of .menopausal age consisted of 50 persons and totalling a group of 150. The subjects were chosen according to random sampling and the Cornell Medical Index was applied to discover physical and mental health status with the following results : 1. The total mean scores for complaints in the group of widows was 46.00, in the group of Married women was 37.10 and in the Sisters was 34.30 showing highest scores for the widows and lowest for the Sisters. 2. The mean score percentages for physical and mental complaints 28.80 and 16.50 respectively for the Widows:27.00 and 10.80 for the Married and 24.30 and 10.20 for the Sisters. 3. The highest number of mean scores for physical items was for digestive system complaints which showed a score of 5.04, 4.78 and 4.90 respectively for Widows, Married women and Sisters among the psychic status items all 3 groups showed highest scores for complaints of inadequacy: 5.52, 3.40 and 3.64 respectively. 4. In comparing the 2 groups of Married women and Widows, the highest significant differences appeared in the items of depression and sensitivity but there was also some significant difference in the items of inadequacy, anger, miscellaneous diseases and genito-urinary system complaints. 5. In comparing the Married women and Religious groups the highest significant differences according from the highest were as follows : cardiovascular system, sensitivity, tension, nervous system, frequent illnesses and anxiety.

  • PDF

Plastic기 복합재료의 파손강도 및 파괴인성에 미치는 원공크기의 영향 (The Effect of Hole Size on the Failure Strength and Fracture Toughness in Polymer Matrix Composite Plates)

  • 김정규;김도식
    • 한국재료학회지
    • /
    • 제3권2호
    • /
    • pp.197-204
    • /
    • 1993
  • Plastic기 복합재료의 파괴거동에 미치는 원공크기오 판폭의 영향을 검토하기 위하여 단축인장시험을 행하였다. 점응력파손조건에서의 특성길이 $d_o$는 원공크기 및 판폭에 의존하며, 이를 기초로 파손강도를 예측하기 위한 수정 점응력 파손조건식을 제안하였다. 이 파손조건의 예측값은 실험값과 잘 일치하였다. 파손 강도는 원공선단의 손상비의 증가에 따라 증가하며, 이는 손상영역의 형성으로 인한 응력완화현상으로 설명되어 진다. 또한 불안정 파괴시의 최대균열길이 $a_c$는 특성길이 $d_o$의 약 2배의 값을 나타낸다. 파괴인성에 대응하는 한계에너지해방율 $G_c$의 변화는 원공선단의 손상영역의 증가에 의한 응력완화가 주요한 원인이라고 할 수 있다.

  • PDF

뒤통수밑근 이완기법과 병행된 고주파 심부투열이 만성 긴장성 두통 환자들의 압통과 목 가동성 및 기능장애에 미치는 영향 (Effects of High-frequency Diathermy Integrated into Suboccipital Release on Tenderness and Neck Mobility and Disability in People with Chronic Tension-type Headache)

  • 이형렬;심재훈;오덕원
    • 한국전문물리치료학회지
    • /
    • 제24권2호
    • /
    • pp.37-47
    • /
    • 2017
  • Background: Active trigger points (TrPs) of the suboccipital muscles greatly contribute to the occurrence of chronic tension-type headache, with increased sensitivity of TrPs and facilitated referred pain. Objects: This study aimed to investigate whether the integration of high-frequency diathermy into suboccipital release is more beneficial than the use of suboccipital release alone. Methods: Thirty subjects were assigned to either experimental group-1 (EG-1) to undergo suboccipital release combined with high-frequency diathermy (frequency: 0.3 MHz, and electrode type: resistive electronic transfer), or EG-2 to undergo suboccipital release alone, or the control group (CG) with no intervention, with 10 subjects in each group. The assessment tools included the headache impact test 6 (HIT-6), perceived level of tenderness, neck disability index, and neck mobility. Intervention was performed for 10 minutes, twice per week, for 4 weeks, and measurements were performed before and after the interventions. Results: The between-group comparison of the post-test values and changes between pretest and post-test showed significant differences for all parameters at p<.05, except for the left-to-right lateral bending range. In the post hoc test, EG-1 showed significant differences for the parameters in comparison with the CG, while no significant differences in the perceived tenderness level, on both temporal regions, were found between EG-2 and CG. Furthermore, the HIT-6 score and perceived tenderness level, in the right temporal region, showed significant differences between EG-1 and EG-2. In the within-group comparison, EG-1 and EG-2 appeared to be significantly different between pretest and post-test (p<.05), except for the perceived tenderness level in the right temporal region, with significance for the EG-1 group only (p<.05). Conclusion: These findings suggest that the suboccipital release technique may be advantageous to improve headache, tenderness, and neck function and mobility, with more favorable effects with the incorporation of high-frequency diathermy.

광섬유 센서에 의한 말뚝 하중전이 측정 (Measurement of Pile Load Transfer using Optical Fiber Sensors)

  • 오정호;이원제;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.397-404
    • /
    • 1999
  • It is essential to measure load transfer mechanism of pile to check the appropriateness of assumptions made for design purpose and to continuously monitor the behavior of pile foundation. Through many attempts to monitor the behavior of super-structure in civil engineering area using several optical fiber sensors have been made, application of optical fiber sensor technology on pile foundation has not been tried up to now. Load transfer of model piles during compression loading was measured by optical fiber sensors and compared with the measurement by strain gauges. Fiber Bragg Grating(FBG) sensor system was used since it has many advantages, such as easy multiplexing, high sensitivity, and simple fabrication. Besides the model pile tests, uniaxial tension test of steel bar and compression tests of mortar specimen were carried out to evaluate the performance of FBG sensors in embedded environments. The shift of refilming wavelength due to the strain in FBG sensor is converted to the strain at sensor location and the dependence between them is 1.28 pm/${\mu}$ strain. FBG sensors embedded in model pile showed a better survivability than strain gauges. Measured results of load transfer by both FBG sensors and strain gauges were similar, but FBG sensors showed a smoother trend than those by strain gauge. Based on the results of model pile test, it was concluded that the use of FBG sensor for strain measurement in pile has a great potential for the analysis of pile load transfer.

  • PDF

방적기계용 스핀들 인서트의 최적설계 관한 연구 (The Study for Optimal Design of Spindle Insert used in Cotton Spinning Machine)

  • 이동우;허선철;이상석;심재준
    • 한국정밀공학회지
    • /
    • 제27권4호
    • /
    • pp.72-78
    • /
    • 2010
  • Textile machinery affects various industry, such as sport leisure industry, metal and chemistry material, electric electron, mechanical energy, packing and printing industry. In case of design of textile machine, the very important fact is absorbing the minute vibration induced by spinning thread and insert which is the part of spindle plays a role of reduction of impact caused by oscillation of thread bobbin. Therefore, Optimal design was executed by design of experiments and kriging optimal design methods to prevent fracture of spindle insert under the fatigue condition and deduced the best value of design parameter to improve the stability of the products. The highest sensitivity is showed at the design parameter A and D. As the spiral number of insert is increase, tension force applied its edge is distributed at whole model and the stress concentration is reduced.