• Title/Summary/Keyword: tension measurement

Search Result 361, Processing Time 0.031 seconds

A Study on a micro dynamic tester development for a micro property measurement of a micro metal specimen (마이크로 금속 박판의 동적 물성치 측정을 위한 마이크로 동적 시험 장치 개발에 관한 연구)

  • Lee, Jin-Pyo;Lee, Hye-Jin;Hwang, Jai-Hyuk;Lee, Nak-Kyu;Bae, Jae-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.163-168
    • /
    • 2006
  • In a micro-unit of electronic-machine, vibration can be excited by a small impact, and this vibration acts as a fatigue load. To measure the vibration effect on the micro unit, a micro dynamic tester is needed to test a micro specimen. In this paper, it has confirmed a movement of the PZT(piezo actuator) to use a sine signal. And, it has confirmed a fracture of specimens by using a tension-tension input signal in PZT. A metal-material property in the micro scale has been tested to compare with the macro scale. A fatigue test has been conducted by using PZT actuator to give a bending-tension effect.

  • PDF

The Effects of Sc on the Microstructure of Hypoeutectic Al-Si Alloys (아공정 Al-Si합금 조직에 미치는 Sc의 효과)

  • Kim, Myung-Han;Lee, Jong-Tae
    • Journal of Korea Foundry Society
    • /
    • v.24 no.3
    • /
    • pp.145-152
    • /
    • 2004
  • The eutectic Si in Al-8.5wt.%Si alloy was changed from large flake to fine lemellar(or fibrous) shape when the Sc amount in the Al-Si alloy reaches 0.2wt.%. The optimum amount of Sc for the best modification effect was 0.8wt.% and slight decrease of modification effect occurred over this value. The study on the distribution of the modifiers(Sr, Na, and Sc) and the measurement of the surface tension of the Al-8.5wt.%Si alloy melt added with Sr, Na, and Sc modifier, respectively, reveals that Sc modifies the eutectic Si by the decrease of surface tension, while Sr and Na modify the eutectic Si mainly by impurity induced twinning mechanism.

A Study on the Efficient Tension Estimation of Cables under Ambient Vibration using Minimized Measurement and Signal Processing System (최소화된 계측 및 신호 처리 시스템을 이용한 상시진동 케이블의 효율적인 장력 추정에 관한 연구)

  • Lee, Hyeong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.594-603
    • /
    • 2018
  • Recently, according to the development of measurement techniques, it has become possible to take complicated and time-consuming field measurements in a simple and convenient manner. In this background, this study estimated the tension of cables under ambient vibration using minimized measurement and signal processing. The VBDM using video-only by low-cost equipment was used as a minimized measurement. An estimation of the natural frequency using the mirror frequency concept was also proposed to solve the shortage of frequency band in this case. Furthermore, the FDD method was adopted for a natural frequency estimation in the ambient vibration related to field application. Experimental studies using a cable-stayed bridge model were carried out to examine the properties of the mirror frequency and the applicability of FDD with the proposed minimized system. The results showed that FDD for ambient vibration also works properly in an estimation of the natural frequency using the minimized system. In addition, the mirror frequency concept can allow a high natural frequency estimation even in a distorted signal by low-speed recording, which can overcome the limit of the minimized system. Overall, the proposed minimized system can be effective for the tension estimations of a cable under ambient vibration.

Surface Activities of Carboxybetaine Derivatives (카르복시베타인 유도체(誘導體)의 계면활성(界面活性))

  • Shon, Joo-Hwan;Kim, Yu-Ok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.43-48
    • /
    • 1987
  • Isoelectric point and surface tension of twelve of the alkylcarboxy betaines such as 2-(trimethylammonio) dodecanoate, 2-(trimethyammonio) tetradecanoate, 2-(trimethylammonio) hexadecanoate, (dimethyldodecylammonio)ethanoate, (dimethyltetradecylammonio)ethanoate, (dimethylhexadecylammonio) ehtanoate, 2-(dimethylododecylammonio) propanoate, 2-(dimethyltetradecylammonio)proopanoate, 2-(dimethylhexadecylammonio)propanoate, 2-(dimethyltetradecylammonio)-3-phenyl propanoate, 2-(dimethyltetradecylammonio)-3-phenyl propanoate are tested. From the measurement of the isoelectric point, it was found that the isoelectric point were leaned toward the alkaline zone for c-alkylarbrxybetaines, and toward the acidic zone for N-alkylcarboxybetaines. At the range of the carboxybetaine concentration $2\;{\times}\;10^{-2}{\sim}2\;{\times}\;10^{-5}$mole/l, the surface tension of the aqueous solution were decreased to 30-38 dyne/cm, showing the tendency that the ability of lowering the surafce tension was depending on the increase of carbon atom number in the lipophilic alkyl chain. The critical micelle concetration measured by the surface tension and concentration curves have been found at the range of $10^{-2}{\sim}10^{-5}$mole/l.

An Experimental Study on the Motion of the Floater Moored near Port in Waves Generated by a Ship

  • Nguyen, Thi Thanh Diep;Nguyen, Van Minh;Yoon, Hyeon Kyu;Kim, Young Hun
    • Journal of Navigation and Port Research
    • /
    • v.44 no.5
    • /
    • pp.363-374
    • /
    • 2020
  • In the past, various research on the effects of waves generated by ships has been investigated. The most noticeable effect of the waves generated by a passing ship is the increase of the hydrodynamic forces and the unwanted large motion of the moored ship and high mooring forces that occur. Thus, it is crucial to investigate the effect of the waves generated by the passing ship near port on the motion of the moored ship and the tension of the mooring lines. A model test was performed with virtual ship-generated waves in a square tank at CWNU (Changwon National University). The IMU (Inertial Measurement Unit) and Optical-based system were used to measure the 6DOF (Six Degrees of Freedom) motion of the moored floater. Additionally the tension of mooring lines were measured by the tension gauges. The effects of the wave direction and wave height generated by the virtual ship-generated waves on the motion of the moored floater were analyzed.

An Experimental Study on Biaxial Tensile Characteristics of ETFE Film and Stress Relaxation of Tension Typed Membrane Structures (ETFE 필름의 2축 인장특성 및 텐션방식 막구조물의 응력완화 거동에 관한 실험적 연구)

  • Kim, Seung-Deog;Jeong, Eul-Seok;Kawabata, Masaya
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Until recently, almost all ETFE film structures that have been erected is the cushion type because there are problems at lower allowable strength under elastic range and viscosity behaviour such as creep and relaxation of ETFE films under long-term stresses. But the number of tension type structures is currently increasing. This paper proposes the stretch fabrication of ETFE film to verify the applicability of ETFE films to tensile membrane structures. First of all, to investigate the possibility of application on tensile membrane structures, the stretch fabrication test is carried out, and it is verified that it is possible to increase the yield strength of the film membrane structures. After simulating the experiment also carries out an analytical investigation, and the effectiveness of the elasto-plastic analysis considering the viscous behavior of the film is investigated. Finally, post-aging tension measurement is conducted at the experimental facilities, and the viscosity behavior resulting from relaxation is investigated with respect to tensile membrane structures.

Application of Vibration Method for Estimation of Tension Force of Stay Cables in World-Cup Stadiums (월드컵경기장 지지케이블의 장력추정을 위한 진동법의 적용성 평가)

  • Chang, Kug-Kwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.156-165
    • /
    • 2009
  • This study is to consider the character of cables in six World-Cup stadiums constructed in 2002 and to inspect problems on measurement natural frequencies interpretation and application of existing theory. The results of the experiment were shown that it was possible to determine the tension force of the real cables with an accuracy of 8% by taking the cable bending stiffness. But for the range of cable affected greatly by bending stiffness(${\xi}{\leq}7$), it was appeared the tendency to increase estimated error and was considered to need additional study of this range. Estimated tension error could not be improved so much in comparison to the case using single mode of vibration even through multiple modes of vibration were used.

Comparison of the effects of temporomandibular joint and cervical vertebra treatment on pain and functional improvement in persons with tension-type headaches

  • Kwon, Junghyun;Yu, Wonjong
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.202-209
    • /
    • 2019
  • Objective: The purpose of this study was to evaluate the effects of temporomandibular joint and cervical vertebra treatment in persons with tension-type headaches on pain, tenderness, and functional improvement. Design: Three-group pretest-posttest design. Methods: Subjects with tension-type headaches were divided into the temporomandibular joint and cervical vertebra treatment group (n=11), temporomandibular joint treatment group (n=11), and cervical vertebra treatment group (n=11), and pre- and post-evaluation was performed. The temporomandibular joint treatment group underwent compression massage and joint ply of the muscles around the temporomandibular joint. The cervical vertebra group received deep tendon massage and Myofascial Release of the cervical muscles. The temporomandibular joint and cervical vertebra treatment group performed both types of treatment. Treatment was performed for 50 minutes, three times a week for 4 weeks. Measurement tools included the Korean version of the short form-McGill Pain Questionnaire (SF-MPQ, K), Headache Impact test-6 (HIT-6), Neck Disability Index (NDI), and the Digital Algometer FPX25. Results: The groups showed significant differences in SF-MPQ, HIT-6 test, NDI, and Alogometer FPX25 test scores before and after intervention (p<0.05). The differences between the groups were most significant in the group that received treatment of the temporomandibular joint and cervical vertebra (p<0.05). Conclusions: In this study, the treatment of the temporomandibular joint and cervical vertebra was shown to be effective for improving pain, quality of life, and cervical vertebra in persons with tension-type headaches. This data may be helpful in identifying treatment techniques for tension-type headaches in the future.

Measuring machine parameters of inverter-fed induction motors for an accurate torque control (고정밀 토크제어를 위한 인버터 구동 유도전동기의 상수 측정)

  • Lee Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.12-16
    • /
    • 2002
  • This paper deals with the measurement of machine parameters of inverter-fed induction motors for an accurate torque control applications such as machine tools and tension control machines. After discussing nonlinearities of both inverter and motor, this paper suggests appropriate compensation and measurement methods. The experimental results show the validity of the proposed method in the operating conditions.

  • PDF

Verification for Reduction of Membrane Stress Measurement Equipment Size Using White Noise Sound Wave (화이트노이즈를 이용한 막장력 측정장치의 소형·경량화 검증)

  • Jin, Sang-Wook
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.3
    • /
    • pp.67-74
    • /
    • 2014
  • The author has proposed and verified the accuracy through experiments on a method of measurement through the use of sound waves that not only can quantitatively measure each of the dual directions of the fiber axis with high accuracy of membrane tension created on the surface of the membrane structure, but also can be easily operated in the field of construction. This paper reports the solution for problems of variables caused in the process of downsizing of the measurement equipment in order for practical use, and verifies the correspondence possibility of various stress ratios.