• Title/Summary/Keyword: tension measurement

Search Result 361, Processing Time 0.029 seconds

Field Application Analysis of Cable Tension Measuring Device on Cable-Stayed Bridges (사장교 케이블장력 계측장치의 현장적용성 분석)

  • Lee, Hyun-Chol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.295-311
    • /
    • 2021
  • In this study, an experiment was carried out on the field applicability of tension measuring devices of the cables in cable-stayed bridges. The vibration method was used to estimate the tension of cables of cable-stayed bridge, and the mode characteristics of the cable were analyzed using a cable tension measuring device. GTDL360, NI Module, and 9 Axes Motion Sensorwere applied to estimate the cable tension of five target bridges. Numerical analysis of the five target bridges was conducted to analyze the natural frequency of the cable and cable tension. The estimated tension of the cable based on field measurements and estimated tension of cable by numerical analysis were compared with the estimated tension of the cable based on field measurements. The analysis showed that the measured tension of the cable based on field measurements was within the margin of error. Therefore, it is safe to apply these measuring devices to the site. As a result of comparing and analyzing the values of the acceleration-based cable estimation tension and numerical analysis of the field demonstration bridge, the acceleration-based cable estimation of tension is deemed appropriate within the allowable range. On-site applicability analysis revealed limitations of the measuring devices, such as the installation location of sensors and weather conditions, so continuous follow-up research on smart cable tension measuring systems is expected.

Post-yielding tension stiffening of reinforced concrete members using an image analysis method with a consideration of steel ratios

  • Lee, Jong-Han;Jung, Chi-Young;Woo, Tae-Ryeon;Cheung, Jin-Hwan
    • Advances in concrete construction
    • /
    • v.7 no.2
    • /
    • pp.117-126
    • /
    • 2019
  • When designing reinforced concrete (RC) members, the rebar is assumed to resist all tensile forces, but the resistance of the concrete in the tension area is neglected. However, concrete can also resist tensile forces and increase the tensile stiffness of RC members, which is called the tension stiffening effect (TSE). Therefore, this study assessed the TSE, particularly after yielding of the steel bars and the effects of the steel ratio on the TSE. For this purpose, RC member specimens with steel ratios of 2.87%, 0.99%, and 0.59% were fabricated for uniaxial tensile tests. A vision-based non-contact measurement system was used to measure the behavior of the specimens. The cracks on the specimen at the stabilized cracking stage and the fracture stage were measured with the image analysis method. The results show that the number of cracks increases as the steel ratio increases. The reductions of the limit state and fracture strains were dependent on the ratio of the rebar. As the steel ratio decreased, the strain after yielding of the RC members significantly decreased. Therefore, the overall ductility of the RC member is reduced with decreasing steel ratio. The yielding plateau and ultimate load of the RC members obtained from the proposed equations showed very good agreement with those of the experiments. Finally, the image analysis method was possible to allow flexibility in expand the measurement points and targets to determine the strains and crack widths of the specimens.

Development of the Strain Measurement-based Impact Force Sensor and Its Application to the Dynamic Brazilian Tension Test of the Rock (변형률 게이지 측정원리를 이용한 충격 하중 센서의 개발 및 암석의 동적 압열 인장 실험에 적용)

  • Min, Gyeong-jo;Oh, Se-wook;Wicaksana, Yudhidya;Jeon, Seok-won;Cho, Sang-ho
    • Explosives and Blasting
    • /
    • v.35 no.3
    • /
    • pp.15-20
    • /
    • 2017
  • In order to obtain the dynamic response behavior of the rock subjected to blasting loading, a shock-proof high sensitivity impact sensor which can measure high frequency dynamic force and strain events should be adopted. Because the impact sensors which uses quartz and piezoelectric element are costly, generally the strain measurement-based impact (SMI) sensors are applied to high speed loading devices. In this study, dynamic Brazilian tension tests of granitic rocks was conducted using the Nonex Rock Cracker (NRC) reaction driven-high speed loading device which adopts SMI sensors. The dynamic response of the granite specimens were monitored and the intermediate strain rate dependency of Brazilian tensile strengths was discussed.

Development of Measuring System of Membrane Stress for Membrane Structure (막구조물의 막장력 측정장치 개발에 관한 연구)

  • Jung, Hwan-Mok;Woo, Jae-Won;Cho, Byung-Wook;Lee, Seong-Yeun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.6
    • /
    • pp.67-74
    • /
    • 2008
  • This paper is concerned with the development of a measurement system using field measuring device which will give the membrane stress of the membrane structures. Up to this point, several techniques on measurement of membrane stresses has been proposed and some have been used in the fields, but accuracy of the measured stresses to be far from reliable one. Such situation has not been changed until recent days, we do not have the measurement device on which we can depend. On top of that, due to the different properties in cross directions for material of the membrane, the stress in the warp direction is different from that in the fill one.

  • PDF

Nondestructive Damage Sensitivity for Functionalized Carbon Nanotube and Nanofiber/Epoxy Composites Using Electrical Resistance Measurement and Acoustic Emission (전기저항 측정과 음향방출을 이용한 표면 처리된 탄소 나노튜브와 나노 섬유 강화 에폭시 복합재료의 비파괴적 손상 감지능)

  • Kim, Dae-Sik;Park, Joung-Man;Kim, Tae-Wook
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.42-45
    • /
    • 2003
  • Nondestructive damage sensing and mechanical properties for acid-treated carbon nanotube (CNT) and nanofiber (CNF)/epoxy composites were investigated using electro-micromechanical technique and acoustic emission (AE). Carbon black (CB) was used to compare to CNT and CNF. The results were compared to the untreated case. The fracture of carbon fiber was detected by nondestructive acoustic emission (AE) relating to electrical resistivity under double-matrix composites test. Sensing for fiber tension was performed by electro-pullout test under uniform cyclic strain. The sensitivity for fiber damage such as fiber fracture and fiber tension was the highest for CNT/epoxy composites. Reinforcing effect of CNT obtained from apparent modulus measurement was the highest in the same content. For surface treatment case, the damage sensitivity and reinforcing effect were higher than those of the untreated case. The results obtained from sensing fiber damage were correlated with the morphological observation of nano-scale structure using FE-SEM. The information on fiber damage and matrix deformation and reinforcing effect of carbon nanocomposites could be obtained from electrical resistivity measurement as a new concept of nondestructive evaluation.

  • PDF

Development of a Wireless Telemetry Measurement Algorithm Using Smart Phones and Digital Image Correlation (스마트 폰과 이미지 상관법을 이용한 무선 원격 계측 알고리즘 개발)

  • Choi, In Young;Kang, Young June;Hong, Kyung Min;Kim, Seong Jong;Lee, Hae Gyu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.4
    • /
    • pp.434-440
    • /
    • 2015
  • A smart phone is a multimedia device that is a necessity for modern people. It includes a wireless networking system to share information and pictures. However, numerous smart phones are discarded every year, since they have a very fast technology development cycle. This paper presents the development of a telemetry algorithm to measure displacement and strain with a discarded smart phone and digital image correlation methods. To implement the measurement algorithm, the LabVIEW 2010 program development platform was used. In order to verify reliability, an open hole tension test was conducted using a smart phone and a universal test machine. In addition, the measurement results from the smart phone were compared with FEM analysis results.

Measurement of Isoelectric Point of Betaine Zwitterionic Surfactant by QCM(Quartz Crystal Microbalance) (QCM(Quartz Crystal Microbalance)을 이용한 Betaine 양쪽성 계면활성제의 등전점 측정)

  • Kim, Ji Sung;Park, Jun Seok;Lim, Jong Choo
    • Korean Chemical Engineering Research
    • /
    • v.47 no.1
    • /
    • pp.31-37
    • /
    • 2009
  • A zwitterionic surfactant shows not only detergency but also mildness effect since it shows characteristics of a nonionic or an anionic surfactant above an isoelectric point, while showing characteristics of a cationic surfactant below an isoelectric point. Therefore, a zwitterionic surfactant can serve as a dual function surfactant by a single molecule through the interconversion of cleaning and softening effects depending on pH variations of the aqueous solution. In this study, physical properties of betaine surfactant such as CMC, surface tension, interfacial tension, contact angle and viscosity were measured and phase behavior study was performed. Also dual function characteristics of betaine zwitterionic surfactant were investigated by measuring an isoelectric point using QCM(quartz crystal microbalance) and zeta potential measurement. The CMC of betaine surfactant was near $10^{-4}mol/L$ and the surface tension at CMC was about 32 mN/m. The interfacial tension between 1 wt% aqueous solution and n-decane measured by spinning drop tensiometer at pH 2~10 resulted in an increase in interfacial tension until pH 5 and a decrease with pH after 5 and equilibration time showed the similar trend with an increase in pH. The isoelectric point of betaine surfactant measured by QCM experiment was found to exist between 3.0 and 3.3, which is the same as the result determined by zeta potential measurement.

Tension Estimation of External Tendons in PC Bridges Using Vibration Measurement Method (진동 측정법을 이용한 PC교량 외부텐던의 장력 추정)

  • Park, Sung Woo;Jung, Ha Tae;Jung, Soo Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.84-92
    • /
    • 2014
  • In this study, vibrational tendon tension measurement methods are applied to estimate tension of external tendons used in segmental post-tensioned bridges. The acceleration of various length type of tendons is measured and natural frequencies are obtained using FFT (Fast Fourier Transform). The obtained natural frequencies are within 1% error regardless of sensor direction and location. On the basis of natural frequency of tendon, estimation of the tendon tension is performed by using many types of solutions such as string theory equation, multi mode estimation, practical formula estimation and stiff string with clamped-clamped boundary conditions. The results are compared with each other and have shown that the flexural stiffness is not negligible in tendons of this type causing the vibration mode to be inharmonically related. The results have shown that the method using stiff string equation with clamped-clamped boundary conditions is more accurate than the other methods. Application example of in-service bridges has shown that force distribution effects from friction at deviation blocks can be effectively detected.

A Study on Synthesis of Glycidol Based Nonionic Surfactant (글리시돌을 원료로 한 비이온 계면활성제 합성에 관한 연구)

  • Lim, Jong Choo;Kim, Byeong Jo;Choi, Kyu Yong
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.282-291
    • /
    • 2012
  • The PGLE and PGLE3 nonionic surfactants were synthesized from the reaction between glycidol and lauryl acid and their structures were confirmed by $^1H$ and $^{13}C$ NMR analysis. The CMCs of PGLE and PGLE3 surfactants were found to be $3.59{\times}10^{-2}$ mol/L and $8.80{\times}10^{-2}$ mol/L respectively and the surface tensions at their CMC conditions were 26.09 mN/m and 28.68 mN/m respectively. Dynamic surface tension measurement has shown that the adsorption rate of surfactant molecules at the interface between air and surfactant solution was found to be relatively fast in both surfactant systems, presumably due to high mobility of surfactant molecules. The contact angles of PGLE and PGLE3 nonionic surfactants were $25.5^{\circ}$ and $9.5^{\circ}$ respectively. Dynamic interfacial tension measurement showed that both surfactant systems reached equilibrium in 20 minutes and the interfacial tensions at equilibrium condition in both systems were 0.42 mN/m and 0.53 mN/m respectively. The PGLE surfactant system has indicated higher foam stability than the PGLE3 surfactant system, which is consistent with surface tension measurement. The phase behavior experiments performed at $25{\sim}60^{\circ}C$ in systems containing nonionic surfactant, water, n-hydrocarbon oil and cosurfactant showed a lower phase or oil in water microemulsion in equilibrium with excess oil phase at all conditions investigated during this study.