• Title/Summary/Keyword: tension measurement

Search Result 360, Processing Time 0.033 seconds

The Establishment of Bonding Conditions of Cu Sheet using an Ultrasonic Metal Welder (초음파 금속 용착기를 이용한 Cu 박판의 접합성 평가)

  • Park, Woo-Yeol;Jang, Ho-Su;Park, Dong-Sam
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.2
    • /
    • pp.66-72
    • /
    • 2012
  • Ultrasonic metal welder is consisted of power supply, transducer, booster, and horn. Precise designing is required since each part's shape, length and mass can affect driving frequency and vibration mode. This paper gives a description of an experimental study of the ultrasonic welding of metals. A horn suitable for 40,000Hz was attached to the ultrasonic metal welder in order to weld Cu sheet. The Cu sheet welding was done with different amplitude, pressure and welding time, and its maximum tension was measured. Maximum tension of 177.99N was obtained when the pressure was 2.5bar, amplitude was 80%, and welding time was 0.34sec. Therefore, excessive welding condition negatively influences maximum tension measurement result.

A Study on the High-Temperature Strain Measurement of Perfectly Flat CRT (완전평면 브라운관의 고온 변형률 측정에 관한 연구)

  • Kang, Dae-Jin;Kim, Kug-Weon;Han, Eung-Kyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.8
    • /
    • pp.23-27
    • /
    • 1999
  • The measurement of thr high-temperature strains is one of the challenging subjects in mechanical engineering. For the precise measurement, proper high-temperature strain gauge, cement and skilled technique are needed. In this paper, a high-temperature strain measurement is performed for the perfectly flat CRT. As this CRT is structurally very weak, cracking of the panel frequently occurs during the heat cycle in the furnace. From the measured strain variations of the panel with tension shadow mask, the crack behavior can be explained.

  • PDF

Relationship between Interfacial Tension and Solubility of Diesel Fuel in Surfactant Solutions (계면활성제용액-경유 간 계면장력과 용해도 상관관계 연구)

  • Jeong, Seung-Woo;Hur, Jeong-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.70-73
    • /
    • 2013
  • Solubility of oil contaminants in surfactant solutions plays an important role in selecting a suitable surfactant type for soil remediation. Solubility measurement procedures consist of making an equilibrium between surfactant solution and oil, solvent extraction using dichloromethane, and condensation for gas chromatography analysis. Solubility measurement requires time consumption and lots of materials. Interfacial tension is the contracting force between two immiscible liquids, surfactant solution and oil, and also closely related to solubility of oil. This study established a relationship between the interfacial tension and solubility of diesel fuel in surfactant solution and suggested a quick method to estimate solubility of oil in a surfactant solution by measuring its interfacial tension. The results of this study showed that the solubility of diesel fuel in surfactant solution was exponentially increased by decreasing the interfacial tension between two immiscible liquids. The solubility of diesel fuel was significantly increased under the interfacial tension conditions below 1 dyne/cm, while the solubility change was not apparent under the interfacial tension conditions beyond 5 dyne/cm. Interfacial tension measurements may allow us to quickly select an efficient surfactant and its concentration for soil remediation.

A Study on Evaluation Method of Cable Tension for Railway Steel Composite Bridge (강철도 복합교량 케이블의 장력 평가기법에 관한 연구)

  • Choi, Jung-Youl;Lee, Soo-Jae;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.4
    • /
    • pp.407-413
    • /
    • 2022
  • In this study, the empirical formula for evaluating cable tension based on long-term measurement for about 3 years according to temperature change was proposed by proving the correlation between the expansion joint displacement of the upper road bridge and the cable tension of the lower railway bridge. The tension prediction results using the empirical formula for tension evaluation each cables proposed in this study were found to be in good agreement with the cable tension using the vibration method within 3%. Therefore, it was analyzed that it could be applied together with the vibration method that was an experimental technique, to predict and evaluate the cable tension in serviced railway steel composite bridge. As a result of applying the estimated temperature calculated by the empirical formula for expansion proposed in this study to the empirical formula, it was analyzed that a high level of reliability could be secured when compared with the vibration method. Therefore, it is judged that the empirical formula for cable tension evaluation reflecting the estimated temperature proposed in this study can be used to predict the tension of cables according to climate change in the future and establish a maintenance plan.

Test and Analysis of a Turn-buckle for Tensile Force Measurement (인장력 측정용 턴버클의 실험 및 해석)

  • Lee, Swoo Heon;Shin, Kyung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.2
    • /
    • pp.183-192
    • /
    • 2009
  • A turn-buckle inserted between tension members sustaining structural loads in the suspension structure system is a device capable of adjusting the tensile force. However, it is difficult to measure the tensile force that is applied to the tension member with the use of a conventional turn-buckle. So a measurable turn-buckle for tensile force measurement has been developed to improve on such a problem. This study focuses on the prevention of a local yielding as well as the maximization of yielding load mentioned in previous studies. A new type of turn-buckle for the measurement to practical use is suggested over the tentative purpose. For this purpose, the ABAQUS analysis of specimens based on theoretical analysis and tests are carried out. The differences among the results of the theoretical analysis, ABAQUS analysis, and the test were insignificant.

Manufacturing Process of Translucent Microemulsion and Its Stability (Translucent Microemulsion의 제조 공정과 안정성)

  • Bae, Duck-Hwan;Shin, Jae-Sup
    • Journal of the Korean Applied Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.167-173
    • /
    • 2000
  • The process variables for the manufacture of translucent microemulsion prepared with 2-octyl dodecanol, 12-hydroxy stearic acid cholesteryl , POE(40)HCO and 1,3-butandiol were examined initially (primary emulsion) and following aging for three months. The techniques empolyed in this study were particle size, turbidity, interfacial tension and microfluidizer. Particle size analysis and turbidity measurement to evaluate the emulsion stability were used. It was concluded that the process of the emulsification was an important indicator of the stability of the translucent microemulsion. From the particle size and and turbidity measurement of translucent microemulsion, adding the surfactant to the oil phase before the emulsification was found to be the most important factor for the stability of emulsions. We found that interfacial tension of the adding the surfactant to the oil phase is lower than that of the adding the surfactant to aqueous phase. In spite of hydrophilic surfactant, adding the surfactant to aqueous phase produced inferior emulsion to that to oil phase.

Measurement of Wire Displacement of WEDM using He-Ne laser (He-Ne 레이저를 이용한 와이어 방전가공기의 와이어 변위 측정)

  • 홍준모;전병철;조용무;유웅재;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.414-419
    • /
    • 1995
  • The wire displacement of wire electric discharge machine has been measured using He-Ne laser. A measurement system consisted of He-Ne laser, A/D converter, 4 divided photodiode, amplifier, sensor process instrument, and personal computer. The processing parameters were varid with feed rate, wire tension, wire speed and voltage. The laser beam intensity transmitted on a 4 divided photodiode was varied by processing wire electric descharge machine with various process parameters. The 4 divided photodiode and amplifier were used to change the detected beam intensity into voltage. Variation of wire displacement was between 11 and 125 .mu. m. The wire tension was dominant on the variation of wire displacement among many parameters.

  • PDF

Evaluation of Fracture Toughness of Al alloys for Propulsive Engine using Strain Measurement (변형률 측정을 이용한 추진기관용 Al 합금의 파괴인성 평가)

  • 김재훈;김덕회;임동규;박성욱;문순일
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.3
    • /
    • pp.13-21
    • /
    • 2002
  • The tincture toughness is evaluated by using U(compact tension) and 3PB(three point bending) specimens of AI alloys far propulsive engine. To evaluate the static fracture toughness, strain gage method is used. The static fracture toughness obtained from the strain measurement is compared with the results by ASTM standard and FEM analysis. For the reliable evaluation of fracture toughness, strain gages are attached at various positions.

Effect of Cable Tension Changes on Track Irregularity of Railway Ballasted Track on Railway Steel Composite Bridge (케이블 장력변화가 강철도 복합교량 상 자갈궤도의 궤도틀림에 미치는 영향)

  • Jung-Youl Choi;Soo-Jae Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.633-638
    • /
    • 2023
  • In this study, the effect of the change in cable tension on the track irregularity of railway ballasted track on a railway steel composite bridge was analyzed. As a result of comparing design and analysis results for cable tension, a difference of less than 3% was found, and analysis modeling was analyzed to reflect the design conditions well. In addition, the adequacy of the analysis modeling was demonstrated by comparing the field measurement results with the analysed cable tension. By considering the change in cable tension as a variable, the track irregularity of the railway steel composite bridge was analyzed. As a result of the analysis, it was analyzed that the total and one-sided cable tension change had a direct effect on the vertical irregularity among the track irregularity items. In addition, it was found that the change in track irregularity occurred in the section close to the cable position. It was analyzed that the change in cable tension had a more direct effect on track irregularity that had a direct correlation with the vertical direction rather than the lateral direction.

Study on the Development of the Displacement and Strain Distribution Measurement Algorithm to the Open Hole Tension Test by Using the Digital Image Correlation (이미지 상관법을 이용한 원공 인장 시편 변위 및 변형율 측정을 위한 알고리즘 개발에 관한 연구)

  • Choi, In Young;Kang, Young June;Hong, Kyung Min;Lee, Hak Seong;Kim, Seong Jong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.2
    • /
    • pp.121-128
    • /
    • 2016
  • The mechanical jointing method is very important in the machine parts and structure. They are used by the bolts and rivet because it is very convenient to replace the parts and the structure. However, the mechanical jointing methods using the bolt and rivet needed the open hole. The machine parts life cycle is reduced because this open hole created the stress concentration. Therefore, the measurement methods are needed to evaluate phenomenon of the stress concentration. This paper discusses the development of the measurement algorithm using the digital image correlation methods to measure the strain distribution of the open hole. To implement the measurement algorithm using the DIC, the LabVIEW 2010 programming tool was used. To measure the strain distribution of the open hole, the tensile specimens having an open hole are made by using the aluminum 6061-T6. To secure the reliability of measurement result using the DIC, the DIC measurement results and FEM analysis results were compared.