• Title/Summary/Keyword: tensile strength measurement

Search Result 297, Processing Time 0.024 seconds

Comparison of measurement uncertainty calculation methods on example of indirect tensile strength measurement

  • Tutmez, Bulent
    • Geomechanics and Engineering
    • /
    • v.12 no.6
    • /
    • pp.871-882
    • /
    • 2017
  • Indirect measure of the tensile strength of laboratory samples is an important topic in rock engineering. One of the most important tests, the Brazilian strength test is performed to obtain the tensile strength of rock, concrete and other quasi brittle materials. Because the measurements are provided indirectly and the inspected rock materials may have heterogeneous properties, uncertainty quantification is required for a reliable test evaluation. In addition to the conventional measurement evaluation uncertainty methods recommended by the Guide to the Expression of Uncertainty in Measurement (GUM), such as Taylor's and Monte Carlo Methods, a fuzzy set-based approach is also proposed and resulting uncertainties are discussed. The results showed that when a tensile strength measurement is measured by a laboratory test, its uncertainty can also be expressed by one of the methods presented.

Numerical simulation of compressive to tensile load conversion for determining the tensile strength of ultra-high performance concrete

  • Haeri, Hadi;Mirshekari, Nader;Sarfarazi, Vahab;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.605-617
    • /
    • 2020
  • In this study, the experimental tests for the direct tensile strength measurement of Ultra-High Performance Concrete (UHPC) were numerically modeled by using the discrete element method (circle type element) and Finite Element Method (FEM). The experimental tests used for the laboratory tensile strength measurement is the Compressive-to-Tensile Load Conversion (CTLC) device. In this paper, the failure process including the cracks initiation, propagation and coalescence studied and then the direct tensile strength of the UHPC specimens measured by the novel apparatus i.e., CTLC device. For this purpose, the UHPC member (each containing a central hole) prepared, and situated in the CTLC device which in turn placed in the universal testing machine. The direct tensile strength of the member is measured due to the direct tensile stress which is applied to this specimen by the CTLC device. This novel device transferring the applied compressive load to that of the tensile during the testing process. The UHPC beam specimen of size 150 × 60 × 190 mm and internal hole of 75 × 60 mm was used in this study. The rate of the applied compressive load to CTLC device through the universal testing machine was 0.02 MPa/s. The direct tensile strength of UHPC was found using a new formula based on the present analyses. The numerical simulation given in this study gives the tensile strength and failure behavior of the UHPC very close to those obtained experimentally by the CTLC device implemented in the universal testing machine. The percent variation between experimental results and numerical results was found as nearly 2%. PFC2D simulations of the direct tensile strength measuring specimen and ABAQUS simulation of the tested CTLC specimens both demonstrate the validity and capability of the proposed testing procedure for the direct tensile strength measurement of UHPC specimens.

Measurement of Tensile Properties of Copper Foil using Micro-ESPI Technique (마이크로 ESPI기법을 이용한 동 박막의 인장 특성 측정)

  • 김동일;허용학;기창두
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.8
    • /
    • pp.89-96
    • /
    • 2004
  • Micro-tensile testing system, consisting of a micro tensile loading system and micro-ESPI(Electronic Speckle Pattern Interferometry) system, has been developed for measurement of micro-tensile properties of thin micro-materials. Micro-tensile loading system had a load cell with the maximum capacity of 50N and micro actuator with resolution of 4.5nm in stroke. The system was used to apply a tensile load to the micro-sized specimen. During tensile loading, the micro-ESPI system acquired interferornetric speckle patterns in the deformed specimen and measured the in-plane tensile strain. The ESPI system consisted of a CCD-camera with a lens and the window-based program developed for this experiment. Using this system, stress-strain curves for 4 kinds of electrolytic copper foil 18$\square$m thick were obtained. From these curves, tensile properties, including the elastic modulus. yielding strength and tensile strength, were determined and also values of the plastic exponent and coefficient based on Ramberg-Osgood relationship were evaluated.

Estimation of Measurement Uncertainty in Evaluation of Tensile Properties (인장 물성 측정 불확도 평가)

  • Huh, Y.H.;Lee, H.M.;Kim, D.J.;Park, J.S.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.73-78
    • /
    • 2010
  • Estimation of tensile properties measurement uncertainty of material was carried out. Sources of uncertainty affecting the measurement of tensile properties were classified and analyzed. The models for uncertainty evaluation of measurands to be determined from tensile test, such as elastic modulus, yield strength and tensile strength, were suggested and derived from the mathematical relations, corresponding to the respective measurands, and the measuring quantities by calculating each sensitivity coefficient of the quantities. Based on these models, the uncertainty of the tensile properties was evaluated from the experimental data of SUS316LN determined according to ISO 6892.

Measurement of Micro-Tensile Properties using ESPI technique (ESPI 기법을 이용한 미소 인장 특성 추정)

  • Huh, Yong-Hak;Kim, Dong-Il;Yoon, Kyung-Jin;Kim, Koung-Suk;Oh, Chung-Seog
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.5
    • /
    • pp.90-97
    • /
    • 2001
  • An electronic speckle pattern interferometry (ESPI) system for measuring tensile properties under micro-tensile testing has been developed. The system consists of an optical system and an image processing system. In the optical system, optical components for measurement of in-plane deformation are arranged on the path of He-Ne laser. In the image processing system, the window-based program for acquiring speckle pattern interferometric image was developed and deformation in a small specimen is continuously evaluated during the test. Using this system, tensile strain of copper foil was measured during tensile testing. Tensile specimen had the thickness and width of 22 and 500 ${\mu}{\textrm}{m}$, respectively. Tensile properties, including the elastic modulus, yielding strength and tensile strength, of the copper were evaluated and also plastic exponent and coefficient in the Ramberg-Osgood relationship were evaluated from the stress-strain curve.

  • PDF

Measurement of mechanical properties of SU-8 thin film by tensile testing (단축 인장에 의한 SU-8박막의 기계적 물성 측정)

  • 백동천;박태상;이순복;이낙규
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.2
    • /
    • pp.23-26
    • /
    • 2004
  • Thin film is one of the most general structures used in micro-electro-mechanical systems (MEMS). To measure the mechanical properties of SU-8 film, tensile testing was adopted which offers not only elastic modulus but also yield strength and plastic deformation by load-displacement curve. Tensile testing system was constructed with linear guided servo motor for actuation, load cell for force measurement and dual microscope for strain measurement.

  • PDF

Calculation of Design parameter of Si3N4 for Engineering part through the Measurement of Tensile strength (인장강도 시험을 통한 질화규소 소재의 설계계수 계산)

  • Choi, Young-Min;Lee, Jae-Do;Ko, Jun
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.6
    • /
    • pp.709-717
    • /
    • 1996
  • Design parameter of Si3N4 for engineering part could be calculated through the measurement of tensile strength with cylindrical specimen($\Phi$=7.15, ι=110mm) Relative densities of Si3N4 test specimen prepared by pressure-less sintering (PLS) and sinter/HIP were 98.5 and 99.2% respectively. Tensile strength of Si3N4 was 378 MPa for PLS and 509 MPa for sinter/HIP. By the Weibull statistic Design parameter such as Weibull modulus m=8-12 could be calcuated. Fracture strength of Si3N4 related to volume could be effectively pridicted by using Weibull theory.

  • PDF

Development of Tensile Strength Measurement Technique on Compacted Fine-Grained Soils (다짐된 세립토의 인장강도 측정법의 개발)

  • Kim, Tae-Hyung;Kim, Chan-Kee;Yun, Jung-Man;You, Seung-Kyong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1538-1545
    • /
    • 2005
  • Theoretical and experimental result studies of the unconfined penetration test (UP) method are conducted to suggest a new test method by improving the UP method for determination of the tensile strength of compacted fine-grained soils. From the theoretical aspect, the tensile strength of the specimen is estimated from the maximum load by the theory of perfect plasticity with assumptions, sufficient local deformability and modified Mohr-Coulomb failure criterion. Experimentally, some factors including relative size of specimen-disc, disc diameter, and loading rate are needed more study, because these factors significantly affect the results of tensile strength. Improvement of the alignement between two discs and specimen in the UP test is also necessary to eliminate the error due to eccentrically loading.

  • PDF

A Study on Cavity Pressure and Tensile Strength of Injection Molding (사출성형에서 캐비티압력과 인장강도에 관한 연구)

  • Yoo, J.H.;Kim, H.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.6
    • /
    • pp.110-116
    • /
    • 1994
  • In this research, the tensile strength of molded parts and pressure distribution were analyzed to study the cavity filling stage and packing stage in injection molding. The measurement of cavity pressure was obtained by a data acquisition system with the installation of transducers in the cavity. Molded parts were tested by a universal testing machine to obtain the tensile strength. For the experimental work, the tensile strength of molded parts increased with longer packing time and exact freezing time of the gate was obtained by a cavity pressure curve. In addition, the effect of packing did not occur and tensile strength was almost constant after early 1.5 sec of the freezing time of gate. Density tended to be higher about 0.2% due to a larger degree of mold temperature and melt temperature. Also, changing pressure in the cavity was effectively sensed. Thereafter, the possibility of the development of pattern recognition expert system was confirmed on the basis of the experimental results.

  • PDF