• Title/Summary/Keyword: tendons

Search Result 527, Processing Time 0.023 seconds

Flexural Behavior of Continuous Composite Bridges with Precast Concrete Decks

  • Chung, Chul-Hun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.625-633
    • /
    • 2003
  • For the construction of open-topped steel box girder bridges, prefabricated concrete slab could offer several advantages over cast-in-situ deck including good quality control, fast construction, and elimination of the formwork for concrete slab casting. However, precast decks without reinforcements at transverse joints between precast slabs should be designed to prevent the initiation of cracking at the joints, because the performance of the joint is especially crucial for the integrity of a structural system. Several prestressing methods are available to introduce proper compression at the joints, such as internal tendons, external tendons and support lowering after shear connection. In this paper, experimental results from a continuous composite bridge model with precast decks are presented. Internal tendons and external tendons were used to prevent cracking at the joints. Judging from the tests, precast decks in negative moment regions have the whole contribution to the flexural stiffness of composite section under service loads if appropriate prestressing is introduced. The validity of the calculation of a cracking load fur serviceability was presented by comparing an observed cracking load and the calculated value. Flexural behavior of the continuous composite beam with external prestressing before and after cracking was discussed by using the deflection and strain data.

Bilateral Digital Extensor Hypoplasia Correction: A Case Report and Systematic Review

  • Marudeen Aivaz;Esperanza Mantilla-Rivas;Ashleigh Brennan;John Thomas;Elizabeth L. Malphrus;Monica Manrique;Albert K. Oh;Gary F. Rogers
    • Archives of Plastic Surgery
    • /
    • v.50 no.2
    • /
    • pp.177-181
    • /
    • 2023
  • Digital extensor hypoplasia (DEH) is a rare malformation that presents with loss of active finger extension at the metacarpophalangeal (MCP) joints. Descriptions of optimal treatment and outcomes in this population are sparse. We describe successful operative treatment of a child with DEH involving the extensor digitorum communis, extensor digiti minimi, and the extensor indicis proprius tendons. The 5-year-old male patient was referred for severe limitation on bilateral finger extension since birth. He had been previously diagnosed with arthrogryposis and managed conservatively. Due to lack of improvement, magnetic resonance imaging was done evidencing hypoplasia/aplasia of the extensor tendons. The patient underwent successful tendon transfers using extensor carpi radialis longus to the common extensor tendons, and one hand required an additional tenolysis procedure. 2 years postoperatively, his MCP position and finger extension are markedly improved, and he is able to grip objects without limitation or difficulty. The patient returned to full activity without restriction.

Strengthening Design Using Rating Factor Considering Increment of Tendon Force for Two-Span Steel-concrete Composite Bridges Strengthened by Straight External Tendons (직선배치된 외부 긴장재로 보강된 2경간 강합성교의 증가 프리스트레스력을 고려한 내하율 산정식을 이용한 보강설계)

  • Choi, Dong-Ho;Yoo, Hoon;Kim, Yong-Sik;Kim, Sung-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.153-164
    • /
    • 2009
  • In this paper, a method of increasing in load-carrying capacity is shown in two-span steel-concrete composite bridges strengthened by external tendons. An analytic expression for the increment of tendon force under external loads is derived using virtual work method for straight external tendons and a new rating factor equation is proposed. Considering the initial tendon force and its increment under external loads, an analytic procedure has been developed to calculate the number of tendons and the initial tendon force from the proposed rating factor equation. This method is used to verify a validity and rationality for an existing two-span composite steel-concrete bridge.

An Experimental Study on Bond Characteristics of FRP Reinforcements with Various Surface-type (다양한 표면형상에 따른 FRP 보강재의 부착특성 실험연구)

  • Jung, Woo Tai;Park, Young Hwan;Park, Jong Sup
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4A
    • /
    • pp.279-286
    • /
    • 2011
  • FRP (Fiber Reinforced Polymer) tendons can be used as an alternative to solve the corrosion problem of steel tendons. Material properties of FRP tendons-bond strength, transfer length, development length-must be determined in order to apply to concrete structures. First of all, in case of application for pretension concrete members with CFRP tendons, transfer length is an important characteristic. The bond of the material characteristics should be demanded clearly to apply to PSC structures prestressed with FRP tendons. This paper investigated on the bond characteristics of FRP reinforcements with various surface-type. To determine the bond characteristics of FRP materials used in place of steel reinforcement or prestressing tendon in concrete, pull-out testing suggested by CAN/CSA S806-02 was performed. A total of 40 specimens were made of concrete cube with steel strands, deformed steel bar and 6 different surface shape FRP materials like carbon or E-glass. Results of the bonding tests presented that each specimen showed various behaviors as the bond stress-slip curve and compared with the bond characteristic of CFRP tendon developed in Korea.

Sonoanatomic Variation of Pes Anserine Bursa

  • Imani, Farnad;Rahimzadeh, Poupak;Gharehdag, Farid Abolhasan;Faiz, Seyed Hamid Reza
    • The Korean Journal of Pain
    • /
    • v.26 no.3
    • /
    • pp.249-254
    • /
    • 2013
  • Background: The pes anserine bursa lies beneath the pes anserine tendon, which is the insertional tendon of the sartorius, gracilis, and semitendinosus muscles on the medial side of the tibia, but it can lie in different sites in the medial knee. Accurate diagnosis of the position of the bursa is critical for diagnostic and therapeutic goals. The aim of this study was to evaluate sonoanatomic variations of the pes anserine bursa in the medial knee. Methods: One hundred seventy asymptomatic volunteers were enrolled in this study. Using ultrasound imaging (transverse approach, 7-13 MHz linear array probe) the sonoanatomic position of the pes anserine bursa and its relation to the pes anserine tendon were evaluated. Additionally, we evaluated the sonoanatomic variation of the saphenous nerve. Results: The position of the pes anserine bursa was between the medial collateral ligament and the pes anserine tendons in 21.2%/18.8% (males/females) of subjects; between the pes anserine tendons and the tibia in 67.1%/64.7% (m/f); and among the pes anserine tendons in 8.2%/12.9% (m/f). No significant differences in the position of the bursa existed between males and females. The saphenous nerve was found within the pes anserine tendons in 77.6%/74.1% (m/f) of subjects, but outside the pes anserine tendons in 18.8%/15.3% (m/f). Visibility of sonoanatomic structures was not related to either gender or BMI. Conclusions: Ultrasound provides very accurate information about variations in the pes anserine bursa and the saphenous nerve. This suggests that our proposed ultrasound method can be a reliable guide to facilitate approaches to the medial knee for diagnostic and therapeutic objectives.

Evaluation of Reinforcement Effect of Deteriorated PSC Beam through Cutting Its External Tendons (외부강선 파단실험을 통한 노후 PSC 교량의 보강효과 평가)

  • Park, Chang-Ho;Lee, Byeong-Ju;Lee, Won-Tae;Ku, Bon-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.178-186
    • /
    • 2005
  • In this study, the PSC girder bridge retrofitted with external tendons is tested to verify the strengthening effects. We measure the variations of the displacement and strain at mid-span of each beam as external tendons are removed in sequence. The structural behavior of the bridge are examined using controlled truck load tests for the systems before and after all external tendons were removed. From the test results, the characteristics of structural behavior of the bridge do not change significantly, but the natural frequency is decreased after the external tendons are removed. The strengthening effects of bridges can be exactly estimated by analytical methods some extent. As a result of this study, when a PSC girder bridge is deteriorated, the bridge can be retrofitted effectively by External Prestressing Strengthening Method, and the strengthening effects can be predicted through accurate structural analysis.

Theoretical Assessment of Flexural Strength of Unbonded FRP Prestressed Concrete Beams (비부착 FRP 프리스트레스트 콘크리트보의 휨내력 이론 산정)

  • Heo, Seo-Young;Lee, Cha-Don;Jeong, Sang-Mo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1045-1048
    • /
    • 2008
  • Fiber reinforced polymer (FRP) usually exhibits inherent brittleness under tensile stress. Application of FRP tendons to concrete beam leads to undesirable flexural behavior due to limited ductility compared to prestressed concrete beam with steel tendons. It has been experimentally observed that partial improvement of flexural behavior can be achieved by releasing FRP tendons' strain by unbonding FRP tendons. In order to estimate and apply the degree of improvement to the design, reasonable yet practical model predicting flexural strength as well as overall flexural behavior of unbonded FRP prestressed concrete beam is needed. In this study, an elaborated model in describing curvature distributions and flexural strength at ultimate stage of unbonded FRP tendons is described. There have been close agreements on the flexural strength of the FRP prestressed concrete beam between the predictions by nonlinear computer program and by the model.

  • PDF

Fatigue Capacity of Concrete Beams Prestressed with Partially Bonded CFRP Tendons (CFRP 긴장재로 긴장된 부분비부착 콘크리트 보의 피로 성능)

  • Jeong, Sang-Mo;Lee, Cha-Don;Park, Sang-Yeol;Jeong, Yo-Sok;Park, Dong-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.333-336
    • /
    • 2008
  • CFRP tendons have been attempted in concrete structures as a substitute for steel tendons considering their many advantages such as the corrosion-resistance, light weight etc. However, the elastic behavior up to failure is likely to result in ductility problems. To overcome such problems, prestress concrete beams with partially bonded tendons have been developed and suggested. In this new system, the un-bonded part near the mid-span contributes to the improvement of ductility. And the bonded parts at both ends play a role as a safe anchorage. According to the previous research on the static behavior, the suggested method has demonstrated enough ductility and strength. However it is essential to verify the long-term safety for repetitive fatigue loads under service states. For this purpose, flexural fatigue loading tests were carried out in this research. This paper includes an experimental investigation on the static load-carrying capacities of the beams with or without fatigue tests. The results showed that the beams prestressed with partially bonded CFRP tendons possessed good fatigue capacity under the constant cyclic loads.

  • PDF

Extensor Tendon Gliding Surface Reconstruction Using Adipoascia Extended Free Anterolateral Thigh Flap - Case Report - (지방 근막 피판이 연장된 전외측 대퇴 유리 피판술을 이용한 신전건 활주막의 재건 - 증례 보고 -)

  • Lee, Sin-Chul;Eun, Seok-Chan;Baek, Rong-Min
    • Archives of Reconstructive Microsurgery
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2010
  • Purpose: In reconstructing a defect on the dorsum of the hand, there are many cases of extensor tendons exposed or even missing. The repaired or reconstructed tendons need relevant gliding environment for good functional recovery. The anterolateral thigh flap offers a vascular fascial component with large amounts that can be used for covering exposed tendons and we report a unique case of single-stage hand dorsum and gliding surface reconstruction. Methods: A 35-year-old man had severe post-traumatic scarring in his left dorsal hand and coverage of the flap with split-thickness skin graft has been done before. After scarred skin excision and extensor tendon graft for missed part, a free anterolateral thigh adipofascial flap was used to resurface the hand dorsum and to reconstruct a two-layer gliding surface of the extensor tendons. The extensor tendons were wrapped in the fascial component with the fat layer inside. Results: He had an uneventful postoperative course without infection, dehiscence and flap necrosis. Good overall functional recovery and tendon excursion were observed. He was also satisfied with postoperative appearance. Conclusion: A free anterolateral thigh adipofascial flap was used successfully for reconstruction of a two-layer tendon gliding surface to treat a patient with severe scarring in the dorsal hand.

  • PDF

Effect of platelet-rich plasma in Achilles tendon allograft in rabbits

  • Seok-Hong Park;Dong-Yub Kim;Won-Jae Lee;Min Jang;Seong Mok Jeong;Sae-Kwang Ku;Young-Sam Kwon;Sungho Yun
    • Journal of Veterinary Science
    • /
    • v.25 no.2
    • /
    • pp.22.1-22.15
    • /
    • 2024
  • Background: Achilles tendon is composed of dense connective tissue and is one of the largest tendons in the body. In veterinary medicine, acute ruptures are associated with impact injury or sharp trauma. Healing of the ruptured tendon is challenging because of poor blood and nerve supply as well as the residual cell population. Platelet-rich plasma (PRP) contains numerous bioactive agents and growth factors and has been utilized to promote healing in bone, soft tissue, and tendons. Objective: The purpose of this study was to evaluate the healing effect of PRP injected into the surrounding fascia of the Achilles tendon after allograft in rabbits. Methods: Donor rabbits (n = 8) were anesthetized and 16 lateral gastrocnemius tendons were fully transected bilaterally. Transected tendons were decellularized and stored at -80℃ prior to allograft. The allograft was placed on the partially transected medial gastrocnemius tendon in the left hindlimb of 16 rabbits. The allograft PRP group (n = 8) had 0.3 mL of PRP administered in the tendon and the allograft control group (n = 8) did not receive any treatment. After 8 weeks, rabbits were euthanatized and allograft tendons were transected for macroscopic, biomechanical, and histological assessment. Results: The allograft PRP group exhibited superior macroscopic assessment scores, greater tensile strength, and a histologically enhanced healing process compared to those in the allograft control group. Conclusions: Our results suggest administration of PRP on an allograft tendon has a positive effect on the healing process in a ruptured Achilles tendon.