• 제목/요약/키워드: temporary storage

검색결과 98건 처리시간 0.033초

누출 사고 완화를 위한 임시 저장 시설에 관한 연구 (A Study on the Temporary Storage Facility for Mitigating the Leakage Accident)

  • 송현오;이창준
    • 한국안전학회지
    • /
    • 제35권3호
    • /
    • pp.1-5
    • /
    • 2020
  • The leakage accident from a storage tank in an oil refinery plant occurred in April 2014 and the total loss is KRW 18 billion. This accident has prompted many companies to develop their own mitigation system to minimize the loss of the leakage accident. The aim of this study is to design the temporary storage facility system for dealing with leakage accidents. The basic concept of this system is that the leakage fluid of a hazardous material flows into a temporary storage tank and this is transferred to a spare tank by a pump as avoiding the overflow of a temporary storage tank. In order to design this system, the leakage velocity and quantity according to time series should be evaluated. In addition, a proper pump capacity should be determined to avoid repeating the pump switching on and off frequently. In this study, the benzene tank is selected to verify the efficacy of this system. This study can play a critical role to provide a guideline for designing a new system.

취급, 수송 및 저장능력을 고려한 임시 재고의 저장 공간 할당 (Allocating Storage Spaces for Temporary Inventories Considering Handling, Transportation, and Storage Capacities)

  • 원승환;김갑환
    • 한국경영과학회지
    • /
    • 제31권3호
    • /
    • pp.11-25
    • /
    • 2006
  • Space may be a scarce resource in manufacturing shops, warehouses, freight terminals, and container terminals. This Paper discusses how to locate temporary storage Inventories In limited storage areas. A typical inventory is delivered from the location of the preceding process to the storage area and stored In the storage area during the certain period of time. And it may be relocated from the storage position to another. Finally. it is delivered from the final storage area to the location of the next process. Because this logistic process for an inventory requires handling activities, transportation activities, and storage spaces, the limitation in capacities of handling equipment, transportation equipment, and storage space must be considered when allocating spaces to the inventory. This problem Is modeled as a multicommodity minimal cost flow problem. And a heuristic algorithm for the Problem is proposed. Numerical experiments are presented to validate the mathematical model and the heuristic algorithm.

조립식 저류형 침투시설의 설계 및 공간적용 효과분석 (Design and Effectiveness Analysis of prefabricated Storage-type infiltration facility)

  • 이태구
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: This study has developed economical and environmentally friendly storage type infiltration facilities that securing storage space inside the infiltration facility. It focused on preventing flooding rainfall as well as securing more groundwater through rainwater infiltration that is valuable for the dry season. In addition, this study compares the installation cost of the storage-type infiltration facility to the cost of the conventional rainwater management facilities to demonstrate the economic efficiency of the storage-based infiltration facility. Method: Unit infiltration of this facility is calculated and when it was applied to a certain capacity, the amount of countermeasures are proposed in case study. Result: Unit infiltration of it is $0.2541m^3/hr$ and un it Temporary storage of it is $1.054m^3/m$. As a result, the infiltration effect of this facility is $1.306m^3/hr$. The cost was approximately 30% reduction in time to apply the storage type infiltration facility as compared with the case to apply the existing penetration of the facilities. Since the penetration of the existing facilities is smaller than that and it has much securing volume to process the same the amount of countermeasures. Therefore, it is determined that the cost significantly increases in material cost part. On the other hand, storage type infiltration facility is installed a small quantity because Unit Temporary storage and infiltration are bigger than that. So, it occurred to reduce material and installation costs.

건설가설공사의 표준기술분류체계 구축 (Development of Technical Breakdown Structure Standard in Temporary Works)

  • 박준모;김옥규;박길범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.162-163
    • /
    • 2013
  • A temporary work are lifting equipment that tower crane or lift, and temporary architectures that office building and storage in construction site. And it is main construction work that built and used temporarily like to a scaffolding, a walk plate, and a formwork. This study is to adjust breakdown structure of temporary work to introduce technical tendency. With a site manager, it is collected a detailed statement and compared. As a result to break down a tendency that temporary equipment, additional function, and direct work of temporary technique, first, existing detail technical indexes that group I, group J, group K, and group L are classified. Second, due to set up and manage to main agents in case of existing detail technical indexes that B1, B2, it is not wrong to classify. But, it is somewhat different, and therefore adjust it to same level. Finally, as a technical tendency that temporary equipment, additional function, and direct work of temporary technique, it is adjusted the others.

  • PDF

GAMMA-SPECTROMETRY IN ENVIRONMENTAL MONITORING OF NUCLEAR POWER

  • Cechak, Tomas;Gerndt, Josef;Kluson, Jaroslav;Musilek, Ladislav;Thinova, Lenka
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.203-206
    • /
    • 2001
  • The mathematical processing (unfolding) of pulse height spectra from a scintillation detector helps to calculate the photon fluence rate energy distribution in a measured photon field. The data processing is based on the knowledge of detection system response function and directional dependence respectively. The experimental results of the photon fields measurements in the vicinity of the spent fuel temporary storage and inside the storage hall are presented. The containers Castor 440 are used for temporary storing of the burnt up fuel assemblies in the Czech nuclear power plant Dukovany. A set of periodical measurements was performed in order to get basic information on the time dependence of the photon fields spatial distributions and spectral characteristics in the temporary storage hall and its vicinity. The photon fields were measured by the scintillation system. The obtained photon fields spatial distributions and spectral characteristics present the information on the radiation hazard in the storage.

  • PDF

후쿠시마 원전 사고 이후 일반인의 방사선학적 안전성 확보를 위한 제염폐기물 임시저장시설 이격거리 평가 (Evaluation of Separation Distance from the Temporary Storage Facility for Decontamination Waste to Ensure Public Radiological Safety after Fukushima Nuclear Power Plant Accident)

  • 김민준;고아라;김광표
    • 방사성폐기물학회지
    • /
    • 제14권3호
    • /
    • pp.201-209
    • /
    • 2016
  • 후쿠시마 원전사고 이후 광역의 방사성 오염부지가 발생되었으며, 이에 대한 제염작업으로 인하여 다량의 제염폐기물이 발생하였다. 일본에서는 이를 보관하기 위하여 각 지역에 임시저장시설이 운영되고 있으며, 이들 시설들은 피난지시해제가 이루어진 지역의 일반인에 대하여 방사선학적 영향을 미칠 것으로 판단된다. 본 연구에서는 임시저장시설 인근에 거주하는 일반인의 방사선학적 안전성 확보를 위하여 임시저장시설 특성에 따른 거리별 공간 방사선량률 및 선량제한치를 만족하는 임시저장시설로부터의 이격거리를 평가하였다. 이를 위해 임시저장시설의 형태 및 크기, 복토 두께 등을 고려하였으며, MCNPX를 이용하여 방사선량률을 평가하였다. 복토에 의한 차폐효과는 두께가 10 cm일 때 68.9%, 30 cm일 때 96.9%, 50 cm 일 때 99.7%로 나타났다. 임시저장시설 형태에 따른 공간 방사선량률은 지상 보관형일 때 가장 높게 나타났으며, 이어서 반지하 보관형, 지하 보관형일 순으로 나타났다. 임시저장시설 크기에 따른 공간 방사선량률은 $5{\times}5{\times}2m$ 시설을 제외한 시설에 대하여 유사하게 나타났다. 이는 임시저장시설 내 적재된 제염폐기물에 의하여 자기차폐가 이루어지기 때문이다. 최종적으로 크기가 $50{\times}50{\times}2m$이고, 복토가 없는 임시저장시설의 경우, 지상 보관형의 평가된 이격거리는 14 m(최소농도), 33 m(최빈농도), 57 m(최대농도)이며, 반지하 보관형의 이격거리는 9 m(최소농도), 24 m(최빈농도), 45 m(최대농도), 지하보관형의 이격거리는 6 m(최소농도), 16 m(최빈농도), 31 m(최대농도)로 나타났다.

A STUDY ON EROSION (CAUSES AND REMEDIES) BASED ON HYDROLOGICAL DATA

  • K.M. Ibe, Sr;H. Krynen
    • Water Engineering Research
    • /
    • 제2권4호
    • /
    • pp.269-276
    • /
    • 2001
  • The project concentrates on an hydrological analysis. The analysis consists of rainfall, infiltration, Determination of runoff and sediment yield. The risque of erosion and the control measures are related to the slopes and land use. Therefore the first approach to erosion must be correct land use based on land classification. Basically there are two types of mechanical protection works; Drainage and Storage. Realization of a drainage system will be very costly and therefore temporary storage is preferred. For farmland in flat areas hardly any measures are needed. For farmland on slopes temporary storage can be effected by applying tillage with ridges within contour bunds. Along roads infiltration pits should be constructed and in areas with houses, the solution to avoid runoff will be water harvesting.

  • PDF

공동주택단지에서의 빗물저수조 설치 및 활용방안 연구 (A study on the application and construction of a rainwater storage tank in apartment complex)

  • 이원열;정상민;신덕;이철현;한무영
    • 한국건축시공학회지
    • /
    • 제5권4호
    • /
    • pp.165-171
    • /
    • 2005
  • Nowadays, a source of all water, which has been spent by a lot of people, is the rainwater The rainwater is directly relating human being' life. According to how to use rainwater. human being' life is abundant or poor. Due to the lack of underground filtration quantity, the water circulation of the city is discontinued and the underground ecosystem is destroyed. This study suggest that the unused underground space of building and temporary structure can be used into rainwater storage tank in the facility to use rainwater. Moreover, in this study, while the building is constructed, It is showed that the water used in construction can be replaced in the rainwater.

저장 탱크용 임시전력설비의 보호계전기 정정에 관한 연구 (A Study on the Correction of Protection Relay of Temporary Electric Power Installations for Storage Tank)

  • 손석금
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.562-567
    • /
    • 2020
  • 본 논문은 저장 탱크용 임시전력설비를 보호하기 위한 목적으로 특히 변압기를 감시하고 절연파괴 등과 같은 고장을 차단하고 보호하기 위한 보호계전기 정정에 관한 연구이다. 전력계통에 단락 또는 지락고장 등과 같은 이상이 발생하였을 때 이를 검출하여 고장이 발생한 기기 및 설비를 신속하게 차단하고 전력계통으로부터 분리하여 전력공급에 지장이 없도록 하여야 한다. 전력계통의 이상 상태를 빠르고 정확하게 감지할 수 있는 보호계전기의 정정이 중요하다. 또한 보호협조를 위해 고장종류와 고장의 원인을 정확히 적용한 고장전류 계산이 보호계전기 정정에 가장 중요한 요소이다. 저장 탱크용 임시전력설비 보호를 위해 적용하는 과전류계전기, 지락과전류계전기, 부족전압계전기, 지락과전압계전기 등이 보호협조가 가능하도록 보호계전기 정정 방법에 대해 연구하였다.