• Title/Summary/Keyword: temporary pacing

Search Result 11, Processing Time 0.018 seconds

Respiratory Assist by Use of Electrical Diaphragmatic Pacing (전기자극에 의한 횡격막 조율을 이용한 호흡보조장치)

  • 오중환;김은기;서재정;박일환;김부연;이상헌;이종국;이영희
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.441-446
    • /
    • 2001
  • Background: Electrical breathing pacing has many advantages over mechanical ventilation. However, clinically permanent diaphragmatic pacing has been applied to limited patients and few temporary pacing has been reported. Our purpose is to investigate the feasibility of temporary electrical diaphragm pacing in explothoracotomy canine cases. Methods: Five dogs were studied under the general anesthesia. Left 5th intercostal space was opened. Self designed temporary pacing leads were placed around the left phrenic nerve and connected to the myostimulator. Chest wall was closed after tube insertion with underwater drainage. Millar catheter was introduced to the aorta and right atrium. Swan-Ganz catheter was introduced to the pulmonary artery. When the self respiration was shallow with deep anesthesia, hemodynamic and tidal volume were measured with the stimulator on. Results: Tidal volume increased from 143.3$\pm$51.3 ml to 272.3$\pm$87.4 ml(p=0.004). Right atrial diastolic pressure decreased from 0.7$\pm$4.0 mmHg to -10.5$\pm$4.7 mmHg(p=0.005). Pulmonary arterial diastolic pressure decreased from 6.1+2.5 mmHg to 1.2$\pm$4.8 mmHg(p<0.001). The height of water level in chest tube to show intrathoracic pressure change was from 10.3$\pm$6.7cmH$_{2}$O to 20.0$\pm$5.3 cmH$_{2}$O. Conclusion: Temporary electrical diaphragmatic pacing is a simple method to assist respiration in explothoracotomy canine cases. Self designed pacing lead is implantable and removable. Negative pressure ventilation has favorable effects on the circulatory system. Therefore, clinical application of temporary breathing pacing is feasible in thoracotomy patients to assist cardiorespiratory function.

  • PDF

Transcutaneous Cardiac Pacing in a Dog with Diltiazem Intoxication (딜티아젬 중독증 이환견에서 경피용 체외심박조절기의 적용 증례)

  • Lee, Seung-Keun;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.26 no.2
    • /
    • pp.166-169
    • /
    • 2009
  • An 11-year-old male Beagle, weighing 10.5 kg, was presented with sudden bradyarrhthmia and severe hypotension after incidental ingestion of diltiazem. The dog was treated with intravenous(IV) isotonic crystalloid solution, atropine, calcium gluconate, dobutamine, glucagon and gastric lavage under the aid of temporary transcutaneous cardiac pacing. With the short-term use of transcutaneous cardiac pacing and medical treatment, the heart rhythm and the condition of the patient were stabilized.

Cardiac Surgery for the Patient with VVI Unipolar Pacing System -One Case- (VVI 단극유도의 심박조율치를 가진 환자의 개심술 -1례 치험-)

  • 정해동;최종범;최형호
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.398-401
    • /
    • 1998
  • A 56-year-old female with a permanent unipolar pacing(VVI) system underwent elective coronary bypass surgery and mitral valve replacement. Because the unipolar sensing is subject to considerable nonmyocardial electrical noise, the pacing function may be disturbed by the use of electrocautery. Temporary atrial and ventricular bipolar epicardial leads and external generator were used for maintaining A-V sequential pacing during the use of electrocautery. Before aortic cross-clamp was released after cardiac operation, regular cardiac rhythm could spontaneously be resumed with an integrated cardioplegic strategy, avoiding the use of defibrillator

  • PDF

Open Heart Surgery in Infancy (영아기 개심술)

  • 이상호
    • Journal of Chest Surgery
    • /
    • v.28 no.1
    • /
    • pp.11-17
    • /
    • 1995
  • Fourty-three infants underwent intracardiac repairs within the first 12 months of life. Mean age was 7 months and mean weight was 6.7 kg. A quarter of them were below 5 kg. Overall mortality including complex anomalies was 17.9%. Thirty-four infants with a ventricular septal defect[VSD were treated. Three infants[8.8% died in the early postoperative period, but only one[3.7% of the infants without having associated lesions was dead. VSD was repaired either by the incision on the right atrium, pulmonary artery, or right ventricle. Postoperative right bundle branch block[RBBB occurrence were different according to the approach: 30.8 % in pulmonary arteriotomy, 37.5 % in atriotomy, and 42.8 % in ventriculotomy. Surgically induced heart block did not occur in any patient, but 10 had temporary arrhythmia, and 11 patients were under temporary pacing from one day to 4 days without any persisting rhythm disturbances. Pulmonary hypertension was present in 29 infants preoperatively, and seven of them developed postoperative elevation of the pressure. Infants complicated with pulmonary hypertensive crisis were managed successfully. Inotropics were necessary in 55.8 % of the infants and vasodilators in 37.2 %. Platelet transfusion were needed in 10 cases who required 272 ml in average, but one who died from sepsis consumed 5,370cc of platelets. And we discuss complications and causes of deaths.

  • PDF

The prognostic implication of postoperative ECG changes in congenital heart surgery (술후 심전도 변화가 예후에 미치는 영향에 관한 고찰 -선천성 심질환을 중심으로-)

  • 정황규
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.363-373
    • /
    • 1986
  • Even though the pathogenesis is still controversial, electrocardiographic changes after congenital open heart surgery depend on various etiologic factors. Author reviewed 261 cases of congenital open heart surgery patient experienced in the Dept. of Thoracic & Cardiovascular Surgery, Pusan National University Hospital, since July, 1981 to Sept., 1985. The results were summarized as followed: 1. The age distribution was from 3 to 29 years old with mean age 10.8 years. And the most frequent congenital heart defect we had done operation was VSD. 2. Preoperatively, the most frequent ECG finding was abnormal QRS complex and postoperatively the most frequent ECG change was arrhythmia. 3. The most frequent arrhythmia before operation was intraventricular conduction disturbance. 4. Right ventriculotomy incision produced the more frequent abnormal ECG changes postoperatively than right atriotomy or pulmonary arteriotomy. 5. According to the operative technique, outflow patch graft of TOF repair produced the highest frequency of ECG changes after operation, and in comparing simple and patch closure of VSD, the latter was higher frequency of ECG changes, in valvotomy and infundibulectomy of PS, the latter was higher too. 6. The common symptom and signs in abnormally ECG changed patients after operation were palpitation, dyspnea, congestive heart failure and murmur in this order., 7. The longer the time of CPB, the more number of abnormally ECG changed patients had been developed after operation. 8. The most of postoperative ECG changed patients recovered spontaneously or with only medication and were clinically insignificant. And the rest other minor group recovered with temporary pacing. Eight cases out of 261 [3.1%], these with abnormal QRS complex and arrhythmia couldn`t recover in spite of every effort and eventually succumbed.

  • PDF

Complete A-V Block 3 Months after Total Correction of Tetralogy of Fallot (활로 4징증의 근치수술후의 원격 방실전도 차단)

  • 송요준
    • Journal of Chest Surgery
    • /
    • v.11 no.3
    • /
    • pp.326-332
    • /
    • 1978
  • There appears some conduction defects frequently after total correction of Tetralogy of Fallot. Common defect is right bundle branch block due to surgical intervention. We experienced complete A-V block which occured 3 months later after total correction of Tetralogy of Fallot in a 8 year old boy. The patient was completely free of any A-V block after the operation for 3 months, and sudden onset of A-V block with coupled premature ventricular contractions resulted him in shock state during the attack of severe bronchopneumonia for 4 days prior to the second visit. Emergency implantation of Cordis demand type temporary pacemaker was necessary to control the complete heart block with bradyarrhythmia and frequent ventricular fibrillation. Permanent cardiac pacemaker was implanted two weeks later as indicated with Cordis Stanicor lambda demand pacemaker, and the patient was discharged uneventfully on the 8th post implantation day with the heart rate of 72/min. Another 3 months after the implantation, the patient was transported to this hospital as dead on arrival after an accidental fall from a 2 meter height, and all possible cardiopulmonary resuscitation was performed for 60 minutes at the emergency room in vain. Autopsy was done to find out the cause of sudden death and the etiology of complete heart block. Microscopic focal infarctions with scar formation were noted along the course of conduction system in the interventricular septum, which might be the main cause of complete heart block during the attack of severe bronchopneumonia complicated with acute bacterial endocarditis. The tip of the pacemaker wire was slipped from the granulation scar at the apex of the right ventricular cavity, and this might be the direct cause of pacing failure and death.

  • PDF

Implantation of a permanent pacemaker through the coronary sinus in a patient who underwent mechanical valve replacement for infective endocarditis with a complete atrioventricular block (완전방실차단을 동반한 감염성 심내막염 환자에서 판막치환술 후 관정맥동을 통해 좌심실을 조율하는 심박조율기 시술)

  • Jo, Kwan Hoon;Kim, Inho;Ann, Soe Hee;Oh, Yong Seog
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.2
    • /
    • pp.113-116
    • /
    • 2014
  • A 52-year-old man was referred to our hospital due to fever and myalgia that occurred 2 weeks earlier. He showed a complete atrioventricular block on his electrocardiogram, and his vital signs were unstable. On his transthoracic echocardiograph, the 1.5 cm vegetation in the aortic valve with severe aortic regurgitation suggested infective endocarditis. His transesophageal enchocardiograph showed abscess in his mitral-aortic intervalvular fibrosa and vegetation was suspected on his anterior mitral valve leaflet. The patient underwent an emergent operation for valve replacement with temporary epicardial pacing. Intraoperatively, the septal leaflet of his tricuspid valve was injured during the debridement of the abscess pocket that was extended to the membranous septum. The aortic, mitral, and tricuspid mechanical valves were replaced with annular reconstruction without complications. After 14 days of intravenous antibiotics, we successfully changed the epicardial pacemaker into a transvenous DDD-type permanent pacemaker by placing a left ventricular lead via the coronary sinus and an atrial lead in the right atrium appendage. The patient was discharged in a tolerable state and was examined uneventfully in our hospital's outpatient clinic for 8 months.

A case of various clinical aspects associated with cardiotoxicity after glufosinate poisoning (글루포시네이트 중독 후 심장독성의 다양한 임상경과를 보인 1례)

  • Kim, Seon Tae
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.2
    • /
    • pp.133-138
    • /
    • 2021
  • Glufosinate-containing herbicides is a non-selective herbicide commonly used worldwide. As the use of them increased gradually since paraquat was banned in 2012, the number of suicides by their ingestion is also increasing continuously. Complications of glufosinate-containing herbicide poisoning include various central nervous system (CNS) toxicities such as convulsions, loss of consciousness, memory impairment, and respiratory depression, which may be accompanied by hemodynamic changes such as bradycardia and hypotension. However, it is very rare that arrhythmias other than bradycardia occurred and Takotsubo cardiomyopathy was combined due to cardiotoxicity. A 71-year-old female patient was transferred to our hospital after ingesting 500 mL of glufosinate-containing herbicide and receiving 5 L of gastric lavage at a local hospital. A few hours later, she presented stuporous mentality, respiratory depression, and convulsions, and was accompanied by hypotension and bradycardia. On the second day of admission, electrocardiogram (ECG) showed bradycardia and QTc prolongation with hemodynamic Instability. Accordingly, we conducted the early treatment with continuous renal replacement therapy (CRRT) and the application of temporary cardiac pacemaker. An echocardiogram demonstrated decreased ejection fraction (EF) and Takotsubo cardiomyopathy on the third day of admission. Then, she was discharged safely with conservative treatment. At the follow-up after 1 year, Takotsubo cardiomyopathy, EF and QTc prolongation were recovered on echocardiogram and ECG. Because cardiac toxicity after glufosinate-containing herbicide poisoning may cause life-threatening consequences, caution is required while treating the patient. Therefore, if electrocardiogram changes are seen in the elderly with a large amount of glufosinate herbicide ingestion, additional cardiac function test through echocardiography should be concerned, and early treatment through CRRT or artificial cardiac pacing should be considered.

Surgical Repair of Single Ventricle (Type III C solitus) (단심실 -III C Solitus 형의 수술치험-)

  • naf
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.281-288
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF

Surgical Repair for Ebstein's Anomaly (Ebstein 기형의 수술 -2례 보고-)

  • naf
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.289-296
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF