• Title/Summary/Keyword: temperatures

Search Result 14,807, Processing Time 0.033 seconds

The Experimental Study on the Resistance Forces and the Failure Temperatures of H-Shaped Steel Compressive Members by Elevated Temperatures (온도상승에 의한 H-형강 압축재의 내력과 파괴온도에 관한 실험적 연구)

  • Choi, Hyun Sik;Kang, Seong Deok;Kim, Jae Eok
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.2
    • /
    • pp.131-139
    • /
    • 2013
  • The object of this paper is to perform the experiments to investigate the relationship of the resistance forces and the failure temperatures on the failure behaviors of H-shaped steel compressive members. H-shaped members(SS400) were used for the test models and the tests for the elevated temperatures were performed by ISO 834 in FILK(Fire Insurers Laboratories of Korea). The local, overall buckling stresses and a yielding stresses for the failure temperatures were compared with the compressive stresses for the loading forces of test models, the yielding strength and elastic modulus reduction factor of the steel at a high temperature were based on the criteria of the EC3(Eurocode 3) Part1.2(1993). The slenderness ratio was fixed by 45.4 and the compressive forces corresponded with 50%, 70% and 80% of the yielding forces at the normal temperatures were chosen for the loading forces of the test models. The failure temperatures of the test models were investigated under three kinds of loading conditions. It was known that the resistance forces have come close to the yielding forces, not the elastic buckling loads evaluated by EC3 at the failure temperatures obtained from the tests which are related to the failure temperatures and the loading stresses.

Exposure to elevated temperatures and cooled under different regimes-a study on polypropylene concrete

  • Yaragal, Subhash C.;Ramanjaneyulu, S.
    • Advances in materials Research
    • /
    • v.5 no.1
    • /
    • pp.21-34
    • /
    • 2016
  • Fire is one of the most destructive powers to which a building structure can be subjected, often exposing concrete elements to elevated temperatures. The relative properties of concrete after such an exposure are of significant importance in terms of the serviceability of buildings. Unraveling the heating history of concrete and different cooling regimes is important for forensic research or to determine whether a fire-exposed concrete structure and its components are still structurally sound or not. Assessment of fire-damaged concrete structures usually starts with visual observation of colour change, cracking and spalling. Thus, it is important to know the effect of elevated temperatures on strength retention properties of concrete. This study reports the effect of elevated temperature on the mechanical properties of the concrete specimen with polypropylene fibres and cooled differently under various regimes. In the heating cycle, the specimen were subjected to elevated temperatures ranging from $200^{\circ}C$ to $800^{\circ}C$, in steps of $200^{\circ}C$ with a retention period of 1 hour. Then they were cooled to room temperature differently. The cooling regimes studied include, furnace cooling, air cooling and sudden cooling. After exposure to elevated temperatures and cooled differently, the weight loss, residual compressive and split tensile strengths retention characteristics were studied. Test results indicated that weight and both compressive and tensile strengths significantly reduce, with an increase in temperature and are strongly dependent on cooling regimes adopted.

Absorption of SO2 at High Temperatures by Ionic Liquids and the Absorption Mechanism

  • Tian, Shidong;Hou, Yucui;Wu, Weize;Ren, Shuhang;Qian, Jianguo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2791-2796
    • /
    • 2014
  • The capture of $SO_2$ at or close to the temperatures of real flue gas is much more attractive in application. In this work, two kinds of ionic liquids (ILs) based on lactate anion were used to absorb $SO_2$ at high temperatures from 100 to $120^{\circ}C$. The ILs show high absorption capacities of over one mol $SO_2$ per mol IL at $110^{\circ}C$. The absorption of $SO_2$ by the ILs based on lactate anion is reversible and the ILs can be reused for the capture of $SO_2$ at high temperatures with high absorption capacity and thermal stability. Furthermore, the absorption mechanism of $SO_2$ by the ILs was studied by FT-IR, $^1H$ NMR and $^{13}C$ NMR spectra. It has been found that there are strong chemical interactions between the ILs and $SO_2$. Also the absorption mechanism is different when there is water present in ILs compared to when there is not.

Temperature Control Freezers and Refrigerators in Department Stores & Supermarkets (백화점 및 대형할인매장의 냉장.냉동식품의 온도관리)

  • 노병의;빈성오
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.69-74
    • /
    • 2001
  • A study on temperature control of freezers & refrigerators in department stores and supermakets was conducted in Taegu are from July 15 through August 30 in order to determine how the temperature is effectively controled for food safety. Five departments and four supermarkets were selected randomly and fifty seven refrigerators and fifty nine freezers were inspected to observe temperature of thermometers and measure the temperature of the coolers by laser thermometer. The results are as follow; 1. Out of one hundred and sixteen coolers, eighty six (74.1%) were open type coolers and thirty (25.9%) were closed types (p<.05). 2. Twenty five (89.3%) of refrigerators and twenty three (82.1%) of freezers in department stores had thermometers and twenty seven refrigerators (93.1%) and twenty two (71%) of freezers in supermarkets had thermometers respectively (p<.01). 3. The measured temperatures of coolers increased in the afternoon to compared to the temperatures of them in the morning time (p<.01). The difference of temperatures of coolers between department stores and supermarkets was wider in the supermarkets and difference of temperatures of food items between refrigerators and freezers was wider in the refrigerators but the difference was not statistically significant. 4. The temperatures of forty four (84.6%) out of fifty two refrigerators within recommended ranges and those of forty two (93.3%) of forty five freezers higher than recommended ranges (p<.05).

  • PDF

Thermal Analysis of Nickel-Base Superalloys by Differential Scanning Calorimetry (시차주사열량측정법에 의한 니켈기 초내열 합금의 열분석)

  • Yun, Jihyeon;Oh, Junhyeob;Kim, Hongkyu;Yun, Jondo
    • Korean Journal of Materials Research
    • /
    • v.26 no.5
    • /
    • pp.235-240
    • /
    • 2016
  • Appropriate thermo-mechanical properties of nickel-based superalloys are achieved by heat treatment, which induces precipitation and solid solution hardening; thus, information on the temperature ranges of precipitation and dissolution of the precipitates is essential for the determination of the heat treatment condition. In this study, thermal analyses of nickel-based superalloys were performed by differential scanning calorimetry method under conditions of various heating rates of 5, 10, 20, or 40K/min in a temperature range of 298~1573K. Precipitation and dissolution temperatures were determined by measuring peak temperatures, constructing trend lines, and extrapolating those lines to the zero heating rate to find the exact temperature under isothermal condition. Determined temperatures for the precipitation reactions were 813, 952, and 1062K. Determined onset, peak, and offset temperatures of the first dissolution reaction were 1302, 1388, and 1406K, respectively, and those values of the second dissolution reaction were 1405, 1414, and 1462K. Determined solvus temperature was 1462K. The study showed that it was possible to use a simple method to obtain accurate phase transition temperatures under isothermal condition.

Effects of high temperatures and hygrothermals on the collapse characteristics of CFRP thin-walled laminates (고온 .senter dot. 고습환경이 CFRP 적층 원통부재의 압궤특성에 미치는 영향)

  • 곽훈이;김정호;양인영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.650-654
    • /
    • 1995
  • In this study, in order to measure energy-absorbing charactistics in collapse test of CFRP thin-walled laminates and interpretate the cause of decreasing age when collapse test is carried out under the environments of high temperatures and hygrothermals, the moisture absorbing behavior according to the variety of orientation angel is observed and collapse characteristics is compared with the influence of high temperatures and hygrothermals. Especially, we supposed to clearly understand reationship between collapse characteristics in proportion to the variety of orientation angel and moisture absorbing. The value of the maximum loading, mean loading,rate of energy absorption energy per unit volume and mass in CFRP thin-walled laminates on the high temperatures and hygrothermals is measured lower than under no moisture absorbing. The maximum collapse loading in dynamic impact test is taken measurement lower than in static collapse test regarding compared with collapse characteristics conformity with the variety of the CFRP circular laminates in high temperatures and hygrothermals. But the absorbed energy per unit mass and volume is almost same and the biggest amount of energy is shown in the CFRP circular laminates with orientation angel of 15 .deg.. Therefore, in the case of use to CFRP circular laminates with axisymmetric mode, CFRP thin-walled structal members with orientation angel of 10 .deg. , 15 . deg. are generally useful.

  • PDF

Quality Characteristics of Omija (Schizandra chinesis Baillon) Extracts Under Various Conditions for Beverage Production (음료 제조를 위한 오미자 추출물의 추출 조건에 따른 품질 특성)

  • Min, Sung Hee
    • Journal of the Korean Society of Food Culture
    • /
    • v.28 no.3
    • /
    • pp.320-327
    • /
    • 2013
  • The quality characteristics of Omija (Schizandra chinesis Baillon) extracts under various extraction temperatures and times were examined. The pH level of the extracts ranged from 3.35-3.47. The sugar and solid content of the samples significantly increased with increasing extraction temperatures and times (p<0.01). In contrast, the lightness of the extracts decreased with increasing extraction temperatures and times (p<0.001). In a palatability test, extracts boiled at $80^{\circ}C$ for 30 minutes scored high in terms of color, flavor, turbidity, sourness, and overall acceptability. Hydroxy radical scavenging activity and polyphenol content of the extracts significantly increased with increasing extraction temperatures and times (p<0.01). Furthermore, direct correlations between hydroxy radical scavenging activity and polyphenol content (or flavonoid content) were established through simple regression (r>0.9) for different extraction temperatures and times. From these results, extracts boiled at $80^{\circ}C$ for 120 minutes is the best to product omija beverage considering functionality and sensory evaluation as well.

A study on impact collapse characteristics of CFRP thin-walled laminates under high temperatures and hygrothermals (고온 고습하에서 CFRP 적층 원통부재의 충격 압궤특성)

  • 김정호;곽훈이;양인영
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.30-38
    • /
    • 1998
  • In this study, in order to measure energy-absorbing characteristics in impact test of CFRP thin-walled laminates and interpret the cause of decreasing age when collapse test is carried out under the environments of high temperatures and hygrothermals, the moisture absorbing behavior according to the variety of orientation angle is observed and impact collapse characteristics of no moisture absorbing status is compared with that under the environments of high temperatures and hygrothermals. Especially, we try to obtain quantitative design data to develop CFRP thin-walled laminates with energy characteristics of optimum impact absorbing. The value of the maximum loading, mean loading, rate of energy absorption energy per unit volume and mass in CFRP thin-walled laminates on the high temperatures and hygrothermals is measured much lower than under no moisture absorbing. The maximum collapse loading in dynamic impact test is taken measurements lower than in static collapse test CFRP circular laminates in high temperatures and hygrothermals. But the absorbed energy per unit mass and volume is almost same each other and the biggest amount of energy is shown in CFRP circular laminates with orientation angle of $15^{\circ}$. Therefore, in the case of using CFRP circular laminates with axisymmetric mode, CFRP thin-walled structural members with orientation angle of $10^{\circ}$, $15^{\circ}$ has generally best condition.

  • PDF

Flexural-torsional buckling tests of cold-formed steel compression members at elevated temperatures

  • Heva, Yasintha Bandula;Mahendran, Mahen
    • Steel and Composite Structures
    • /
    • v.14 no.3
    • /
    • pp.205-227
    • /
    • 2013
  • Current design standards do not provide adequate guidelines for the fire design of cold-formed steel compression members subject to flexural-torsional buckling. Eurocode 3 Part 1.2 (2005) recommends the same fire design guidelines for both hot-rolled and cold-formed steel compression members subject to flexural-torsional buckling although considerable behavioural differences exist between cold-formed and hot-rolled steel members. Past research has recommended the use of ambient temperature cold-formed steel design rules for the fire design of cold-formed steel compression members provided appropriately reduced mechanical properties are used at elevated temperatures. To assess the accuracy of flexural-torsional buckling design rules in both ambient temperature cold-formed steel design and fire design standards, an experimental study of slender cold-formed steel compression members was undertaken at both ambient and elevated temperatures. This paper presents the details of this experimental study, its results, and their comparison with the predictions from the current design rules. It was found that the current ambient temperature design rules are conservative while the fire design rules are overly conservative. Suitable recommendations have been made in relation to the currently available design rules for flexural-torsional buckling including methods of improvement. Most importantly, this paper has addressed the lack of experimental results for slender cold-formed steel columns at elevated temperatures.

Predicting the bond between concrete and reinforcing steel at elevated temperatures

  • Aslani, Farhad;Samali, Bijan
    • Structural Engineering and Mechanics
    • /
    • v.48 no.5
    • /
    • pp.643-660
    • /
    • 2013
  • Reinforced concrete structures are vulnerable to high temperature conditions such as those during a fire. At elevated temperatures, the mechanical properties of concrete and reinforcing steel as well as the bond between steel rebar and concrete may significantly deteriorate. The changes in the bonding behavior may influence the flexibility or the moment capacity of the reinforced concrete structures. The bond strength degradation is required for structural design of fire safety and structural repair after fire. However, the investigation of bonding between rebar and concrete at elevated temperatures is quite difficult in practice. In this study, bond constitutive relationships are developed for normal and high-strength concrete (NSC and HSC) subjected to fire, with the intention of providing efficient modeling and to specify the fire-performance criteria for concrete structures exposed to fire. They are developed for the following purposes at high temperatures: normal and high compressive strength with different type of aggregates, bond strength with different types of embedment length and cooling regimes, bond strength versus to compressive strength with different types of embedment length, and bond stress-slip curve. The proposed relationships at elevated temperature are compared with experimental results.