• Title/Summary/Keyword: temperature zone

Search Result 1,876, Processing Time 0.033 seconds

A Vegetation Characteristics of a Cut-Slope Affected by Seeding Periods of the Winter Season (동절기 파종시기에 따른 훼손비탈면의 녹화특성)

  • Kim, Jae-Hwan;Shim, Sang-Ryul
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.2
    • /
    • pp.29-39
    • /
    • 2009
  • Research was initiated to investigate a vegetation characteristics of the winter season by seeding periods. 3 seeding periods (Mid-December seeding plot, Late January seeding plot and Early March seeding plot) and 3 zones (the top zone, the middle zone and the bottom zone) in each plot were treated with 3 replications on the experimented slope. Data such as vegetation coverage (%), soil hardness (MPa), temperature ($^{\circ}C$) and moisture (%) content were analyzed. The vegetation coverage was high in Early March seeding plot, medium in Mid-December, and low in Late January seeding plot. Early March seeding plot was effective in moisture content, soil hardness, and temperature for the growth of vegetation when compared to Late January seeding plot and Mid-December seeding plot. From the standpoint of coverage ratio of plant species, the coverage of Dianthus sinensis and Albizzia julibrissin were high in the Late January seeding plot whereas the coverage of Lotus corniculatus and Cool-season turfgrass were high in Early March seeding plot. These results indicated that the high vegetation coverage of Dianthus sinensis and Albizzia julibrissin in Early March seeding plot was caused by scarification during winter season. There was no difference observed in plant height regardless of seeding periods except in early surveying time of May and June after seeding. As far as each zone of the plot was concerned, the vegetation coverage was high. in the bottom zone, medium in the middle zone and low in the top zone. The bottom area of the experimented slope was high in moisture content when compared to the middle zone and the top zone.

Study on the Temperature Variation of Greenhouse Soil Warming using the Solar Energy(1) - Temperature Variation of Soil Depth by Soil Warming - (태양열을 이용한 시설재배 지중변온가온의 토양 온도특성 연구(1) - 지중변온가온에 따른 깊이별 온도특성 -)

  • Kim, J.H.;Kim, T.W.;Nah, K.D.;Kim, T.S.;Sung, I.J.;Chung, S.H.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.3
    • /
    • pp.190-196
    • /
    • 2009
  • The temperature of root zone is known as an important factor for the growth of crops and reduction of energy in greenhouse. The purpose of this study was to design the solar energy supply system to keep the optimum condition of root zone by soil warming. As a result of this study, soil warming compared with no warming changed on a large scale temperature rise effect by depth of soil. The greenhouse's inner temperature have an effect on the temperature of surface up to 15 cm, rised to about 1 hour after warming. In case of the temperature fluctuation, soil temperature was about $12^{\circ}C$ up to 15${\sim}$25 cm and it was $13.4^{\circ}C$ at greater depths. This results showed that the position of root zone was very different after 3 weeks of growth.

가변 풍량 유닛에 의한 실내 공간의 온도제어를 위한 공간의 분할 모델과 상태궤환 제어기의 개발에 관한 연구

  • 박세화;신승철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.947-959
    • /
    • 2001
  • We propose a control scheme to control the indoor zone temperature via variable air volume (VAV) unit. To control the room temperature, state space model of the conditioned zone which is partitioned into nine artificial sectional regions is derived. The nonlinearity of the damper motion and actuator are considered for the practical use in the state space system description. The temperature control of the room temperature is performed by manipulating the degree of openness of the damper in relation to the local room temperature and the supplied air flow rate. In general, since a local temperature in the conditioned zone is measured, it is required to estimate the temperature values in each regions for the precise temperature control. We thus design a state observer to estimate the regional temperature, and use these values in the controller. The overall control system consists of the state observer based state feedback with the integral control. We compared the control results of the proposed scheme with those of cascade proportional and integral (PI) control, and showed that the scheme achieved precise control of the conditioned system.

  • PDF

Effect of Root Zone Temperature during the Night on the Growth and yield of Perlite Cultured Tomato in Winter (겨울철 토마토 2단말식 펄라이트경에서 야간 근권 온도가 토마토의 생육 및 수량에 미치는 영향)

  • 이한철;강경희;권기범;최영하
    • Journal of Bio-Environment Control
    • /
    • v.10 no.1
    • /
    • pp.30-35
    • /
    • 2001
  • This experiment was undertaken to investigate the effect of root zone temperature during the night on absorption of mineral nutrients, growth, and fruit yield of the truss-limited hydroponic tomatoes in winter. The root zone temperature was either controlled to 10, 15, 20, $25^{\circ}C$, or left uncontrolled at ambient temperatures. Temperature of the covered beds rose as root zone temperature was raised, but it in all treatments was less than 3$^{\circ}C$ higher than that in the control. Raising root zone temperature, except $25^{\circ}C$, showed positive effect on plant height, leaf length, stem diameter, and plant fresh and dry weight, but not on T/R ratio which was the greatest in the control. Root activity in all treatments except $25^{\circ}C$ increased as compared to the control. Mean fruit weight, fruit count per plant, and fruit yield were the greatest in 2$0^{\circ}C$ treatment. Root zone temperature did not significantly affect the contents of total nitrate and magnesium in leaves, stems and roots. Concentrations of phosphate and calcium increased in leaves and stems, but decreased in roots as root zone temperature increased. Overall, 2$0^{\circ}C$ treatment gave the greatest growth and energy efficiency.

  • PDF

Effect of Root Zone Temperature on the Induction of Inflorescence of Phalaenopsis in Summer (하절기 근권 온도가 팔레놉시스의 화경 발생에 미치는 영향)

  • Lee, Dong-Soo;Lee, Young-Ran;Yae, Byeong-Woo
    • Horticultural Science & Technology
    • /
    • v.29 no.1
    • /
    • pp.10-15
    • /
    • 2011
  • The influence of root zone temperature to the induction of inflorescence and growth of Phalaenopsis was investigated. Root zone temperatures were 15, 20, 25, and $30^{\circ}C$, while the air temperature was kept over $28^{\circ}C$ during three months. $CO_2$ uptake, fresh weight, dry weight and branched root number of Phalaenopsis were highest at $25^{\circ}C$ and lowest at $15^{\circ}C$. But, the anthocyanin content was highest at $15^{\circ}C$ and lowest at $25^{\circ}C$. Inflorescence was not induced by root zone cooling temperature below $25^{\circ}C$ for three months. The concentrations of K, Ca and Mg in leaves were changed according to the root zone temperature, but those of N and P were not changed. K content was high at $20^{\circ}C$, whereas Ca and Mg contents were high at $25^{\circ}C$ root zone temperature. This study indicates that Phalaenopsis perceives temperature by shoot and the optimum root-zone temperature for the vegetative growth is $25^{\circ}C$.

Establishing the Comfort Zone of Thermal Environment in Winter (겨울철 실내온열환경의 쾌적범위설정에 관한 실험연구)

  • 윤정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.2
    • /
    • pp.81-86
    • /
    • 1992
  • The purpose of this study was to investigate the psychophysical correponding to temperature and to establish the comfort zone of thermal environment for Korean in winter. An experimental investigation was carried out in climate chamber maintaining the air temperature at 20, 22, 24, 26℃ and subjects were 128 college-age Korean(64 males and 64 females) in good health. Data were analyzed by SPSS PC+ packages. 'Neutral' on the thermal sensation ratings was most frequently indicated at 24℃ by subjects was 23.1℃ (male 24.0℃, female 22.7℃), therefore the comfort zone of thermal environment in winter was considered as 23∼24℃.

  • PDF

Characterization of vertical temperature distribution in Hyporheic zone (지하수-지표수 혼합구간의 수직 온도 분포 특성 분석)

  • Kim, Hee-Jung;Lee, Jin-Yong;Lee, Seong-Sun;Hyun, Yun-Jung;Lee, Kang-Kun
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.265-273
    • /
    • 2011
  • Hyporheic zone, where groundwater-stream water mixing occurs, sensitively responds to heat of groundwater and stream water temperature. Variation of stream water temperature has short time period and time dependent, because stream water temperature is influenced by daily fluctuation and seasonal air temperature. On the other hand, groundwater temperature is insignificant. In this study, we conducted 1-dimensional heat transfer analysis. The results show that there are differences of temperature distribution between gaining stream and losing stream with flux in hyporheic zone. Especially, variations of hyporheic water temperature show a significant difference in adjacent streambed, Also, the results shows that distribution of temperature was more affected by groundwater direction than intensity of flux.

Stabilization Characteristics of the Diffusion Flame Formed in the Wake of Bluff Body with Fuel Injection (연료분출을 수반하는 보염기 후류에 형성되는 확산화염의 보염특성)

  • 안진근
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.223-232
    • /
    • 2001
  • To study the stabilization characteristics of diffusion flame formed in the wake of a cylindrical bluff body with fuel injection, the flame stability limits, length and temperature of recirculation zone of flame, turbulence intensity distribution near the recirculation zone of flame were measured and analyzed. The length of recirculation zone is independent on main fuel injection quantity, but it is dependent on fuel injection angles, air stream velocity, and auxiliary fuel injection into recirculation zone. For diffusion flame, in general, the flame stabilization is deteriorated with increase of he length of recirculation zone, but if the turbulence generator is installed, the flame stabilization is improved with increase of the length of recirculation zone. The temperature of recirculation zone is dependent on fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators, and it dependent on fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators, and it has a maximum value at the condition of each theoretical mixture. In general, the more temperature of recirculation zone is low, the more flame is stable. But when the turbulence generator is installed, the more temperature of recirculation zone is low, the more flame is unstable. The turbulence intensity in the wake of bluff body is increased with increase of diameter or blockage ratio of grid. The more turbulence intensity is increased by installation of turbulence generator, the more flame is unstable. Finally, It is clear that the stabilization characteristics of diffuser flame can be controlled by some parameters such as fuel injection angles, auxiliary fuel injection into recirculation zone, turbulence generators.

  • PDF

A Study on the Evaluatioin Methods for the Rear Safety Zone of Portable Guided Missile (휴대용 유도탄의 후방 안전영역 평가방법에 관한 연구)

  • Song, Kee-Hyeok;Kang, Woo-Ram;Park, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.2
    • /
    • pp.63-69
    • /
    • 2015
  • Recoilless weapons, which lead strong back blast and impulse noise more than 160 dB, have been used in compliance with the regulation of the safety zone for the safe operations. However, the safety zone regulations for the newly developed weapons should be prepared since the existing guidelines do not provide any information concerning the reason for the safety zone. In this study, the outdoor launch tests were performed to collect the data such as noise, pressure and temperature of the back blast. An assessment method using data obtained from launch tests has been proposed to determine the safety zone. The safety zone has been determined with consideration for the following criteria: Impulse noise, temperature and pressure of the back blast and blast angle. As a results, new safety zones for them have been established for the recoilless weapon developed by ADD (Agency for Defense Development). We expect that this research can be used as a guideline for establishing a new safety zone regulation of similar weapon to be developed.

The Performance Evaluation of a Gas Turbine Combustor (가스터빈 연소기의 성능평가)

  • Ahn, Kook-Young;Kim, Han-Seok;Ahn, Jin-Hyuk;Pae, Hyoung-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1294-1299
    • /
    • 2000
  • The combustion characteristics have been investigated to develop the 50 kW-class gas turbine combustor. The combustor design program was developed and applied to design this combustor. The combustion air which has the temperature of 45, 200, $300^{\circ}C$ were supplied to combustor for elucidating the effect of inlet air temperature on CO, NOx emissions and flame temperature. The exit temperature and NO were increased and CO was decreased with increasing inlet air temperature. Also, the effect of equivalence ratio was considered to verify the combustor performance. The emissions of CO and NO with inlet air temperature can be analyzed qualitatively by measuring the temperature inside the combustor. The combustion performance with fuel schedule was evaluated to get the informations of the starting and part loading process of gas turbine. The combustion was stable above the equivalence ratio of 0.18. The pattern factor which is the important parameter of combustor performance was satisfied with the design criterion. Consequently the combustor was proved to meet the performance goal required for the target gas turbine system.