• Title/Summary/Keyword: temperature variation

Search Result 5,676, Processing Time 0.035 seconds

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on the Variation of Secondary Fluid Conditions (2차 유체 조건 변화에 대한 CO2용 수냉식 열펌프의 성능 특성에 관한 연구)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.543-551
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of inlet temperature and mass flow rate of secondary fluid was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which ate made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4 m length. The experimental results were summarized as the followings : As inlet temperature of secondary fluid in the gas cooler increases from $10^{\circ}C$ to $40^{\circ}C$, the compressor work, heating capacity and heating COP were varied to 37.8%, -13%, -35.9%, respectively. The heating capacity, compressor work, heating COP were turned into 23.3%, 6.42%, 13.1%, respectively when ass flow rate of secondary fluid in the evaporator increases from 70 g/s to 150 g/s. The above tendency is similar with performance variation with respect to temperature variation of secondary fluid in the conventional vapor compression cycle.

Design of Fixed Phase Control Circuit of Group Delay Line using Adaptive Vector Control (자동적응 벡터 제어를 이용한 군속도 지연선로의 고정 위상 제어기 설계)

  • 정용채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.8
    • /
    • pp.1376-1385
    • /
    • 2000
  • The phase characteristic of delay line in feedfarward linearizer has been changed due to variation of operating temperature. In this paper, design method of fixed phase control circuit of group delay line using adaptive vector control is derived. To maintain transfer characteristics of nominal operating temperature, the error correlated signals, which are changed adaptively due to changing of temperature, are added to main signals. The proposed method maintains transfer characteristics under 0.06dB of insertion loss and 0.36$^{\circ}$ of phase variation in case of 1-tone(880 MHz) and under 0.07 dB of insertion loss and 0.35$^{\circ}$ of phase variation in case of 2-tones(877 MHz, 882 MHz) for 10dB input power dynamic range and +/-10$^{\circ}$ phase variation respectively.

  • PDF

Sea Level Variations at Kerguelen Island in the South Indian Ocean by the Satellite Data(ARGOS) and Meteorological Data(METEO)

  • Yoon, Hong-Joo
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.2
    • /
    • pp.117-133
    • /
    • 2000
  • We studied the sea level variations at Kerguelen island in the South Indian Ocean with ARGOS data and meteorological data during about 1 year(May 1993~April 1994) through using filter, spectral analysis, coherency and phase, and found characteristics for the two oceanic signal levels(detided oceanic signal level, h$_{detided}$ and seasonal oceanic level, h$_{corr.ib}$). The forms of atmospheric pressure variations are good agreed to between ARGOS data and meteorological data in the observed periods. This Kerguelen area shows the inflow of an air temperature(gain of a radiant heat) into the sea water and the stagnation of high atmospheric pressure bands in summer, and the outflow of a sea water temperature(loss of sensible and latent heat) toward the atmosphere and the stagnation of low atmospheric pressure bands in winter. The seasonal difference of sea level between summer and winter is about 1.6cm. Both the detided oceanic signal level(h$_{detided}$) variation and the inverted barometer level(h$_{ib}$) variation have a strong correlation for T>1day period bands. The characteristics of h$_{detided}$ variation are not decided by the influence of any meteorological distributions (atmospheric pressure), but the influence of other factors(bottom water temperature) for T>2days periods bands. h$_{corr.ib}$ plays a very important role of sea level variation in the observed periods (especially T>about 180days period bands).

Preliminary Study on Magnetic Resonance Temperature Measurement using Brain-Metabolite Phantom (뇌 대사물질 팬텀을 이용한 뇌의 자기공명 온도측정법에 관한 기초 연구)

  • Han, Yong-Hee;Jang, Moo-Young;Mun, Chi-Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.412-416
    • /
    • 2010
  • In this study, we measured the chemical shift change of metabolite peaks in the brain-metabolite phantom according to the temperature variation using nuclear magnetic resonance(NMR). The temperature range in NMR system was controled from 25 to 80 (5 step) by internal temperature controller. Temperature coefficients of each metabolite peaks were also calculated from the measured chemical shift depending on the temperature. The chemical shift changes depending on temperature were validated by linear regression method for each metabolite peaks. The temperature coefficients of $_{tot}Cr$, Cho, Cr, NAA, and Lac were 0.0086, 0.0088, 0.0091, 0.0089, and 0.0088ppm/$^{\circ}C$, respectively. This study shows that chemical shift change of brain metabolite and temperature variation have linear relationship each other. This also makes authors believe that brain temperature measurement is possible using MR spectroscopic imaging technique.

The Effects of Microstructures and Some Additives (CoO and $Al_2O_3$) on the Magnetic Properties of Mn-Zn Ferrite (미세조직 및 첨가성분 (CoO와 $Al_2O_3$)이 Mn-Zn Ferrite의 자기적 성질에 미치는 영향)

  • 변수일;장승현
    • Journal of the Korean Ceramic Society
    • /
    • v.16 no.3
    • /
    • pp.142-154
    • /
    • 1979
  • The effects of microstructures and some additives $(CoO and Al_2O_3$) on the magnetic properties such as initial permeability, $\mu$-T curve, coercive force, and magnetic induction of MnZn ferrites have been studied. The powder was prepared by Hot Petroleum Drying Method. The basic composition of MnZn ferrites was 25.5mole % MnO, 22.0 mole% ZnO, 52.5 mole% $Fe_2O_3$. CoO in a concentration range from 0.05 to 0.5 mole% and $Al_2O_3$ from 2.5 to 7.5 mole% were added. Sintered density increased up to 97.5% of theoretical density. Permeability increased as average grain size increased, and that coercive force decreased as average grian size increased. Magnetic induction increased as sintered density increased. The variation of initial permeability with temperature in a temperature range from 0$^{\circ}$ to $60^{\circ}C$ was lowered (a flatter $\mu-T$ curve) as sintering temperature decreased. The compensation temperature To ofmagnetocrystalline anisotropy constant K1 and initial permeability varied with the species and amount of additives. When 0.05 mole% CoO was added to the basic composition, initial permeability at $15^{\circ}C$ increased from 5200 to 5900. The variation ofinitial permeability with temperature in a temperature range from 0^{\circ}to $60^{\circ}C$ was smaller (a flatter $\mu$-T curve) than that of the basic composition of Mn Zn ferrites. When 2.5 mole% $Al_2O_3$ was added, initial permeability at $15^{\circ}C$ decreased from 5200 to 3000. But the variation of initial permeability with temperature in a temperature range from 0$^{\circ}$to $60^{\circ}C$ was smaller (a flat ter $\mu-T$ curve) than when 0.05 mole% CoO was added. Experimental results showed that the conditions necessary for the occurrence of a very high permeability and a flat $\mu$-T curve were controversial even in a temperature range from $0^{\circ}$to $60^{\circ}C$.

  • PDF

Generation characteristics of transparent BIPV module according to temperature change (건물일체형 투명 모듈의 온도 변화에 따른 발전 특성)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;Yu, Gwon-Jong;Jang, Dae-Ho;Lee, Moon-Hee;Kim, Jun-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.210-211
    • /
    • 2007
  • Amid booming PV(photovoltaic) industry, BIPV(Building Integrated PV) is one of the best fascinating PV application technologies. To apply PV in building, variable factors should be reflected such as installation position, shading, temperature effect and so on. Especially a temperature should be considered, for it affects both electrical efficiency of PV module and heating and cooling load in building. Transparent PV modules were designed as finished material for spandrels are presented in this paper. The temperature variation of the modules with and without air gap and insulation were compared and analyzed. The results showed that the module with air gap and insulation has a much larger temperature variation than another transparent module. The temperature of the module reached by 55degree C under vertical irradiance of lower 500$W/m^2$. And the temperature difference between these modules was about 15degree C. To analyze the output performance of module according to temperature variation, separate module was manufactured and measured by sun-simulator. The results showed that 1 degree temperature rise reduced about 0.45% of output power.

  • PDF

The Outlet Temperature Prediction of In-Situ Thermal Response Test using CFD Analysis (CFD 해석을 이용한 현장 열응답 시험의 출구온도 예측)

  • Sim, Yong-Sub;Lee, Hee-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.28-35
    • /
    • 2016
  • The in-situ thermal response test for the design of a ground heat exchanger of geothermal heat pumps have difficulty in predicting the outlet temperature according to the variation of conditions due to the expense and time. This paper suggests a 3-D CFD analysis method to predict the heat transfer performance of vertical type ground heat exchanger, which is mostly used in national, and the outlet temperature and the slope of two in-situ thermal response tests were compared to test the proposed CFD reliability. The results of CFD analysis showed that the outlet temperature was predicted to within $0.5^{\circ}C$ of the actual value and the slope was predicted to within 1.6%. The reliability of the CFD analysis method was confirmed using this process, and the outlet temperature prediction of the two in-situ thermal response tests was obtained by changing ${\pm}20%$ of the flow rate and the effective thermal conductivity conditions, respectively. The results of CFD analysis showed that the outlet temperature of Case 1 was 28.0 (-20%) and $29.6^{\circ}C$ (+20%) for the flow rate variation and $29.6^{\circ}C$ (-20%) and $28.0^{\circ}C$ (+20%) for the effective thermal conductivity variation, and the outlet temperature of Case 2 was 28.4 (-20%) and $29.8^{\circ}C$ (+20%) for the flow rate variation and $29.7^{\circ}C$(-20%) and $28.4^{\circ}C$(+20%) for the effective thermal conductivity variation.

The temperature measurement at external auditory meatus using Infrared sensor in cattle (적외선 센서를 이용한 소 귀에서의 체온 측정)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.401-404
    • /
    • 2008
  • In livestock, diagnosis of disease is found on body temperature variation like a human. In case of cattle, body temperature variation can estimate disease that milk fever, toxication, diarrhea, dyspepsia, chronic enteritis, influenza, pneumonia, anthrax. So we are suggested the temperature measurement system for livestock. This system will be useful to a stock farmer and alternative that a worker.

  • PDF

Characteristics of Methane Turbulent Lifted Flames in Coflow Jets with Initial Temperature Variation (동축류 제트에서 초기 온도 변화에 따른 메탄 난류 부상화염 특성)

  • Choi, Byung-Chul;Chung, Suk-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2372-2377
    • /
    • 2007
  • Characteristics of turbulent lifted flames in coflow jets with the varying initial temperature have recently been investigated about only propane case diluted by nitrogen. The investigation has firstly improved a premixed flame model and a large scale mixing model among competing theories on the stabilization mechanism of turbulent flame to be suitable for a high temperature condition. In this research, about methane with good availability to apply for a practical combustor as clean fuel, its characteristics of turbulent nonpremixed flame have been studied experimentally. The results have shown an effectiveness of the premixed flame model and the large scale mixing model considered initial temperature variation. Additionally, considering the axial distance where the mean fuel concentration falls below the stoichiometric level along the center line of the jet according to diluting nitrogen, the premixed flame model have more accurately been improved.

  • PDF

Numerical analysis for behavior of outer concrete tank in emergency LNG spillage

  • Lee, Jeong Su;Park, Chan Kyu;Lee, Yun;Kim, Ji-Hoon;Kwon, Seung Hee
    • Computers and Concrete
    • /
    • v.14 no.4
    • /
    • pp.369-385
    • /
    • 2014
  • In the existing method for analyzing the liquid tightness of the outer concrete tank in an emergency LNG spillage, the temperature variation over time inside the tank, and the concrete properties dependent on temperature and internal moisture content, have not been taken into account. In this study, the analyses for a typical LNG concrete tank subjected to thermal load due to spillage were performed with three different cases: the existing method was adopted in the first case, the transient temperature variation was considered in the second, and the temperature-moisture content dependent concrete properties were taken into account as well as the transient states of temperature in the third. The analysis results for deformation, compressive zone size, cracking, and stress of reinforcements were compared, and a discussion on the difference between the results obtained from the different analysis cases was made.