• 제목/요약/키워드: temperature standards

검색결과 885건 처리시간 0.025초

오피스 건물의 실내 환경 실태 조사 (The Field Survey of Indoor Environment of the Office Building)

  • 양영권;강인성;정민희;문진우;박진철
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.71-76
    • /
    • 2016
  • Purpose: This study aimed at improving the indoor environment of the office building by measuring the indoor environment and conducting a survey. Method: The measurement was conducted from January 13 to March 16 in 2012, targeting 44 sites in same office building located in Seoul, South Korea. The lists of measurement such as dry-blub temperature, relative humidity, formaldehyde (HCHO), asbestos, carbon monoxide (CO), carbon dioxide (CO2), volatile organic compounds (VOCs) and particle pollution (PM10) were measured. In addition, illuminance which belongs to light environment and noise in sound[acoustical] environment were measured respectively. Result: The buildings showed overall pleasant conditions. In terms of the thermal, air, sound, and visual environment, each measurements were satisfied with the requirements in standard, within pleasant ranges, except several sites. However, the survey results were revealed that the office workers were mostly dissatisfied with their indoor environment. Given that the measured values were mostly within standards, the results of survey might have resulted from a compensation mentality biased toward the subjects in psychological terms.

Effects of electron beam irradiation on the superconducting properties of YBCO thin films

  • Lee, Y.J.;Choi, J.H.;Jun, B.H.;Joo, J.;Kim, C.S.;Kim, C.J.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권4호
    • /
    • pp.15-20
    • /
    • 2016
  • The effects of electron beam (EB) irradiation on the superconducting critical temperature ($T_c$) and critical current density ($J_c$) of YBCO films were studied. The YBCO thin films were irradiated using a KAERI EB accelerator with an energy of 0.2 MeV and a dose of $10^{15}-10^{16}e/cm^2$. A small $T_c$ decrease and a broad superconducting transition were observed as the EB dose increased. The value of $J_cs$ (at 20 K, 50 K and 70 K) increased at doses of $7.5{\times}10^{15}$ and $2.2{\times}10^{16}e/cm^2$. However, $J_cs$ decreased as the dose increased further. The X-ray diffraction (XRD) analysis showed that the c axis of YBCO was elongated and the full width at half maximum (FWHM) increased as the dose increased, which is strong evidence of the atomic displacement by EB irradiation. The transmission electron microscopy (TEM) showed that the amorphous layer formed in the vicinity of the surfaces of the irradiated films. The amorphous phase was often present as an isolated form in the interior of the films. In addition to the formation of the amorphous phase, many striations running along the a-b direction of YBCO were observed. The high magnification lattice image showed that the striations were stacking faults. The enhancement of $J_c$ by EB irradiation is likely to be due to the lattice distortion and the formation of defects such as vacancies and stacking faults. The decrease in $J_c$ at a high EB dose is attributed to the extension of the amorphous region of a non-superconducting phase.

GPS-X 기반 모델링에 의한 강변사업소 처리효율 분석 및 반류수 처리 공정 설계 (GPS-X Based Modeling on the Process of Gang-byeon Sewage Treatment Plant and Design of Recycle Water Treatment Process)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제25권11호
    • /
    • pp.1493-1498
    • /
    • 2016
  • The efficiencies of Gang-Byeon sewage treatment facilities, which are based on GPS-X modelling, were analysed and used to design recycle water treatment processes. The effluent of an aeration tank contained total kjeldahl nitrogen (TKN) of 1.8 mg/L with both C-1 and C-2 conditions, confirming that most ammonia nitrogen ($NH_3{^+}-N$) was converted to nitrate nitrogen ($NO_3{^-}-N$). The concentrations of $NH_3{^+}-N$ and $NO_3{^-}-N$ were found to be 222.5 and 227.2 mg/L, respectively, with C-1 conditions and 212.2 and 80.4 mg/L with C-2 conditions. Although C-2 conditions with higher organic matter yielded a slightly higher nitrogen removal efficiency, sufficient denitrification was not observed to meet the discharge standards. For the total nitrogen (T-N) removal efficiency, the final effluent concentrations of T-N were 293.8 mg/L with biochemical oxygen demand (BOD) of 2,500 mg/L, being about 1.5 times lower than that (445.3 mg/L) with BOD of 2,000 mg/L. Therefore, an external carbon source to increase the C/N ratio was required to get sufficient denitrification. During the winter period with temperature less than $10^{\circ}C$, the denitrification efficiency was dropped rapidly even with a high TKN concentration (1,500 mg/L). This indicates that unit reactors (anoxic/aerobic tanks) for winter need to be installed to increase the hydraulic retention time. Thus, to enhance nitrification and denitrification efficiencies, flexible operations with seasons are recommended for nitrification/anoxic/denitrification tanks.

Solidification/Stabilization of Dyeing Sludge Treated by Fenton Reagent Using Blast Furnace Slag and Fly Ash

  • Lee, Sookoo;Kim, Sebum
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.453-458
    • /
    • 2001
  • This study was performed to reuse the dyeing wastewater sludge treated by Fenton process through the solidification/stabilization technique. To solidify the dyeing sludge the industrial by-products such as blast furnace slag, fly ash and waste sand with cement were used. The laboratory scale and pilot scale test were conducted at room temperature to make construction brick which has high compressive strength and low leaching of heavy metals. The experimental results showed that blast furnace slag and fly ash could be used instead of cement and the products satisfied the regulation of Korean Standards. The blast furnace slag increased the compressive strength and the optimum ratio of slag/dyeing sludge on dry basis was found 0.4. The solidifying agent of SB series could increase rapidly the compressive strength and the optimum ratio of solidifying agent/sludge on dry basis was 0.26 at which the strength was two times compared with non-added condition. The portion of waste and industrial by-products in matrix was over 80%. From the pilot test the optimum pressure in molding was 100kg/$\textrm{cm}^2$ at which the compressive strength was over 100kg/$\textrm{cm}^2$. And the strength increased continuously to 160kg/$\textrm{cm}^2$ until 120 days curing time due to pozzolanic reaction. When SB-20 as a solidifying agent was used, the unconfined compressive strength of dyeing sludge could be obtained 110kg/$\textrm{cm}^2$ which satisfied the regulation of cement brick in Korea Standard(KS).

  • PDF

탐진강 수질측정 지점 간 동질성 검정을 위한 비모수적 자료 분석 (A Non-parametric Analysis of the Tam-Jin River : Data Homogeneity between Monitoring Stations)

  • 김미아;이수웅;이재관;이정섭
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.651-658
    • /
    • 2005
  • The Non-parametric Analysis is powerful in data test especially for the non- normality water quality data. The data at three monitoring stations of the Tam-Jin River were evaluated for their normality using Skewness, Q-Q plot and Shapiro-Willks tests. Various constituent of water quality data including temperature, pH, DO, SS, BOD, COD, TN and TP in the period of January 1994 to December 2004 were used as dataset. Shapiro-Willks normality test was carried out for a test 5% significance level. Most water quality data except DO at monitoring stations 1 and 2 showed that data does not normally distributed. It is indicating that non-parametric method must be used for a water quality data. Therefore, a homogeneity was conducted by Mann-Whitney U test (p<0.05). Two stations were paired in three pairs of such stations. Differences between stations 1, 2 and stations 1, 3 for pH, BOD, COD, TN and TP were meaningful, but Tam-Jin 2 and 3 stations did not meaningful. In addition, a narrow gap of the water quality ranges is not a difference. Categories in which all three pairs of stations (1 and 2, 2 and 3, 1 and 3) in the Tam-Jin River showed difference in water quality were analyzed on TN and TP. The results of in this research suggest a right analysis in the homogeneity test of water quality data and a reasonable management of pollutant sources.

대도시 젊은이들의 라이프스타일 유형별 외식서비스 인카운터 중요 속성 연구 (The Important Attributes of Foodservice Encounters According to Life-style Types as Offered by Young Metropolitan Customers)

  • 윤혜려;조미숙
    • 한국식품조리과학회지
    • /
    • 제23권3호통권99호
    • /
    • pp.327-336
    • /
    • 2007
  • Life-style factors often include social relationships as well as consumption, entertainment and dress patterns. They also typically reflect an individual's attitudes, values and worldview. Life-style types have become and an important factor for segmenting customer markets ever since significant relationships between life-style and customers' behavior was proven. This study examined the relationships between the life-styles of young customers' and the important attributes of foodservice encounters. Factors analysis with VARIMAX and K-means cluster analysis were conducted to group the subjects by life-style. According to the factors analysis, four underlying dimensions were identified and labeled: (1) 'actively fashioned', (2) 'luxury picky', (3) 'healthy toward', and (4) 'utilitarian leisure'. Based on the factor scores derived from the factors analysis, the K-means cluster analysis classified three groups as statistically significant using ANOVA(p<0.05). The overall mean score for the 3rd cluster 'trendy-active picky' was higher than the other two clusters, and represented very picky attitudes about foodservice attributes. The 3rd cluster also seemed to apply higher standards to all of the foodservice attributes. By order of importance, the most important attributes of the 2nd cluster 'pursue-utilitarian leisure' were food serving time, automation systems, server's hygienes, employee kindness, time in line, and menu variety. In spite of low concerns for the life-style attributes, the first cluster 'passively indifferent' recognized menu variety, food sanitation, food serving time, server's hygiene, menu price, air circulation, and room temperature as important. These results suggest that young diners in Korea could be classified by their diverse life-styles that are represented as trendy, utilitarian, and indifferent and will hopefully contribute to the foodservice industry's ability to segment customer characteristics by different life-styles in Korea.

미용사들의 작업환경과 호흡기 자각증상과의 관련요인 (The Related Factor on a Work Environment of Hairdressers and a Subjective Symptom of Respiratory Organ)

  • 이계숙;이명희
    • 한국생활과학회지
    • /
    • 제17권6호
    • /
    • pp.1215-1224
    • /
    • 2008
  • This research has measured the indoor environment of thirty hair salons, which are located on Gunsan-Si, Jeonlabbuk-Do, from April 1st to April 30th 2005, to examine the related factors on a work environment of hairdressers and a revelation of respiratory symptom, and has polled 260 hairdressers and 350 office workers. After measuring the physical environment of hair salons, the room temperature, the relative humidity and the illumination was in an agreeable range, and 60 percent of hair salons depended on the natural ventilation through the windows. The levels of acetone, toluene and xylene, which were measured at the hair salons, were all under the safety standards (p<0.05), but these are still harmful and volatile matters, so they can be bad for your health by the contact of skin and respiration. The harmful factors that affect a revelation of respiratory symptom were the group who has many exposures of permanent wave or bleaching/dyeing and not many experiences of hairdressing work, the group who smokes every day, and the group who never exercises at all (p<0.05). This result shows that there are possibilities of health problem for hairdressers from the constant and repeating hairdressing works with the exposure of chemicals such as the permanent, bleaching and dyeing. so that hairdressers recognize that they need appropriate ventilation facilities for their agreeable indoor-environments. And also, to prevent the direct exposure of chemicals as much as they can, they need to have an active management of an individual health care by wearing gloves, mask or something like that.

The audit method of cooling energy performance in office building using the Simple Linear Regression Analysis Model

  • Park, Jin-Young;Kim, Seo-Hoon;Jang, Cheol-Young;Kim, Jong-Hun;Lee, Seung-Bok
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.13-20
    • /
    • 2015
  • Purpose: In order to upgrade the energy performance of existing building, energy audit stage should be implemented first because it is useful method to find where the problems occur and know how much time and cost consumption for retrofit. In overseas researches, three levels of audit is proposed whereas there are no standards for audit in Korea. Besides, most studies use dynamic simulation in detail like audit level 3 even though the level 2 can save time and cost than level 3. Thus, this paper focused on audit level 2 and proposed the audit method with the simple linear regression analysis model. Method: Two parameters were considered for the simple regression analysis, which were the monthly electric use and the mean outdoor temperature data. The former is a dependent variable and the latter is a independent variable, and the building's energy performance profile was estimated from the regression analysis method. In this analysis, we found the abnormal point in cooling season and the more detailed analysis were conducted about the three heat source equipments. Result: Comparing with real and predicted models, the total consumption of predicted model was higher than real value as 23,608 kWh but it was the results that was reflected the compulsory control in 2013. Consequently, it was analyzed that the revised model could save the cooling energy as well as reduce peak electric use than before.

Quantitative Approaches for the Determination of Volatile Organic Compounds (VOC) and Its Performance Assessment in Terms of Solvent Types and the Related Matrix Effects

  • Ullah, Md. Ahsan;Kim, Ki-Hyun;Szulejko, Jan E.;Choi, Dal Woong
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권1호
    • /
    • pp.1-14
    • /
    • 2017
  • For the quantitative analysis of volatile organic compounds (VOC), the use of a proper solvent is crucial to reduce the chance of biased results or effect of interference either in direct analysis by a gas chromatograph (GC) or with thermal desorption analysis due to matrix effects, e.g., the existence of a broad solvent peak tailing that overlaps early eluters. In this work, the relative performance of different solvents has been evaluated using standards containing 19 VOCs in three different solvents (methanol, pentane, and hexane). Comparison of the response factor of the detected VOCs confirms their means for methanol and hexane higher than that of pentane by 84% and 27%, respectively. In light of the solvent vapor pressure at the initial GC column temperature ($35^{\circ}C$), the enhanced sensitivity in methanol suggests the potential role of solvent vapor expansion in the hot injector (split ON) which leads to solvent trapping on the column. In contrast, if the recurrent relationships between homologues were evaluated using an effective carbon number (ECN) additivity approach, the comparability assessed in terms of percent difference improved on the order of methanol (26.5%), hexane (6.73%), and pentane (5.24%). As such, the relative performance of GC can be affected considerably in the direct injection-based analysis of VOC due to the selection of solvent.

해수담수화플랜트에서 가스 하이드레이트 공정 도입을 통한 역삼투 공정의 에너지 절감 효과 (Effect of gas hydrate process on energy saving for reverse osmosis process in seawater desalination plant)

  • 김수한;임준혁
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.771-778
    • /
    • 2013
  • Gas hydrate (GH) process is a new desalination technology, where GH is a non- stoichiometric crystalline inclusion compounds formed by water and a number of gas molecules. Seawater GH is produced in a low temperature and a high pressure condition and they are separated from the concentrated seawater. The drawback of the GH process so far is that salt contents contained in its product does not meet the fresh water quality standard. This means that the GH process is not a standalone process for seawater desalination and it needs the help of other desalting process like reverse osmosis (RO). The objective of this study is to investigate the effect of GH process on energy saving for RO process in seawater desalination. The GH product water quality data, which were obtained from a literature, were used as input data for RO process simulation. The simulation results show that the energy saving effect by the GH process is in a range of 68 % to 81 %, which increases as the salt removal efficiency of the GH process increases. Boron (B) and total dissolved solids (TDS) concentrations of the final product of the hybrid process of GH and RO were also investigated through the RO process simulation to find relavant salt rejection efficiency of the GH process. In conclusion, the salt rejection efficiency of the GH process should exceed at least 78% in order to meet the product water quality standards and to increase the energy saving effect.