• 제목/요약/키워드: temperature limit

검색결과 1,358건 처리시간 0.028초

$La(Ba)Ga(Mg)O_3_\delta$계 Perovskite 산화물의 생성상 및 산소이온전도 (Phase Formation and Oxygen Ion Conduction of $La(Ba)Ga(Mg)O_3_\delta$ Perovskite Oxide System)

  • 이기태;김신;이홍림
    • 한국세라믹학회지
    • /
    • 제36권10호
    • /
    • pp.1056-1061
    • /
    • 1999
  • Phase formation and oxygen ion conduction of La(Ba)Ga(Mg)O3-$\delta$ system was studied, BaLaGa3O7 and BaLaGaO4 formed as a secondary phase above the solubility limit of Ba2+ in La3+ sites. The oxygen ionic conductivity of La(Ba)Ga(Mg)O3-$\delta$ was 0.1 S/cm 80$0^{\circ}C$ The activation energy of the oxygen ion conduction was dependent on temperature. This value was higher at low temperature than at high temperature.

  • PDF

Thermo-Mechanical Fatigue Analysis of Ribbon Wire/Ag Electrode Interfaces for PV Module

  • 박노창;홍원식;한창운;김동환
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.48.1-48.1
    • /
    • 2011
  • In this presentation, We monitored weather data, such as global irradiance, ambient temperature, temperature of PV module, relative humidity and windspeed for 2 years, for determining accelerated test condition. then, we determined the temperature limit of accelerated test through weather data and FEM analysis. Detailed procedures will be summarized in this work. After analysing outdoor stress such as thermal stress, we decided main failure modes and mechanisms of PV module, especially solder joint of ribbon wire. we carried out the measurement of material properties such as thermal expansion coefficient for planning of accelerated test. we designed accelerated test based on FEM analysis results. we carried out thermal cycling test with 1 cell mini module for 3 months. We monitored the change of electrical performance every 1 week such as Voc, Isc, Pmax, etc. and then, we analized the ribbon wire/electrode intefaces. Detailed results will be summarized in this work.

  • PDF

Numerical analysis of natural convection heat transfer from a fin in parallel enclosure

  • Bae, Myung-Whan;Mochimaru, Yoshihiro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권5호
    • /
    • pp.412-417
    • /
    • 2016
  • A fin of finite width with infinitely small thickness is assumed to be placed horizontally between two horizontal parallel plates of infinite extension in the exactly central position. The lower plate and the half of the upper plate are kept at a constant lower temperature, and the remaining upper plate is kept at a constant higher temperature. The fin is also kept at a constant temperature (variable). Steady-state two-dimensional laminar natural convection is analyzed as a problem of boundary value under a boundary-fitted conformal mapping system, using a spectral finite difference scheme, with a condition of doubly-connectedness. The steady-state solution is obtained as a limit of the transient solution.

입자강화 금속기 복합재료의 고온 피로강도 향상에 관한 연구 (A Study on the Improvement of Fatigue Strength in Particulate Reinforced Metal Matrix Composites at Elevated Temperatures)

  • 신형섭
    • 대한기계학회논문집A
    • /
    • 제24권5호
    • /
    • pp.1146-1154
    • /
    • 2000
  • Fatigue strength of NiAl and Ni$_3$Al particulate reinforced aluminum alloy composites fabricated by the diecasting method was examined at room and elevated temperatures. The results were compared wit h that of SiC particulate reinforced one. The particulate reinforced composites showed some improvement in the static and fatigue strength at elevated temperatures when compared with that of Al alloy. The composites reinforced by intermetallic compound particles showed good fatigue strengths at elevated temperatures especially $Ni_3AI_{p}/Al$ alloy composite showed good fatigue limit up to high temperature of 30$0^{\circ}C$. Adopting intermetallic compound particle as a reinforcement phase, it will be possible to develop MMC representing better fatigue property at elevated temperature.

전력용 고온초전도 금속테이프 제작을 위한 첨단 레이저공정 개발 (Development of advanced laser processing for the fabrication of HTS metallic tapes for power applications)

  • 이상렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.688-691
    • /
    • 1997
  • Good quality superconducting $YBa_2Cu_30_{7-{\delta}}$(YBCO) thin films were grown on Hastelloy (Ni-Cr-Mo alloys) with yttria-stabilized zirconia(YSZ) buffer layers by in situ pulsed laser deposition in a multi-target processing chamber. Generally, Hastelloy exhibits excellent resistance to corrosion, fatigue, thermal shock, impact, and erosion. However, it is difficult to make films on flexible metallic substrates due to interdiffusion problems between metallic substrates and superconducting overlayers. To overcome this difficulty, it is necessary to use YSZ buffer layer since it will not only limit the interdiffusion process but also minimize the surface microcrack formation due to smaller mismatch between the film and the substrate. In order to enhance the crystallinity of YBCO films on metallic substrates, YSZ buffer layers were grown at various temperatures different from the deposition temperature of YBCO films. On YSZ buffer layer grown at higher temperature than that for depositing YBCO film, the YBCO thin film was found to be textured with c-axis orientation by x-ray diffraction and had a zero-resistance critical temperature of about 85K.

  • PDF

KSLV-I 페어링 공력 가열 시험 (Aerodynamic Heating Test of Payload Fairing of KSLV-I)

  • 최상호;김성룡;김인선
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.448-451
    • /
    • 2008
  • KARI is developing a satellite launch vehicle that is called KSLV(Korea Space Launch Vehicle)-I. During the flight, launch vehicles are exposed to aerodynamic heating conditions while flying at high Mach numbers in the atmosphere. KARI constructed Aerodynamic Thermal Simulation Facility to simulate aerodynamic heating on the ground. ATSF is a facility that can simulate given temperature profile using about 4,000 halogen heaters on fairing model. Aerodynamic heating profile is got from result of thermal analysis using MINIVER, Thermal Desktop, and SINDA/FLUINT. Aerodynamic heating test of fairing of KSLV-I was done using engineering model of payload fairing and Aerodynamic Thermal Simulation Facility. It was found that thermal analytic results show good agreement with aerodynamic heating test results within 6$^{\circ}$C at fairing inner surface. Also it was confirmed that maximum temperature of fairing nose-cone inner surface during flight is lower than allowable temperature limit.

  • PDF

지중송전선로 실시간 송전용량 산정 시스템 개발(I) - 실시간 도체온도 산정 시스템 (The Dynamic Rating System(I) - Real Time Conductor Temperature Monitoring System)

  • 남석현;이충환;이수길;백주흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1455-1457
    • /
    • 2002
  • The real-time dynamic rating system(DRS) can provide the maximum ampacity within required periods, so it can help the transmission-line operation more safely and efficiently. Because the conductor temperature is the main limit of increasing rating current, conductor temperature monitoring(CTM) technology is the basic to DRS. In this paper, real-time CTM was developed for 345kV XLPE cable in tunnel and we have also compared the CTM result of this study with the result according to IEC 287 and JCS 168 thermal parameters.

  • PDF

수질영향평가의 신뢰수준 향상을 위한 기상자료의 검정 (Climate Data Qualification for Water Quality Impact Assessment)

  • 이길하;조홍연
    • 환경영향평가
    • /
    • 제20권5호
    • /
    • pp.601-613
    • /
    • 2011
  • This study is focused on a climate data integrity to improve water quality assessment due to the social development projects. The study is in an attempt to calculate both extreme ranges of weather data measurements and partly provide means to assess qualification of data which fall within the extremes at the 23 meteorological weather stations. Generally speaking, maximum temperature, minimum temperature, relative humidity, dew point temperature are in the range of reasonable accuracy. However, there found some outliers of the brightness sunshine hours in Cheonan station. Also some years in Gwangju, Seoul, Wonju, Busan, and Jeju never reach to their upper limit and perhaps the calibration of the equipment is doubtful. The users need to take cautions in using the brightness sunshine hour data in preparation of water resources planning and management by estimating evapotranspiration and river discharge, and/or growth rate of the algae (phytoplankton).

제상 히터와 냉장고 플라스틱 내벽 사이의 안전거리에 대한 모델링 (Modeling of the Safety Distance between Defrost Heater and Plastic Inner Wall of Refrigerator)

  • 정영;신종민
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.196-202
    • /
    • 2003
  • Two dimensional modeling was carried out to find the safety distance between the defrost heater and the plastic inner wall of domestic refrigerator Estimation was processed for the three cases; the estimation of plastic wall temperature (1) without any protection, (2) with an aluminum foil attached on a wall, and (3) with an aluminum shield installed between heater and wall. The former two cases are found to be dangerous during defrosting process, because the temperatures of inner wall reach above 80'C , which is the upper temperature limit of the wall material. The case with an aluminum shield is considered to be safe by maintaining the temperature of the wall in the range of 6$0^{\circ}C$ during defrosting process.

Al6061 tube의 열처리조건과 온도에 따른 액압성형성에 관한 특성 연구 (A study on the formability with heat treatment and deformation temperature in warm hydroforming of Al 6061 tube)

  • 이혜경;이영선;문영훈;이정환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.255-258
    • /
    • 2005
  • In this study, the effect of heat treatment conditions and deformation temperature on the formability were investigated in warm hydroforming of Al 6061 tube. Full annealing and T6-treatment for heattreatment of Al6061 tube were used in this study. To evaluate the hydroformability, uniaxial tensile test and bulge test were performed between room temperature and $300^{\circ}C$. And measured flow stress was used to simulate the hydroforming of Al 6061. A commercial FEM code, DEFORM2D, was used to calculate the damage and strain variation. The calculated values were efficient to predict the forming limit in hydroforming for real complex shaped part.

  • PDF