Development of Deterioration Prediction Model and Reliability Model for the Cyclic Freeze-Thaw of Concrete Structures (콘크리트구조물의 반복적 동결융해에 대한 수치 해석적 열화 예측 및 신뢰성 모델 개발)

  • Cho, Tae-Jun;Kim, Lee-Hyeon;Cho, Hyo-Nam
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.13-22
    • /
    • 2008
  • The initiation and growth processes of cyclic ice body in porous systems are affected by the thermo-physical and mass transport properties, as well as gradients of temperature and chemical potentials. Furthermore, the diffusivity of deicing chemicals shows significantly higher value under cyclic freeze-thaw conditions. Consequently, the disintegration of concrete structures is aggravated at marine environments, higher altitudes, and northern areas. However, the properties of cyclic freeze-thaw with crack growth and the deterioration by the accumulated damages are hard to identify in tests. In order to predict the accumulated damages by cyclic freeze-thaw, a regression analysis by the response surface method (RSM) is used. The important parameters for cyclic freeze-thawdeterioration of concrete structures, such as water to cement ratio, entrained air pores, and the number of cycles of freezing and thawing, are used to compose the limit state function. The regression equation fitted to the important deterioration criteria, such as accumulated plastic deformation, relative dynamic modulus, or equivalent plastic deformations, were used as the probabilistic evaluations of performance for the degraded structural resistance. The predicted results of relative dynamic modulus and residual strains after 300 cycles of freeze-thaw show very good agreements with the experimental results. The RSM result can be used to predict the probability of occurrence for designer specified critical values. Therefore, it is possible to evaluate the life cycle management of concrete structures considering the accumulated damages due to the cyclic freeze-thaw using the proposed prediction method.

Status of Industrial Environments of Some Industries in Taegu Kyungpook Area (대구지방 산업장에 있어서 건강장애요인과 작업환경검사에 대한 기업인의 수용태도 (ll))

  • Kim, Du-Hui;Seong, Su-Won
    • 월간산업보건
    • /
    • s.8
    • /
    • pp.4-30
    • /
    • 1988
  • Examination of working environments was conducted to get more detailed data about harmful working environments and to make a contribution to more effective management. Study was carried out on 722 factories located in Taegu city and eight counties in Kyungpook Province, Korea, for a period of one year, from February 1 to December 30, 1986. The total number and proportion of workers exposed to harmful material was 37,697, 45.2% among 83,368 workers. The results according to exposed material were as follows: 1. In the case of noise, proportion of exceeding the 8-hour TLV was 59%, Included were nail-cutting in assembly metal manufacturing industry and weaving process in textile. 2. Dust in mill process of coal manufacturing industries exceeded the TLV of second class of dust at all parts and exceeded the TLV at 6% as a whole.: 3. The fields of industry lower than 70 lux of illumination were storage equipment of food, auto-winder of textile, painting of wood wares and coal mixing, and 44% of all cases was lower than standard. 4. As a result of temperature index investigation(WBGT), about 12% of all sujects exceeded limit value. Included parts were rolling machine and reducing room. 5. In the case of organic solvents, TLV was exceeded at about 8%, The parts exceeded TLV according to materials belonged to this category were as follows. 1) Toluene: adhesive work in assembly metal manufacturing 2) Xylene: printing and paint mixing in chemical manufacturing 3) Methyl ethytl ketone: paint mixing in all parts examined and coating machine partially in chemical manufacturing 4) Methyl isobutyl ketone: printing in chemical manufacturing 5) Acetone: vapor polishing in assembly metal manufacturing 6. Among specified chemical materials, the concentration of HC1 in the air in metal assembly manufacturing factory exceeded TLV. in one of three assembly metal manufacturing examined. Others, such as benzene, acetic acid, formic acid, sodium hydroxide, formalin, ammonia, copper, chromate etc. were lower than TLV in its indoor atmospheric concentration. As a whole, the proportion of exceeding TLV was about 0.8% 7. The concentrations of inorganic lead were lower than TLV in all parts examined. The results of this investigation show the fact that current management of working environments is not satisfactory, and so more active management is needed.

  • PDF

A Study on Optimization for Separation of Phenols and Preconcentration-Separation of Trace Phenols in Reversed-Phase Liquid Chromatography (역상 액체 크로마토그래피에서 페놀류의 분리 최적화 및 미량 페놀류의 농축-분리에 관한 연구)

  • Lee Dai Woon;Lee Sung Won;So, Min Jeong;Cho Byung Yun
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.5
    • /
    • pp.513-522
    • /
    • 1993
  • The purpose of this study is to optimize the selectivity of mobile phase solvents for separation of 25 phenols in reversed phase liquid chromatography and to accomplish the simultaneous preconcentration and separation of trace phenols from water samples. Phenols used in this study were classified into three groups, chloro-, methyl-, and nitrophenols. Quaternary solvent mobile phases were employed to improve the selectivity. Overlapping resolution maps(ORM) as a statistical simplex techniques was used to predict the optimum solvent system. Additional criterion such as pH and temperature were also investigated. In order to improve the resolution and decrease the analysis time, isoselective multisolvent gradient elution system was employed with ORM-Prism method. The simultaneous preconcentration and separation of trace phenols from water samples were performed by using XAD-2/Dowex 1-X8 tandem column. When the extraction efficiency was evaluated by sampling up to 1 L of distilled water, recovery of the phenols, except phenol, was above 90% and the limit of detection of the phenols was 5 ppb. The XAD-2/Dowex 1-X8 method was superior to C18 cartridge in terms of recovery and selectivity.

  • PDF

Microfluidic Immuno-Sensor Chip using Electrical Detection System (전기 검출 시스템을 이용한 Microfluidic Immuno-Sensor Chip)

  • Maeng, Joon-Ho;Lee, Byung-Chul;Cho, Chul-Ho;Ko, Yong-Jun;Ahn, Yoo-Min;Cho, Nahm-Gyoo;Lee, Seoung-Hwan;Hwang, Seung-Yong
    • KSBB Journal
    • /
    • v.21 no.5
    • /
    • pp.325-330
    • /
    • 2006
  • This study presents the characterization of an integrated portable microfluidic electrical detection system for fast and low volume immunoassay using polystyrene microbead, which are used as immobilization surfaces. In our chip, a filtration method using the microbead was adopted for sample immobilization and immunogold silver staining(IGSS) was used to increase the electrical signal. The chip is composed of an inexpensive and biocompatible Polydimethylsiloxane(PDMS) layer and Pyrex glass substrate. Platinum microelectrodes for electric signal detection were fabricated on the substrate and microchannel and pillar-type microfilters were formed in the PDMS layer. With a fabricated chip, we reacted antigen and antibody according to the procedures. Then, silver enhancer was injected to increase the size of nanogold particles tagged with the second antibody. As a result, microbeads were connected to each other and formed an electrical bridge between microelectrodes. Resistance measured through the electrodes showed a difference of two orders of magnitude between specific and nonspecific immuno-reactions. The detection limit was 10 ng/ml. The developed immunoassay chip reduced the total analysis time from 3 hours to 50 min. Fast and low-volume biochemical analysis has been successfully achieved with the developed microfilter and immuno-sensor chip, which is integrated to the microfluidic system.

Detection of Hydride Blisters in Zirconium Pressure Tubes using Ultrasonic Mode Conversion and Velocity Ratio Method (초음파 모드 변환 및 속도비 방법에 의한 지르코늄 압력관의 수소화물 블리스터 탐지)

  • Cheong, Yong-Moo;Lee, Dong-Hoon;Kim, Young-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.334-341
    • /
    • 2003
  • When the pressure tubes(f are in contact with the calandria tube(CT) in the pressurized heavy water reactor(PHWR), the temperature difference between inner and outer wall of W results in a thermal diffusion of hydrogen (deuterium) and hydride blisters are formed on the outer surface of PT. Because the hydride blisters and zirconium matrix are acoustically continuous, it is not easy to distinguish the blisters from the matrix with conventional ultrasonic method. An ultrasonic velocity ratio method was developed to detect small hydride blisters on the zirconium pressure tube. Hydride blisters were grown in the PT specimen using a steady state thermal diffusion device. The flight times of longitudinal echo and reflected shear echo from the outer surface were measured accurately. The velocity ratio of the longitudinal wave to the shear wave was calculated and displayed using contour plot. Compared to the conventional flight time method of longitudinal wave, the velocity ratio method shows superior sensitivity to detect smaller blisters as well as better images for the blister shapes. Detectable limit of the outer shape of the hydride blisters was conservatively estimated as $500{\mu}m$, with the same specifications of ultrasonic transducer used in the actual PHWR pressure tube inspection.

Influence of Heating Conditions on the Formation of Acrylamide and Other Products in Asparagine-Glucose Model Reaction System (Model reaction system에서 가열조건이 acrylamide 및 기타 화합물들의 생성에 미치는 영향)

  • Lee Young-Guen
    • Journal of Life Science
    • /
    • v.16 no.2 s.75
    • /
    • pp.323-327
    • /
    • 2006
  • The Formation of acrylamide was studied in Maillard model reaction systems based on asparagine-glucose. The mixture of asparagine and glucose in equal molar ratio, and then heated at 125, 150, 175 and $200^{\circ}C$ for 10, 20 and 30 minute, respectively. The reaction products were extracted with ethyl acetate and methanol, and then isolated and detected on FFAP capillary column and HP-5MS 5% phenyl methyl siloxane column by using GC/MS. Acrylamide was detected only from methanol extracts and on FFAP capillary column, at retention time 23.53 min., and the detection limit was 4.6 ng. Acrylamide content mainly increased with increasing temperature and processing time till $175^{\circ}C$, therefore, maximal acrylamide formation occurred at $175^{\circ}C$ for 10 minute ($116{\mu}g/g$), while, above $175^{\circ}C$, higher temperatures or prolonged processing times caused a decrease of acrylamide levels, finally disappeared at $200^{\circ}C$ for 30 minute. Three major compounds were identified as 1,3-dihydroxypropanone, 2,3-dihydro-3,5-dihydroxy-6-methyl-4H-pyrane-4-one and 5-hydroxymethylfurfural, and three minor compounds also as 5-methylfurfural, 2-acetylpyrrole and N,N-dimethylcyclohexamine, from ethyl acetate or methanol extracts on FFAP or HP-5MS capillary column.

Studies on the Residual Bending Strength of burned Douglas-fir and Western Hemlock soaked with Fire Retardant Chemicals (내화처리(耐火處理) 미송(美松) 및 미삼재(美杉材)의 연소후(燃燒後) 잔유(殘留)휨강도(强度)에 관한 연구(硏究))

  • Lee, Phil-Woo;Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.15-24
    • /
    • 1984
  • The $3{\times}3{\times}30\;cm^3$ sized specimens of Douglas-fir(Pseudotsuga menziesii) and western hemlock(Tsuga heterophylla) in this study were soaked in four fire-retardant solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, and aluminium chloride for 1, 24, 72, 168, and 336 hours. Subsequently they were air-dried and burned at high temperature of ca. $1,800^{\circ}C$ and for short time of 5 minutes. This study estimated the relationship between the adsorbed chemicals and the residual weight ratio or residual bending strength of these partly burned lumbers. The results were as follows; 1) In average amount of chemical adsorption, diammonium phosphate showed the largest and aluminium chloride the smallest regardless of species but monoammonium phosphate was larger in Douglas-fir than that of western hemlock. 2) The amount of chemical adsorption was larger in western hemlock than Douglas-fir on the whole. 3) The amount of chemical adsorption was increased with the increase of soaking time but the rate of increase began to decrease at 200hrs. 4) Residual weight ratios showed no difference between species but showed differences among the chemicals treated i.e. monoammonium phosphate, diammonium phosphate, ammonium sulfate and aluminium chloride in turn from the largest to the smallest. 5) MOR values showed linear increase with the increase of residual weight ratios but showed no difference in species and chemicals respectively. 6) In the relationship between amount of chemical adsorption and MOR, only diammonium phosphate showed the curve of secondary degree with significance in Douglas-fir. 7) The MOE value of burned Douglas-fir lumber increased and showed significance of 99% as the adsorbed chemical amount increased, but among the chemicals only monoammonium phosphate showed significance. The MOE value of burned western hemlock lumber didn't show significance. 8) In only Douglas-fir, the correlation between adsorbed chemical amount and work to proportional limit showed significance in only monoammonium phosphate. And in both Douglas-fir and western hemlock, the correlation between adsorbed chemicals and work to maximum load showed significance in monoammonium phosphate.

  • PDF

Performance Analysis of TPMS Beamformer According to Variance of Antenna Interelement Spacing (안테나 간격 변화에 대한 TPMS 빔형성기 성능분석)

  • Choi, Byung-Sang;Kim, Seong-Min;Hwang, Suk-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.6
    • /
    • pp.907-915
    • /
    • 2013
  • Tire Pressure Monitoring System (TPMS) is an auxiliary safety system for recognizing the condition of tires based on the pressure and temperature data transmitted from the sensor unit installed on a tire of the vehicle. Using TPMS, a driver can frequently check the state of tires and it aids to maintain the optimum running condition of the vehicle. Since TPMS must utilize the wireless communication technique to transmit data from a sensor unit to a signal processing unit installed in the vehicle, it suffers from interference signals caused by various external electrical or electronic devices. In order to suppress high-power interference signals, we employ beamforming techniques based on the uniform linear antenna array. As the number of the antennas is increased, the performance of the interference suppression is improved. However, there is the limit of the number of antennas, installed in the center of a vehicle, because of its size. In this paper, we compare and analyze the performance of the beamformer, when reducing the interelement spacing of antennas, to increase the number of the receiving antennas. For the performance analysis of the beamformers, we consider the switching beamformer and minimum-variance distortionless-response (MVDR) beamformer for TPMS, recently proposed.

Simultaneous Analysis of Bangpungtongseong-san and Its Antioxidant Effect (방풍통성산의 동시분석 및 항산화 효능 연구)

  • Seo, Chang-Seob;Kim, Ohn Soon;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.21 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Objectives : We carry out the simultaneous quantification for quality control of four components in Bangpungtongseong-san (BPTSS) sample. In addition, we assessed the antioxidant effects of BPTSS sample. Methods : The used column for separation and analysis of four compounds was Luna C18 column and column oven temperature was maintained at $40^{\circ}C$. The mobile phase for simultaneous determination consisted of two solvent systems, 1.0% acetic acid in water and 1.0% acetic acid in acetonitrile. High performance liquid chromatography-photodiode array (HPLC-PDA) method for analysis was performed at a flow rate of 1.0 mL/min with PDA detection at 254 and 280 nm. The injection volume was 10 ${\mu}L$. The antioxidant activities of BPTSS were evaluated by measuring free radical scavenging activities on 2,2'-Azinobis-3-ethyl-benzothiazoline-6-sulfonic acid (ABTS) and 1-1-diphenyl-2-picrylhydrazyl (DPPH). The inhibitory effects on low-density lipoprotein (LDL) oxidation were evaluated by the formation of thiobarbituric acid relative substances (TBARS) and relative electrophoretic mobility (REM). Results : Calibration curves were acquired with $r^2{\geq}0.9999$. The values of limit of detection (LOD) and quantification (LOQ) were 0.06-0.29 ${\mu}g/mL$ and 0.20-0.98 ${\mu}g/mL$, respectively. The amounts of geniposide, liquiritin, baicalin, and glycyrrhizin in BPTSS were 5.06, 7.33, 27.56, and 7.81 mg/g, respectively. The BPTSS showed the radical scavenging activity in a dose-dependent manner. The concentration required for 50% reduction (RC50) against ABTS and DPPH radicals were 72.51 ${\mu}g/mL$ and 128.49 ${\mu}g/mL$. Furthermore, GMGHT reduced the oxidation properties of LDL induced by CuSO4. Conclusions : The established HPLC-PDA method will be helpful to improve quality control of BPTSS. In addition, BPTSS has potentials as therapeutic agent on anti-atherosclerosis.

Evaluation of Neurologic Abnormalities After Deep Hypothermic Circulatory Arrest for Pediatric Cardiac Surgery (저체온하 순환정지를 이용한 소아 개심술 후의 신경계 이상에 대한 펑가)

  • Park, Kay-Hyun;Jun, Tae Gook;Chee, Hyun Keun;Lee, Jeong Ryul;Kim, Yong Jin;Rho, Joon Ryang;Suh, Kyung Phill
    • Journal of Chest Surgery
    • /
    • v.29 no.1
    • /
    • pp.14-23
    • /
    • 1996
  • Circulatory arrest under deep hypothermia is an important auxiliary means for cardiac surgery, especially useful in pediatric patients. However, its clinical safety, particularly with regard to the neurologic outcome after long duration of circulatory arrest, is still not established. This study is a review of the eight years'clinical experience of hypothermic circulatory arrest at the Seoul national University Children's Hospital. During an eight-year period from January 1986 through December 1993, a total of 589 consecutive cardiac operations were done using circulatory arrest under deep hypothermia. Among them, 434 consecutive patients, in whom the duration of arrest was 20 minutes or more, are the subject of this study. The duration of arrest ranged from 20 minutes to 82 minutes (mean = 38.7 minutes) under rectal temperature in the range from 12.5$^{\circ}C$ to 25.8$^{\circ}C$. Early neurologic abnormalities occurred in 47 patients : seizure attacks in 28 patients, motor paralyses with or w thout seizure in 12, blindness in 2, and no recovery of consciousness in 5 patients. The rate of incidence of early neurologic abnormalities was calculated at 15.7%. 25 patients showed late neuropsychologic sequelae, such as motor paralysis (9 patients), recurrent seizures (6), developmental delay (8), and definitely low intelligence (2). The rate of incidence of late neurologic sequelae was 8.5%, By statistical analysis, the following factors were identified as the risk factors for post-arrest neurologic abnormalities ; 1) long duration of circulatory arrest, 2) lower-than-ideal body weight, 3) preexisting neurological abnormalities, 4) associated non-cardiovascular congenital anouialies, and 5) low blood pressure during the early post-arrest period. It is concluded that circulatory arrest under deep hypothermia is a relatively safe means for pediatric cardiac surgery with acceptable risk. However, to warrant maximal safety, it is desirable to limit the duration of arrest to less th n 40 minutes. In addition, it is our contention that the early post-arrest period is a very critical period during which maintenance of adequate perfusion pressure in important for the neurologic outcome.

  • PDF