• Title/Summary/Keyword: temperature distribution model

Search Result 1,495, Processing Time 0.027 seconds

Modelling of a Spatial Distribution of the Species Richness of Fishes, Plants, and Birds Using Environmental Factors on a Wide-Ranging Scale1 - Focusing on the Major Drainage Systems in Japan - (광역스케일의 환경 인자를 이용한 어류, 식물, 조류 종수의 공간적 분포에 대한 모델링 - 일본의 주요수계를 중심으로 -)

  • Han, Mi-Deok;Lee, Gi-Bae
    • Korean Journal of Environment and Ecology
    • /
    • v.22 no.4
    • /
    • pp.347-355
    • /
    • 2008
  • This study analyzed and modeled the relationships between the species richness of fish, plant, and bird and environmental factors such as climatic and geographical variables based on data collected from 109 major drainage systems in Japan from 1990 until 2005. As a result, the most parts of the distributions of the fish, plant, and bird species richness were clarified by the average annual atmospheric temperature, dimension of drainage areas, and annual rainfall, respectively. In addition, this study predicted the value of each organism species distributed in national drainage areas in Japan using GAMs(Generalized Additive Models) for each organism model created by environmental factors on a wide-ranging scale, and also mapped out the value. Mapping out the predicted value could make it easier for its managers to newly set up the areas needing to be protected to obtain diversity of the organism species and to assess their availability of conservation for bio-diversity.

Effect of Nozzle Distance and Angle in the Iron-ore Sintering Dual Burner on Flame Characteristics (철광석 소결용 듀얼 버너의 노즐 간격과 각도가 화염 특성에 미치는 영향)

  • Lee, Young-Jun;Hwang, Min-Young;Kim, Gyu-Bo;Song, Ju-Hun;Chang, Young-June;Jeon, Chung-Hwan
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.163-170
    • /
    • 2010
  • The objective of this study is to investigate the combustion characteristics of dual type of sintering burner as a function of design parameters using lab-scale sintering burner through experimental and numerical approaches. Combustion characteristics were evaluated by the radical method. The numerical model was verified as a temperature using R type of thermocouple at the bed surface. The effect of nozzle distance and angle were performed through the CFD analysis, and the comparison of burner types. As a results, dual type burner has more wider and uniform flame distribution than single type burner. Asymmetry and 45 degree angle condition have been suggested as an optimal condition for the ignition of the sintering bed surface.

Study on Algae Occurrence in Daecheong Reservoir (대청호의 조류발생 분석)

  • Cho, Wan Hee;Yum, Kyung Taek;Kim, Jin Soo;Ban, Yang Jin;Chung, Se Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.3
    • /
    • pp.367-380
    • /
    • 2012
  • There are many long and round shape shores due to terrain characteristics in Daecheong reservoir. Therefore it is indicated different spatial distribution of algae every year since the stream is being regulated by these terrain characteristics and reservoir operation about inflow and outflow discharge. Also oversupply of nutrient salt from tributaries of Daecheong reservoir where pollutants were concentrated generates massive growth of algae and depending on hydrological, reservoir operation condition, those proliferated algae at the stagnant tributaries moves to the mainstream of Daecheong reservoir which could create problems of water quality. In this study, it was analyzed the tendency of algae generation by examining algae occurring status for the last 4 years since 2008, and implemented hydraulic analysis at Daecheong reservoir through numerical tracer simulation by applying 3-dimensional hydrodynamic model, ELCOM. Also it was implemented a quantitative analysis of causal relationship based on the algae generation tendency and hydraulic behavior at Daecheong reservoir. Through numerical tracer simulation in this study, it could be noticed the degree of spread of inflow indicated similar trend to the algae occurring status at Daecheong reservoir and verified the different tendency of algae generation in 2011 unlike previous year caused by the rise of water temperature.

The distribution of activation energy and frequency factor for coal pyrolysis and char-air reaction (열분해 및 촤 - 공기 반응시의 활성화 에너지 및 빈도계수 분포)

  • Park, Ho-Young;Kim, Young-Joo
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.9-16
    • /
    • 2009
  • The experimental work has been carried out for the study of pyrolysis and char-air reaction of five coals used in Y power station in Korea. For five coals, the characteristics of pyrolyis and char reaction have been investigated with TGA, and their kinetic parameters were obtained and compared each other. The order of pyrolysis rate for five coals were as follows : Peabody, Flame, MIP, Indominco, Elk valley. The behavior of char - air reaction for five coal chars have been successfully described by the grain model. The rate of char-air reaction gave the maximum value for Flame coal char, on the while Elk valley coal char had the minimum value. For the reaction temperature over 1,000K, Flame coal char - air reaction was very fast compared with other coal chars.

Estimation Method of Evapotranspiration through Vegetation Monitoring over Wide Area (식생해석을 통한 광역증발산량 추정 방법의 개발)

  • 신사철
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.14 no.1
    • /
    • pp.81-88
    • /
    • 1996
  • Remote sensing technique is a probable means to estimate distribution of actual evapotranspiration over wide area in connection with regional characteristics of vegetation and landuse. Factors controlling evapotranspiration from ground are air temperature, humidity, wind, radiation, soil moisture and so on. Not only the vegetation influences directly the evapotranspiration, but also these factors strongly influnce the vegetation at the area. Therefore we can expect high correlation between the evapotranspiration and the vegetation. To grasp the state of vegetation at any point, NDVI calculated from NOAA/AVHRR data is utilized. It can be considered that evapotranspiration at a forest region is linearly proportional to the NDVI. Here, a model which adopts a direct method to estimate actual evapotranspiration is developed by using the relationship between NDVI and evapotranspiration. This method makes possible to estimate evapotranspiration of Korean Peninsula including North Korea where enough meteorological and hydrological data are unavailable.

  • PDF

THE ORBITAL THERMAL ANALYSIS OF HAUSAT-2 AND ITS THERMAL CONTROL SUBSYSTEM PRELIMINARY DESIGN (HAUSAT-2의 궤도 열해석과 열제어계의 예비설계)

  • Lee Mi-Hyeon;Kim Dong-Woon;Chang Young-Keun
    • Bulletin of the Korean Space Science Society
    • /
    • 2005.04a
    • /
    • pp.129-132
    • /
    • 2005
  • This paper describes BAUSAT-2 orbital thermal analysis and preliminary design of thermal control subsystem. To design thermal control subsystem of HAUSAT-2, we have considered active & passive thermal control method based on basic theory and themal equilibrium equation. Using this result, suitable thermal control method and material have been selected. We have designed thermal control subsystem based on analysis of HAUSAT-2's thermal environments on sun synchronous orbit with altitude 650km, inclination $98^{\circ}$ and thermal distribution and range expectation of each HAUSAT-2's surface. Thermal analysis consists of system level, box level and board level analysis. We have completed system level and box level analysis. Till now, board level analysis of main heat dissipation board in progress. Thermal control subsystem has designed according to thermal analysis result. This design is to maintain all of the HAUSAT-2 components within the allowable temperature limits. In future, STM

  • PDF

Analysis on Meteorological Factors related to the Distribution of PM10 Concentration in Busan (부산지역 미세먼지 농도 분포에 따른 기상요소 분석)

  • Kim, Min-Kyoung;Jung, Woo-Sik;Lee, Hwa Woon;Do, Woo-Gon;Cho, Jung-Gu;Lee, Kwi-Ok
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1213-1226
    • /
    • 2013
  • $PM_{10}$ concentration is related to the meteorological variables including to local and synoptic meteorology. In this study the $PM_{10}$ concentrations of Busan in 2007~2011 were analyzed and the days of yellow sand or rainfall which is more than 5 mm were excluded. The sections of $PM_{10}$ concentration were divided according to 10-quantiles, quartiles and 90-quantiles. The 90-quantiles of daily $PM_{10}$ concentration were selected as high concentration dates. In the high concentration dates the daily mean averaged cloudness, mean daily surface wind speed, daily mean surface pressure and PBL height were low and diurnal variation of surface pressure and daily maximum surface temperature were high. When the high $PM_{10}$ dates occurred, the west and south wind blew on the ground and the west wind blew strongly on the 850 hPa. So it seemed that long range transboundary air pollutants made effects on the high concentration dates. The cluster analysis using Hysplit model which is the backward trajectory was made on the high concentration dates. As a result, 3 clusters were extracted and on the short range transboundary cluster the daily mean relative humidity and cloudness were high and PBL height was low.

A Study on the Heat Transfer Performance of an Energy-Nose Section in a Household Refrigerator-Freezer (가정용 냉장고의 에너지 노즈부 열전달 특성에 관한 연구)

  • Lee, Moo-Yeon;Lee, Dong-Yeon;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.6 s.261
    • /
    • pp.574-580
    • /
    • 2007
  • The objective of this article is to present an analysis of all heat transfer paths through the energy nose under closed door conditions when refrigeration system of household refrigerator-freezer is operating on. Both experimental and numerical methods are suggested as a means of determining the overall energy nose load amount as well as the load due to each pathway such as mullion section and F and R sides of the household refrigerator-freezer. In other words, all loads determined in this article are just energy nose and not the loads seen by the refrigeration system. We suggest good ideas for improving the heat transfer losses such as conduction and convection through the energy nose. As we can be known from the experimental test results, it is effective to prevent the heat loss of a mullion section. And energy efficiency is also decreased approximately 6% compared to that of a baseline sample test result. As we can be known from the Ansys 8.1 analysis, it is shown the steady state temperature distribution in figures from 6 to 8. And the direction of the heat flow through the energy nose section is also easily seen from that In conclusion, the article is focused on an energy nose section in household refrigerator-freezer for practical proposes which is the energy saving in a household refrigerator-freezer. And the method suggested may be applied to any make or model to aid in the search for high efficient energy nose section of household side by side refrigerator-freezer as well as top mounted refrigerator-freezer, commercial refrigerator and so on.

Performance Improvement of Stratified Thermal Storage Tank Using Heat Insulator (단열층 사용을 통한 성층 축열조 성능개선)

  • Lim, Se Hwa;Lee, Tae Gyu;Shin, Seungwon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.1
    • /
    • pp.65-72
    • /
    • 2014
  • The purpose of this study is to design a heat insulator for reducing available energy loss in stratified thermal storage tank. Heat insulator is operated by buoyancy effect from density difference between hot and cold water without extra equipment. Analysis model using the Matlab Simulink was developed to estimate the internal temperature distribution in thermal storage tank and also used to select proper material and thickness of the heat insulator. Operational feasibility was confirmed through reduced scale experiment. As a result, heat insulator can effectively delay the formation of thermal boundary layer between hot and cold water. In reduced scale experiment, heat insulator can preserve additional 1540J of available energy. When applied to the real thermal storage tank, increase of 6% thermal storage efficiency can be expected.

Transport of Some Solutes in Blood Plasma Through Poly(2-Hydroxyethyl Methacrylate) Hydrogel Membrane (혈장내 염의 Poly(2-Hydroxyethyl Methacrylate) 격막 투과현상)

  • Jee Jong Gi;Jhon Mu Shik;Ree Tai Kyue
    • Journal of the Korean Chemical Society
    • /
    • v.22 no.5
    • /
    • pp.304-310
    • /
    • 1978
  • The relative permeabilities, distribution coefficients and diffusion coefficient of some salts which are important components in blood plasma through a poly(HEMA) membrane were measured. The crosslinker which was used for preparing the membrane was tetraethylene glycol dimethacrylate(TEGDMA), the weight percentage of the latter was about 2.8. We found that the diffusion coefficients ($D_m$) of the solutes decrease exponentially with increasing molecular weight, and also that $D_m$'s decrease linearly (except urea) with cylindrical radius (a). These facts were explained by a sieve pore flow model. The relative permeability and diffusion coefficient of urea at various temperature were larger than those of other solutes such as glycine, ${\beta}$-alanine, D-glucose, saccharose and maleic acid. The result indicates that the poly(HEMA) membrane might be suitable for hemodialysis application.

  • PDF