• Title/Summary/Keyword: temperature cycles

Search Result 881, Processing Time 0.025 seconds

Status and Prospect of Weed Control Technology for Organic Farming (유기농업을 위한 잡초방제기술의 현재 미래)

  • 전용웅
    • Korean Journal of Organic Agriculture
    • /
    • v.6 no.2
    • /
    • pp.127-140
    • /
    • 1998
  • Organic farming excludes any use of the herbicide. The present paper reviews what can be done for effective weed control with existing weed control technology by farmers crop-ping paddy rice, field crops, vegetables, and fruit trees. If condition of the crop-land-al-lows diversified rotational use of the paddy land as paddy and upland field would minimize weed problem. Practising this is limited in acreage due to extremely limited governmental investment to the land for the purpose. Secondly, rotation of crops in the upland field breaking life cycles of various weeds adapted to each crop should reduce the weed problem. This is also limited as only a few crops are making the farmer profitable. In addition climate and tolerance of crops to high and low temperature. Monsoon rains and poor drainage restrict the freedom of choice. For any crop land year-round multiple cropping in denser planting shall lessen the weed problem, this multiple cropping practiced by 1960s has been abandoned due to laborshortage and increased production cost. Deep flooding the rice is impractical at present in Korean. Mulching crop with transparent, black , or combinated polyethylene sheet, hs been in-creasingly used. Progresses in development and use of mulch with allelopathic crop residues. inexpensive paper mulch, allelopathic crop residues, inexpensive paper mulch, allelopathic crop cultivar development, recently developed ex-perimental weeding machinaries, flamers, microbial herbicides, biological control organisms, soil sterilization techniques have been critically reviewed for their adoption into existing in-tegrated weeding system. Unfortunately, information on cost-benifit, and labor-benefit, for the various methods above mentioned are lacking. Urgent need for the research on rational weeding in organic farming, and herbicide low-input farming is emphasized.

  • PDF

Microstructure and Electrical Properties of Vanadium-doped ${Bi_4}{Ti_3}{O_{12}}$ Thin Films Prepared by Sol-gel Method (졸-겔법으로 성장시킨 바나듐이 도핑된 ${Bi_4}{Ti_3}{O_{12}}$ 박막의 미세구조 및 전기적 특성)

  • Kim, Jong-Guk;Kim, Sang-Su;Choe, Eun-Gyeong;Kim, Jin-Heung;Song, Tae-Gwon;Kim, In-Seong
    • Korean Journal of Materials Research
    • /
    • v.11 no.11
    • /
    • pp.960-964
    • /
    • 2001
  • $Bi_{3.99}Ti_{2.97}V_{0.03}O_{12}$ (BTV) thin films with 3 mol% vanadium doping were Prepared on $Pt/Ti/SiO_2/Si$ substrate by sol-gel method. X-ray diffraction analysis indicated that single-phase layered perovskite were obtained and preferred orientation was not observed. Under the annealing temperature at $600^{\circ}C$, the surface morphology of the BTV thin films had fine-rounded particles and then changed plate-like at $650^{\circ}C$ and $700^{\circ}C$. The remanent polarization $(2P_r)$ and coercive field $(2E_c)$ of $700^{\circ}C$ annealed BTV thin film were 25 $\mu$C/cm$^2$ and 116 kV/cm, respectively. In addition, BTV thin film showed little polarization fatigue during $10_9$ switching cycles. These improved ferroelectric properties were attributed to the increased rattling space and reduced oxygen vacancies by substitution $Ti^{4+}$ ion (68 pm) with smaller $V^{5+}$ ion (59 pm). The dielectric constant and loss were measured 130 and 0.03 at 10 kHz, respectively.

  • PDF

Synthesis of Sulfonated POF-g-Styrene ion Exchange Fibers by Radiation-Induced Polymerization and Properties of Ammonia Adsorption (방사선 중합에 의한 설폰화 POF-g-Styrene 이온교환 섬유의 합성 및 암모니아 흡착)

  • Cho, In-Hee;Baek, Ki-Wan;Lee, Chang-Soo;Nho, Young-Chang;Yoon, Soo-Kyung;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • In this study, the sulfonated ion exchange fiber was synthesized by $Co^{60}\;{\gamma}-ray$ radiation-induced graft copolymerization. Degree of grafting (DG) increased with increasing the total dose and showed the highest value at 50 v/v% styrene monomer. And also, the degree of sulfonation (DS) increased with increasing the DG and reaction temperature. DS showed the maximum value at 20 min. Ion exchange capacity and swelling ratio of ion exchange fibers increased with increasing the DS and their maximum values were 4.76 meq/g and 23.5%, respectively. Ammonia adsorption increased as increasing the ammonia concentration and ion exchange capacity and remained constant over 10 cycles.

A Study on the Structural Integrity Considering the Installation of a Micro-tube Heat Exchanger (미세튜브 열교환기의 장착을 고려한 구조건전성에 관한 연구)

  • Oh, Se Yun;Kim, Tae Jin;Cho, Jong Rae;Jeong, Ho Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.447-451
    • /
    • 2015
  • The objective of this study is to predict the structural characteristics of a heat exchanger mounted on an aircraft engine using finite element analysis. The plastic fracture and life of the heat exchanger were estimated by a thermo-mechanical analysis. Tensile tests were conducted under high temperature conditions (700, 800, 900, 1000 K) using five specimens to obtain the mechanical properties of the Inconel 625 tubes. To assess the structural characteristics of the heat exchanger, the full and partial models were applied under the operating conditions given by the thermo-mechanical and inertial load. As a result, the case, tubesheet, flange, and mounting components have a reasonable safety margin to the allowable stress assuming a fatigue strength of Inconel 625 of 10000 cycles under 1000 K.

Wear of Resin Composites Polymerized by Conventional Halogen Light Curing and Light Emitting Diodes Curing Units (Halogen Light Curing Unit과 Light Emitting Diodes Curing Unit을 이용하여 중합되어진 복합레진의 마멸 특성 비교)

  • Lee Kwon-Yong;Kim Hwan;Park Sung-Ho;Jung Il-Young;Jeon Seung-Beom
    • Tribology and Lubricants
    • /
    • v.21 no.6
    • /
    • pp.268-271
    • /
    • 2005
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15N contact force in a reciprocal sliding motion of sliding distance of 10mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

Wear Of Dental Restorative Composite Resins Cured by Two Different Light Sources (치아 충전용 복합레진의 광중합 광원 종류에 따른 마멸 비교)

  • Kim H.;Lee K.Y.;Park S. H.;Jung I. Y.;Jeon S. B.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.350-354
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion of sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji ?LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

  • PDF

Robust Design and Thermal Fatigue Life Prediction of Anisotropic Conductive Film Flip Chip Package (이방성 전도 필름을 이용한 플립칩 패키지의 열피로 수명 예측 및 강건 설계)

  • Nam, Hyun-Wook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.9
    • /
    • pp.1408-1414
    • /
    • 2004
  • The use of flip-chip technology has many advantages over other approaches for high-density electronic packaging. ACF (anisotropic conductive film) is one of the major flip-chip technologies, which has short chip-to-chip interconnection length, high productivity, and miniaturization of package. In this study, thermal fatigue lift of ACF bonding flip-chip package has been predicted. Elastic and thermal properties of ACF were measured by using DMA and TMA. Temperature dependent nonlinear hi-thermal analysis was conducted and the result was compared with Moire interferometer experiment. Calculated displacement field was well matched with experimental result. Thermal fatigue analysis was also conducted. The maximum shear strain occurs at the outmost located bump. Shear stress-strain curve was obtained to calculate fatigue life. Fatigue model for electronic adhesives was used to predict thermal fatigue life of ACF bonding flip-chip packaging. DOE (Design of Experiment) technique was used to find important design factors. The results show that PCB CTE (Coefficient of Thermal Expansion) and elastic modulus of ACF material are important material parameters. And as important design parameters, chip width, bump pitch and bump width were chose. 2$^{nd}$ DOE was conducted to obtain RSM equation far the choose 3 design parameter. The coefficient of determination ($R^2$) for the calculated RSM equation is 0.99934. Optimum design is conducted using the RSM equation. MMFD (Modified Method for feasible Direction) algorithm is used to optimum design. The optimum value for chip width, bump pitch and bump width were 7.87mm, 430$\mu$m, and 78$\mu$m, respectively. Approximately, 1400 cycles have been expected under optimum conditions. Reliability analysis was conducted to find out guideline for control range of design parameter. Sigma value was calculated with changing standard deviation of design variable. To acquire 6 sigma level thermal fatigue reliability, the Std. Deviation of design parameter should be controlled within 3% of average value.

Cold Shock Response of Leuconostoc mesenteroides SY1 Isolated from Kimchi

  • KIM JONG HWAN;PARK JAE-YONG;JEONG SEON-JU;CHUN JIYEON;KIM JEONG HWAN
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.4
    • /
    • pp.831-837
    • /
    • 2005
  • Low-temperature adaptation and cryoprotection were studied in Leuconostoc mesenteroides SYl, a strain isolated from Kimchi. L. mesenteroides SY1 cells grown in exponential growth phase at $30^{\circ}C$ were exposed to $15^{\circ}C,\;10^{\circ}C$, and $5^{\circ}C$ for 2, 4, and 6 h, respectively, and then frozen at $- 70^{\circ}C$ for 24 h. Survival ratio was measured after the cells were thawed. The freezing-thawing cycles were repeated four times. Preadapted cells survived better than non-adapted control cells, and the highest survival ratio ($96\%$) was observed for cells preadapted for 2 h at $5^{\circ}C$, whereas control cells showed only $22\%$. The 2D gel showed that two proteins (spots A and B) were induced in cells preadapted at lower temperatures. Spots A and B have the same molecular weight (7 kDa), but the pI was 4.6 for spot A and 4.3 for spot B. The first 29 and 15 amino acid sequences from spots A and B were determined, and they were identical, except for one amino acid. A csp gene was cloned, and nucleotide sequencing confirmed that the gene encoded spot A cold shock protein.

Cold Adaptation of Lactobacillus paraplantarum C7 Isolated from Kimchi

  • Kim, Su-Jung;Kim, Jong-Hwan;Park, Jae-Yong;Kim, Han-Taek;Jeong, Seon-Ju;Ha, Yeong-Lae;Yun, Han-Dae;Kim, Jeong-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.1071-1074
    • /
    • 2004
  • The effect of preadaptation at low temperature on cryoprotection was studied for Lactobacillus paraplantarum C7, a bacteriocin producer isolated from kimchi. L paraplantarum C7 cells in their log growth phase were incubated at $15^\circ{C}$, $10^\circ{C}$, or $5^\circ{C}$ for 2, 4, and 6 h, respectively, before being frozen at $-70^\circ{C}$. After 24 h of freezing, viable cells were counted after brief thawing. The freezing-thawing cycles were repeated three more times. Cells preadapted at $10^\circ{C}$ or $5^\circ{C}$ before freezing survived better than control cells, but preadaptation at $15^\circ{C}$ did not confer cryoprotection. Chloramphenicol addition did not destroy the cryoprotection, indicating that protein synthesis was not required for the development of cryoprotection. SDS-PAGE showed induction of a 6.5-kDa protein, a major cold-shock protein, in preadapted cells.

Bioavailability of Tripotassium Dicitrato Bismuthate by ICP-MS in Human Volunteers (ICP-MS를 사용한 구연산비스마스칼륨 (Tripotassium dicitrato bismuthate)의 생체이용률 측정)

  • Kwon, Oh-Seung;Kwon, Jee-Young;Yoon, Ae-Rin;Park, Kyung-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.2
    • /
    • pp.79-84
    • /
    • 2007
  • This study was aimed to establish analytical method of Bi to develop a guideline of the bioequivalence test of tripotassium dicitrato bismuthate (TDB). For this purpose, a simple, specific and sensitive inductively coupled plasma-mass spectrometry (ICP/MS) method were developed and validated in human plasma. Various concentrations of bismuth standard solution (0-25ng/mL) were prepared with distilled water and human blank plasma. To 10mL of the volumetric flasks, 2mL of blank plasma was added with 8ml of distilled water. Bi standard solution was added to prepare the calibration samples and injected into ICP-MS. The plasma samples obtained from volunteers given 3 tablets of bismuth (total 900mg as TDB) were analyzed as described above. As a result, the coefficients of variation were <20% in quantitation limit (0.2 ng/mL) and <15% at the rest of concentrations. The stability test by repeated freezing-thawing cycles showed that the samples were stable only for 24hr. The stability tested for samples with a short-term period of storage at room temperature and pre-treatment prior to the analysis showed very stable over 24hr. In 8 healthy Korean subjects received Denol tablets at the dose of 900mg bismuth, AUC, $C_{max},\;T_{max}$ and half-life $(t_{1/2})$ were determined to be $198.33{\pm}173.78 ng{\cdot}hr/mL,\;64.48{\pm}27.06 ng/mL,\;0.52{\pm}0.21 hr,\;and\;5.15{\pm}2.67 hr$, respectively, from the plasma bismuth concentration-time curves. In conclusion, the method was suitable for the determination of bismuth in human plasma samples and could be applied to bioequivalence test of bismuth tablet.