• Title/Summary/Keyword: temperature cycles

Search Result 881, Processing Time 0.025 seconds

Polypyrrole-Coated Woven Fabric as a Flexible Surface-Heating Element

  • Lee, Jun-Young;Park, Dong-Won;Lim, Jeong-Ok
    • Macromolecular Research
    • /
    • v.11 no.6
    • /
    • pp.481-487
    • /
    • 2003
  • Polypyrrole (PPy) was coated sequentially by chemical and electrochemical methods on a woven fabric, giving rise to a fabric having high electrical conductivity. We investigated the effects of the preparation conditions on the various properties of the resulting fabric. The PPy-coated fabric with optimum properties was obtained when it was prepared sequentially by chemical polymerization at the elevated temperature of 100$^{\circ}C$ under a pressure of 0.9 kgf/$\textrm{cm}^2$ and then electrochemical polymerization with a 3.06 mA/$\textrm{cm}^2$ current density at 25 $^{\circ}C$ for 2 hrs with the separator plate. The surface resistivity of the resulting fabric was as low as 5 Ω/$\square$ .The PPy-coated fabric prepared under the optimum conditions showed practically applicable heat generating property. When electrical power was supplied to the fabric using a commercial battery for a mobile phone (3.6 V, LGLl-AHM), the temperature of the fabric increased very quickly from room temperature to ca. 55 $^{\circ}C$ within 2 min and was maintained for ca. 80 min at that temperature. The heat generating property of the fabric was extremely stable, exhibiting similar behavior over 10 repeated cycles. Therefore, we suggest that the PPy-coated fabric in this study may be practically useful for many applications, including flexible, portable surface-heating elements for medical or other applications.

A Study on the Accelerated Life Test for Evaluating the Reliability of Nickel-Cadmium Batteries

  • Kwon, Soo-Ho;Huh, Yang-Hyun;Lim, Tae-Jin
    • International Journal of Reliability and Applications
    • /
    • v.1 no.1
    • /
    • pp.89-104
    • /
    • 2000
  • Accelerated testing consists of a variety of test methods for shortening the life of products or hastening the degradation of their performance. This paper presents practical, modern statistical methods for evaluating the reliability of Nickel-Cadmium batteries at their design temperature of 2$0^{\circ}C$ by accelerated life test. Batteries have been life tested at three high temperature conditions, 50, 60, 7$0^{\circ}C$, respectively to yield failures quickly. The failures have been observed and judged by means of charge and discharge current integration. Analyses of life data from those conditions resulted in the Weibull distribution, which has been verified on the ground of the Kolmogorov-smirnov test and the pairwise t-test. Life data are modeled according to the Arrhenius life-temperature relationship. The mean life of tested batteries is assessed at about 590 cycles, and the activation energy of this chemical reaction is concluded to be 0.39eV as results. This study provides procedures for estimating the reliability of batteries in a short period, which has little been possible in domestic industries. The results can be applied in many fields such as proof testing, acceptance testing, and estimating assurance periods.

  • PDF

Failure Analysis of Commercial Water-Repellent Coatings for High Temperature Plant (플랜트 부품용 상용 발수코팅의 고온 환경 고장 특성 비교 분석)

  • Lee, Byung-Ho;Kim, Hye-young;Hyeon, Chang-young;Byeon, Jai-Won
    • Journal of Applied Reliability
    • /
    • v.17 no.1
    • /
    • pp.78-82
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate failure characteristic and mechanism of four commercial water-repellent coatings for elevated temperature machinery applications. Method: Thermal degradation was performed for up to 64 thermal cycles. 1 cycle consists of 15 minute holding at 523K under 300rpm revolution and 15 minute-natural cooling. Contact angle was measured and microstructure of the coating layer was observed by using a scanning electron microscope. Results: Four kinds of commercial repellent coating showed hydrophobic or super-hydrophobic property implying that all coatings are suitable for room temperature application. Contact angle of three kinds of commercial coatings decreased rapidly after thermal exposure, while only one specimen having hydrophobic surface showed extremely slow degradation. Conclusion: Observed decrease in contact angle of the coatings were attributed to formation of macro-sized pores and disappearance of micro-protrusion during thermal exposure. Optimum water-repellent coating needs to be selected under the consideration of initial contact angle as sell as service temperature.

FEM Analysis on Temperature Distribution and Thermal Stress of a Brake Drum for Large Commercial Vehicle (대형 상용차용 브레이크 드럼의 온도 분포 및 열응력에 관한 유한요소 해석)

  • Kim, Ho-Kyung;Lee, Young-In;Joo, Se-Min
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.7-13
    • /
    • 2006
  • A transient heat transfer and thermal stress analysis for a brake drum of commercial vehicles have been performed by ANSYS code in the cases of single braking and the repeated braking condition. The temperature and thermal stress distributions in the brake drum under various braking conditions were obtained using a two-dimensional axisymmetric model. In case of deceleration of 0.3G with an initial vehicle speed of 60km/h, the maximum temperature in the drum was $87.6^{\circ}C$ after braking application. The maximum stress of 78.7MPa in the drum occurred at the intersection between the flange and hat under a condition in which repeated 15 cycles braking with an initial vehicle speed of 60km/h and a deceleration of 0.3G is applied to according to KS R1129. The maximum stress value is much lower than the yield strength of drum material(FC250).

Performance Analysis of Ammonia-Water Regenerative Rankine Cycles for Use of Low-Temperature Energy Source (저온 열원 활용을 위한 암모니아-물 재생 랭킨 사이클의 성능 해석)

  • Kim, Kyoung-Hoon;Han, Chul-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • It is a great interest to convert more energy in the heat source into the power and to improve the efficiency of power generating processes. Since the efficiency of power generating processes becomes poorer as the temperature of the source decreases, to use an ammonia-water mixture instead of water as working fluid is a possible way to improve the efficiency of the system. In this work performance of ammonia-water regenerative Rankine cycle is investigated for the purpose of extracting maximum power from low-temperature waste heat in the form of sensible energy. Special attention is paid to the effect of system parameters such as mass fraction of ammonia and turbine inlet pressure on the characteristics of system. Results show that the power output increases with the mass fraction of ammonia in the mixture, however workable range of the mass fraction becomes narrower as turbine inlet pressure increases and is able to reach 16.5kW per unit mass flow rate of source air at $180^{\circ}C$.

Microstructural and Mechanical Characteristics of A356 Alloy Cast by Semi-Solid Squeeze Process (반응고 공정 가압 주조한 A356합금의 미세조직 및 기계적 특성)

  • Kim, Sug-Won;Kang, Yeun-Cheul;Kim, Dong-Kun;Kumai, Sinji
    • Journal of Korea Foundry Society
    • /
    • v.20 no.4
    • /
    • pp.269-276
    • /
    • 2000
  • So far, the study on semi-solid process has been carried out to develop and research new advanced materials without some casting defects. In this study, A356 billets consisted of various dendritic shapes were prepared using electro-magnetic stirring process continuously. As-cast respectively has liquidus temperature of $625.6^{\circ}C$ and solidus temperature of $573.55^{\circ}C$ A356 slugs were reheated homogeneously at different temperatures of 580, 590 and $605^{\circ}C$, followed by squeezing in a mold insulated with applied pressures(0, 25, 50 and 70 MPa). In order to investigate on aging responce for casts, 50 MPa squeezed specimen among all specimens was prepared in aging treatments, which conditions are aging temperature of $160^{\circ}C$ and holding times of 0, 45, 90, 270, 360, 720, 1440 and 2880 min after solution treatment ($540^{\circ}C$ for 10 hr). SSM ingot with the output velocity of 150mm/min appeared more spheroidal shape and fine structure than that with the output velocity of 250 mm/min. According to increasing in reheating temperature, numbers of fatigue cycles, U.T.S and elongation increased at same time.

  • PDF

The Influence of Temperature on Low Cycle Fatigue Behavior of Prior Cold Worked 316L Stainless Steel (I) - Monotonic and Cyclic Behavior - (냉간 가공된 316L 스테인리스강의 저주기 피로 거동에 미치는 온도의 영향 (I) - 인장 및 반복 거동 -)

  • Hong, Seong-Gu;Yoon, Sam-Son;Lee, Soon-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.4
    • /
    • pp.333-342
    • /
    • 2004
  • Tensile and low cycle fatigue (LCF) tests on prior cold worked 316L stainless steel were carried out at various temperatures from room temperature to 650$^{\circ}C$. At all test temperatures, cold worked material showed the tendency of higher strength and lower ductility compared with those of solution treated material. The embrittlement of material occurred in the temperature region from 300$^{\circ}C$ to 600$^{\circ}C$ due to dynamic strain aging. Following initial cyclic hardening for a few cycles, cycling softening was observed to dominate until failure occurred during LCF deformation, and the cyclic softening behavior strongly depended on temperature and strain amplitude. Non-Masing behavior was observed at all test temperatures and hysteresis energy curve method was employed to describe the stress-strain hysteresis loops at half$.$life. The prediction shows a good agreement with the experimental results.

Influence of Thermal Cycle Test of a 22.9 kV High Temperature Superconducting Cable System (22.9 kV 초전도케이블 시스템의 Thermal Cycle Test 영향)

  • Sohn, S.H.;Lim, J.H.;Yang, H.S.;Ryoo, H.S.;Choi, H.O.;Sung, T.H.;Kim, D.L.;Hwang, S.D.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.242-242
    • /
    • 2007
  • To verify the applicability of High Temperature Superconducting (HTS) cable system into the real grid, the HTS cable system with the specification of 22.9 kV, 1250 A, 100 m long was installed in the second quarter of 2006, and the long term field test has been in progress at the KEPCO's Gochang power testing yard. Apart from the conventional power cable, HTS cable system requires sufficient thermo-mechanical strength to endure a large temperature difference. To date, the KEPCO HTS cable system was cooled down and warmed to the room temperature several times to investigate the influence of thermal cycles experimentally. Dielectric properties, critical current dependance and heat losses were evaluated at each step of thermal cycle. The test results showed that thermal cycle did not induce the degradation of dielectric properties, and the critical current decreased to 5 % of the initial value.

  • PDF

Effects of Environmental Factors on the Growth of Gametophytes and Young Sporophytes of Eisenia bicyclis (Kjellman) Setchell (대황(Eisenia bicyclis) 배우체와 아포체의 생장에 미치는 환경 인자의 영향)

  • Lee, Min-Jeong;Kim, Nam-Gil
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.12 no.2
    • /
    • pp.115-122
    • /
    • 2020
  • Eisenia bicyclis, a perennial macroalga is a primary producer of in the ocean, It has been identified as a key species that plays a vital role in maintaining the ecosystem stability. Also, it is an important target in marine afforestation projects and useful marine organisms. In addition, E. bicyclis is used as a health food for humans. This study investigated the effect of water temperature, light (photon irradiance), and duration of light (photoperiod) on the growth of gametophytes and young sporophytes of E. bicyclis. The germination and growth of the zoospores of E. bicyclis were examined at five temperatures (5℃, 10℃, 15℃, 20℃ and 25℃), four intensities of photon irradiance (10, 20, 40, and 80 μmol m-2s-1), and photoperiods (14:10 and 10:14 light/dark cycles). The zoospores released from mature plant germinated into the gametophytes under all experimental conditions. The gametophytes were able to grow at water temperature 5℃-25℃ and mature at 10℃-20℃. The optimal range of water temperature for the maturation of the gametophyte was 15℃-20℃. At 25℃, E. bicyclis gametophytes grew rapidly but did not mature. The optimal culture conditions for the growth of young sporophytes grew slowly in low temperature and photon irradiances.

Electron Firehose Instabilities in High-β Intracluster Medium

  • Kim, Sunjung;Ha, Ji-Hoon;Ryu, Dongsu;Kang, Hyesung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.55.2-55.2
    • /
    • 2019
  • The firehose instability is driven by a pressure anisotropy in a magnetized plasma when the temperature along the magnetic field is higher than the perpendicular temperature. Such condition occurs commonly in astrophysical and space environments, for instance, when there are beams aligned with the background magnetic field. Recently, it was argued that, in weak quasi-perpendicular shocks in the high-β intracluster medium (ICM), shock-reflected electrons propagating upstream cause the temperature anisotropy. This electron temperature anisotropy can trigger the electron firehose instability (EFI), which excites oblique waves in the shock foot. Scattering of electrons by these waves enables multiple cycles of shock drift acceleration (SDA) in the preshock region, leading to the electron injection to diffusive shock acceleration (DSA). In the study, the kinetic properties of the EFI are examined by the linear stability analysis based on the kinetic Vlasov-Maxwell theory and then further investigated by 2D Particle-in-Cell (PIC) simulations, especially focusing on those in high-β (β~100) plasmas. We then discuss the basic properties of the firehose instability, and the implication of our work on electron acceleration in ICM shock.

  • PDF