• 제목/요약/키워드: temperature control feedback

Search Result 159, Processing Time 0.034 seconds

A 12.5-Gb/s Optical Transmitter Using an Auto-power and -modulation Control

  • Oh, Won-Seok;Park, Kang-Yeob;Im, Young-Min;Kim, Hwe-Kyung
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.434-438
    • /
    • 2009
  • In this paper, a 12.5-Gb/s optical transmitter is implemented using 0.13-${\mu}m$ CMOS technology. The optical transmitter that we constructed compensates temperature effects of VCSEL (Vertical cavity surface emitting laser) using auto-power control (APC) and auto-modulation control (AMC). An external monitoring photodiode (MPD) detects optical power and modulation. The proposed APC and AMC demonstrate 5$\sim$20-mA of bias-current control and 5$\sim$20-mA of modulation-current control, respectively. To enhance the bandwidth of the optical transmitter, an active feedback amplifier with negative capacitance compensation is exploited. The whole chip consumes only 140.4-mW of DC power at a single 1.8-V supply under the maximum modulation and bias currents, and occupies the area of 1280-${\mu}m$ by 330-${\mu}m$ excluding bonding pads.

The Speed and Position Sensorless Control of Switched Reluctance Motor using Binary Observer

  • Yang, Lee-Woo;Kim, Young-Cho;Choi, Jung-Soo;Kim, Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.736-741
    • /
    • 1998
  • It is well known that an encoder or a resolver is necessary to obtain the position data for speed or position control Generally utilized speed sensors are mal-affected by the EMI, dusty, and high temperature surroundings. Therefore, the speed and position sensorless controls using observers have been studied widely. In this paper, the binary observer which is composed of two feedback regulation loops to control the speed of SRM(Switched Reluctance Motor) is applied. One loop compensates the control input directly like the sliding mode control, and the other one compensates the system parameters indirectly. This observer is constructed on the foundation of variable structure control on the foundation of variable structure control theory and has the inertial term for the varying parameter. The validities of this proposed method is proved by experiments.

  • PDF

Modified algorithmic LMI design with applications in aerospace vehicles

  • Chen, Tim;Gu, Anzaldi;Hsieh, Chiayen;Xu, Giustolisi;Wang, Cheng;Chen, C.Y.J.
    • Advances in aircraft and spacecraft science
    • /
    • v.8 no.1
    • /
    • pp.69-85
    • /
    • 2021
  • A modified fuzzy mechanical control of large-scale multiple time delayed dynamic systems in states is considered in this paper. To do this, at the first level, a two-step strategy is proposed to divide a large system into several interconnected subsystems. As a modified fuzzy control command, the next was received as feedback theory based on the energetic function and the LMI optimal stability criteria which allow researchers to solve this problem and have the whole system in asymptotically stability. Modeling the Fisher equation and the temperature gauge for high-speed aircraft and spacecraft shows that the calculation method is efficient.

Development of Automatic Nutrient-Solution Control System Using a Low -Cost and Precise Liquid Metering Device (액제 정밀계량장치를 이용한 액제 자동조제 시스템개발)

  • 류관희;홍순호;이규철;이정훈;황호준
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1997.06c
    • /
    • pp.89-98
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution control system for small-scale growers. The nutrient-solution control system consisted of a low-cost and precise metering device and a personal computer. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-soIution. The performance of the nutrient-solution control system was evaluated through the control of EC and pH while compared with those of commercial nutrient-solution control system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. An automatic nutrient-solution control system based on a low-cost and precise metering device was developed. 2. The developed system controlled EC and pH within $\pm$0.05 mS/cm and $\pm$0.2 pH full scale error respectively at $24^{/circ}C$. 3. When using the commercial system, the controlled values of EC and pH of the 500l of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at $22^{/circ}C$. 4. The developed nutrient-solution control system showed $\pm$0.05 mS/cm of deviation from the setting EC value over the experimental cultivation period. 5. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

Maximum Current Estimation Method for the Backup of Current Sensor Faults

  • Kim, Jae-Yeon;Park, Si-Hyun;Suh, Young-Suk
    • Journal of information and communication convergence engineering
    • /
    • v.18 no.3
    • /
    • pp.201-206
    • /
    • 2020
  • This paper presents a new method for controlling the current of lighting LEDs without current sensors. This method can be used as backup against LED current sensor faults. LED lighting requires a circuit with a constant current in order to maintain the same brightness when the ambient temperature changes. Therefore, we propose a new current estimation method to provide backup in case of current sensor faults based on the calculation of the inductor current. In the fabricated circuit, the average current changes from 144.03 mA to 155.97 mA when the ambient temperature changes from 0℃ to 60℃. The application of this study can enable the fabrication of a driving IC for LEDs in the form of a single chip without sensing resistors. This is expected to reduce the complexity of the peripheral circuit and enable precise feedback control.

On-Line Induction of Fermentation with Reconbinant Cells : Part 1. Construction of Control Hardware (유전자 재조합 세포 발효의 온.라인 유도 : 제 1부. 자동 제어 하드웨어 제작)

  • 이철균;최차용
    • KSBB Journal
    • /
    • v.4 no.3
    • /
    • pp.197-202
    • /
    • 1989
  • The existing analog controllers for typical fermentation variables such as rpm and temperature were properly modified in order to be interiaced with microcomputers. Other necessary corrections like the impedance matching, the ground isolation, and the signal range adjustment were done for the successful interfacing between fermentor detectors and computers and for the eventual on-line feedback control of temperature and DO and the induction of the fermentation process with recombinant cells.

  • PDF

A Study on Correlation between A/F and ion signal in a Constant-Volume Chamber Using Spark-plug Ionization Probe Itself (정적챔버에서 스파크 플러그 이온프로브를 이용한 공연비와 이온신호와의 상관관계에 대한 연구)

  • Park, Jong-Il;Chun, Kwang-Min;Hahn, Jae-Won;Park, Chul-Woong
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.223-229
    • /
    • 2002
  • Spark plug ionization signal could be useful in an internal combustion engine as a feedback signal for combustion diagnostics such as misfire detection, knocking detection and lambda control, but the signal has high level of cyclic fluctuation in an internal combustion engine due to residual gas, pressure, temperature, mixture composition in the spark gap. Because of this reason it is very difficult to apply ion signal to commercial engine control. In this Study, a correlation between A/F and spark plug ionization signal was studied in a constant volume chamber. Constant volume chamber with gas phase fuel(Propane) has homogeneous fuel composition , no mixture flow, same pressure and temperature on each test. The results show that mean chemi-ion signal has the highest correlation with A/F and intial pressure change has on effect on the thermal-ion signal and not on chemi-ion signal.

  • PDF

Active vibration control of nonlinear stiffened FG cylindrical shell under periodic loads

  • Ahmadi, Habib;Foroutan, Kamran
    • Smart Structures and Systems
    • /
    • v.25 no.6
    • /
    • pp.643-655
    • /
    • 2020
  • Active control of nonlinear vibration of stiffened functionally graded (SFG) cylindrical shell is studied in this paper. The system is subjected to axial and transverse periodic loads in the presence of thermal uncertainty. The material composition is considered to be continuously graded in the thickness direction, also these properties depend on temperature. The relations of strain-displacement are derived based on the classical shell theory and the von Kármán equations. For modeling the stiffeners on the cylindrical shell surface, the smeared stiffener technique is used. The Galerkin method is used to discretize the partial differential equations of motion. Some comparisons are made to validate the SFG model. For suppression of the nonlinear vibration, the linear and nonlinear control strategies are applied. For control objectives, the piezoelectric actuator is attached to the external surface of the shell and the thin ring piezoelectric sensor is attached to the middle internal surface of shell. The effect of PID, feedback linearization and sliding mode control on the suppression of vibration for SFG cylindrical shell is presented.

Optimum Controller Design of a Water Cooler for Machine Tools Based on the State Space Model (상태공간 모델링에 의한 공작기계용 수냉각기의 최적제어기 설계)

  • Jeong, Seok-Kwon;Kim, Sang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.782-790
    • /
    • 2011
  • Typical temperature control methods of a cooler for machine tools are hot-gas bypass and compressor variable speed control. The hot-gas bypass system has been widely used to control the cooler temperature in many general industrial fields. On the contrary, the compressor variable speed control is focused on special fields such as aerospace and high precision machine tools which need high precision control. The variable speed control system usually has two control variables such as target temperature and superheat. In other words, the variable speed control system is basically multi-input multi-output(MIMO) system. In spite of MIMO system, the proportional integral derivative(PID) feedback control methodology that based on single-input single-output (SISO) system is generally used for designing the variable speed control system. Therefore, it is inevitable to describe transfer functions for dynamic behaviors of every controlled variables and decide the PID gains with tremendous iteration process. Moreover, the designed PID gains do not provide optimum system performances. To solve these problems, high performance controller design method based on a state space model is suggested in this paper. An optimum controller is designed to minimize both control errors and energy inputs. This method was more simple to describe dynamic behaviors and easier to design the cooler controller which is MIMO system.

Design of phase tracking feedback compensator for stabilization of single mode fiber-optic Mach-Zehnder interferometer (단일모드 광섬유 Mach-Zehnder간섭계의 안정화를 위한 추적궤환 보상기의 설계)

  • 이기완;오문수;홍봉식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.547-552
    • /
    • 1989
  • Single mode optical fiber interferometeric sensors using phase tracking homodyne detection are typically susceptible to environmentally induced temperature fluctuations and other types of disturbances. In this paper compensator is described, which is a simple and effective phase tracking feedback electronic circuit must be output signal stabilized to achieve maximln sensitivity and linearity of Mach-Zehnder fiber-optic interferomter in the presence of differential phase drift. The phase tracking range of the piezoelectric cylinder in the reference arm is .+-.3.7.pi.rad, and the probe mass about 1 gram in the sensing ann was used for measurements of the gravity acceleration.

  • PDF