• Title/Summary/Keyword: temperature changing

Search Result 1,604, Processing Time 0.032 seconds

Thermal Behavior of the Layered Structure in Metal-dodecanesulfonate intercalation compounds, [M($H_2O$)$_6$](C$_12$H$_25$SO$_3$)$_2$.x$H_2O$ (M=Co, Cu) (도데칸술폰이 삽입된 금속 화합물, [M($H_2O$)$_6$(C$_12$H$_25$SO$_3$)$_2$.x$H_2O$ (M=Co, Cu)의 층상 구조의 열적 성질)

  • 허영덕;박성훈;전태현
    • Journal of the Korean institute of surface engineering
    • /
    • v.33 no.1
    • /
    • pp.25-33
    • /
    • 2000
  • The synthesis and characterization of intercalated compound of dodecanesulfornate into hydrated metal, [M($H_2$O)\ulcorner](C\ulcornerH\ulcorner$SO_3$)$_2$.$xH_2$O (M=Co, Cu) was presented. The compounds shows a layered structure which was determined by powder X-ray diffraction. Thermal behavior of the layered structure was investigated using thermal analysis, and FT-IR spectroscopy by varying the temperature. The increase in layer spacing of the products by increasing the temperature is also checked by X-ray diffraction. We can suggest three kinds of layered structure by varying the temperature, which is accompanied by changing the intercalated dodecanesulfonate from the monolayer to the bilayer structure or changing the tilt angle.

  • PDF

Optical Characteristics of LED module due to changing Ambient Temperature and Driving Current (주변온도와 인가전류 변화에 따른 LED module의 광학적 특성)

  • Lee, Seung-Min;Aung, Aye Thida;Yang, Jong-Kyung;Yim, Youn-Chan;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.377-378
    • /
    • 2007
  • In this paper, we were confirmed the optical characteristics of LED module by changing ambient temperature and driving current. When we supplied same driving current, the brightness quality drops due to an increased ambient temperature. The difference of brightness properties came out more large according to an increased driving current. Moreover, peak wavelength become shifted by long wavelength and declined output power by increasing driving current.

  • PDF

Effects of Interphase Condition and Short-fiber Content on the Fatigue Properties of Reinforced Rubber (계면상 조건과 단섬유 함유량이 강화고무의 피로특성에 미치는 영향)

  • 류상렬;이동주
    • Composites Research
    • /
    • v.13 no.5
    • /
    • pp.10-17
    • /
    • 2000
  • The fatigue properties of short nylon66 fiber reinforced Chloroprene rubber have been investigated as functions of interphase conditions and fiber content. The spring constant of rubber decreased about 21% after the fatigue test. On the contrary, that of reinforced rubber increased in all cases. The changing rate of spring constant for reinforced rubber decreased with increasing fiber content. This means that the better interphase condition, the smaller changing rate of spring constant. Temperature of matrix increased about 2.5 times and one of reinforced rubber showed 1.7∼2 times up after the test. The changing rate of temperature for reinforced rubber during fatigue test decreased with increasing fiber content. It is found that the better interphase condition, the smaller changing rate of specimen temperature at the same fiber content. Double coatings of bonding agent 402 and rubber solution became the best interphase model in this study. And, we have investigated the possibility of applying short-fiber reinforced rubber to automotive engine mount rubber, bush and stopper.

  • PDF

Experimental Study on High Temperature Air Regenerative Combustion System (축열식 고온공기 연소시스템에 대한 실험적 연구)

  • Yang, B.O.;Lim, I.G.
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.189-200
    • /
    • 1999
  • Combustion characteristics of a regenerative combustor for high temperature air combustion have experimentally studied. Temperature measurement on regenerative ceramic material and combustor has been carried out with changing equivalence ratio at constant turn-over period. Stable and unstable combustion region have been found and also detailed averaged temperature profile with respect to various air flow conditions have been obtained.

  • PDF

An Experimental Study of Verification for PEMFC's 1-Dimensional Simulation (PEMFC 1차원 시뮬레이션 검증을 위한 실험적 연구)

  • Moon, Cheor-Eon;Ahn, Seong-Yool;Yang, Jang-Sik;Choi, Gyung-Min;Kim, Duck-Jool
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.191-195
    • /
    • 2007
  • In this study, we estimated the performance of PEMFC's unit cell as changing operating temperature in different inlet humidity condition at cathode side but anode dry, and tried to match experimental results with 1-dimensional simulation. We used $Nafion^{\circledR}112$ membrane and a self-manufactured PEMFC with active area of $25cm^{2}$ was used in this study. The range of operating temperature was $40{\sim}70^{\circ}C$ and oxygen through bubbled humidity chamber was supplied $0{\sim}80$% humidity condition as changing water temperature in humidity chamber. For figuring out governing equations, represent water contents in electrolyte membrane, the linear forward difference method was applied about time progress and quadratic central difference method was used about space progress. It was assumed that pressure terms were linearly changed due to thin electrolyte membrane. In low operating temperature condition, $40{\sim}60^{\circ}C$, increasing temperature rarely effected cell performance but we can see performance drop at $70^{\circ}C$. By modifying Henrry's constant and/or diffusion coefficient, the modified one-dimensional model was accomplished for calculation.

  • PDF

The Change of Dielectric Constant and Leakage Current of PVA (polyvinyl alchol) by Increasing Temperature and Concentration

  • Lee, Tae-Ho;Jang, Jae-Ho;Nam, Ho-Seong;Jo, Han-Na;No, Yong-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.388.1-388.1
    • /
    • 2014
  • The performance of PVA(polyvinyl alchol) is better than another organic dielectric material. Therefore, PVA has been researched for organic and in-organic dielectric material. But research of changing PVA's dielectric constant and leakage current by increasing temperature and concentration was insigificant. We try to find pure PVA and cross-linked PVA's characteristic of dielectric by changing temperature and concentration. 5/10/15wt% PVA concentration (5% interval) was in progress, PVA at $100/150/200/250^{\circ}C$ ($50^{\circ}C$ interval) of experiments was conducted in relation to temperature. The higher the concentration, leakage currents decrease, and dielectric constant is increased. With regard to temperature, we could not see a big change of leakage current and dielectric constant of pure PVA until $200^{\circ}C$. However, we could see a tendency to increase significantly at $250^{\circ}C$. Also, leakage current and dielectric constant of cross-linked PVA gradually increased from at $100^{\circ}C$ to $200^{\circ}C$ and then sharply increased from at $250^{\circ}C$. We tried to find that PVA's inner bonds(hydroxyl group (OH-) lead to the results.

  • PDF

A Study on Annealing Cycle Control Temperature of Hi - CON/2 BAF and HNx BAF (Hi-CON/H2 BAF와 HNx BAF의 소둔사이클 제어온도에 관한 연구)

  • 김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.114-122
    • /
    • 1994
  • A cold temperature control system for the BAF(batch annealing furnace) has been established in order to reduce energy consumption to imrpove productivity and stabilize the properties of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, changing annealing cycle time according to BAF temperature with time during heating and actual temperature measurements cold spot during soaking. The results of the temperature variation effect on the batch annealing are as follows. 1) Cooling rate is increasing gradually with increasing atmospheric gas flow, but heating rate is hardly increasing without atmospheric gas component. Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas and annealing cycle time is reduce to 2.7 times. 2) With enlarging the difference between furnace temperature and soaking temperature at the HNx BAF, heating time becomes short, but cooling time is indifferent. 3) If temperature difference of 300.deg. C in the temperature change of cold spot according to the annealing cycle control temperature, Hi-CON/H2BAF is interchanging at each other at 26hours, but HNxBAF at 50 hours. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1219 mm width coil must be 2.5 hours longer then that of 914mm width coil for the same coil weight at Hi-CON/H2BAF. But, it is necessary to make 2 hours longer at HNxBAF.

  • PDF

Hypersonic Viscous Interaction of Wedge Flows (극초음속 쐐기 유동의 Viscous Interaction)

  • Kim K. H.;Rho O. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1996.05a
    • /
    • pp.40-45
    • /
    • 1996
  • This paper discribes the viscous interaction of Hypersonic Wedge Flows using Roe FDS and AUSM+. For this purpose we developed the frozen and the equilibrium code and numerically simulated the viscous interaction by changing the surface temperature and the mach number. We used curve fitting data in NASA Reference Publication 1181, 1260 to calculate equilibrium properties. We compare the equilibrium flow with the frozen flow. We conclude that the mach number and the surface temperature are significant parameters, as the surface temperature and the mach number increase the viscous interaction becomes stronger, and we must consider high-temperature effects in hypersonic flow

  • PDF

Construction of a Temperature Controlled Expression Ve e tor in Saccharumy ces cerevisiae (Saccharomyces cerevisiae를 이용한 온도조절형 발현 Vector의 개발)

  • 최진옥;황용일
    • Microbiology and Biotechnology Letters
    • /
    • v.21 no.3
    • /
    • pp.214-220
    • /
    • 1993
  • The mating type a of yeast, Saccharomyces cerevisiae mutant with hmla2-102 and sir3-8ts was changed to type alpha by changing the growth temperature from 25C to 35C. A temperature-sensitive expression vector system was constructed using mating factor alpha1 (Mfalpha1) gene encoding alpha factor which is expressed in the type alpha cells. Vectors with different copy numbers were constructed by joining the promoter and pre or prepro-secretion single sequence of Mfalpha1 to promoterless PHO5' gene as a reporter gene.

  • PDF