• 제목/요약/키워드: temperature change coefficient

검색결과 527건 처리시간 0.025초

이동통신 단말기에 이용되는 적층 칩 써미스터 제작 (The Fabrication of Mulilayer Chip NTC Thermistor for Mobile Communication Telephone)

  • 윤중락;이헌응;김지균;이석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1794-1796
    • /
    • 2000
  • Oxides of the form $Mn_{3}O_4$-$Co_{3}O_4$-NiO present properties that make them useful as multilayer chip NTC thermistor for mobile communication telephone. When $Mn_{2}Ni_{x}CO_{1-x}O_4$ composition with the X = 0.12$\sim$0.24 at sintered temperature 1250$^{\circ}C$, resistivity and B-constant were 300$\sim$450[${\Omega}-cm$] and 3250$\sim$3450, respectively. Multilayer chip NTC(Negative Temperature Coefficient) resistor were fabricated with 4 layer by a conventional multilayer capacitor techniques, using 100 pd paste as internal electrode and $Mn_{2}Ni_{0.20}CO_{0.8}O_4$ composition as NTC materials. In particular, resistance change ratio (${\Delta}R$), the important factor for reliability, varied within $\pm$3%, indicating the compositions of multilayer chip NTC thermistor products could be available for mobile communication telephone.

  • PDF

유한요소법을 이용한 유기압 현수장치의 열전달 해석 (Heat Transfer Analysis of Hydropneumatic Suspension Unit By Finite Element Method)

  • 배징도;조진래;이홍우;송정인;이진규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.531-536
    • /
    • 2004
  • In-arm type hydropeumatic suspension unit(ISU) is an equipment of armed tracked vehicle to absorb impact load and vibration from the irregular ground. During the operation of ISU, main piston moves forward and backward and oil flowing through damper transmits the external impact load to floating piston. Heat is generated in ISU by the oil pressure drop through the damper orifice and the friction between cylinder wall and two pistons. On the other hand, internal heat dissipatis outside via heat convection. Occurrence of high temperature can deteriorate durability of major components and basic function of ISU. And, it can cause fatal problem in the ISU life time and the sealing performance of piston rings. As well, the spring constant change of nitrogen gas that is caused by the temperature rise exerts the negative effect to the vehicle stability. Therefore, in this paper, we analyze the heat transfer analysis of the entire ISU unit, by finite element method, with the outside flow velocities 8m/s and 10m/s.

  • PDF

Glass Transition Temperature of Honey Using Modulated Differential Scanning Calorimetry (MDSC): Effect of Moisture Content

  • Kim, Mi-Jung;Yoo, Byoung-Seung
    • Preventive Nutrition and Food Science
    • /
    • 제15권4호
    • /
    • pp.356-359
    • /
    • 2010
  • Glass transition phenomena in nine Korean pure honeys (moisture content 18.3~20.1%) and honey-water mixtures by different water contents (0, 2, 5, and 10% w/w) were investigated with modulated different scanning calorimetry (MDSC). The total, reversing, and non-reversing heat flows were quantified during heating using MDSC. Glass transition was observed from reversing heat flow separated from the total heat flow. The glass transition temperatures ($T_g$) of pure honeys, which are in the range of $-42.7^{\circ}C$ to $-50.0^{\circ}C$, varied a lot with low determination coefficient ($R^2$=0.63), whereas those of honey-water mixtures decreased with a decrease in honey content. The $T_g$ values were also more significantly different among honey-water mixtures when compared to pure honeys, indicating that in the honey-water mixture system the $T_g$ values appear to be greatly dependent on moisture content. The measured heat capacity change (${\Delta}C_p$) was not influenced by moisture content.

태양광 발전시스템의 MPPT 알고리즘 분석 (Analysis of various MPPT algorithms for PCS)

  • 심재휘;양승대;정승환;최주엽;최익;안진웅;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.16-21
    • /
    • 2011
  • Since the maximum power operating point(MPOP) of PCS alters with changing atmospheric conditions temperature conditions shadow conditions it is important to operate for PCS to keep maximum power point tracking(MPPT) continuously. This paper presents the results of modeling PV system by PSIM simulator and investigates the influence on the PV system from aspect of power quality i.e. voltage drop. This paper investigates four MPPT algorithms; Perturbation & Observation(P&O) Improved P&O Incremental Conductance(Incond) Differential coefficient method simulated with irradiation temperature change and shadow conditions.

적외선 마이크로 볼로미터를 위한 $Si_{1-x}Sb_x$ 박막의 특성 (The characterization of the $Si_{1-x}Sb_x$ thin films for infrared microbolometer)

  • 이동근;류상욱;양우석;조성목;전상훈;류호준
    • 반도체디스플레이기술학회지
    • /
    • 제8권3호
    • /
    • pp.13-17
    • /
    • 2009
  • we have studied characterization of microbolometer based on the co-sputtered silicon-antimony ($Si_{1-x}Sb_x$) thin film for infrared microbolometer. We have investigated the resistivity and the temperature coefficient of resistance (TCR) with annealing. We deposited the films using co-sputtering method at $200^{\circ}C$ in the Ar environment. The Sb concentration has been adjusted by applying variable DC power from Sb targets. TCR of deposited $Si_{1-x}Sb_x$ films have been measured the range of -2.3~-2.8%/K. The resistivity of the film is low but TCR is higher than the other bolometer materials. Resistivity of the films has not been affected hugely according to the low annealing temperature however the resistivity has been dramatically decreased over $250^{\circ}C$. It is caused of a phase change due to the rearrangement of Si and Sb atoms during crystallization process of the films.

  • PDF

Balancing Well 교차혼합 지중열교환기의 스마트 냉난방 히트펌프 시스템의 성능평가에 관한 연구 (Study on the Performance Evaluation of Smart Heating and Cooling Heat Pump System in a Balancing Well Cross-Conditioned Ground Heat Exchanger)

  • 이창희;김동규;유병석;김부일
    • 신재생에너지
    • /
    • 제16권4호
    • /
    • pp.41-48
    • /
    • 2020
  • This study performed a single hole operation method using a balancing well-cross-mixed underground heat exchanger, and conducted thermal performance studies of an SCW-type underground heat exchanger using a two-well. The study attempted to change the existing operating method of the two adjacent SCW underground heat exchangers with one ball each. The SCW-type geothermal heat exchanger is considered to enable up to 20% of bleed discharge at maximum load, which makes groundwater usage unequal. The efficiency factor of the geothermal system was improved by constructing the discharged water by cross-mixing two balancing wells to prevent the discharge of groundwater sources and keep the temperature of the underground heat exchanger constant. As a result of the cooling and heating operation with the existing SCW heat exchange system and the balancing well-cross-mixed heat exchange system, the measured performance coefficient improved by 23% and 12% in cooling and heating operations, respectively. In addition, when operating with a balanced cross-mixing heat exchange system, it has been confirmed that the initial basement temperature is constant with a standard deviation of 0.08 to 0.12℃.

Epoxy 절연물의 내크랙성 향상에 관한 연구 (Study on Crack Resistance Improvement of Epoxy Insulation)

  • 하영길;김수연;이상진;김영성;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1581-1583
    • /
    • 1999
  • Epoxy Compound has been used as insulation material in cable accessories. During the applying voltage to cable, heat shock is induced to accessory by the temperature difference between atmosphere and conductor. In this study, crack resistance, thermal and mechanical properties were evaluated about conventional epoxy compound and rubber toughened epoxy compound. Because rubber absorbs the stress caused by heat shock, crack resistance of rubber toughened epoxy compound is high. In the case of low thermal expansion coefficient, the compound shows high crack resistance because of low volumetric change.

  • PDF

바나디움 주화물 반도체에 의한 발진현상에 관한 연구 (A Study on the Oscillation of Metal Vanadium Oxide Semiconductor)

  • 이종헌;홍창희;이화용
    • 대한전자공학회논문지
    • /
    • 제16권3호
    • /
    • pp.9-18
    • /
    • 1979
  • 본 논문에서는 바나디움 주화물을 사용한 새로운 반도체 소자인 C.T.R을 제조하여 그외 전기적 특성을 조사하였다. 그 실험결과는 다음과 같다. (1) 제조될 C.T.R의 저항급변계수 는 3정도였고, (2) 의 값은 환원시간과 급냉시간에 크게 의존하였으며, (3) 의 큰 값을 갖는 C.T.R은 짧은 switching현상을 갖는다.

  • PDF

로켓노즐내부의 공기 열역학적 삭마특성에 관한 연구 (A Study of Aero-thermodynamic Ablation Characteristics for Rocket Nozzle)

  • 서정일;정재헌;김영인;김정훈;송동주;배철호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.282-287
    • /
    • 2001
  • The CSCM Upwind method and Material Transport Analysis (MTA) have been used to predict the thermal response and ablation rate for non-charring material to be used as thermal protection material (TPM) in KSR-III test rocket nozzle. The thermal boundary conditions such as cold wall heat-transfer rate and recovery enthalpy for MTA code are obtained from the upwind Navier-Stokes solution procedure. The heat transfer rate and temperature variations at rocket nozzle wall were studied with shape change of the nozzle surface as time goes by. The surface recession was severely occurred at nozzle throat and this affected nozzle performance such as thrust coefficient substantially.

  • PDF

다공성 여재를 이용한 고정생물막 반응기 특성에 관한 연구 (The study on Fixed Bio-reactor Characteristics Using Porous Media)

  • 이영신;김동민;정상철;백명석
    • 한국환경보건학회지
    • /
    • 제22권1호
    • /
    • pp.99-106
    • /
    • 1996
  • The purpose of this study is to observe a specific removal efficiency of synthethetic wastewater which is managed by upflow submerged type at porous media which was sinteringed on a comparative low temperature 600$\circ$C, was annexed slag and humus soil with main material kaolinite. Observing removal efficiency quality of each media, a mixed media of kaolinite and humus soil by gravity percent 60, 40% respectively showed the most excellent removal utility, and applied predictive models for suspended culture kinetics without consideration diffusion limitation, and when analyzed kinetic which had been processed by this study the removal efficiency accompanied by carbon, nitrogen, phosphorous volumetric loading rate variation standed for a comparative large change rate 61~71%, it means the selection of the most proper load factor had a great effect on the highly removal efficiency, yield coefficient(Y) and specific microbial attach equation showed 1.53 mgVSS/mgCOD, $m_p=10039.4\times ((S_0)/(6.75+S_0))$ repectively.

  • PDF