• Title/Summary/Keyword: temperature change coefficient

Search Result 527, Processing Time 0.027 seconds

A Study on Heat Transfer Characteristics of Separate Type Heat Pipe with a Rotor (회전자를 갖는 분리형 히트파이프의 열전달특성에 관한 연구)

  • Jun, C.H.;Kim, O.G.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.75-84
    • /
    • 2000
  • The purpose of this research is to study on the heat transfer characteristics of separate type heat pipe with a rotor. The heat transfer characteristics of the rotor condenser are various on input heat of evaporator, rotational speeds of rotor, and working fluid amount. The results obtained from the study are as follows. 1. Magnetic fluid using seal of the rotor operated in stability by a variation of temperature and rotation speeds. The configuration of magnetic fluid seal assembly was adequate. 2. Steam ejector is effective in recovering working fluid condensate in the rotor. When steam ejector is operating, the heat flux of working fluid does not change, with the wall temperature in the rotor. 3. The optimum design conditions on working fluid amount and rotational speeds are effective in evaporator volume 50%, rotational speeds 200rpm, 300rpm, and operating temperature $80^{\circ}C$. With working fluid amount increasing, overall heat transfer coefficient decreases linearly.

  • PDF

Prediction of Depth of Concrete Carbonation According to Microenvironmental Conditions (미세 환경조건에 따른 콘크리트 탄산화 깊이 예측)

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.158-159
    • /
    • 2021
  • When the porous concrete is exposed to the external environment, the internal relative humidity changes from time to time due to the inflow and outflow of moisture. This change in moisture is affected by temperature. The temperature and humidity of concrete is dominant in the carbonation rate, the largest cause of deterioration of concrete. In this study, actual weather data were used as boundary conditions. A carbonization model of concrete temperature and humidity and calcium hydroxide was constructed to perform long-term analysis. There is a slight error in the carbonation formula of the Japanese Academy of Architecture applying the Kishtani coefficient, a representative experimental formula related to carbonization, and the analysis result values. However, considering that it behaves very similarly, it is thought that a fairly reliable numerical analysis model has been established. A slight error is believed to be due to the fact that the amount of residual calcium hydroxide in the carbonated site has not yet been clearly identified.

  • PDF

Basic Study for Development of Denitrogenation Process by Ion Exchange(III) - A kinetic study in the batch reactor - (이온교환법에 의한 탈질소 공정개발의 기초연구(III) - 회분식 반응기에서의 반응속도론-)

  • 채용곤;이동환;김승일;윤태경;홍성수;이민규
    • Journal of Environmental Science International
    • /
    • v.9 no.2
    • /
    • pp.165-171
    • /
    • 2000
  • A kinetic study for anion exchange was performed for commercially available Cl- type anion exchange resin in use to remove nitrate in water. The obtained results from the batch reactor were applied to the Langmuir and Freundlich models. The constants for Lagmuir model were qmax =29.82 and b=0.202, and for Freundlich model were K=5.509 and n=1.772. Langmuir model showed betterfit than Frendlich model for the experimental results. Ion exchange reaction rate was also calculated and the the approximate first-order reaction, rate constant k1 was 0.16 L/mg.hr. Effective diffusion coefficient was obtained in the range from $9.67$\times$10^{-8} cm^2/sec$ for initial concentration change, and from $6.09$\times$10^{-7} to 3.98$\times$10^{-6} cm^2/sec$ for reaction temperature change. Activation energy during the diffusion was calculated as 26 kcal/mol.

  • PDF

A Foundamental Study on the Solvent Dyeing Part 1. Change of PET Substrate Treated with Water, TCE and Water/TCE Emulsion. (용제염색에 관한 기초적 연구 제일보 물, TCE 및 물/TCE 처리에 의한 PET 기질의 변화)

  • Chung Doo Jin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.2 no.2
    • /
    • pp.245-252
    • /
    • 1978
  • In order to obtain some information for solvent dyeing, polyethylene terephthalate (PET) was treated with water, tetrachloroethylene yarn (TCE), and water/TCE emulsion for three hours at the temperatures from $40^{\circ}$ to $140^{\circ}C$. The change of fine structure of substratum by measuring the shrinkage, the degree of crystallinity, the stress relacxation modulus and Young's modulus. The P.E.T. film was also treated in water (at $140^{\circ}C$) for 4 hours to stabilize the substratum. By means of film roll cyliderical method, the Disperse Blue 27 was diffused. Then, calculated the diffusion coefficient and examined the application of WLF equation. However, the temperature dependence of the shrinkage could be explain with WLF equation, the diffusion coefficient couldn't be applied the WLF equation when the substratum was stabilized. From the result, the effects on shrinkage were in the order of water

  • PDF

Comparison of the effects of irradiation on iso-molded, fine grain nuclear graphites: ETU-10, IG-110 and NBG-25

  • Chi, Se-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2359-2366
    • /
    • 2022
  • Selecting graphite grades with superior irradiation characteristics is important task for designers of graphite moderation reactors. To provide reference information and data for graphite selection, the effects of irradiation on three fine-grained, iso-molded nuclear grade graphites, ETU-10, IG-110, and NBG-25, were compared based on irradiation-induced changes in volume, thermal conductivity, dynamic Young's modulus, and coefficient of thermal expansion. Data employed in this study were obtained from reported irradiation test results in the high flux isotope reactor (HFIR)(ORNL) (ETU-10, IG-110) and high flux reactor (HFR)(NRL) (IG-110, NBG-25). Comparisons were made based on the irradiation dose and irradiation temperature. Overall, the three grades showed similar irradiation-induced property change behaviors, which followed the historic data. More or less grade-sensitive behaviors were observed for the changes in volume and thermal conductivity, and, in contrast, grade-insensitive behaviors were observed for dynamic Young's modulus and coefficient of thermal expansion changes. The ETU-10 of the smallest grain size appeared to show a relatively smaller VC to IG-110 and NBG-25. Drastic decrease in the difference in thermal conductivity was observed for ETU-10 and IG-110 after irradiation. The similar irradiation-induced properties changing behaviors observed in this study especially in the DYM and CTE may be attributed to the assumed similar microstructures that evolved from the similar size coke particles and the same forming method.

Correlation Analysis of Atmospheric Pollutants and Meteorological Factors Based on Environmental Big Data

  • Chao, Chen;Min, Byung-Won
    • International Journal of Contents
    • /
    • v.18 no.1
    • /
    • pp.17-26
    • /
    • 2022
  • With the acceleration of urbanization and industrialization, air pollution has become increasingly serious, and the pollution control situation is not optimistic. Climate change has become a major global challenge faced by mankind. To actively respond to climate change, China has proposed carbon peak and carbon neutral goals. However, atmospheric pollutants and meteorological factors that affect air quality are complex and changeable, and the complex relationship and correlation between them must be further clarified. This paper uses China's 2013-2018 high-resolution air pollution reanalysis open data set, as well as statistical methods of the Pearson Correlation Coefficient (PCC) to calculate and visualize the design and analysis of environmental monitoring big data, which is intuitive and it quickly demonstrated the correlation between pollutants and meteorological factors in the temporal and spatial sequence, and provided convenience for environmental management departments to use air quality routine monitoring data to enable dynamic decision-making, and promote global climate governance. The experimental results show that, apart from ozone, which is negatively correlated, the other pollutants are positively correlated; meteorological factors have a greater impact on pollutants, temperature and pollutants are negatively correlated, air pressure is positively correlated, and the correlation between humidity is insignificant. The wind speed has a significant negative correlation with the six pollutants, which has a greater impact on the diffusion of pollutants.

Vertical Variations Analysis of Air Temperature and CO2 Concentration in the Grassplots (잔디밭에서 기온과 이산화탄소 농도의 연직 변동 분석)

  • So, Yoon Hwan;Kang, Dong Hwan;Kim, Il Kyu;Kim, Byung Woo;Yoon, Hwan Jin;Kim, Si Hyeon;Son, Yong Seok;Shin, Jung Hyeon;Ahn, Jeong Woo
    • Journal of Environmental Science International
    • /
    • v.26 no.2
    • /
    • pp.147-157
    • /
    • 2017
  • This study investigated the characteristics of variations in carbon dioxide concentration and air temperature with the vertical change of surface in a grassplot. Field observations were carried out at a grassplot in Gyeongnam Science High School, over four days in August and November, 2015. Continuous observation equipment (GMP343, VAISALA) was installed at the LP (0.1 m from the surface) and UP (1.1 m from the surface) points, and the carbon dioxide concentration and air temperature were measured simultaneously at 1-min intervals. To summarize the results of the observation, August had higher than average concentrations of carbon dioxide, while November showed average air temperatures. Moreover, the concentration of carbon dioxide was higher at the UP point, while the air temperature was higher at the LP point. The correlation coefficient of carbon dioxide concentration between the UP and LP points was 0.80 in August across all the four days, while it was higher in November at 0.58-0.95. The results of the regression analysis of carbon dioxide concentration with air temperature changes for both August and November showed a distinct change at the LP point (R2=0.36-0.76), as compared to the UP point (R2=0.1-0.57). Between the UP and LP points, the carbon dioxide concentration and air temperature regression analysis results indicated that an active exchange was taking place between the two points.

Thermal post-buckling analysis of functionally graded beams with temperature-dependent physical properties

  • Kocaturk, Turgut;Akbas, Seref Doguscan
    • Steel and Composite Structures
    • /
    • v.15 no.5
    • /
    • pp.481-505
    • /
    • 2013
  • This paper focuses on thermal post-buckling analysis of functionally graded beams with temperature dependent physical properties by using the total Lagrangian Timoshenko beam element approximation. Material properties of the beam change in the thickness direction according to a power-law function. The beam is clamped at both ends. In the case of beams with immovable ends, temperature rise causes compressible forces and therefore buckling and post-buckling phenomena occurs. It is known that post-buckling problems are geometrically nonlinear problems. Also, the material properties (Young's modulus, coefficient of thermal expansion, yield stress) are temperature dependent: That is the coefficients of the governing equations are not constant in this study. This situation suggests the physical nonlinearity of the problem. Hence, the considered problem is both geometrically and physically nonlinear. The considered highly non-linear problem is solved considering full geometric non-linearity by using incremental displacement-based finite element method in conjunction with Newton-Raphson iteration method. In this study, the differences between temperature dependent and independent physical properties are investigated for functionally graded beams in detail in post-buckling case. With the effects of material gradient property and thermal load, the relationships between deflections, critical buckling temperature and maximum stresses of the beams are illustrated in detail in post-buckling case.

A Study on the Estimation of Temperature Dependance in Tissue by Ultrasound (초음파에 의한 조직의 온도의존성에 관한 연구)

  • 이상민;박형배
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.165-172
    • /
    • 1989
  • In this paper, the temperature dependence of tissue is estimated by measuring the attenuation coefficient and the propagation velocity of ultrasonic reflection signal. And, on the basis of expeiments, the possibility of non- invasive temperature estimation is considered. Specimens in the experiment are acryl 1)late. muscle, fat and liver of pig. The temperature of specimen is controlled by water bath which is able to adjust temperature a quarter of a degree. Through the series of experiments, we conformed that the ultrasonic parameters have lin earity to a certain extents with the change of tissue's temperature. And we expect that noninvasive temperature estimation of tissue can be realized after several preconditions be satisfied with the standard experiment conditions and a great number of base data.

  • PDF

Real Effect of pH on CIE L*, a*, and b*, of Loins during 24 h Chilling of Beef Carcasses

  • Min, J.S.;Kim, I.S.;Yoon, Y.T.;Lee, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.2
    • /
    • pp.279-282
    • /
    • 2002
  • Twenty six male Hanwoo (Korean cattle) carcasses were measured for pH, temperature and instrumental color changes of loins during 24 h post-mortem carcass chilling at $4^{\circ}C$ in the cooler. The average internal temperature of loins was about $5^{\circ}C$ after 24 h of chilling, and with the exclusion of those with an ultimate pH>6.0 (dark-cutters), the average pH value was 5.5. When all carcasses were considered for the partial correlation coefficient between color and pH, with the temperature effect excluded, CIE $L^*$, $a^*$ and $b^*$ seemed to be affected significantly by pH during chilling process (p<0.001). However, when carcasses with dark-cutting condition were excluded, the correlation coefficients were much lower. In contrast, when the partial correlation coefficients between color and temperature, excluding the effect of pH on them, were analyzed, the relationship between color and temperature did not change much after values of DFD (dark, firm, dry) beef were excluded. The results suggested that the known interrelationship of color and pH in chilled beef loins be mainly due to the influence of temperature on pH and color.