• Title/Summary/Keyword: temperature calibration

Search Result 516, Processing Time 0.027 seconds

Estimation of shelf-life by long-term storage test of Pyungwi-san (평위산 전탕팩의 장기보존 시험에 따른 유통기한 설정)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Lim, Soon-Hee;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.19 no.1
    • /
    • pp.183-194
    • /
    • 2011
  • Objectives : To estimate the shelf-life by long-term storage test of Pyungwi-san. Methods : Experiments were conducted to evaluate the stability such as the selected physicochemical, heavy metal, microbilogical experiment under an acceleration test and long-term storage test of Pyungwi-san in different storage under room temperature, refrigeration and freezing. Futhermore, HPLC analysis was performed for the determinations of glycyrrhizin in the Pyungwi-san on an Inertsil ODS-3 column(250 mm ${\times}$ 4.6 mm, 5 um) using solvent 35% acetonitrile include 0.05% phosphoric acid at 254 nm. The flow rate was 1.0 mL/min. Results : The significant change was not showed in pH, heavy metal, microbiological, identification test and quantitative analysis based on acceleration test and long-term storage test. Retention time of glycyrrhizin in HPLC chromatogram was about 16.065 min and calibration curve showed good linearity($R^2$ = 0.9999). The contents of glycyrrhizin in acceleration test and long-term storage test were 0.068~0.076 mg/mL and 0.066~0.077 mg/mL, respectively. Shelf-lifes of room temperature, refrigeration and freezing by long-term storage test were predicted 41, 24 and 34 months, respectively. Conclusions : The suggested shelf-life would be helpful on the storage and distribution of herbal medicine.

Determination of Non-Steroidal Anti-Inflammatory Drugs in Human Urine Sample using HPLC/UV and Three Phase Hollow Fiber-Liquid Phase Microextraction (HF-LPME)

  • Cha, Yong Byoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3444-3450
    • /
    • 2013
  • Three phase hollow fiber-liquid phase microextraction (HF-LPME), which is faster, simpler and uses a more environmentally friendly sample-preparation technique, was developed for the analysis of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) in human urine. For the effective simultaneous extraction/concentration of NSAIDs by three phase HF-LPME, parameters (such as extraction organic solvent, pH of donor/acceptor phase, stirring speed, salting-out effect, sample temperature, and extraction time) which influence the extraction efficiency were optimized. NSAIDs were extracted and concentrated from 4 mL of aqueous solution at pH 3 (donor phase) into dihexyl ether immobilized in the wall pores of a porous hollow fiber, and then extracted into the acceptor phase at pH 13 located in the lumen of the hollow fiber. After the extraction, 5 ${\mu}L$ of the acceptor phase was directly injected into the HPLC/UV system. Simultaneous chromatographic separation of seven NSAIDs was achieved on an Eclipse XDB-C18 (4.6 mm i.d. ${\times}$ 150 mm length, 5 ${\mu}m$ particle size) column using isocratic elution with 0.1% formic acid and methanol (30:70) at a HPLC-UV/Vis system. Under optimized conditions (extraction solvent, dihexyl ether; $pH_{donor}$, 3; $pH_{acceptor}$, 13; stirring speed, 1500 rpm; NaCl salt, 10%; sample temperature, $60^{\circ}C$; and extraction time, 45 min), enrichment factors (EF) were between 59 and 260. The limit of detection (LOD) and limit of quantitation (LOQ) in the spiked urine matrix were in the concentration range of 5-15 ng/mL and 15-45 ng/mL, respectively. The relative recovery and precision obtained were between 58 and 136% and below 15.7% RSD, respectively. The calibration curve was linear within the range of 0.015-0.96 ng/mL with the square of the correlation coefficient being more than 0.997. The established method can be used to analyse of NSAIDs of low concentration (ng/mL) in urine.

Direct Determination Method of Antimony in High Purity Copper Metal by Graphite Furnace Atomic Absorption Spectrometry (흑연로 원자 흡수흡광법에 의한 고순도 구리 합금중의 안티몬의 직접 분석 방법)

  • Yoo, K.S;Kyung, J.D;Kwon, J.G;Lee, J.J
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.4
    • /
    • pp.252-256
    • /
    • 1995
  • A study was carried out for the development of direct determination of antimony in high purity copper metal without preseparation. The large excess of copper seemed to be performed as the matrix modifier to enhance the absorbance of antimony in copper metal. Sensitivity enhancement of Sb was obtained at the condition of the ashing temperature of $600^{\circ}C(20s){\sim}700^{\circ}C(10s)$ rather than $1000^{\circ}C(20s){\sim}1100^{\circ}C(10s)$, and the atomization temperature of $2200^{\circ}C.$ The operating pressure of argon gas was readjusted to the optimum condition at 2.0 kg/$cm^2.$ The linearity of the Sb calibration graph could be obtained in the range of 20 ppb up to 200 ppb Sb in existence of 5,000 ppm Cu with the coefficient of variation of about 5%.

  • PDF

Reliability Evaluation of Fiber Optic Sensors Exposed to Cyclic Thermal Load (주기적인 반복 열하중에 노출된 광섬유 센서의 신뢰성 평가)

  • Kim, Heon-Young;Kang, Donghoon;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.225-230
    • /
    • 2016
  • Fiber Bragg grating (FBG) sensors are currently the most prevalent sensors because of their unique advantages such as ease of multiplexing and capability of performing absolute measurements. They are applied to various structures for structural health monitoring (SHM). The signal characteristics of FBG sensors under thermal loading should be investigated to enhance the reliability of these sensors, because they are exposed to certain cyclic thermal loads due to temperature changes resulting from change of seasons, when they are applied to structures for SHM. In this study, tests on specimens are conducted in a thermal chamber with temperature changes from -$20^{\circ}C$ to $60^{\circ}C$ for 300 cycles. For the specimens, two types of base materials and adhesives that are normally used in the manufacture of packaged FBG sensors are selected. From the test results, it is confirmed that the FBG sensors undergo some degree of compressive strain under cyclic thermal load; this can lead to measurement errors. Hence, a pre-calibration is necessary before applying these sensors to structures for long-term SHM.

Development of relative radiometric calibration system for in-situ measurement spectroradiometers (현장관측용 분광 광도계의 상대 검교정 시스템 개발)

  • Oh, Eunsong;Ahn, Ki-Beom;Kang, Hyukmo;Cho, Seong-Ick;Park, Young-Je
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.4
    • /
    • pp.455-464
    • /
    • 2014
  • After launching the Geostationary Ocean Color Imager (GOCI) on June 2010, field campaigns were performed routinely around Korean peninsula to collect in-situ data for calibration and validation. Key measurements in the campaigns are radiometric ones with field radiometers such as Analytical Spectral Devices FieldSpec3 or TriOS RAMSES. The field radiometers must be regularly calibrated. We, in the paper, introduce the optical laboratory built in KOSC and the relative calibration method for in-situ measurement spectroradiometer. The laboratory is equipped with a 20-inch integrating sphere (USS-2000S, LabSphere) in 98% uniformity, a reference spectrometer (MCPD9800, Photal) covering wavelengths from 360 nm to 1100 nm with 1.6 nm spectral resolution, and an optical table ($3600{\times}1500{\times}800mm^3$) having a flatness of ${\pm}0.1mm$. Under constant temperature and humidity maintainance in the room, the reference spectrometer and the in-situ measurement instrument are checked with the same light source in the same distance. From the test of FieldSpec3, we figured out a slight difference among in-situ instruments in blue band range, and also confirmed the sensor spectral performance was changed about 4.41% during 1 year. These results show that the regular calibrations are needed to maintain the field measurement accuracy and thus GOCI data reliability.

Application of Remote Sensing Technique to Enhance the Water Quality Model Validation in a Large Water Body (원격탐사를 이용한 대형 수체의 수질 모델 검증 효과 제고 방안에 관한 연구)

  • Lim, Hyun-Ju;Choi, Jung-Hyun;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.447-452
    • /
    • 2006
  • The remote sensing technique was applied to enhance the water qualify model validation in a large water body. Since the satellite image usually covers the wide surface area of a large water body, it can compensate for the lark of measured data points required for model calibration and verification. This paper describes the analysis of Landsat FTM+images collected on April 29th and September 4th in year 2000 to evaluate surface water temperature of Lake Paldang. The water temperature data obtained from the satellite image were compared with model results by estimating three different methods of error criteria. The residual ratios on April 29th and September 4th were 0.13 and 0.04 respectively. This showed that the model result accords with the data obtained from the process of satellite image. Without considering atmospheric interference, however, transformation process of satellite image causes relatively large residual ratio in the surface water temperature distribution pattern on April 29th. In the future study, therefore, the atmospheric properties of image acquisition point needs to be considered for the application of radiance transformation model.

Matrix Modification for Atomic Absorption Spectrophotometric Determination of Volatile Elements (Ⅱ). Determination of Trace Germanium by Electrothermal Atomization (휘발성 원소들의 원자흡수 분광분석을 위한 매트릭스 개선에 관한 연구(제2보). 전열 원자화에 의한 흔적량 게르마늄의 정량)

  • Choi, Ho Sung;Choi, Jong Moon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.2
    • /
    • pp.109-116
    • /
    • 1996
  • A matrix modification was studied for the determination of trace germanium in mineral waters by electrothermal atomic absorption spectrophotometry (ET-AAS). For this, the type and quantity of modifier as well as the use of auxiliary modifier were investigated to realize the efficient modification. Germanium suffers from low sensitivity and poor reproducibility in ET-AAS determination because of the premature loss of germanium via volatile germanium monoxide formation when heated in the presence of carbon. Therefore, the addition of a matrix modifier is necessary to stablize the germanium, thermally and chemically. By the addition of palladium (10 ${\mu}g/mL)$ as a single modifier to the sample containing 500 ng/mL germanium, the charring temperature could be raised from 800 to $1000^{\circ}C$, and its absorbance was also increased, but the atomization temperature was not raised. In this case, the absorbance of germanium was not changed in the range of 10∼70 ${\mu}g/mL$ of palladium added. On the other hand, it was considered that the use of a mixed modifier could modifiy the matrix more effectively than with a single modifier. The best results were obtained by using 1% ammonium hydroxide as an auxiliary modifier together with 10 ${\mu}g/mL$ palladium. The charring temperature could be raised from 800 to $1100^{\circ}C$, without any change of the atomization temperature. With above optimum conditions, the trace amount of germanium in several mineral waters were determined by a calibration curve method, and good recoveries of more than 95% were also obtained in the samples in which a given amount of germanium was spiked. The detection limit of this method was about 6.9 ng/mL.

  • PDF

Evaluation of SWAT Applicability to Simulate Soil Erosion at Highland Agricultural Lands (고랭지 농경지의 토양유실모의를 위한 SWAT 모형의 적용성 평가)

  • Heo, Sung-Gu;Kim, Ki-Sung;Sa, Gong-Myong;Ahn, Jce-Hun;Lim, Kyoung-Jae
    • Journal of Korean Society of Rural Planning
    • /
    • v.11 no.4 s.29
    • /
    • pp.67-74
    • /
    • 2005
  • The Doam watershed is located at alpine areas and the annual average precipitation, including snow accumulation, is significant higher than other areas. Thus, pollutant laden runoff and sediment discharge from the alpine agricultural fields are causing water quality degradation at the Doam watershed. To estimate soil erosion from the agricultural fields, the Universal Soil Loss Equation (USLE) has been widely used because of its simplicity to use. In the early spring at the Doam watershed, the stream flow increases because of snow melt, which results in erosion of loosened soil experiencing freezing and thaw during the winter. Also, extremely torrential rainfall, such as the typhoons 'RUSA' in 2002 and 'MAEMI' in 2003, caused significant amounts of soil erosion and sediment at the Doam watershed. However, the USLE model cannot simulate impacts on soil erosion of freezing and thaw of the soil. It cannot estimate sediment yield from a single torrential rainfall event. Also, it cannot simulate temporal changes in USLE input parameters. Thus, the Soil and Water Assessment Tool (SWAT) model was investigated for its applicability to estimate soil erosion at the Doam watershed, instead of the widely used USLE model. The SWAT hydrology and erosion/sediment components were validated after calibration of the hydrologic component. The R$^2$ and Nash-Sutcliffe coefficient values are higher enough, thus it is found the SWAT model can be efficiently used to simulate hydrology and sediment yield at the Doam watershed. The effects of snow melt on SWAT estimated stream flow and sediment were investigated using long-term precipitation and temperature data at the Doam watershed. It was found significant amount of flow and sediment in the spring are contributed by melting snow accumulated during the winter. Two typhoons in 2002 and 2003, MAEMI and RUSA, caused 33% and 22% of total sediment yields at the Doam watershed, respectively. Thus, it is recommended that the SWAT model, capable of simulating snow melt, sediment yield from a single storm event, and long-term weather data, needs to be used in estimating soil erosion at alpine agricultural areas to develop successful soil erosion management instead of the USLE.

Air Density Correction of Ionization Chamber using $^{90}Sr$ Radioactive Check Device ($^{90}Sr$ 방사성 동위원소를 이용한 전리함의 대기 보정계수 측정)

  • Park, Sung-Y.;Kim, Woo-C.;Shin, Dong-O.;Ji, Young-H.;Kwon, Soo-I.;Lee, Kil-D.;Cho, Young-K.;Loh, John-J.
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.267-271
    • /
    • 1998
  • It is required to measure air density correction factor at the time of absorbed dose calibration or measurement. In general, thermometer and barometer are widely used for air density correction. However, this can be done using the radioactive check device with better accuracy. The measurements of air density correction were performed by using the radioactive check device, Unidos electrometer, and 0.6 cc Farmer-type ion chamber of PTW under the different environmental conditions. Above experiments were repeated with thermometer and barometer. By comparing the two methods, they were within the difference of 0.2 %. The overall uncertainty for the dose found in thermometer and barometer was 1.2 - 1.6 %, depending upon either one step or two, whereas the overall uncertainty for the radioactive check device was 1.02 %. This method may reduce the possible error which could occur when thermometer and barometer are not calibrated at regular basis.

  • PDF

DEVELOPMENT OF A FLUXGATE MAGNETOMETER FOR THE KITSAT-3 SATELLITE (과학위성용 자력계 탑재체 개발에 관한 연구)

  • ;;;;;;Onishi Nobugito
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.2
    • /
    • pp.312-319
    • /
    • 1997
  • The magnetometer is one of the most important payloads for scientific satellite to monitor the near-earth space environment. The electromagnetic variations of the space environment can be observed with the electric and magnetic field measurements. In practice, it is well known that the measurement of magnetic fields needs less technical complexities than that of electric fields in space. Therefore the magnetometer has long been recognized as one of the basic payloads for the scientific satellites. In this paper, we discuss the scientific fluxgate magnetometer which will be on board the KITSAT-3. The main circuit design of the present magnetometer is based on that of KITSAT-1 and -2 but its facilities have been re-designed to improve the resolution to about 5nT for scientific purpose. The calibration and noise level test of this circuit have been performed at the laboratory of the Tierra Tecnica company in Japan.

  • PDF