• 제목/요약/키워드: temperature calibration

검색결과 516건 처리시간 0.029초

스파크점화기관에서 고속응답 FID를 이용한 실린더내 잔류가스량 측정에 관한 연구 (A Study for Measurements of In-Cylinder Residual Gas Fraction using Fast Response FID in an SI Engine)

  • 송해박;조한승;이종화;이귀영
    • 한국자동차공학회논문집
    • /
    • 제6권1호
    • /
    • pp.80-89
    • /
    • 1998
  • The residual gas in an spark-ignition engine is one of important factors on emissions and performance such as combustion stability. With high residual gas fractions, flame speed and maximum combustion temperature are decreased and these are deeply related with combustion stability especially at idle and NOx emission at relatively high engine load. Therefore, there is a need to characterize the residual gas fraction as a function of the engine operating load. Therefore, there is a need to characterize the residual gas fraction as a function of the engine operating parameters. In the present study, the quantitative measurement technique of residual gas fraction was studied by using Fast Response Flame Ionization Detector(FRFID). The measuring technique and model for estimation of residual gas fraction were reported in this paper. By the assuming that the raw signal from FRFID saturates with the same slope for firing and misfiring cycle, in-cylinder hydrocarbon(HC) concentration can be estimated. Residual gas fraction can be obtained from the in-cylinder HC concentration measured at firing and motoring condition. The developed measurement and calibration procedure were applied to the limited engine operating and design condition such as intake manifold pressure and valve overlap. The results show relevant trends by comparing those from previous studies.

  • PDF

TL 연대측정법을 이용한 토기 시편의 선량 분석 (A Study on the Dose Analysis of Pottery Shards by Thermoluminescence Dating Method)

  • 신현상
    • 분석과학
    • /
    • 제12권6호
    • /
    • pp.558-564
    • /
    • 1999
  • TL 연대측정법을 이용하여 백제 토기 시편의 고고학적 선량 분석방법을 확립하였다. TL 측정을 위한 시료는 토기 시편으로부터 $90{\sim}125{\mu}m$ 크기의 석영 결정만을 분리하여 준비하였다. TL 측정을 통하여 얻어진 글로우 곡선에 대한 plateau 평가 결과 $265{\sim}300^{\circ}C$ 영역에서 비정상적인 fading이 없는 안정된 TL이 방출됨을 확인하였다. 토기 시료에 축적된 자연 TL량과 감마선원인 $^{137}Cs$을 인위적으로 조사하여 얻어진 선량에 따른 TL량의 외삽을 통하여 시편의 선량을 결정하였다. 그 결과 백제 토기 시편에 축적된 고고학적 선량은 7.43 Gy이었다.

  • PDF

마이크로웨이브를 이용한 콘크리트 잔골재 표면수율 측정 자동화 (Microwave Moisture Measurement of Fine Aggregate in RMC Industry)

  • 최영철;이봉춘;문규돈;손영정
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.63-69
    • /
    • 2012
  • Ready-mixed concrete(RMC) has been a major construction materials for infrastructures. However, RMC with poor quality is reported to be social issue since it directly user's safety and convenience. Because the properties of concrete as a construction material are greatly influenced by the variation of water content, to control water accurately is the most efficient method for the quality control in RMC industry. In this study, the automatic measurement technology of fine aggregate was developed by using the microwave moisture measurement. For the various conditions of fine aggregate such as moisture, temperature and pressure, the calibration curve of moisture measurement was obtained by using oven-dry method. From the infield and outfield test, it can be obtained that the accuracy of microwave moisture measurement is very high and the automatic system of microwave moisture measurement is very convenient and useful for quality control in RMC Industry.

GC/FPD에 의한 천연가스 중 황 함유 부취제의 정량 (Determination of Sulfur-Containing Odorants in Natural Gas by Gas Chromatography/Flame Photometric Detection)

  • 최용욱;김종훈;최건형;신성식
    • 분석과학
    • /
    • 제7권3호
    • /
    • pp.349-359
    • /
    • 1994
  • 천연가스 중의 부취제 농도를 분석하기 위한 기체 크로마토그래피 방법에 대하여 연구하였다. TBM(tertiarybutylmercaptan) 및 THT(tetrahydrothiophene)를 포함한 8종의 부취제를 OV-101 컬럼상에서 거의 완전히 분리하였다. 수소 유속, 공기 유속 및 검출기 온도와 같이 FPD의 응답에 영향을 미치는 몇 가지 상호 관련된 파라미터들의 최적 조건을 구하였다. TBM과 THT의 검정곡선을 투과한 장치를 이용하여 작성하였다. 이러한 분석방법을 천연가스 공급관 내의 혼합 부취제인 TBM과 THT를 정량하는 데 적용하였다. 부취수준과 부취제 농도와의 상관관계를 구하기 위한 냄새 측정기의 유용성에 대하여 알아보았다.

  • PDF

3단형 과학로켓용 과학탑재체 개발 (Development of Scientific Payloads for Korea Sounding Rocket-III)

  • 황승현;김준;이수진;전영두;박정주
    • 한국항공우주학회지
    • /
    • 제31권2호
    • /
    • pp.80-88
    • /
    • 2003
  • 본 논문은 KSR-III 과학로켓에 탑재 가능한 과학탑재체 중 오존측정기와 이온층 전자측정기 개발에 관하여 기술하고 있다. 각각의 측정기는 센서부와 회로부로 구성되며 개발 완료된 모델로 오존측정기는 지상 보정실험을 , 그리고 전자측정기는 우주환경 모사실험을 성공적으로 수행하였다. 이렇게 개발된 탑재체들은 향후 KSR-III 등의 과학로켓에 탑재될 수 있으며, 한반도 상공의 오존층 밀도의 고도별 수직분포와 이온층의 전자밀도와 전자온도에 대한 고도별 수직분포를 연구하는데 크게 기여할 것이다.

유공압 부품이 내장된 인쇄회로기판을 활용한 내시경 수술용 기복기의 개발 (Development of the Insufflator for Endoscopic Surgery using the Fluidic System in Printed Circuit Board)

  • 이희남;김인영;지영준
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권1호
    • /
    • pp.32-36
    • /
    • 2011
  • The insufflators in endoscopic surgery supply carbon dioxide to make the air-filled cavity in the abdomen. It contains many kinds of pneumatic and electronic parts and they are connected with the air tubes and electrical wires. The printed circuit boards (PCB) perform wiring, holding and cooling tasks in electronic systems. In this study, the PCB is used as the air channel for insufflators to decrease the cost, volume, and the malfunction according to aging of the device. Three layers of PCB made of FR4 are combined with prepreg as adhesive which has the internal airway channel according to the design. By mounting the pressure sensors and valves, the PCB based fluidic system is implemented. After calibration of flow sensor, the flow rate of the gas also can be measured. The climate test, temperature test, and biocompatibility test showed this idea can be used in insufflators for laparoscopic surgery.

Application of KOMPSAT/OSMI Data for Fisheries Oceanography in the East China Sea

  • Suh Young-Sang;Jang Lee-Hyun;Lee Na-Kyung;Kim Yong-Seung;Lee Sun-Gu;Yoo Hong-Rhyong
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.557-561
    • /
    • 2004
  • A comparison was made between chlorophyll a from OSMI and SeaWiFS determined with the standard method during the NFRDI's research cruises. The simple algorithm for calibrating and validating of OSMI chlorophyll a as level 2 data in the East China Sea in specially winter season was made by relationship between the estimated chlorophyll a and the measured chlorophyll a in the field. We compared the distributions of OSMI chlorophyll a, sea surface temperature and zooplankton biomass, catch amounts of the Pacific mackerel in the East China Sea.

  • PDF

스마트한 상황인지를 적용한 도플러 레이더 센서 기반의 정밀 위치추정 시스템 (A Precise Location Tracking System with Smart Context-Awareness Based-on Doppler Radar Sensors)

  • 문승진;김홍규
    • 제어로봇시스템학회논문지
    • /
    • 제16권12호
    • /
    • pp.1159-1166
    • /
    • 2010
  • Today, detecting the location of moving object has been traced as various methods in our world. In this paper, we preset the system to improve the estimation accuracy utilizing detail localization using radar sensor based on WSN and situational awareness for a calibration (context aware) database, Rail concept. A variety of existing location tracking method has a problem with receiving of data and accuracy as tracking methodology, and since these located data are the only data to be collected for location tracing, the context aware or monitering as the surrounding environment is limited. So, in this paper, we enhanced the distance aware accuracy using radar sensor utilizing the Doppler effect among the distance measuring method, estimated the location using the Triangulation algorithm. Also, since we composed the environment data(temperature, illuminancem, humidity, noise) to entry of the database, it can be utilized in location-based service according to the later action information inference and positive context decision. In order to verify the validity of the suggested method, we give a few random situation and built test bed of designed node, and over the various test we proved the utilizing the context information through route tracking of moving and data processing.

Development of accuracy enhancement system for boron meters using multisensitive detector for reactor safety

  • Sung, Si Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.538-543
    • /
    • 2020
  • Boric acid is used as a coolant for pressurized-water reactors, and the degree of burnup is controlled by the concentration of boric acid. Therefore, accurate measurement of the concentration of boric acid is an important factor in reactor safety. An improved system was proposed for the accurate determination of boron concentration. A new boron-concentration measurement technique, called multisensitive detection, was developed to improve the measurement accuracy of boron meters. In previous studies, laboratory-scale experiments were performed based on different sensitivity detectors, confirming a 65% better accuracy than conventional single-detector boron meters. Based on these experimental results, an experimental system simulating the coolant-circulation environment in the reactor was constructed; accuracy analysis of the boron meter with a multisensitivity detector was performed at the actual coolant pressure and temperature. In this study, the boron concentration conversion equation was derived from the calibration test, and the accuracy of the boron concentration conversion equation was examined through a repeatability test. Through the experiment, it was confirmed that the accuracy was up to 87.5% higher than the conventional single-detector boron meter.

Determination of Palladium in Water Samples Using Cloud Point Extraction Coupled with Laser Thermal Lens Spectrometry

  • Han, Quan;Huo, Yanyan;Yang, Na;Yang, Xiaohui;Zhai, Yunhui;Zhang, Qianyun
    • 대한화학회지
    • /
    • 제59권5호
    • /
    • pp.407-412
    • /
    • 2015
  • A preconcentration procedure for determination of palladium by laser thermal lens spectrometry (TLS) is proposed. It is based on cloud point extraction of palladium(II) ions as 2-(3,5-dichloro-2-pyridylazo)-5-dimethylaminoaniline (3,5-diCl-PADMA) complexes using octylphenoxypolyethoxyethanol (Triton X-114) as surfactant. The effects of various experimental conditions such as pH, concentration of ligand and surfactant, equilibration temperature and time on cloud point extraction were studied. Under the optimized conditions, the calibration graph was linear in the range of 0.15~6 ng mL−1, and the detection limit was 0.04 ng mL−1 with an enrichment factor of 22. The sensitivity was enhanced by 846 times when compared with the conventional spectrophotometric method. The recovery of palladium was in the range of 96.6%~104.0%. The proposed method was applied to the determination of palladium in water samples.