• Title/Summary/Keyword: temperature calibration

Search Result 516, Processing Time 0.035 seconds

Flow Control of a Solenoid Gas Injector and Its Application on a Natural Gas Engine (솔레노이드 가스 인젝터의 유량제어와 천연가스엔진에서의 응용)

  • Sim, Han-Sub
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.2
    • /
    • pp.83-89
    • /
    • 2009
  • An air-fuel ratio control is essential in reducing hazardous exhaust emissions from a compressed natural gas(CNG) engine, and can be accomplished by accurate control of gas injection flow. In this study, theoretical research was conducted on injection characteristics of a solenoid gas injector, and injection experiments for calibration and analysis were performed. Various factors for gas injection flow such as injection pressure, gas temperature, and supply voltage are studied. A dynamic flow equation of the natural gas was proposed on the basis of flow dynamics theories and results of the injection experiment. The verification of the dynamic flow equation of the solenoid injector was carried out with a large CNG-engine applied to an urban bus. Air-fuel ratio control experiments were conducted in both steady and transient state. Results of injection experiments for the solenoid injector and the CNG-engine was proved the control method proposed herein to be effective.

  • PDF

Long Term Stability of Uncertainty Analysis of Light Oil Elow Standard System (장기 안정성을 고려한 경질유 유량표준장치 불확도 평가)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.10 s.241
    • /
    • pp.1130-1138
    • /
    • 2005
  • A national standard system for the petroleum field has been developed to calibrate and test the oil flow meters in Korea. The operating system and the uncertainty of the system were evaluated by the peer reviewers of foreign national metrology institutes in 2002. Since the characteristics of the system might be changed by time, the uncertainty of the system is reevaluated with the consideration of the long term stability of the system. It is found that the system has a relative expanded uncertainty of 0.048 $\%$ in the range of $15\~120\;m^3/h$. According to the uncertainty budget, the uncertainties of the fluid density and the final mass measurement, which are temperature dependent, contribute about $94\%$ of the total uncertainty in the oil flow standard system

Hydrate formation/dissociation mechansims in sediments and their implications to the exploration and the production (퇴적물 내의 하이드레이트 생성/해리 메커니즘과 탐사 및 개발생산에의 적용)

  • Lee, J.Y.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.588-590
    • /
    • 2008
  • The thermal signature of nucleation process is characterized by the induction time, the degree of supercooling, and the equilibrium temperature depression. The initiation of nucleation presents stochastic characteristics. The factors that affect nucleation are mechanical impact, ionic concentration, mineral surface characters, and pore size. Hydrate-bearing sediments behave mechanically like other cemented sediments. The data set has important implications for the calibration and interpretation of geophysical measurements and downhole logs collected in gas hydrate provinces, providing particular insight for the interpretation of P- and S-wave data and resistivity logs. In addition, laboratory formation history and ensuing pore-scale spatial distribution likely have a more pronounced effect on the macroscale mechanical properties of hydrate-bearing sediments

  • PDF

Review on Measured Stress and Flow Stress at Room-Temperature Compression Test (상온압축시험에서 측정응력과 유동응력과의 관계고찰)

  • Park J. S.;Lee Y. S.;Lee J. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.05a
    • /
    • pp.13-15
    • /
    • 2001
  • Compression test has been used to measure material flow stress due to limited capability of tensile test at the fast strain rate. Since the frictional stress unavoidable during compression test should be properly eliminated from the measured stress, calibration of the measured stress by using friction factor has been made for the flow stress measurement. Also, calibrated stresses by interrupted and continuous compression tests have been compared with the true stress measured by tensile test at $0.2\%$ carbon steel.

  • PDF

Quantitation and Validation of Atorvastatin using HPLC-UV

  • Heine, Daniel;Yong, Chul-Soon;Kim, Jung-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.187-192
    • /
    • 2007
  • A reversed phase HPLC analysis of atorvastatin (AS) standard solution was performed using diclofenac (DF) as internal standard. Column oven temperature, flow rate and the composition of the mobile phase were varied in order to determine a practical system setup using a C18 column and UV detector. Two C18 columns of different length were compared regarding their influence on the AS peak shape. Based on these preliminary experiments a validation study was performed utilizing a C18 column at $62^{\circ}C$ with a mobile phase consisting of sodium phosphate buffer (0.05 M, pH 4.0), methanol and acetonitrile (40:50:10, v/v/v). The detection limit for AS was $0.1{\mu}g/ml$ and inter- and intra-day calibration curves were linear over a concentration range of $0.2-50{\mu}g/ml$. Accuracy and precision were satisfactory in the AS concentration range of $0.5-50{\mu}g/ml$.

Evaluation of the Measurement of Trace Phenols by Adsorption/Thermal Desorption/Gas Chromatography/Mass Spectrometry (ATD/GC/MS) in Artificial Air (흡착관/열탈착 GC/MS 방법에 의한 모사시료 중의 미량 페놀 분석에 관한 평가)

  • 허귀석;이재환;황승만;정필갑;유연미;김정우;이대우
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.2
    • /
    • pp.127-137
    • /
    • 2002
  • Phenolic compounds in air are toxic even at their low concentrations. We had evaluated a total of five phenolic compounds (Phenol, o-Cresol, m-Cresol, 2-Nitrophenol and 4-Chloro-3-methylphenol) in artificial air using a combination of ATD/GC/MS. To compare the adsorption efficiency of these phenolic compounds, three adsorbents (Tenax TA, Carbotrap and Carbopack B) were tested. Tenax TA adsorbent was most effective of all the adsorbents used for the efficiency test. Five phenolic compounds were found to be very stable on adsorbent tubes for 4 days at room temperature. Detection limit of five phenolic compounds ranged from 0.05 to 0.08 ppb (when assumed to collect 10 L air). The calibration curve was linear over the range of 22∼ 164 ng. The reproducibility was less than 4%. Sampling of duplicate pairs (DPs) was made to demonstrate duplicate precision and sampling efficiency.

Development of A smart pressure transducer (지능형 압력 변환기 개발)

  • Park, Chan-Won;Min, Nam-Gi
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.8
    • /
    • pp.941-947
    • /
    • 1999
  • As pressure transducers are employed in many fields such as production facilities, test facilities vehicles and industrial machinery, there is an increasing need for high precision measurement of pressure without any calibration or maintenance. In this paper, we discuss the development of a smart thin film pressure transducer which is highly suitable for a precise measurement of pressure. The smart functions include automatic zero tracking, automatic span adjustment, temperature compenstion, continuous self-diagnostics for faults (open strain gages, abnormal data, incorrect A/D conversion, and overpressure), data memory and multi-drop communication with PC

  • PDF

Feeding System Design/Analysis Using Test Data Correlation Method (Test data 보정기법을 활용한 추진기관 공급계 설계/해석)

  • Cho, Nam-Kyung;Jeong, Yong-Gahp;Han, Sang-Yeop;Kim, Young-Mog
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.127-131
    • /
    • 2006
  • An optimization algorithm is applied to a calibration task. In this paper, test data correlation, a reverse analysis method, is presented. With this method, flow rate and heat transfer rate, which are difficult to be measured are estimated using measured pressure and temperature data for helium pressurization system of launch vehicle.

  • PDF

Source-Follower Type Analog Buffer Using Low Temperature Poly-Si TFTs for AMLCDs

  • Chen, Bo-Ting;Tai, Ya-Hsiang;Wei, Ying-Jyun;Tsai, Chun-Chien;Chen, Hsu-Hsin;Huang, Chun-Yao;Kuo, Yu-Ju;Cheng, Huang-Chung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1243-1246
    • /
    • 2006
  • A new source follower circuit for the integrated circuit of AMLCDs is proposed. Active load is added and calibration operation is applied to compensate the circuits. Proposed circuit is capable of minimizing the variation from both timing and device variations through measured results, the uniformity and bias effect are discussed.

  • PDF

Calibration and Validation of the Estimated Chlorophyll a Derived from KOMPSAT/OSMI Data and Fisheries Application in the East China Sea

  • Suh Young-Sang
    • Journal of Environmental Science International
    • /
    • v.14 no.10
    • /
    • pp.911-917
    • /
    • 2005
  • A comparison between the estimated chlorophyll a from OSMI, the SeaWiFS and the chlorophyll a measured from the research cruises of National Fisheries Research and Development Institute was made. The updated empirical algorithm for calibrating and validating of the estimated chlorophyll a in the East China Sea was formulated by relationship between the estimated chlorophyll a and the field one. The relationship between the chlorophyll a and the band ratio(nLw490/555) was still highest in the OSMI data after launching of KOMPSAT satellite. The distributions of OSMI chlorophyll a were compared with those of sea surface temperature, zooplankton biomass, and catch amounts of the Pacific mackerel in the East China Sea. In case of the relationships in specially winter seasons of 2002 and 2004, the zooplankton and the fish were totally depended on the distributions of SST than those of chlorophyll a.