• Title/Summary/Keyword: temperature and oxygen requirements

Search Result 25, Processing Time 0.029 seconds

Tropical red alga Compsopogon caeruleus: an indicator of thermally polluted waters of Europe in the context of temperature and oxygen requirements

  • Andrzej S., Rybak;Andrzej M., Woyda-Ploszczyca
    • ALGAE
    • /
    • v.37 no.4
    • /
    • pp.301-316
    • /
    • 2022
  • The red alga Compsopogon caeruleus can generally be found in tropical and subtropical waters worldwide. In addition to its natural habitats, this species may be found in waters that receive abnormally hot water, e.g., from powerhouses. To date, the presence of C. caeruleus has not been observed in thermally polluted lacustrine ecosystems in Poland, which has a moderate climate. The thalli of this red alga were found growing on Vallisneria spiralis in Lichenskie Lake. Importantly, this paper presents a previously unknown relationship between the temperature (20, 25, 30, 35, and 40℃) and oxygen requirements of C. caeruleus (based on ex situ measurements of O2 consumption by thalli). Surprisingly, 35℃ can be the optimum temperature for C. caeruleus, and this temperature is higher than the values reported by some previous thermal analyses by approximately 10℃. Additionally, we reviewed and mapped the distribution of this nonnative and mesophilic red alga in natural / seminatural water ecosystems in Europe. Finally, we propose that the occurrence of C. caeruleus mature thalli can be a novel, simple and easy-to-recognize bioindicator of artificially and permanently heated waters in moderate climate zones by a regular discharge of postindustrial water.

A Study of the Oxygen Plasma Treatment on the Serviceability of a Wool Fabric

  • Kan, C.W.;Chan, K.;Yuen, C.W.M.
    • Fibers and Polymers
    • /
    • v.5 no.3
    • /
    • pp.213-218
    • /
    • 2004
  • Low temperature plasma (LTP) treatment using oxygen gas was applied to a wool fabric. The LTP treated wool fabric was tested with several methods: ASTM D5035-1995, ASTM D1424-1996, AATCC Test Method 99-2000, AATCC Test Method 61-2001 lA, AATCC Test Method 15-2002 and AATCC Test Method 8-2001 and the results were compared with the industrial requirements (ASTM D3780-02 and ASTM D4155-0l). The results revealed that the LTP treated wool fabric could fulfil the industrial requirements. The results of the investigation were discussed thoroughly in this paper.

Analysis of Liquid Oxygen Feeding System for Pump-Fed Liquid Propulsion Rocket

  • Cho, Nam-Kyung;Kwon, Oh-Sung;Cho, In-Hyun;Kim, Young-Mog
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.211-215
    • /
    • 2004
  • For design of cryogenic propellant feeding system, one of the main requirements is to meet temperature requirement for satisfying turbo-pump NPSH requirement. In this paper improved method of estimating the thermal stratification in liquid oxygen tank is presented to help design. In the case of liquid rocket using turbo-pump, the inner pressure of liquid oxygen tank is maintained low, so vaporization of liquid oxygen is generally occurred. In this paper, inner process of LOX tank is analyzed by two phase flow modeling. The vaporization rate and required helium mass is investigated.

  • PDF

Design Requirements by Evaluating Comfort while Wearing Korean Naval Duty Uniforms for Summer and Winter (대한민국 동하절기 해군 함상복의 착용쾌적성 평가를 통한 디자인 요소 요구성능 분석)

  • Lee, Hyo-Hyun;Shin, Sora;Lee, Joo-Young
    • The Korean Journal of Community Living Science
    • /
    • v.27 no.3
    • /
    • pp.419-435
    • /
    • 2016
  • The purpose of the present study was to suggest the design requirements for Korean naval duty uniforms by evaluating the physiological and psychological comfort while wearing the uniforms. Two sets of wear trials were conducted with summer uniforms(eight young males) and winter uniforms(seven other young males). The summer wear trial consisted of 10-min rest, 60-min exercise, and 10-min recovery at an air temperature($T_{air} $) of $33^{\circ}C$ and 62%RH, followed by 10-min recovery at a $T_{air} $ of $23^{\circ}C$ and 64%RH(total 90 min). The winter wear trial consisted of 20-min rest at $T_{air} $ $20^{\circ}C$ and 55%RH, 25-min rest, 30-min exercise, and 35-min recovery at a $T_{air} $ of 0oC and 43%RH(total 110 min). Rectal and seven skin temperatures, clothing microclimate, heart rate, oxygen consumption, total sweat rate, and subjective perceptions were measured during the wear trials. By evaluating the experimental results from the wear trials, we extracted the following psycho-physiological design requirements to improve the current Korean naval uniforms: (1) It is important to maintain the skin temperatures within their comfort range, which depends on the body region (higher than $30^{\circ}C$ in winter, but less than $35^{\circ}C$ in summer). (2) In summer, the feet should be protected from the high heat of the ship floor surface. (3) In summer, sweat from the back should be sufficiently absorbed and allowed to dry quickly.

Effect of deposition parameters on structure of ZnO films deposited by an DC Arc Plasmatron

  • Penkov, Oleksiy V.;Chun, Se-Min;Kang, In-Jae;Lee, Heon-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.255-255
    • /
    • 2011
  • Zinc oxide based thin films have been extensively studied in recent several years because they have very interesting properties and zinc oxide is non-poisonous, abundant and cheap material. ZnO films are employed in different applications like transparent conductive layers in solar cells, protective coatings and so on. Wide industrial application of the ZnO films requires of development of cheap, effective and scalable technology. Typically used technologies don't completely satisfy the industrial requirements. In the present work, we studied effect of the deposition parameters on the structure and properties of ZnO films deposited by DC arc plasmatron. The varied parameters were gas flow rates, precursor composition, substrate temperature and post-deposition annealing temperature. Vapor of Zinc acetylacetone was used as source materials, oxygen was used as working gas and argon was used as the cathode protective gas and a transport gas for the vapor. The plasmatron power was varied in the range of 700-1500 watts. Flow rate of the gases and substrate temperature rate were varied in the wide range to optimize the properties of the deposited coatings. After deposition films were annealed in the hydrogen atmosphere in the wide range of temperatures. Structure of coatings was investigated using XRD and SEM. Chemical composition was analyzed using x-ray photoelectron spectroscopy. Sheet conductivity was measured by 4-point probe method. Optical properties of the transparent ZnO-based coatings were studied by the spectroscopy. It was shown that deposition by a DC Arc plasmatron can be used for low-cost production of zinc oxide films with good optical and electrical properties. Increasing of the oxygen content in the gas mixture during deposition allow to obtain high-resistive protective and insulation coatings with high adhesion to the metallic surface.

  • PDF

Development of Propellant for Turbopump Pyro Starter (터보펌프 시동기용 추진제 개발)

  • Song, Jong-Kwon;Choi, Sung-Han;Hong, Moon-Geun;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.7-10
    • /
    • 2009
  • The development and evaluation of solid propellant were performed for the turbopump pyro starter, which start up the liquid propellant rocket engine for the Space Launch Vehicle (SLV). Requirements for the turbopump pyro starter propellant include the production of low flame temperature, low burning rate and nontoxic gas to protect the mechanical corrosion or air pollution. This study describes the development of the solid propellant composition which is based on PCP binder. DHG (Dihydroxy glyoxime), which has advantages of oxygen balance and ignition, was used as coolant. The mechanical properties and burning rate of the propellants were measured. Finally, static fired test was performed to prove the possibility of development.

  • PDF

A Numerical Study on a High-Temperature Air Combustion Burner for a Compact Fuel-Cell Reformer (연료전기용 컴팩트형 개질기의 고성능화를 위한 고온 공기 연소 기술의 적용에 관한 연구)

  • Lee, Kyoung-Ho;Kwon, Oh-Chae
    • Journal of Hydrogen and New Energy
    • /
    • v.16 no.3
    • /
    • pp.229-237
    • /
    • 2005
  • A new burner configuration for a compact fuel-cell reformer with a high-temperature air combustion concept was numerically studied. The burner was designed for a 40 $Nm^3/hr$ hydrogen-generated reformer using natural gas-steam reforming method. In order to satisfy the primary requirements for designing a reformer burner (uniform distribution of temperature along the fuel processor walls and minimum heat losses from the reformer), the features of the present burner configuration included 1) a self-regenerative burner for an exhaust-gas-recirculation to apply for the high-temperature air combustion concept, and 2) an annular-type shield for protecting direct contact of flame with the processor walls. For the injection velocities of the recirculated gas of 0.6-2.4 m/s, the recirculated gas temperature of 1000 K, and the recirculated oxygen mole fraction of 4%, the temperature distributions along the processor walls were found uniform within 100 K variation. Thus, the present burner configuration satisfied the requirement for reducing temperature gradients along the processor walls, and consequently demonstrated that the high-temperature air combustion concept could be applied to the practical fuel reformers for use of fuel cells. The uniformity of temperature distribution is enhanced as the amount of the recirculated gas increases.

The Effect of Biodiesel Oxidation Deterioration on Emission (바이오디젤의 산화가 배출가스에 미치는 영향)

  • Song, Hoyoung;Lee, Minho;Kim, Kiho;Jung, Choongsub
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.220.2-220.2
    • /
    • 2011
  • Biodiesel and biodiesel blend fuel are receiving increasing attention as alternative fuels for diesel engines without substantial modifications. Biodiesel fuels and blending have been widely studied and applied in diesel engine because of biodiesel's lower sulfur, lower aromatic hydrocarbon and higher oxygen content. Biodiesels have the potential to be oxidized in different condition. It has reported that oxidation deterioration of biodiesel is different in the condition of storage and oxidation causes chemical property change of methyl esters. Sunlight intensity, temperature, material of container and contact surface with oxygen are key dominant factors accelerating oxidation deterioration. In this study, we chose temperature among key oxidation conditions and metal container filled with biodiesel was heated at about $110^{\circ}C$ for 10 days in order to accelerate oxidation deterioration. To better understand the effect of biodiesel blends on emission, steady state tests were conducted on a heavy duty diesel engine. The engine was fueled with Ultra Low Sulphur Diesel(ULSD), a blend of 10% and 20%(BD10, BD20) on volumetric basis, equipped with a common rail direct injection system and turbocharger, lives up to the requirements of EURO 3. The experimental results show that the blend fuel of normal biodiesel with BD10 and BD20 increased NOx. The result of PM was similar to diesel fuel on BD10, but the result of PM on BD20 was increased about 63% more than its of diesel. The blend fuel of Oxidation biodiesel with BD10 and BD20 increased NOx as the results of normal biodiesel. But PM was all increased on BD10 and BD20. Especially THC was extremely increased when test fuel contains biodiesel about 140% more than its of diesel. Through this study, we knew that oxidation deterioration of biodiesel affects emission of diesel engine.

  • PDF

A Study on the Development of Oxygen Cluster Ion Generator for Sterilization of Bio Clean Room(BCR) (Bio Clean Room(BCR)의 멸균을 위한 산소 클러스터이온 발생 장치 개발에 관한 연구)

  • Park, Dong-Il;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • Bio Clean Room(BCR) and pharmaceutical product manufacturing facilities require careful assessment of many factors, including HVAC, controls, room finishes, process equipment, room operations, and utilities. Flow of equipment, personnel, and product must also be considered along with system flexibility, redundancy, and maintenance shutdown strategies. It is important to involve designers, operators, commissioning staff, quality control, maintenance, constructors, validation personnel, and the production representative during the conceptual stage of design. Critical variables for room environment and types of controls vary greatly with the clean space's intended purpose. It is particularly important to determine critical parameters with quality assurance to set limits and safety factors for temperature, humidity, room pressure, and other control requirements. In this paper, oxygen cluster ion equipment was utilized in order to enhance the indoor air quality and to prevent the airborne infection of ward in hospital. Moreover, the performance test of the equipment was also performed in order to develop the optimal sterilization system of BCR using the equipment.

Direct Seeding Cultivation on Submerged Paddy in Rice II. Dissolved Oxygen Uptake and Germination Properties of Rice Varieties in the $O_2$ Saturated Water (벼 담수토중 직파 재배 연구 II. 벼 품종의 수중발아시 용존산소 흡수와 발아특성)

  • Lee, Chul-Won;Seong, Ki-Yeong;Park, Seok-Hong;Park, Rae-Kyeong;Cho, Dong-Sam
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.33 no.1
    • /
    • pp.97-101
    • /
    • 1988
  • The objective of this paper was to examine the oxygen requriement of rice seeds when the seeds were germinating under the water. The trial was carried out in the laboratory with the different water temperature (25$^{\circ}C$, 17$^{\circ}C$) in the Crop Experiment Station, Suwon. The tested varieties were 6 in japonica and 6 in indica (I) ${\times}$ japonica (J). In the 25$^{\circ}C$ water temperature rice seeds absorbed more dissolved oxygen (DO) and germinating duration was shorter than in the 17$^{\circ}C$ water temperature. DO uptake of japonica rice seeds was faster than that of indica ${\times}$ japonica rice seeds, and the germinating ratio of japonica rice seeds was higher than that of I${\times}$J rice seeds in the water. DO requirements of germinating rice seeds in the water were average 82.4 ${\mu}$g per seed up to coleoptile appearance and average 123.6 ${\mu}$g per seed up to appearance of radicle in the japonica varieties, but I${\times}$J varieties were 96.9 ${\mu}$g and 145.1 ${\mu}$g respectively. Especially when the rice seeds were germinated in the water, length of coleoptile and radicle of japonica rice were significantly longer than those of I${\times}$J rice varieties.

  • PDF