• 제목/요약/키워드: temperature and humidity variation

검색결과 303건 처리시간 0.026초

낙동강 하구둑 건설 전·후의 기상환경 변화 특성 (Characteristics of Meteorological Environment Variation Before and After Construction of Nak-dong River Estuary Barrage)

  • 전병일
    • 환경영향평가
    • /
    • 제14권3호
    • /
    • pp.135-145
    • /
    • 2005
  • This study was conducted to investigate the characteristics of meteorological environment variation before and after construction of Nak-dong river estuary barrage. We used meteorological data(air temperature, precipitation, relative humidity, visibility, wind) at Gimhae airport meteorological station. The construction of river estuary barrage can change climate at the neighboring districts and influence human's health and vegetable. The construction of Nakdong river estuary barrage brought rise of temperature, decrease of relative humidity and increase of poor visibility frequency.

Influence of Temperature and Relative Humidity in Infection of Nosema bombycis (Microsporidia: Nosematidae) and Cross-infection of N. mylitta on Growth and Development of Mulberry Silkworm, Bombyx mori

  • Chakrabarti, Satadal;Manna, Buddhadeb
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제17권2호
    • /
    • pp.173-180
    • /
    • 2008
  • The influence of temperature and relative humidity in infection and cross-infection of Nosema bombycis and N. mylitta respectively in mulberry silkworm, Bombyx mori L. on larval mortality, multiplication of pathogens, larval weight and growth rate in three different seasons were studied. Seasons were selected in such condition, when very less fluctuations between minimum and maximum temperature and minimum and maximum relative humidity ($25{\sim}28^{\circ}C$ and $65{\sim}72%$ R.H) was observed i.e., season-1. Fluctuations between minimum and maximum temperature were less ($28.05{\sim}34.50^{\circ}C$) but R.H % was more ($55{\sim}81%$) in season-2. Fluctuations between minimum and maximum temperature and R.H % were more ($20.00{\sim}40.5^{\circ}C$ and $64.00{\sim}90.00%$) in season-3. Growth rate of microsporidian-infected silkworm is directly related to the prevailing temperature and relative humidity in silkworm. Silkworm can tolerate slight variation of temperature but slight variation of relative humidity disfavours the development of silkworm and favours the multiplication of pathogens.

외피 유형별 석재 모형돔의 동절기 환경 특성에 관한 연구 (A study on the characteristics of environmental factors of granite dome models with different envelope structures in winter)

  • 공성훈
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.642-646
    • /
    • 1999
  • Factors governing the rate of heat exchange comprise the air temperature, the speed of air movement, relative humidity, and relation indoors. Recently, there are many researches on the transient analysis of indoor environmental factors such as the dry bulb temperature, relative humidity and air velocity in miniature models. The purpose of this study is to measure the environmental factors and to analyze and evaluate the characteristics of indoor environment with the different envelope structures using a granite dome model. According to the variation of humidity, the state of interior relative humidity for clay model has an equal tendency, although a little range of variation is shown in comparison to the cement model.

  • PDF

습도 변화에 따른 뇌파 기반 생체신호 변화에 관한 연구 (A Study on the Variation of Physiology Signals based on EEG with Humidity)

  • 김명호;김정민
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.50-55
    • /
    • 2013
  • Subjects with 0.7[clo]'s amount of clothing were estimated on their thermal comfort, concentrativeness, heart rate variability, stress and fatigue degree when given variation in relative humidity to 30, 40, 50, 60, 70, and 80[RH%], in an environmental test room of temperature 25[$^{\circ}C$], illumination 1000[lux] and air velocity 0.02[m/sec], by using EEG, learning ability and HRV. At the result, it was at 50~60[RH%] of relative humidity that subject's thermal comfort and concentrativeness were at the highest while stress were at the lowest, and it was at 60[RH%] of relative humidity that heart rate variability was most stabilized. It was found that when temperature and humidity of the environmental test room are at 25[$^{\circ}C$] and 50~60[RH%], subject's productivity and psychological state are least affected.

양생직후 초기재령의 콘크리트 내부 온도와 상대습도의 측정 및 분석 (Investigation of Internal Temperature and Relative Humidity of Concrete Immediately After Mix and Placement)

  • 박철우;박영훈;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1065-1068
    • /
    • 2008
  • Concrete is still one most common construction materials even in railway structures. As structures become massive and mega-sized, the importance of early age concrete quality control becomes more significant. Among various factors, relative humidity and temperature are the primary factors governing the early age quality. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

Theoretical and Experimental Considerations of Thermal Humidity Characteristics

  • Choi, Seok-Weon;Cho, Ju-Hyeong;Seo, Hee-Jun;Lee, Sang-Seol
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제3권1호
    • /
    • pp.9-18
    • /
    • 2002
  • Thermal humidity characteristics were considered theoretically and experimentally. A Simply well-fitted correlation of a saturated vapor pressure-temperature curve of water was introduced based on Antoine equation to make theoretical prediction of relative humidity according to temperature variation. Characteristics of dew point were also examined theoretically and its relation with temperature and humidity was evaluated. The exact mass of water vapor in a specified humidity and temperature condition was estimated to provide useful insight into the idea about how much amount of water corresponds to a specified humidity and temperature condition in a confined system. A simple but well-fitting model of dehumidification process was introduced to anticipate the trend of relative humidity level during GN2(gaseous nitrogen) purge process in a humidity chamber. Well-suitedness of this model was also verified by comparison with experimental data. The overall appearance and specification of two thermal humidity chambers were introduced which were used to perform various thermal humidity tests in order to yield useful data necessary to support validity of theoretical models.

하절기, 석재 모형돔의 외피 유형별 실내환경 요소에 관한 연구 (A study on indoor environmental elements of the granite model dome in different envelope materials during summer season)

  • 공성훈
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.898-902
    • /
    • 1999
  • During summer season, the weather condition of Korea is hot and humid. So humidity elements are very important relating to building envelope condition. The purpose of this investigation is to measure and analyze characteristics of summer's environmental elements such as relative humidity, dry bulb temperature and air velocity in the clay/cement envelope materials using a granite dome model. According to the variation of exterior humidity, the state of interior relative humidity for clay model has an equal tendency, although a little range of variation is shown in comparison to the cement model.

  • PDF

접촉연소식 가스 센서를 이용한 감도특성 (Gas Detecting Characteristics Using Catalytic Combustion Type Gas Sensor)

  • 윤헌주;고길영;이종필;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.773-777
    • /
    • 2002
  • In this study, we analyzed the LPG and LNG sensitivity measurement and voltage variation using catalytic type gas sensor characteristics in catalytic combustion type gas detecter sensors. gas detector shall operate as intended when exposed for 24 hours to air having a relative humidity of 0~85 percent at a temperature of $20[{\mu}m]$ and humidity of 45 percent at a temperature of $-10{\sim}40[^{\circ}C]$ the gas detecter sensors are to be subjected to operation for 210 days in an area that has been detemined to be equivalent to a typical residential atmosphere with an air velocity of 50 [cm/sec]. The source of energy for a gas detector sensors employing a supplementary basic circuit is energized from a separate source of supply direct applied voltage 2.1[V], 2.2[V], 2.3[V]. As a result, it was confirmed that the relative humidity and temperature by regression each analysis, compared to the LPG characteristic graph and methane characteristics graph by a relative humidity of 0 ~ 85 [%] at a temperature range of $-10{\sim}40[^{\circ}C]$ show a similar linear pattern on the whore.

  • PDF

PAD & FAN 시스템에 대한 온실폭방향의 온. 습도 변화 (The temperature and humidity variation along the width of greenhouse with Pad & Fan system)

  • 이종원;이석건;이현우;김란숙;최상환
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.262-268
    • /
    • 1998
  • This study were performed to find the cooling effect and to provide design data during summer season. for the Pad & Fan system of Venlo type greenhouse. The temperature and humidity variation along the greenhouse width and wind velocity in the greenhouse were surveyed. Also, the influence of shading on the cooling effect were analyzed. While Pad & Fan system were operated, the temperature, humidity and wind velocity in greenhouse were different by the distance from the Pad and the height from the ground. The temperature difference between Pad and Fan was about 8.1$^{\circ}C$~10.4$^{\circ}C$ without shading and about 4.4$^{\circ}C$~5.5$^{\circ}C$ with shading.

  • PDF

온습도 변화에 따른 철도차량 바닥재의 변형 (Deformation of the floor structure of railway vehicle depending on temperature and humidity)

  • 신범식;김명수;최연선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1002-1007
    • /
    • 2008
  • The floor structure of railway vehicle can deflect and warp due to variation of temperature and humidity at the inside and outside of vehicle. In this study, its temperature and humidity characteristics was investigated experimentally for beam and plate specimen and numerically for the floor structure assembly. The temperature and humidity characteristics of a part were measured and the deformation and stress distribution of the floor structure were calculated using a commercial software. And the warp deformation of the plywood was measured experimentally. The results show that the temperature and humidity effects on the floor structure are the important factor to decide the strength and the quality of the floor structure of railway vehicles.

  • PDF