• 제목/요약/키워드: temperature analysis

검색결과 19,344건 처리시간 0.044초

2015년 4월에 제주 서부해역에서 발생한 수온역전층 특성 (Characteristics of Water Temperature Inversion Observed in a Region West of Jeju Island in April 2015)

  • 김성현
    • Ocean and Polar Research
    • /
    • 제42권2호
    • /
    • pp.97-113
    • /
    • 2020
  • In-situ observations were carried out in April 2015 to investigate the occurrence of water temperature inversion in a region west of Jeju Island. Analysis of in-situ in the western part of Jeju island showed that cold water moved to the southeast from the surface to the middle layer and warm water moved from the middle to the lower layer of the northwest direction. The water temperature inversion occurred at 84 stations (63.1%) out of 133 stations. At the boundary of the water temperature inversion layer, it was formed in the middle layer and disappeared. In the strongly appearing, it started from the middle layer to the lower layer. The shape of the water temperature inversion layer was different. As a result of horizontal water temperature slope analysis of the water temperature inversion zone, maximum 0.23℃/km was obtained and the mean was 0.06℃/km. The role of water temperature inversion as an indicator to determine the formation of water front. As a result of the water mass analysis, Jeju Warm Current Water and Tsushima Warm Current Water of high temperature and high salt intruded from the middle to the bottom. In the middle layer occurred as the Yellow Sea Cold Water of low water temperature and low salinity expanded.

Numerical and experimental investigation on the temperature distribution of steel tubes under solar radiation

  • Liu, Hongbo;Chen, Zhihua;Zhou, Ting
    • Structural Engineering and Mechanics
    • /
    • 제43권6호
    • /
    • pp.725-737
    • /
    • 2012
  • The temperature on steel structures is larger than the ambient air temperature under solar radiation and the temperature distribution on the affected structure is non-uniform and complicated. The steel tube, as a main structural member, has been investigated through experiment and numerical analysis. In this study, the temperature distribution on a properly designed steel tube under solar radiation is measured. A finite element transient thermal analysis method is presented and verified by the experimental results and a series of parametric studies are carried out to investigate the influence of various geometric properties and orientation on the temperature distribution. Furthermore, a simplified approach is proposed to predict the temperature distribution of steel tube. Based on both the experimental and the numerical results, it is concluded that the solar radiation has a significant effect on the temperature distribution of steel tubes. Under the solar radiation, the temperature of steel tubes is about $20.6^{\circ}C$ higher than the ambient air temperature. The temperature distribution of steel tubes is sensitive to the steel solar radiation absorption, steel tube diameter and orientation, but insensitive to the solar radiation reflectance and thickness of steel tube.

3차원 열전달을 고려한 틸팅패드 스러스트 베어링의 해석 (Three-Dimensional Beat Transfer Analysis on Tilting-Pad Thrust Bearings)

  • 김호종;최성필;하현천
    • Tribology and Lubricants
    • /
    • 제22권4호
    • /
    • pp.173-181
    • /
    • 2006
  • In the present study, we developed a numerical analysis software to predict performance of tilting-pad thrust bearings. The finite element method was adopted to compute lubricant film pressure and temperature. Three-dimensional heat transfer equations were solved simultaneously for the lubricant film, pad, and runner. Groove temperature was assumed with two different models. From application of the software to a thrust bearing, it has been seen that the three-dimensional analysis predicts higher temperature than the average temperature analysis. It has also been found that the groove model with a hot-oil-carry-over factor predicts higher temperature.

600W급 IPMSM의 고정자 설계 변수 변화에 따른 온도 특성 분석 및 고찰 (Analysis of IPMSM Temperature Characteristics based on Stator Design Parameters)

  • 고덕화;김용태;김규탁
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1201-1206
    • /
    • 2017
  • In this paper, the temperature characteristics by change the width of teeth and yoke in the stat or parameters were analyzed. An initial model of fill factor 45 [%] was produced. Through the experiment, the validity of the temperature analysis using the thermal equivalent circuit method was verified. So, initial model was selected as basic model. Also, temperature characteristic analysis was performed for each width change of the stator teeth and yoke, and the effects of the width of stator teeth and yoke on the temperature characteristics were analyzed.

Behavior of symmetrically haunched non-prismatic members subjected to temperature changes

  • Yuksel, S. Bahadir
    • Structural Engineering and Mechanics
    • /
    • 제31권3호
    • /
    • pp.297-314
    • /
    • 2009
  • When the temperature of a structure varies, there is a tendency to produce changes in the shape of the structure. The resulting actions may be of considerable importance in the analysis of the structures having non-prismatic members. Therefore, this study aimed to investigate the modeling, analysis and behavior of the non-prismatic members subjected to temperature changes with the aid of finite element modeling. The fixed-end moments and fixed-end forces of such members due to temperature changes were computed through a comprehensive parametric study. It was demonstrated that the conventional methods using frame elements can lead to significant errors, and the deviations can reach to unacceptable levels for these types of structures. The design formulas and the dimensionless design coefficients were proposed based on a comprehensive parametric study using two-dimensional plane-stress finite element models. The fixed-end actions of the non-prismatic members having parabolic and straight haunches due to temperature changes can be determined using the proposed approach without necessitating a detailed finite element model solution. Additionally, the robust results of the finite element analyses allowed examining the sources and magnitudes of the errors in the conventional analysis.

LTP 퍼니스의 내부 유동 및 온도 균일도 최적화를 위한 실천공학교육적 문제해결 (Problem Solving about Practical Engineering Education based on Analysis on Optimized Internal Flow of LTP Furnace and Uniformity of Temperature)

  • 김진우;윤기만;조은정
    • 실천공학교육논문지
    • /
    • 제10권2호
    • /
    • pp.125-129
    • /
    • 2018
  • 이 논문은 LTP 퍼니스의 최적화 된 내부 유동과 온도의 균일성에 대한 수치 해석에 관한 것이다. 반도체 제조 공정에서 실리콘 웨이퍼를 어닐링하기 위한 기능을 수행한다. 특히 챔버 내부의 최고 온도를 약 $400^{\circ}C$의 고온으로 유지하여 웨이퍼를 보강한다. 공정이 고온에서 완료되면 열 교환기를 통해 온도를 낮추고 이를 수행하기 위한 작업이 반복된다. 이 논문에서 최종적인 목표는 LTPS 퍼니스의 유동 해석을 통해 챔버의 단열 공급과 배기 구조의 최적 설계를 도출하는 것과 교육과정 개발을 위한 사례 발굴에 있다.

플라즈마 용사층에 발생하는 응력해석 (Analysis of thermal stresses developed in plasma sprayed layer)

  • 배강열;김희진
    • Journal of Welding and Joining
    • /
    • 제8권4호
    • /
    • pp.58-68
    • /
    • 1990
  • The formation of thermal stresses by plasma spraying is generally considered as adverse. Therefore, the knowledge of stress distribution in the deposited layer during and after plasma spraying will be of special interest. In this study finite difference heat transfer analysis and finite element stress analysis were carried out to predict the change of stress distribution in the plasma coated layer with the variations of preheat temperature, number of scan, particle size, and bond coat. The results of the numerical analysis were as follows: 1) Transient stresses developed in the coated layer were up to the level of yiedl strength at the temperature. 2) The tensile stresses were developed in the deposited layer and the surface of the substrate, but the compressive stresses were developed in the rest of the substrate. 3) Transient and residual stresses were significantly affected by the preheat temperature. 4) The variations of temperature of powder particle and number of torch scan changed tensile stress distribution, but made no difference on the magnitude of the stresses. 5) Bond coated layer reduced the stree level of deposited layer.

  • PDF

용접물성치를 고려한 소형 공정열교환기 시제품의 고온구조해석 (High-Temperature Structural Analysis on the Small-Scale PHE Prototype using Weld Properties)

  • 송기남;홍성덕;박홍윤
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.1-6
    • /
    • 2012
  • A PHE (Process Heat Exchanger) in a nuclear hydrogen system is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature gas cooled Reactor) to the chemical reaction that yields a large quantity of hydrogen. A small-scale PHE prototype made of Hastelloy-X is being tested in a small-scale gas loop at Korea Atomic Energy Research Institute. Previous research on the high-temperature structural analysis of the small-scale PHE prototype had been performed only using parent material properties. In this study, high-temperature structural analysis using weld properties in weld zone was performed and the analysis results compared with the previous research.

배기계 내구시험 중의 온도 변화 예측을 위한 연구 (A Study on the Prediction of Temperature Change during the Thermal Fatigue Test of Exhaust Manifolds)

  • 이원근
    • 한국자동차공학회논문집
    • /
    • 제11권5호
    • /
    • pp.29-36
    • /
    • 2003
  • Exhaust manifolds suffer from serious temperature variation during the thermal fatigue test. The spatial distribution of temperature changes at each moment. Because transient flow can not be simulated during the long period of temperature change, the simulation can not be performed by conjugate heat transfer analysis. In this study, a new procedure for transient thermal analysis is established by decoupling fluid-solid analysis. The procedure consists of (1) transient CFD calculation (2 cycles), (2) mapping heat transfer coefficient to the inner surface of solid mesh as a boundary condition of heat conduction analysis and (3) transient heat conduction analysis in the long period (30 min). The realistic temperature change can be predicted by this procedure.

CO2 기반 금형 급속 냉각기술의 수치해석적 연구 (Numerical Analysis of CO2-Based Rapid Mold Cooling Technology)

  • 최재혁
    • Design & Manufacturing
    • /
    • 제17권3호
    • /
    • pp.61-66
    • /
    • 2023
  • In this study, we developed a simulation methodology for a technology that rapidly cools molds by directly spraying them with CO2 in its liquefied gaseous state. Initially, a simulation verification process was conducted using ANSYS Fluent's heat transfer analysis based on temperature values measured in prior research experiments, ensuring a comparable temperature could be calculated. Subsequently, the validated analysis method was employed to evaluate design factors that exert the most significant influence on cooling. An evaluation was conducted based on three factors: part thickness, mold thickness, and the melting temperature of material. Using a full factorial design approach, a total of 27 analyses were completed and subsequently calculated through analysis of means. The impact assessment was carried out based on the temperature values at the product's core. The results indicated that the thickness of the mold had the highest influence, while the melting temperature of material had the least.