• 제목/요약/키워드: temperature analysis

검색결과 19,344건 처리시간 0.045초

소형 공정열교환기 시제품의 고온구조해석 (High-temperature Structural Analysis on the Small Scale PHE Prototype)

  • 송기남;이형연;홍성덕;박홍윤
    • 한국압력기기공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.57-64
    • /
    • 2010
  • PHE(Process Heat Exchanger) is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR(Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute established the gas loop for the performance test of components, which are used in the VHTR, and they manufactured a PHE prototype to be tested in the loop. In this study, as part of the high-temperature structural-integrity evaluation of the PHE prototype, which is scheduled to be tested in the gas loop, we carried out high-temperature structural-analysis modeling, thermal analysis, and thermal expansion analysis of the PHE prototype. The results obtained in this study will be used to design the performance test setup for the PHE prototype.

  • PDF

레이저를 이용한 금속액적 적층시 온도분포와 잔류응력 해석 (Analysis of Temperature Distribution and Residual Stress in Deposition Process of Metal Droplet by Using Laser Beam)

  • 윤진오;양영수
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.187-193
    • /
    • 2005
  • The temperature distribution of the deposited droplet was predicted by using the finite element analysis and it was assumed that the droplet was axisymmetrical model. The analysis of residual stress was performed with the temperature data, which is obtained from the result. Axisymmetric droplet is deposited three times to consider the actual phenomenon of droplet deposition. The analysis of the temperature distribution is respectively performed whenever the axisymmetric droplet is laminated and the residual stresses of the laminated axisymmetric droplet are calculated with the value of the temperature distribution.

현장계측 및 수치해석에 의한 장대버팀보의 온도영향 분석 (The Analysis of the Temperature Effects on Long-span Strut by Field Monitoring and Numerical Analysis)

  • 이문주;최성근;신세영;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1468-1475
    • /
    • 2005
  • In this study, the effects of temperature on loading of long-span strut were studied by using field monitoring and numerical analysis. For the field monitoring, several sensors, such as stain gages, temperature gages and load cells, were installed on the struts. From the monitoring results, the relation between temperature and axial force of the struts was analysed. By numerical analysis, the changes of axial force of strut and lateral displacement of wall due to temperature change were described with the strut length and ground conditions.

  • PDF

고온 작동형 전지모듈 온도분포 특성에 관한 수치해석 (Numerical Analysis on the Characteristic of Thermal Distribution for High Temperature Operating Battery Module)

  • 이중섭;이병호
    • 한국기계가공학회지
    • /
    • 제12권5호
    • /
    • pp.102-108
    • /
    • 2013
  • In this study, the experiment result and numerical analysis on temperature distribution of a secondary battery module for high temperature operation type were compared. Because experimental battery has been in danger of explosions, experiment on temperature distribution was carried out using dummy batteries. Study on NAS battery module, which is secondary battery of high temperature operation type, is as follows ; Test result showed that battery's temperature is in steady state uniformly after 8 hours in each section. It is similar to experimental result for temperature distribution from the result of numerical analysis, and it takes about 8.5 hours to the $300^{\circ}C$.

주상용 몰드변압기의 온도분포와 열응력 해석 (The Temperature Distribution and Thermal Stress Analysis of Mold transformer)

  • 조한구;이운용;한세원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2000
  • The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. Therefore design time and design cost are decreased by numerical analysis. In this paper, the temperature distribution and thermal stress analysis of 50kVA pole cast resin transformer for power distribution are investigated by FEM program. The temperature change according to load rates of transformer also have been investigated. We have carried out temperature rise test and test results are compared with simulation data.

  • PDF

구체콘크리트면에 받는 열온도의 시뮬레이션 실험 (The Estimation of Surface Temperature of Concrete Frame Caused by Fire)

  • ;;오상근;정환목;최희용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.272-277
    • /
    • 1997
  • The object of this paper is to analyze the surface temperature of RC structures caused by fire. The experimental analysis is undertaken by using following two methods. 1) Simulation to analyze the relationship between the temperature and the condition change for glass wool caused by fire. 2) Temperature-analysis (TG/DTA tests) of RC structures. From the results of the two experimental analysis, it was possible to estimate the temperature of RC concrete structures caused by fire.

  • PDF

Mechanical analysis for prestressed concrete containment vessels under loss of coolant accident

  • Zhou, Zhen;Wu, Chang;Meng, Shao-ping;Wu, Jing
    • Computers and Concrete
    • /
    • 제14권2호
    • /
    • pp.127-143
    • /
    • 2014
  • LOCA (Loss Of Coolant Accident) is one of the most important utmost accidents for Prestressed Concrete Containment Vessel (PCCV) due to its coupled effect of high temperature and inner pressure. In this paper, heat conduction analysis is used to obtain the LOCA temperature distribution of PCCV. Then the elastic internal force of PCCV under LOCA temperature is analyzed by using both simplified theoretical method and FEM (finite element methods) method. Considering the coupled effect of LOCA temperature, a nonlinear elasto-plasitic analysis is conducted for PCCV under utmost internal pressure considering three failure criteria. Results show that the LOCA temperature distribution is strongly nonlinear along the shell thickness at the early time; the moment result of simplified analysis is well coincident with the one of numerical analysis at weak constraint area; while in the strong constrained area, the value of moments and membrane forces fluctuate dramatically; the simplified and numerical analysis both show that the maximum moment occurs at 6hrs after LOCA.; the strain of PCCV under LOCA temperature is larger than the one of no temperature under elasto-plastic analysis; the LOCA temperature of 6hrs has the greatest influence on the ultimate bearing capacity with 8.43% decrease for failure criteria 1 and 2.65% decrease for failure criteria 3.

염소와 황을 함유한 폐기물의 소각시 생성되는 유해 중금속류 결정에 대한 화학평형 계산 (An Equilibrium Analysis to Determine the Speciation of Metals in the Incineration of Waste Containing Chlorine and Sulfur)

  • 이정진;황정호
    • 한국연소학회지
    • /
    • 제1권1호
    • /
    • pp.31-39
    • /
    • 1996
  • An equilibrium analysis was carried out to determine principal species in the incineration of hazardous waste, which was assumed as a compound of hydrocarbon fuel, chlorine, sulfur, and heavy metals, and their behaviors with variation of temperature, chlorine and sulfur concentrations. Calculated results showed that the most important parameter influencing the principal species was temperature. Chlorine concentration affected on mole fractions of the species, especially at high temperature. Existence of sulfur had a significant effect on the species at low temperature, regardless of surfur concentration. Generally, principal species at high temperature were chlorides and oxides, while the principal species at low temperature were sulfides. As temperature increased, mole fractions of the principal species increased at low temperature, however, mole fractions of some metal species decreased at high temperature.

  • PDF

레이저흡수분광을 이용한 난류유동 배기가스 온도장 실시간 분석 연구 (Real-time Analysis of Exhaust Gas Temperature Field in Turbulent Flow Using Laser Absorption Spectroscopy)

  • 최두원
    • 열처리공학회지
    • /
    • 제37권2호
    • /
    • pp.73-78
    • /
    • 2024
  • This study presents a real-time method that uses Laser Absorption Spectroscopy (LAS) to measure exhaust gas temperatures in turbulent flow fields. It was possible to measure temperature by passing a laser beam through the exhaust gas in a grid pattern, and obtain a temperature distribution image through time series analysis at 0.1 second intervals. Temperature image resolution has been improved with CT reconstruction algorithms. Estimating maximum temperature values and locations enabled 2D temperature analysis, surpassing single-point methods like thermocouples. The accuracy of LAS measurements was evaluated by comparison with thermocouple measurements. This approach will contribute to automotive technology and environmental protection by providing reliable temperature data for interpreting turbulent temperature distributions.

전산 열해석 DB를 이용한 초고온 진공로 최적설계 (Optimal Design of High Temperature Vacuum Furnace Using Thermal Analysis Database)

  • 리진철;박미영;변영환;이창진;이재우
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.594-601
    • /
    • 2006
  • Optimization study has been carried out to design an energy efficient, high temperature vacuum furnace which satisfies users' design requirements. First of all, the transient temperature distribution and the uniform temperature zone results have been compared with the steady state results to validate the feasibility of using steady state solution when constructing the thermal analysis DB. In order to check the accuracy, the interpolated results using thermal analysis DB have been compared with the computational and the experimental results. In this study, total heat flux is selected as the objective function, and the geometry parameters of vacuum furnace including the thickness of insulator, the heat zone sizes and the interval between heater and insulator are the design variables. The Uniform temperature zone sizes and the wall temperature are imposed as the design constraints. With negligible computational cost a high temperature vacuum furnace which has $40\sim60%$ reduction in total heat flux is designed using thermal analysis DB.