• Title/Summary/Keyword: temperature distribution

Search Result 7,488, Processing Time 0.034 seconds

Characteristics of Frost Formed on Heat Exchanger Fins of Non-Uniform Temperature Distribution (불균일한 온도분포를 갖는 열교환기 휜에서의 착상 특성)

  • An, Won-Jun;Kim, Jung-Soo;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.7
    • /
    • pp.373-379
    • /
    • 2009
  • In this study, frosting experiment was conducted to investigate the characteristics of frost formed on heat exchanger fins of non-uniform temperature distribution. Temperature distribution and frost characteristics of a 2-D fin surface were investigated in the airflow direction and the direction perpendicular to airflow. Temperature gradient was very small in the airflow direction, while it was large in the direction perpendicular to airflow due to fin heat conduction. The variations of the frost thickness gradient and the frost density gradient in the direction perpendicular to airflow were significant. On the other hand, the temperature gradient on frost surface in the direction perpendicular to airflow was significant at the early stage of frosting, while it decreased gradually as time elapsed.

CFD ANALYSIS OF DISTRIBUTION OF AIR TEMPERATURE ON PLATFORMS OF A LARGE RAILWAY STATION IN SUMMER SEASON

  • Tsukamoto Kenji;Iino Akinaru;Tominaga Yoshihide
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.173-177
    • /
    • 2005
  • The purpose of this study is to analyze the principal causes of increases in air temperature on platforms of railway station. We analyzed the distribution of air temperature on Shinkansen platforms at Station 'A' using Computational Fluid Dynamics (CFD). We focused on the factors that influence the temperature dynamics associated with heat generated by trains and station buildings and their effect on the ambient temperature on platforms. In the case of heat generated by trains, air temperature on Shinkansen platforms increased by 4 to 7 degrees compared to when trains generated no heat. When a 50-m high station building was located on the windward side of the platforms, air temperature on Platform X was 2 degrees higher than when the station buildings were absent. Air? temperature on platforms VII to IX increased progressively, and the maximum air temperature on platform VIII was 3 K higher than if station buildings were absent.

  • PDF

Spray combustion with high temperature air in a Gas Turbine Combustor (가스터빈 연소기내의 고온공기 분무연소 해석)

  • Jo, Sang-Pil;Kim, Ho-Young;Park, Sim-Soo
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.192-198
    • /
    • 2004
  • A numerical study was conducted to determine the effects of high temperature air, including equivalent ratio on flow field, temperature, evaporation, and overall temperature distribution in gas turbine combustor. A sector model of a typical wall jet can combustor, featuring introduction of primary air and dilution air via wall jet, was used in calculations. Flow field and temperature distribution were analyzed. Operating conditions such as inlet temperature and overall equivalent ratio were varied from 373 to 1300 K, and from 0.3 to 0.6, respectively, while any other operating conditions were fixed. The RNG ${\kappa}-{\varepsilon}$ model and eddy breakup model were used for turbulence and combustion model respectively. It was found that the increase with the inlet air temperature, velocity in the combustor is accelerated and evaporation of liquid fuel is not affected in primary zone, high temperature inlet air enhances the evaporation and improves overall temperature distribution factor.

  • PDF

Effect of Mold Dimensions on Temperature Distribution of Die during Plasma Activated Sintering (플라즈마 활성 소결에 있어서 다이스의 온도분포에 미치는 몰드 크기의 영향)

  • Lee Gil-Geun;Park IK-Min
    • Journal of Powder Materials
    • /
    • v.11 no.5
    • /
    • pp.363-368
    • /
    • 2004
  • In the present study, the focus is on the analysis of the effect of the mold dimensions on the temperature distribution of a die during plasma activated sintering. The temperature distribution of a cylindrical mold with various dimensions was measured using K-type thermocouples. The temperature homogeneity of the die was studied based on the direction and dimensions of the die. A temperature gradient existed in the radial direction of the die during the plasma activated sintering. Also, the magnitude of the temperature gradient was increased with increasing sintering temperature. In the longitudinal direction, however, there was no temperature gradient. The temperature gradient of the die in the radial direction strongly depended on a ratio of die volume to punch area.

Temperature Rise Test and Temperature Distribution Analysis of Pole Mount Mold Transformer with One-body Molding (일체형 주상용 몰드 변압기의 온도분포 및 특성 비교)

  • Cho, Han-Goo;Lee, Un-Yong;Kang, Tack-Sou;Choi, In-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1154-1159
    • /
    • 2006
  • The mold transformers have been widely used in underground substations of large building and have some advantages when compared with oil-transformer. Those advantages are low fire risk, environmental compatibility, compact size and high reliability. The mold transformer is generally known to have cooling duct between low voltage and high voltage coil. To achieve better compact structure and low loss, mold transformers made by one body molding method has been developed. Nevertheless, such kinds of transformer need better cooling method because heat radiation between each winding is still of problem. The life of transformer is significantly dependent on the thermal behavior in windings. Many designers have calculated temperature distribution in transformers and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, the temperature distribution analysis of 100 kVA pole mold transformer for power distribution were investigated by FEM program and the thermal analysis results were compared with temperature rise test.

The Design and Performance Test of Mold Transformer for Outdoor Pole (50 kVA 주상용 몰드변압기의 설계 및 특성평가)

  • Cho, Han-Goo;Lee, Un-Yong;HwangBo, Kuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

Numerical Studies of Cell Temperature Distribution in MCFC Stack According to Electrical Loads (전기 부하에 따른 용융탄산염 연료전지 스택 온도 분포에 관한 수치 해석 연구)

  • Kim, Do-Hyung;Kim, Beom-Joo;Lee, Jung-Hyun;Kang, Seung-Won;Lim, Hee-Chun
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.4
    • /
    • pp.258-263
    • /
    • 2010
  • A numerical stack model has been developed to predict the temperature at a constant-load operation of molten carbonate fuel cell stacks. For the validity of the model, the simulated results with several boundary conditions were compared in the cell temperature data obtained from 75 kW class MCFC stack operation. It was shown that the simulated results with the existing boundary condition, which the stack outlet temperature was fixed at $650^{\circ}C$, didn't match well with the measured data. On the other hand, the stack model with the outlet temperature modified by the outlet manifold temperature measured from the stack under several electric loads was found to explain the measured cell temperature distribution well. The results show that the model can be used to predict the cell temperature distribution in the stacks by the measurement of the manifold outlet temperature.

The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer (주상용 몰드 변압기의 온도분포 해석과 온도상승 시험)

  • Cho, Han-Goo;Kim, Seok-Sou;Lee, Un-Yong;Lee, Jong-Doug
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.245-247
    • /
    • 2001
  • In this paper, the temperature distribution and thermal stress analysis of 50kVA pole mold transformer for power distribution are investigated by FEM program. The temperature rise test of designed mold transformer is carried out and test result is analyzed compare to simulation data.

  • PDF

A study on the temperature distribution measurement of the high pressure mercury lamp (고압 수은등의 온도분포 측정에 대한 연구)

  • 손승현;김상용;김창섭;지철근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.35-40
    • /
    • 1990
  • Temperature distribution of high pressure mercury lamp has been mesured as a function of time using spectroscopic method. Sampling signal which is synchronized by lamp voltage was used to mesure temporal line intensity at each radius. To obtain radial temprature distribution, the mesured intensity was transformed into radial line intensity by Abel's formula. Absolute temperature profile was calculater from relative intensities of spectral lines as a function of line and tube radius. The temperature profile is very similar to the electrical tube current profile.

  • PDF

A study of Heat Transfer by the Finite Element Method - Around Square Heat Source - (유한요소법에 의한 열전달 연구 -4각열원 주위-)

  • 장재은
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.1
    • /
    • pp.26-33
    • /
    • 1998
  • This paper subdivided the interior solid into triangular shape of equal size to calculate the temperature distribution around the square heat source of it, and compared calculated values with measured ones. The result obtained are as follows. 1) It was found that we can calculate the temperature distribution around the square heat source of interior solid by the variational method of the finite element method as the calculated values were almost accord with the measured ones. 2) The temperature distributed were higher when the distances between heat source were farther and lower when those nearer. 3) Vertical surface temperature distribution is remarkably efficient by thermal conductivities.

  • PDF