• Title/Summary/Keyword: teflon filter

Search Result 35, Processing Time 0.025 seconds

Teflon coating of fabric filters for enhancement of high temperature durability (섬유상 여과필터의 고온 내구성 향상을 위한 테프론 코팅 연구)

  • Kim, Eun-Joo;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.232-239
    • /
    • 2011
  • Fabric fibrous filter has been used in various industrial applications owing to the low cost and wide generality. However, the basic properties of fabric materials often limit the practical utilization including hot gas cleaning. This study attempts to find new coatings of porous fibrous filter media in order to overcome its insufficient thermal resistance and durability. Teflon was one of the plausible chemicals to supplement the vulnerability against frequent external thermal impacts. A foaming agent composed of Teflon and some organic additives was tentatively coated on the glass fiber mat. The present test Teflon foam coated filter was fount to be useful for hot gas cleaning, up to $250^{\circ}C$-$300^{\circ}C$. Close examination using XPS(X-ray Photoelectron Spectroscopy) and Contact angle proved the binding interactions between carbon and fluorine, which implies coating stability. The PTFE/Glass foam coated filter consisted of more than 95% (C-F)n bond, and showed super-hydrophobic with good-oleophobic characteristics. The contact angle of liquid droplets on the filter surface enabled to find the filter wet-ability against liquid water or oil.

Effect of Test Board on Insertion Loss of GHz Multilayer LC-Filter (GHz용 적층 LC필터의 삽입손실에 대한 Test Board의 영향)

  • Chun, Myoung-Pyo;Cho, Jung-Ho;Kim, Byung-Ik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.173-175
    • /
    • 2005
  • The effects of PCB Board on the filter characteristics such as insertion loss and transmission characteristics were investigated for the measurement of 5GHz LC filter. Insertion loss measured with PCB Board of Teflon is 0.3 dB lower in comparion with FR-4. The filter characteristics measured in the passband were different from the calculated results. In comparison with the calculated value, the measured value shows that center frequency is 20MHz lower, passband is narrower and insertion loss is larger. The difference of Insertion loss between Teflon and FR-4 increases with increasing measurement frequency.

  • PDF

Filter- and Denuder-Based Organic Carbon Correction for Positive Sampling Artifacts

  • Hwang, InJo;Na, Kwangsam
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.107-113
    • /
    • 2017
  • This study describes (1) the impact of positive sampling artifacts caused by not only a filter-based sampling, but also a denuder-based sampling in the determination of particle-phase organic carbon (POC), (2) the effect of sample flow rate on positive artifacts, and (3) an optimum flow rate that provides a minimized negative sampling artifact for the denuder-based sampling method. To achieve the goals of this study, four different sampling media combinations were employed: (1) Quartz filter-alone (Q-alone), (2) quartz filter behind quartz-fiber filter (QBQ), (3) quartz filter and quartz filter behind Teflon filter (Q-QBT), and (4) quartz filter behind carbon-based denuder (Denuder-Q). The measurement of ambient POC was carried out in an urban area. In addition, to determine gas-phase OC (GOC) removal efficiency of the denuder, a Teflon filter and a quartz filter were deployed upstream and downstream of the denuder, respectively with varying sample flow rates: 5, 10, 20, and 30 LPM. It was found that Q-alone sampling configuration showed a higher POC than QBQ, Q-QBT, and Denuder-Q by 12%, 28%, and 23%, respectively at a sample flow rate of 20 LPM due to no correction for positive artifact caused by adsorption of GOC onto the filter. A lower quantity of GOC was collected from the backup quartz filter on QBQ than that from Q-QBT. This was because GOC was not in equilibrium with that adsorbed on the front quartz filter of QBQ during the sampling period. It is observed that the loss of particle number and mass across the denuder increases with decreasing sample flow rate. The contribution o f positive arti facts to POC decreased with increasing sample flow rate, showing 29%, 25%, and 22% for 10, 20, and 30 LPM, respectively. The 20 LPM turns out to be the optimum sample flow rate for both filter and denuder-based POC sampling.

A Study on the Volatilization of Particulate Nitrate (NO3-) During Fine Particle (PM2.5) Measurement (미세입자(PM2.5) 측정시 발생되는 질산염(NO3-) 휘발에 관한 연구)

  • 강병욱;이학성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.4
    • /
    • pp.297-303
    • /
    • 2002
  • Fine particles (d$_{p}$ < 2.5 $\mu$m) were measured using an annular denuder system (ADS) in Chongju. The data set was collected on fifty-eight different days with a 24-hr sampling period from October 27, 1995 through August 25, 1996. Particulate nitrate in the ADS was also measured on teflon and nylon filters in series behind denuders to collect HNO$_3$, HNO$_2$, SO$_2$and NH$_3$. From this study. the mean concentration of particulate nitrate of PM$_{2.5}$ in the ADS were seen with the following order: winter (5.05) >fall (4.36) >spring (3.92) > summer (1.10 $\mu\textrm{g}$/㎥). Nitrate losses, which calculated from the ratio of nylon filter nitrate to the sum of teflon and nylon filter nitrates, varied in the following manner summer (72.2%) > spring (42.6%) > fall (23.5%)> winter (0.4%). Especially, gaseous nitric acid was dominant at temperature higher than 8$^{\circ}C$ while particulate nitrate was major species in total nitrate below that temperature. This indicates the particulate nitrate loss is strongly correlated rather with ambient temperature.e.e.

New Hairpin Type Bandpass Filter (BPF) (새로운 헤어핀 타입 대역통과필터)

  • 채동규;김동현;임문혁;윤기완
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.457-459
    • /
    • 2003
  • A new hairpin type bandpass fille. (BPF) with novel type of resonators on Teflon substrate is designed, measured, and compared with its simulation results. The proposed filter seems to have advantages of low cost and low loss, thus being very useful for 12 GHz RF applications.

  • PDF

Studies on the Microstrip Bandpass Filter Using Stepped Impedance Resonator and the Wideband Microstrip Bandpass Filter (스텝 임피던스 공진기를 이용한 마이크로스트립 대역통과 필터와 광대역 마이크로스트립 대역통과 필터에 관한 연구)

  • 박봉근;박동철
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.4
    • /
    • pp.10-16
    • /
    • 1991
  • A microstrip bandpass filter using stepped impedance resonators and tapped input / output is realized with Teflon substrate, whose center frequency is 3.5 GHz and fractional bandwidth is 20%. In order to realize a wider bandwidth of 30%, the Crystal's design method and the input / output tapping scheme are used. Another microstrip filter designed as mentioned above is realized with Epsilam-10 substrate. This case shows good agreement between the theoretical responses and the measured ones.

  • PDF

Sampling Method for Individual Particle Analysis of Atmospheric Aerosol (개별입자 분석을 위한 대기에어로졸의 시료채취법)

  • Seong-Woo Cheon;Jeong-Ho Park
    • Journal of Environmental Science International
    • /
    • v.33 no.2
    • /
    • pp.113-119
    • /
    • 2024
  • In this study, the most suitable sampling methods for the bimodal mass distribution characteristics and individual particle analysis of atmospheric aerosols were investigated. Samples collected in Quartz, Teflon, and Nuclepore filters were analyzed for individual particles using scanning electron microscopy with an energy-dispersive X-ray spectrometer (SEM/EDS). Then, the pore diameter of the filter and the collection flow rate were determined using the theoretical collection efficiency calculation formula for two-stage separation sample collection of coarse and fine particles. The Nuclepore filter was found to be the most suitable filter for identifying the physical and chemical characteristics of atmospheric aerosols since it was able to separate the sample and count the different sized particles better than either Quartz or Teflon. Nuclepore filters with 8.0 ㎛ and 0.4 ㎛ pores were connected in series and exposed to a flow rate of 16.7 L/min for two-stage separation sampling. The results show that it is possible to separate and collect both coarse and fine particles. We expect that the proposed methodology will be used for future individual particle analysis of atmospheric aerosols and related research.

Quantification of Sampling Artifacts in PM2.5 Inorganic Ion Species using Teflon Filter (테플론 여과지를 이용한 미세입자 무기이온 성분 측정에서의 오차 정량)

  • Kim, Jung-Youn;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.1
    • /
    • pp.74-83
    • /
    • 2007
  • Artifacts due to inter-particle and gas-particle interactions during PM2.5 sampling were quantified by comparing the measurement results between the annular denuder-filterpack system and the filterpack system without denuder. Measurements were carried in Seoul for 10 days in each season; Nov. 2004, Jan. 2005, Mar. 2005, and Jul. 2005, respectively. In each day, two 12-h samples were obtained. The concentrations of nitrate and chloride showed seasonal variations mainly due to the availability of ammonium to neutralize nitrate or chloride. Nitrates and chloride losses were prominent in summer. Since most of ammonia was used to neutralize sulfuric acid and formed ammonium sulfate in summer, nitrate and chloride could not exist in particles and ammonium loss was smaller than other seasons.

Characteristics of Nitrate (NO3-) Volatilization from Fine Particles (PM2.5) at 4 Measurement Sites in Seoul (미세입자(PM2.5)의 질산염 (NO3-) 휘발 특성 분석 -서울시 4개 측정지역을 중심으로-)

  • Kim, Yoo-Jung;Jung, Sung-Woon;Kang, Choong-Min;Ma, Young-Il;Kim, Su-Hyang;Woo, Jung-Hun;SunWoo, Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.613-621
    • /
    • 2008
  • The purpose of this study is to understand the impact that temperature and relative humidity have on the volatilization loss of particulate nitrate $(NO_3^-)$ from Teflon filters during measurements of ambient fine particles $(PM_{2.5})$. Fine particles $(d_p<2.5{\mu}m)$ were measured using an annular denuder system (ADS) at four representive areas in Seoul. The measurements were made during 28 different days at 24-hr sampling intervals from February 14 to October 15, 1997. In this study, nitrate losses. calculated by the ratio of nitrate on the nylon filter to their sum in both Teflon and nylon titters, varied seasonally in the following order: summer (45.5%) > spring (23.8%) > fall (20.6%) > winter (19.7%). The results showed strong correlations with temperature, but we did not observe any significant effects of relative humidity. However, we observed that both temperature and relative humidity influenced the ambient gas/particle nitrate ratio in a different case study using a denuder.