• 제목/요약/키워드: technology evaluation

Search Result 16,935, Processing Time 0.043 seconds

Quality Characteristics of Red Pepper Paste (Capsicum annuum L.) Added with Garlic during Aging (마늘 첨가 홍고추 페이스트의 숙성 중 품질특성 변화)

  • Hwang, In Guk;Shin, Young Jee;Lee, Junsoo;Jeong, Heon Sang;Kim, Hae Young;Yoo, Seon Mi
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.12
    • /
    • pp.1778-1784
    • /
    • 2012
  • This study was conducted to investigate the quality characteristics of red pepper paste (RPP) added with garlic during aging at $10^{\circ}C$ for 56 days. RPP was evaluated for pH, acidity, free sugar contents, Hunter's color values, flavor patterns, and sensory characteristics. The initial pH and acidity of the RPP with garlic were 5.07~5.18 and 0.33~0.35%, respectively. The pH of RPP increased as the amount of garlic added increased, whereas the acidity decreased. The pH and total acidity changed gradually until day 28, after which they changed rapidly. The initial fructose and glucose contents of the RPP with garlic decreased to 2.32~2.41% and 1.94~2.09%, respectively. The fructose and glucose contents further decreased gradually to 1.81~1.94% and 1.54~1.71%, respectively, during aging. The Hunter's L- and b-values of the RPP increased, whereas the a-value decreased as the amount of garlic added increased. The flavor patterns of the RPP with garlic noticeably differed from those of the control RPP during aging. Sensory evaluation indicated that garlic could enhance the overall flavor characteristics of RPP.

Nutrition Components and Physicochemical Properties of Acer termentosum Maxim. Leaf (벌나무 잎의 영양성분 및 이화학 특성)

  • Park, Sung Jin;Shin, Eon Hwan;Kim, Dong Ho;Rha, Young-Ah
    • Culinary science and hospitality research
    • /
    • v.22 no.8
    • /
    • pp.27-38
    • /
    • 2016
  • This study examined the nutrient components and physicochemical properties of Acer termentosum Maxim. leaf as a natural health food source. To accomplish this purpose, the general and antioxidative contents of Acer termentosum Maxim leaf were measured. Total contents of carbohydrates, crude protein, crude lipid, and ash were 53.6%, 24.3%, 3.5%, and 3.5%, respectively. Caloric content of Acer termentosum Maxim was 246.5 kcal, while total dietary fiber was 46.7%. Regarding mineral contents, K was the most abundant mineral, followed by Ca, Mg, and P. Therefore, Acer termentosum Maxim is an alkali material. Total phenol contents of the 70% ethanolic extracts of Acer termentosum Maxim was $116.35{\pm}1.4mg\;GAE/g$. Total flavonoid contents of the 70% ethanolic extracts were $20.3{\pm}1.23mg\;RE/g$. The antioxidative activities of Acer termentosum Maxim. were significantly increased in a dose dependent manner on DPPH(1,1-Diphenyl-2-picrylhydrazyl) radical scavenging, ABTS (2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt) radical scavenging, FRAP (ferric reducing antioxidant power) activity, reducing power. It is expected that follow up study of Acer termentosum Maxim through developing processed food and evaluation of their functional properties would provide useful information as a source of functional foods.

A Study on Difficulty Factors of Youth Startups for Activating Local Startups (지역창업 활성화를 위한 청년창업 애로 요인에 관한 연구)

  • Ahn, Tae-Uk;Kang, Tae-Won
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.15 no.2
    • /
    • pp.67-80
    • /
    • 2020
  • This study has been conducted at a time when Korean government continues to extend support for youth startups as part of its policy to create jobs and the focus moves from career and employment to youth startups with a growing interest in the field of youth startups. Against this background, this study aims to identify difficulty factors of youth startups in areas besides the Seoul Metropolitan Area, seek ways to overcome difficulty factors, and propose policy implications. To this end, this study set five criteria and 25 sub-criteria to evaluate the difficulties of youth startups by reviewing previous studies and conducting literature review, and performing brainstorming method. The empirical analysis of the evaluation criteria was performed, using the analytic hierarchy process (AHP) method, on youths aged 19 to 39 in Gunsan area. The analysis results showed that the largest difficulty factors facing local youths include business model establishment, business administration and management, and startup funding in the criteria. As for sub-criteria, the largest difficulty factors are market information acquisition, technology commercialization, project feasibility, technology development, and new market pioneering in descending order. Local youths have much difficulty about the process of turning a business item into a product and commercializing it. According to a comparative analysis by gender, men were a relatively high difficulty in commercializing business models than women. men were a relatively high difficulty in commercializing business models than women. On the other hand, women were higher than men in all factors (management management, entrepreneurship, improvement of entrepreneurship system, and improvement of entrepreneurship awareness) except for factors affecting business model. In addition, the factors of entrepreneurship were found to be relatively different among young people (college students, prospective entrepreneurs, entrepreneurs). In conclusion, it was suggested that in order to revitalize youth entrepreneurship in the region, it is necessary to actively resolve the difficulties of business model commercialization rather than entrepreneurship funds. In addition, it is necessary to strategically support customized entrepreneurship support and situational administrative services because gender and hierarchical difficulties are different than general solutions. This study presented practical priorities and derivation methods for the entrepreneurship difficulties faced by local youth, and suggested measures and improvements for vitalizing local youth entrepreneurship in the future.

Using CR System at the Department of Radiation Oncology PACS Evaluation (방사선 종양학과에서 CR System을 이용한 PACS 유용성 평가)

  • Hong, Seung-Il;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.143-149
    • /
    • 2012
  • Today each hospital is trend that change rapidly by up to date, digitization and introducing newest medical treatment equipment. So, we introduce new CR system and supplement film system's shortcoming and PACS, EMR, RTP system's network that is using in hospital harmoniously and accomplish quality improvement of medical treatment and service elevation about business efficiency enlargement and patient Accordingly, we wish to introduce our case that integrate reflex that happen with radiation oncology here upon to PACS using CR system and estimate the availability. We measured that is Gantry, Collimator Star Shot, Light vs. Radiation, HDR QA(Dwell position accuracy) with Medical LINAC(MEVATRON-MX) Then, PACS was implemented on the digital images on the monitor that can be confirmed through the QA. Also, for cooperation with OCS system that is using from present source and impose code that need in treatment in each treatment, did so that Order that connect to network, input to CR may appear, did so that can solve support data mistake (active Pinacle's case supports DICOM3 file from present source but PACS does not support DICOM3 files.) of Pinacle and PACS that is Planning System and look at Planning premier in PACS. All image and data constructed integration to PACS as can refer and conduct premier in Hospital anywhere using CR system. Use Dosimetry IP in Filmless environment and QA's trial such as Light/Radition field size correspondence, gantry rotation axis' accuracy, collimator rotation axis' accuracy, brachy therapy's Dwell position check is available. Business efficiency by decrease and so on of unnecessary human strength consumption was augmented accordingly with session shortening as that integrate premier that is neted with radiation oncology using CR system to PACS. and for the future patient information security is essential.

Research status of the development of genetically modified papaya (Carica papaya L.) and its biosafety assessment (GM 파파야 개발 및 생물안전성 평가 연구 동향)

  • Kim, Ho Bang;Lee, Yi;Kim, Chang-Gi
    • Journal of Plant Biotechnology
    • /
    • v.45 no.3
    • /
    • pp.171-182
    • /
    • 2018
  • Papaya (Carica papaya L.) is one of the crops widely planted in tropical and subtropical areas. The papaya fruit has low calories and are plentiful in vitamins A and C and in minerals. A major problem in papaya production is a plant disease caused by the papaya ringspot virus (PRSV). The first PRSV-resistant GM papaya expressing a PRSV coat protein gene was developed by USA scientists in 1992. The first commercial GM papaya cultivars derived from the event was approved by the US government in 1997. Development of transgenic papayas has been focused on vaccine production and limited agricultural traits, including insect and pathogen resistance, long shelf life, and aluminum and herbicide tolerance. Approximately 17 countries, including the USA and China, produced transgenic papayas and/or commercialized them, which provoked studies on biosafety assessment and development of GM-detection technologies. For the biosafety assessment of potential effects on human health, effects of long-term feeding to model animals have been studied in terms of toxicity and allergenicity. Studies on environmental safety assessment include influence on soil-microbial biodiversity and transfer to soil bacteria of GM selection markers. Many countries, such as Korea, the European Union, and Japan, that have strict regulations for GM crops have serious concerns about unintended introduction of GM cultivars and food commodities using unauthorized GM crops. Transgene- and/or GM event-specific molecular markers and technologies for genomics-based detection of unauthorized GM papaya have been developed and have resulted in the robust detection of GM papayas.

Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan (동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가)

  • Lee, Jaesang;Lee, Kyuchan;Lee, Seunghwan;Bae, Seongbok;Park, Jongyeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Purpose Dynamic kidney scan is a typical imaging technique that visualizes kidney function. Reproducibility of dynamic kidney scans has been evaluated by comparing low-dose kidney scans with low-dose radiopharmaceutical and standard dynamic kidney scan. With this comparative study, if reproducibility is superb, the dynamic kidney scan method with reduced radioactivity to patients is to be utilized and radiation exposure to patient is to be reduced. Materials and Methods For gamma camera, Orbiter, SymbiaE (Siemens, Germany) was used. Among patients who had used 370 Mbq (10 mCi) from January of 2013 to February 2014 and other patients who had used 185 Mbq (5 mCi) from March of 2014 to July of 2015 with identical condition, 21 subjects using DTPA and 20 subjects using $MAG_3$, 41 subjects in total, had been selected as subjects for data. From renogram of the result image, frame of the peak point was selected. Then, region of interest of kidney and background had been selected and Kidney to Background Ratio has been calculated for comparison. Results In tests using DTPA, kidney to background ratio when using 370 Mbq was $5.67{\pm}0.8$ at average while it was $5.62{\pm}0.87$ when using 185 Mbq, which didn't show much difference. Also in the tests using $MAG_3$, kidney to background ratio when using 370 Mbq was $14.95{\pm}2.58$ at average and $14.56{\pm}2.02$ in 185 Mbq, which neither showed much difference. In paired sample t-test, p-value was 0.566 in DTPA and 0.363 in $MAG_3$, which confirmed that there was no difference between the groups. Conclusion In identical patients, when dose was decreased from 370 Mbq to 185 Mbq, reproducibility of dynamic kidney scan was proven to be excellent. Low-dose Dynamic kidney scan can achieve results with fine reproducibility without improvement in performance of gamma camera and is expected to reduce radiation exposure to patient.

  • PDF

Study on the Usefulness about Molecular Breast Imaging In Dense Breast (치밀형 유방에서 Molecular Breast Imaging 검사의 유용성에 관한 고찰)

  • Baek, Song Ee;Kang, Chun Goo;Lee, Han Wool;Park, Min Soo;Choi, Young Sook;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • Purpose Mammography is the most widely used scan for the early diagnosis since it is possible to observe the anatomy of the breast. however, The sensitivity is markedly reduced in high-risk patients with dense breast. Molecular Breast Imaging (MBI) sacn is possible to get the high resolution functional imaging, and This new neclear medicine technique get the more improved diagnostic information through It is useful for confirmation of tumor's location in dense breast. The purpose of this study is to evaluate the usefulness of MBI for tumor diagnosis in patients with dense breast. Materials and Methods We investigated 10 patients female breast cancer with dense breast type who had visited the hospital from September 1st to Octorber 10th, 2015. The patients underwent both MBI and Mammography. MBI (Discovery 750B; General Electric Healthcare, USA) scan was 99mTc-MIBI injected with 20 mCi on the opposite side of the arm with the lesions, after 20 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. Mammography was also conducted in the same posture. MBI and Mammography images were compared to evaluate the sensitivity and specificity of each case utilizing both image and two images in blind tests. Results The results of the blind test for breast cancer showed that the sensitivity of Mammography, MBI scan was 63%, 89%, respectively, and that their specificity was 38%, 87%, respectively. Using both the Mammography and MBI scan was Sensitivity 92%, specificity 90%. Conclusion This research has found that, The tumor of dense tissue that can not easily distinguishable in Mammography is possible to more accurate diagnosis since It is easy to visually evaluation. But MBI sacn has difficulty imaging microcalcificatons, If used in conjunction with mammography it is thought to give provide more diagnostic information.

  • PDF

The Evaluation of External Radiation Exposure dose rate for Radium-223 Dichloride (Radium-223 Dichloride의 외부 방사선량의 평가)

  • Cho, Seong Wook;Yoon, Seok Hwan;Seung, Jong Min;Kim, Tae Yub;Im, Jeong Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.28-31
    • /
    • 2016
  • Purpose $^{223}Ra-Dichloride$ is used for the medicine of castration-resistant prostate cancer (CRPC) and which emits ${\alpha}-ray$ of 28 Mev that is used for therapy. However $^{223}Ra-Dichloride$ emits ${\beta}-ray$ of 3.6% and ${\gamma}-ray$ of 1.1%(80,156,270 keV) aside from ${\alpha}-ray$ in decay. Therefore we would like to evaluate external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$. Materials and Methods We calculated external radiation expose dose rate using ${\gamma}-constant$ of $^{223}Ra-Dichloride$, $^{99m}Tc$ based on Health physics(2012). $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq were applied. external radiation expose dose rate 15 times from 1m by survey meter. Results ${\gamma}-contant$ of $^{223}Ra$, $^{99m}Tc-MDP$ from 1m distance based on Health physics(2012) is 0.0469, 0.0215. calculated value of external radiation expose dose rate was $16{\mu}Sy$, $34{\mu}Sy$ which activity is $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq from 1 m and measured mean value of 1 m was $0.7{\mu}Sy/h$, $18{\mu}Sy/h$. Conclusion ${\gamma}-constant$ of $^{223}Ra$ is higher than $^{99m}Tc$ based on Health physics(2012). however calculated maximum external radiation expose dose rate of $^{223}Ra-Dichloride$ is lower than $^{99m}Tc$ due to actually used quantity of activity of $^{223}Ra-Dichloride$ is small. measured value of $^{223}Ra-Dichloride$ is also lower than $^{99m}Tc-MDP$. Therefore external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$ is very low.

  • PDF

Usefulness of CTAC Shift Revision Method of Artifact by Diaphragm in PET/CT (PET/CT 검사에서 횡격막에 의한 인공물의 CTAC Shift 보정방법의 유용성)

  • Ham, Jun Cheol;Kang, Chun Koo;Cho, Seok Won;Bahn, Young Kag;Lee, Seung Jae;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.71-75
    • /
    • 2013
  • Purpose: Currently, decrement revision using LDCT is used in PET/CT. But cold artifacts are often found in decrement revision image by mismatch between LDCT image and Emission image near diaphragm due to patient's respiration. This research studied reduction of cold artifact by patient's respiration using CTAC Shift among revision methods. Materials and Methods: From March to September in 2012, 30 patients who had cold artifacts by respiration were targeted using PET/CT Discovery 600 (GE Healthcare, MI, USA) equipment. Patients with cold artifacts were additionally scan in diaphragm area, and the image shown cold artifacts at whole body test were revised using CTAC Shift. Cold artifacts including image, additional scan image and CTAC Shift revision image were evaluated as 1~5 points with naked eye by one nuclear medicine expert, 4 radiotechnologists with over 5 year experience. Also, standard uptake value of 3 images was compared using paired t-test. Results: Additional scan image and CTAC Shift revision image received relatively higher score in naked eye evaluation than cold artifacts including image. The additional scan image and CTAC Shift revision image had high correlation as the results of ANOVA test of standard uptake value and did not show significant difference. Conclusion: When cold artifacts are appeared by patient's respiration at PET/CT, it causes not only patient inconvenience but troubles in test schedule due to extra radiation exposure and time consumption by additional scan. But if CTAC Shift revision image can be acquired with out additional scan, it is considered to be helped in exact diagnosis without unnecessary extra radiation exposure and additional scan.

  • PDF

Establishment of Reference Range of Proinsulin (Proinsulin 참고치 설정에 관한 연구)

  • Nam, Yee Moon;Shin, Yong Hwan;Kim, Ji Young;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.76-79
    • /
    • 2013
  • Purpose: It is very important to establish the appropriate reference range in the laboratory for preventing mistakes like false positive or false negative. Because the reference range in the laboratory is standard of patient test results interpretation. Proinsulin is precursor hormone of insulin, and the importance is increasing for diagnosing diabetes or insulinoma. Proinsulin reagent used in our laboratory is produced in the USA, and the reference range provided by manufacturer was adapted to our reference range after the validation test. But, it is generally recommend for the every laboratory to establish the their own reference range. So, we decided to re-evaluate the reference range with our patients' test results. Materials and Methods: Among 737 patients who had been to health promotion center in our hospital between Dec. $8^{th}$ 2011 and Dec. $21^{st}$ 2011, 563 patients are chosen with exception of diabetics patients and patients showing abnormal test results in Fasting Glucose, HbA1c, Insulin, and C-peptide. The 563 test results (275 males and 288 females) were classified with three groups(entire, male, female), and analysis of normal distribution was performed with aid of SPSS(version 19.0). Because Each group didn't show normal distribution, the reference range was set from the lowest limit of 2.5% to the highest limit of 97.5% with Percentile method used in non-normal distribution. Results: When evaluation values are sorted in ascending order, the entire range is 4.5~52.0 pM and 5.3~51.9 pM for male and 4.5~52.0 pM for female. The calculated reference range with percentile method shows 6.7~26.5 pM for entire group, 6.8~26.5 pM for male and 6.7~26.5 pM for female, respectively. Conclusion: The reference range provided by reagent manufacturer is 6.4~9.4 pM and the one established in this study is 6.7~26.5 pM. This difference might be caused by racial characteristics between Western people and Koreans. So an ideal reference range can be gotten with normal population visiting to every hospital. Our hospital has been using the newly re-establishing reference range under consultation with the department of endocrinology since Aug. $1^{st}$ 2012.

  • PDF