• Title/Summary/Keyword: technology

Search Result 272,404, Processing Time 0.238 seconds

The Comparison of Knee Joint Displaying between The Anteroposterior Weight Bearing View and the Metatarsophalangeal View with Osteoarthritis Patients (골관절염 환자의 촬영방법에 대한 고찰 : AP-WB(Weight-bearing AP), MTP(semiflexed) 촬영법의 비교 고찰을 중심으로)

  • Jeon, Ju-Seob;Park, Hwan-Sang;Moon, Il-Bong;Moon, Ju-Wan;Choi, Nam-Kil;Kim, Chang-Bok;Eun, Sung-Jong
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • Objective : The aim of this study was to compare the knee joint displaying between the anteroposterior weight bearing(AP-WB) View and the metatarsophalangeal(MTP) view for assessing joint space narrowing(JSN) and osteophytes in osteoarthritis patients. Subjects and Materials : Two hundreds of twenty patients(38 men) who came rheumatoid caused by knee pain, had both AP-WB and MTP views taken on a day. Radiographs were evaluated independently by 13 experienced observers(3 orthopedics surgeon, 2 rheumatogist, 3 radiologist, 5 radiological technologist) They assessed JSN and osteophytes using by PACS monitor JSN was scored by the optic evaluation to the nearest at the narrowest point in medial compartments of the tibiofemoral joint in both knees. Osteophytes were graded 0 to 3(bad 0, not bad 1, good 2 and very good 3) according to a standard atlas. All exam was using by Philips(Buckey Diagnostic-TH) X-ray material. Exposure condition was 60 kv, 8 mAs and 100 cm focus to film distance. Results : JSN was scored $1.32{\pm}0.050$ in AP-WB view, $2.51{\pm}0.046$ in MTP view. MTP view of JSN score is higher to AP-WB view significantly(p<0.05). Osteophytes scored $2.14{\pm}0.054$ in AP-WB view, $2.10{\pm}0.054$ in MTP view. There was no difference(p<0.05) between MTP view and AP-WB view in osteophytes. But MTP view was more reproducible than AP-WB view Conclusions : Joint space narrowing is most important factor to diagnosis with knee joint Osteoarthritis patients. This study was summarized as follows; In comparision of JSN, MTP view was more widely displayed than AP-WB view. In comparision of Osteophytes, there was no difference between MTP view and AP-WB view. It was concluded MTP view was more useful method to diagnosis of knee joint Osteoarthritis patients.

  • PDF

Effects of the mascara and eye shadow on theMR image distortion (자기공명영상 왜곡에서 마스카라와 아이섀도의 영향)

  • Lee, Hyun-Yong;Shin, Oun-Jae;Park, Byung-Rae
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.25-32
    • /
    • 2005
  • Purpose : To evaluate the degree of the artifact which is caused by the mascara and the eye shadow when acquiring MR images and compare the difference of the image distortion according to the change of various pulse sequence. Material and Method : The popular domestic mascara and eye shadow products were selected from three different companies respectively and divided into two groups mascara (M1, M2, M3 ), eye shadow (E1, E2, E3). Self-designed quadrature type saddle coil which has 4 cm inside diameter, 8 cm length and which is for both Tx and Rx was used. MR image was acquired respectively after applying the mascara to the tape from study 1, the eye shadow to the tape from study 2 and adding the eye shadow to the mascara from study 3. The FSE(fast spin echo), the SE(spin echo), the GE(gradient echo) were used as pulse sequences. The degree of the image distortion which was measured from each sequence was analyzed in quality and quantity. Result : The mascara and the eye shadow caused the artifacts to the MR images partially and induced the image distortion. There was a little difference in terms of the degree of artifact according to the change of pulse sequence. From the study 3 in which the eye shadow was applied to the mascara, on the axial plane image, the width of artifact was 16.73 mm in the GE pulse sequence, 6.64 mm in the SE pulse sequence, and 6.19 mm in the FSE pulse sequence. The degree of the artifact appeared highly in order of the GE, the SE and the FSE. On the sagittal plane image, the length of artifact was 22.84 mm in the GE, 17.81 mm in the SE and it appeared highly with the SE and the FSE technique order. Conclusion : When examining the eyeball and the brain of a woman with the mascara and the eye shadow, we have to consider that the artifact caused by them can have an effect on the image diagnosis. We concluded that it is more suitable for a brain and a eyeball T2 emphasizing image to use the FSE technique than the GE technique.

  • PDF

Direct foreign investment Korean firms:The case of Samsung Group (한국 기업의 해외직접투자:삼성그룹을 사례로)

  • Lee, Deog-An
    • Journal of the Korean Geographical Society
    • /
    • v.28 no.4
    • /
    • pp.379-391
    • /
    • 1993
  • Present-day world economy is characterized by : technology nationalism, economic regionalism, market protectionism, multinational corporations, efc. All nations are striving for intensifying national economic rivalry and seeking after their own interests above everything else. Many regions of the world are also forming trading blocs, which could negatively affect nonmember states. The ultimate way to meet these difficulties is to establish production facilities in the countries imposing trade regulations. However, as the existing models of direct forrign investment (DFI) do not account for the particular nature of Korean firm's DFI activities, a new point of departure is imperative. It is because of this that Korean firms have only limited firm-specific advantages, the basic precondition of extant DFI theories, compared with their developed counterparts.

  • PDF

Fermentation Characteristics of Yakju Added with Acanthopanacis cortex Extract (오가피 추출액 첨가 약주의 발효특성)

  • Kim, In-Ho;Kim, Seong-Ho;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.4
    • /
    • pp.521-527
    • /
    • 2008
  • Acanthopanacis cortex extracts added Yakju was manufactured and then fermentation and quality characteristics of Yakju were examined. Acanthopanacis cortex extracts added Yakju showed totally similar characteristics with the non-extract added Yakju of control groups. The pH showed almost no change to pH 4.0 after 6 days of fermentation and it was decreased only once in only fermentation time of 3 days. The acidity of Acanthopanacis cortex extracts added group showed no difference to the control group. The sugar obrix and reducing sugar content showed decrease in all two groups in the initial fermentation stage; however, it showed slow decrease as the late fermentation stage. The Acanthopanacis cortex extracts added Yakju showed less alcohol content than the control group in the initial fermentation stage. However, after 6 days of fermentation, the Acanthopanacis cortex extracts added Yakju showed more alcohol contents and constant increase till the final fermentation day. The pH, acidity, reducing sugar and alcohol content showed rapid changes between fermentation days 0 through 3. Therefore, it means that the Acanthopanacis cortex extracts added Yakju fermentation actively takes place between the days 0 through 3. Organic acids detected in Yakju were acetic, lactic, oxalic, malic and succinic acids. The acetic acid was the highest among the total acid contents. Eleutheroside E and chlorogenic acid, known as the effective components of Acanthopanacis cortex, showed stable status without changes in component content till stage two fermentation. The contents of eleutheroside E and chlorogenic acid were $7.61\pm0.39{\mu}g/mL$ and $3.63\pm0.18{\mu}g/mL$ on the final fermentation day, respectively. The fusel oil was slightly detected in both groups with values of $0.08\pm0.001{\sim}0.86\pm0.03mg%$ in n-propyl alcohol, isobutyl alcohol and isoamyl alcohol content. The Acanthopanacis cortex extracts added group was similar to the control group in the overall sensory test.

A Study on Operation Strategy by Multi-variate Regression of Deagu Arboretum Visitor's Satisfaction (대구수목원 이용객 만족모델을 통한 운영 방안 연구)

  • Kang, Kee-Rae
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.1
    • /
    • pp.36-45
    • /
    • 2012
  • Education on the environment and plants offered by arboretum for today's people not only contribute to foster a better natural environment in urban region but also provide visitors with decent refreshment environment and beyond. In the study, the author undertook the observation on usage behavior and satisfaction model of arboretum visitors expect and investigated the facilities and programs to be offered by arboretum in order to propose the opinion regarding the service. For observation size of variables in a multiple regression analysis of variables is influencing satisfaction rankings walks the line of flow, the educational effect on the environment, cleanliness of the facility, visits pay, natural beauty, diversity of trees, accessibility and friendliness of staff, expansion of facilities in the arboretum and appeared as a complement. In case of visitor attribute, the residents living near the facility showed the highest visit frequency of more than 5 times, especially as part of taking a walk. This proves that the visit to arboretum is considered as part of everyday life, and thus a new program and walk path as well as movement route are needed to be developed for the visitors. In the question relating to the facilities and operation programs in Daegu Arboretum, particularly the requests by visitors, they responded that the establishment of cultural event, beautiful natural scenery, refreshment and convenience facilities is the most critical issue. In addition, the management on withered trees and bare lands is an urgent issue as well. In this sense, the Operation and Management Strategies based upon the visitor behaviors and model of satisfaction are needed to deal with the adoption of diverse events and festivals joined by local residents, ombudsman program, environmental program development for students and teachers within the region, negligent bare lands and withered tree replacement, and cafeteria facility improvement and supplement as well as the bench marking of other facilities than arboretums located in other regions. These items are thought to be sufficiently dealt with by Daegu Arboretum having no more external resources. It is recognized that the visitor satisfaction begins from a minor thing, and a small difference determines a great satisfaction, and thus the software approach rather than hardware one is in need.

The Study for Breast Lymphoscintigraphy of Sentinal Lymph Node in breast cancer (유방암환자 전초림프절의 유방 림프신티그라피에 관한 연구)

  • Kim, Hwa-Gon;Kim, Chang-Soo;Kim, Myung-Jun
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2006
  • In the past, most patient of breast cancer suffered side effects due to the useless removement of Axillary Lymph Node, but there is no need to remove it because of the result in this study. The purpose of this study is to save surgery time and side effects after surgical operation for patients with breast cancer by making decisions of operation range for metastasis in first Stenosis Lymph Node using the $^{99m}Tc-Tincolloid$ Scintigraphy and the Micro Probe for radioisotope. As a result of this study, 15 among 20 patients became objects of this study could reduced side effects for operation because there were no axillary lymph node operations. However there is no standard for method of this treatment. It should be standardize where inject point is, how much $^{99m}Tc-Tincolloid$ should be injected(radioactivity value), and the need of massage and Lymph Scintigraphy. Nevertheless I think that this result of study is useful to reduce suffering and side effects from breast cancer and also we should try to do that continuously. The objects for this study were 20 patients diagnosed as breast cancer by Ultrasonography, Mammography & Biopsy. The average of patient age was 45.4 years and its range was between 31 and 71 years. In case of clinical period there were 9 patients of Period I and II patients of Period III. The equipment for this study were $^{99m}Tc-Tincolloid$ describing the Stenosis Lymph Node as a tracer, Micro Probe : Neoprobe 2000(the rest is Gamma Probe) tracing the location, and MS-II Gamma Camera : SIEMENS(the rest is MS-II Gamma Camera) describing the images. There were 3 methods for this study, after selecting one of those methods all 20 patients were performed Stenosis Lymph Node diagnosis & Gamma Probe in operation room. The result was that I imaged all the 20 patients, and seek the Stenosis Lymph Node by using Gamma Probe. Metastasis in Stenosis Lymph Node was 5 and Metastasis in Axillary Lymph Node was 3 between Metastasis in Stenosis Lymph Node cases. Finally 15 patients were also proved that Axillary Lymph Node was Positive and that means there was no Metastasis in Axillary Lymph Node.

  • PDF

Measurement of shoulder motion fraction and motion ratio (견관절 운동 분율의 측정)

  • Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.57-62
    • /
    • 2006
  • Purpose : This study was to understand about the measurement of shoulder motion fraction and motion ratio. We proposed the radiological criterior of glenohumeral and scapulothoracic movement ratio. Materials and Methods : We measured the motion fraction of the glenohumeral and scapulothoracic movement using CR(computed radiological system) of arm elevation at neutral, 90 degree, full elevation. Central ray was $15^{\circ},\;19^{\circ},\;22^{\circ}$ to the cephald for the parallel scapular spine, and the tilting of torso was external oblique $40^{\circ},\;36^{\circ},\;22^{\circ}$ for perpendicular to glenohumeral surface. Healthful donor of 100 was divided 5 groups by age(20, 30, 40, 50, 60). The angle of glenohumeral motion and scapulothoracic motion could be taken from gross arm angle and radiological arm angle. We acquired 3 images at neutral, $90^{\circ}$ and full elevation position and measured radiographic angle of glenoheumeral, scapulothoracic movement respectively. Results : While the arm elevation was $90^{\circ}$, the shoulder motion fraction was 1.22(M), 1.70(W) in right arm and 1.31, 1.54 in left. In full elevation, Right arm fraction was 1.63, 1.84, and left was 1.57, 1.32. In right dominant arm(78%), $90^{\circ} and Full motion fraction was 1.58, 1.43, in left(22%) 1.82, 1.94. In generation 20, $90^{\circ} and Full motion fraction was 1.56, 1.52, 30' was 1.82, 1.43, 40' was 1.23, 1.16, 50' was 1.80, 1.28, 60' was 1.24, 1.75. There was not significantly by gender, dominant arm and age. Conclusion : The criterior of motion fraction was useful reference for clinical dignosis the shoulder instability.

  • PDF

Ultrasonography findings on thyroid nodule with no clinical symptom (임상적 증상이 없는 갑상선 결절에 대한 초음파영상 소견)

  • Kim, Wha-Sun
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.211-217
    • /
    • 2005
  • This study obtained the following conclusions by analyzing whether or not thyroid nodule, the number of nodules depending on age and gender, and the developed site of nodule, targeting 838 persons in their 30s-70s who were conducted the thyroid ultrasonography, without clinical symptoms, at the Health Promotion Center. 1. As for the general characteristics of 838 research subjects, men were 368 persons(44%), and women were 470 persons (56%), and the mean age was 51. 2. Among 838 whole subjects, a case, which was diagnosed to be normal, was 590 persons(70%), and persons with nodules findings were 248 persons (30%), thus it was indicated 30% on an average in having the thyroid nodules findings. 3. As for the frequency by age level in thyroid nodule, it was represented men with 10%-14% and women with $20{\sim}29%$ in their $30{\sim}40s$, and men with $27{\sim}33%$ and women with 37-52% in their 50-60s, and men with 46% and women with 50% in their 70s. 4. As a result of obtaining 248 persons, who have thyroid nodules findings, with the solitary nodule and the multiple nodule, it was indicated the solitary nodule of 50.5% with 125 persons and the multiple nodule of 49.5%, thereby representing the almost same ratio. 5. As for the size of thyroid nodule, the majority in all the age levels had the nodule in small size, and the size of $1{\sim}10\;mm$ was largest with 187 persons (75%) among 248 persons with abnormal findings, and it was 45 persons (18%) in $11{\sim}20\;mm$, 14 persons (5.6%) in $21{\sim}30\;mm$, and 2 persons in more than 31 mm. 6. As for the anatomically developed site in nodule, it was indicated the right lobe with 93 persons (38%), the left lobe with 67 persons (27%), both lobes with 75 persons (30%), and isthmus with 13 persons (5.3%), thereby representing the largest frequency in the right lobe, and it was discovered less in isthmus.

  • PDF

The Study of patient rotation angle to get the scapular true lateral image in scapular lateral projection (견갑골 측방향 촬영에서 견갑골 정측면상을 얻기 위한 환자의 회전각도에 관한 연구)

  • Park, Ki-Bong;Kang, In-Hyi;Choi, Nam-Kil;Jang, Young-Il;Jeon, Ju-Seob
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.203-209
    • /
    • 2005
  • Objective True lateral scapular image was very important to diagnosis the scapular fracture and dislocation induced by traumatic injury. The aim of this study was to know the patient rotation angle to be showing the scapular true lateral in Korean. Subjects and Materials Thirty patients(22men, 8 women, mean ages 53.4)with scapular pain, had supine anteroposterior projection taken with $32^{\circ}$, $37^{\circ}$, $42^{\circ}$ trunk rotation angle changing the manual angulation material. Radiographs were evaluated independently by 5 experienced observers(1 orthopedics surgery specialist, 1 diagnostic radiology specialist, 3 radiological technologist) They assessed overlab of vertebral border and axillary border of scapular as follows; Totally overlapping of vertebral border and axillary border is 4, partially overlapping is 3, not overlapping is 2 and oblique location with two borders is 1. All observers scored using by PACS monitor. Results $32^{\circ}$ trunk rotation was scored $1.53{\pm}0.39$, $37^{\circ}$ trunk rotation was scored $3.83{\pm}0.15$ and $42^{\circ}$trunk rotation was scored $2.17{\pm}0.43$. There was no difference(p<0.05) between group of more than 100cm of the girth of the chest and group of less than 100cm. Similarly, men and women group showed no difference(p<0.05) with trunk rotation statistically. Conclusions There was no result of trunk rotation angle to radiograph the true scapular lateral image up to date. This studies were summarized as follows; Adaptation of $37^{\circ}$ trunk rotation was the best to show the true scapular lateral image in Korean. Our results were very useful to get the true scapular lateral images in clinic.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF