• Title/Summary/Keyword: target-filter combination

Search Result 19, Processing Time 0.02 seconds

The Image Quality according to Target-Filter Combination in Digital Mammography (디지털유방촬영장치에서 타깃-필터 조합에 따른 영상분석)

  • Kim, Do-Hyung;Choi, Seokyoon;Kim, Dong-Hyen
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.121-124
    • /
    • 2015
  • Digital Mammography is very important for the early diagnosis of breast cancer. but excessive radiation dose to the patient may increase the probability of occurrence of breast cancer. absorbed dose rate and signal, noise, and contrast in accordance with the change of the filter, and analyzed the signal-to-noise ratio. absorbed dose rate GE Equipment is higher than that of Siemens and Hologic. using the material of Mo / Mo was lower than the other target-filter combination. SNR of Siemens equipment is high and measured high when Mo / Mo selected, the other two devices was measured high when Mo / Rh selected. when you choose a target-filter combination our results will be a good indicator.

Evaluation of MTF Image by Target/Filter Combined of X-ray Tube Using Mammography (유방촬영용 X선관 target/filter 조합에 따른 MTF영상평가에 관한 고찰)

  • Yang, Han-Jun;Joo, Mi-Hwa;Ko, Sin-Kwan
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.113-119
    • /
    • 2007
  • It is important to consider the contrast of object in Mammography because an absorption gap between tissues of body and breast in breast is low. This study is to evaluate MTF image with resolution chart according to change of combination of target and filter. The results were as follows : 1. There were significant differences in X-ray energy according to combination of filter(Mo/Mo, Mo/Rh. Mo/Al, Rh/Rh, Rh/Al) and acrylic thickness(2 cm, 3 cm, 4 cm). 2. The value of lp/mm on MTF to 0.5 showed that the sharpness in MTF curve was 2.4 compared to Mo/Mo and 2cm acryl, 2.63 in Mo/Rh and 4 cm acryl, and 2.9 in Rh/Rh and 6cm acryl. 3. The value of lp/mm on MTF showed that the resolution in MTF curve was 6.0 compared to Mo/Mo and 2 cm acryl, 4.60 in Rh/Al and 4cm acryl, and 6.03 in Rh/Al and 6 cm acryl. 4. The value of MTF on 2.5 lp/mm distinguishable visually was 0.48 compared to Mo/Mo and 2 cm acryl, 0.53 in Mo/Rh and 4cm acryl, and 0.59 in Rh/Rh and 6cm acryl. 5. For the evaluation of an image of the mammo-phantom, the score of Mo/Mo was 12 points, Mo/Rh 11, Rh/Rh 10.5, Mo/Al 10, Rh/Al 9.0, respectively.

  • PDF

Effects of Tipping Paper and Plug Wrap on Cigarette Filter Ventilation (팁페이파 및 필터권지 기공도 조합이 제품담배 공기희석율에 미치는 영향)

  • 김정열;김종열;신창호
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.1
    • /
    • pp.60-64
    • /
    • 2001
  • The variability of a ventilated filter cigarette depends on the details of its construction and one properties of its components and the variations in filter ventilation is effected by many factors such as tobacco column pressure drop, filter pressure drop, tipping paper and plug wrap permeability, and vent position. In this study, the effects of combination of tipping paper and plug wrap on filter ventilation of cigarettes were studied for the target ventilation level under the specific tobacco column and filter tip in order to reduce the variation of filter ventilation. When Nicolas Baskevitch\`s equation on filter ventilation was used to try out Monte Carlo Simulation, at the combination where tipping paper permeability is high and plug wrap permeability is low, even the small change in tipping paper and plug wrap permeability showed high variation of target ventilation level. Also, according to the analysis data of filter ventilation in cigarettes designed at the level of 45% filter ventilation by the combinations with tipping paper and plug wrap, the variation in cigarette filter ventilation was increased as increasing tipping paper permeability and decreasing plug wrap permeability. As the results of this study, the variation of filter ventilation can be reduced by increasing plug wrap permeability/tipping paper permeability ratio in the cigarette design, considering 2-3% of tipping paper permeability variation(%CV) and about 10% of plugwrap permeability variation.

  • PDF

Gun fire Control System Design with Maneuvering Target State Estimates (기동표적의 상태추정을 이용한 포의 사격통제 시스템 향상 연구)

  • Lee, Dong-Gwan;Song, Taek-Lyul;Han, Du-Hee
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.3
    • /
    • pp.98-109
    • /
    • 2006
  • Fire control system(FCS) errors can be classified as hardware errors, filter prediction errors, effective ballistic function errors, and aiming errors. Among these errors, the filter prediction errors are the most significant error sources. To reduce them, a target future position calculation method using the acceleration estimate is suggested and it is compared with the constant velocity target prediction method. Simulation results show that the suggested method has better performance than the constant velocity prediction method. Target tracking algorithm is established with multiple target tracking filters based on IMM structure.

A Study on Measurement Time Reduction for Multi-Channel Combination Scale (다채널 조합형 계량기의 안정화 성능 개선에 관한 연구)

  • Lee, Hyeong-Ill;Ban, Kap-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.103-109
    • /
    • 2016
  • The performance of a multi-head, computerized combination scaling system to automatically identify a group of agricultural products having a total weight within the target range has been optimized to reduce the package cycle time of the merchandise. First, the structure of the scale was modified to enable faster measurement by enhancing the dynamic stability during the process. Second, the high frequency noise in the measured signal was eliminated by a high frequency filter to provide more accurate weight data. Finally, the algorithm to identify a group of products with a total weight within the target range was modified to enable a user to select an optimal number of scales. According to the experimental verifications, this modified system reduced the package cycle time significantly and also was accurate in measuring the total weight of the selected products.

Comparison of Average Glandular Dose in Screen-Film and Digital Mammography Using Breast Tissue-Equivalent Phantom (유방조직등가 팬텀을 이용한 Screen-Film과 Digital Mammography에서의 평균 유선선량)

  • Shin, Gwi-Soon;Kim, Jung-Min;Kim, You-Hyun;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.13-23
    • /
    • 2007
  • In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate(IP). We measured average glandular doses(AGD) in screen-film mammography(SFM) system with slow screen-film combination, computed mammography(CM) system, indirect digital mammography(IDM) system and direct digital mammography(DDM) system using brest tissue-equivalent phantom(glandularity 30%, 50% and 70%). The results were shown as follows : AGD values for DDM system were highest than those for other systems. Although automatic exposure control(AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter(Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in oder to estimate a patient radiation dose.

  • PDF

A Study on Target Acquisition and Tracking to Develop ARPA Radar (ARPA 레이더 개발을 위한 물표 획득 및 추적 기술 연구)

  • Lee, Hee-Yong;Shin, Il-Sik;Lee, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.39 no.4
    • /
    • pp.307-312
    • /
    • 2015
  • ARPA(Automatic Radar Plotting Aid) is a device to calculate CPA(closest point of approach)/TCPA(time of CPA), true course and speed of targets by vector operation of relative courses and speeds. The purpose of this study is to develop target acquisition and tracking technology for ARPA Radar implementation. After examining the previous studies, applicable algorithms and technologies were developed to be combined and basic ARPA functions were developed as a result. As for main research contents, the sequential image processing technology such as combination of grayscale conversion, gaussian smoothing, binary image conversion and labeling was deviced to achieve a proper target acquisition, and the NNS(Nearest Neighbor Search) algorithm was appllied to identify which target came from the previous image and finally Kalman Filter was used to calculate true course and speed of targets as an analysis of target behavior. Also all technologies stated above were implemented as a SW program and installed onboard, and verified the basic ARPA functions to be operable in practical use through onboard test.

Sliding Window Filtering for Ground Moving Targets with Cross-Correlated Sensor Noises

  • Song, Il Young;Song, Jin Mo;Jeong, Woong Ji;Gong, Myoung Sool
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.146-151
    • /
    • 2019
  • This paper reports a sliding window filtering approach for ground moving targets with cross-correlated sensor noise and uncertainty. In addition, the effect of uncertain parameters during a tracking error on the model performance is considered. A distributed fusion sliding window filter is also proposed. The distributed fusion filtering algorithm represents the optimal linear combination of local filters under the minimum mean-square error criterion. The derivation of the error cross-covariances between the local sliding window filters is the key to the proposed method. Simulation results of the motion of the ground moving target a demonstrate high accuracy and computational efficiency of the distributed fusion sliding window filter.

On using Bayes Risk for Data Association to Improve Single-Target Multi-Sensor Tracking in Clutter (Bayes Risk를 이용한 False Alarm이 존재하는 환경에서의 단일 표적-다중센서 추적 알고리즘)

  • 김경택;최대범;안병하;고한석
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.159-162
    • /
    • 2001
  • In this Paper, a new multi-sensor single-target tracking method in cluttered environment is proposed. Unlike the established methods such as probabilistic data association filter (PDAF), the proposed method intends to reflect the information in detection phase into parameters in tracking so as to reduce uncertainty due to clutter. This is achieved by first modifying the Bayes risk in Bayesian detection criterion to incorporate the likelihood of measurements from multiple sensors. The final estimate is then computed by taking a linear combination of the likelihood and the estimate of measurements. We develop the procedure and discuss the results from representative simulations.

  • PDF

Assessment of Organ Dose in Mammoplasty Patient by Monte Carlo Simulation during Mammography (유방촬영 시 몬테칼로 전사모사를 이용한 유방 성형 환자의 장기선량 평가)

  • Kim, Ji-Soo;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.337-341
    • /
    • 2020
  • Although the screening with a mammography has been shown to be economical, simple and effective in detecting breast cancer, it is accompanied by the risk from radiation. Therefore, this study analyzed the glandular dose and organ dose according to the target-filter combination and the presence and absence of implants using Monte Carlo simulation. The results indicate that at a tube voltage of 30 kV and a tube current of 50 mAs, the dose increased in the order of Mo/Mo. Mo/Rh, Rh/Rh and W/Rh in proportion to the atomic number of the target-filter. In addition, in phantom without implant a reduction in dose was seen when compared to the phantom with implant. The organ dose was highest in the lens except for the breast on the examination side regardless of the presence or absence of the implant. These results may contribute to use basic data for the diagnostic reference level of breast plastic surgery patients.