• Title/Summary/Keyword: target variation rate

Search Result 94, Processing Time 0.021 seconds

Effects of Herbicides on Growth and Reproductive Characters of Glycine max (대두(Glycine max)의 생장 및 번식 특성에 미치는 제초제의 영향)

  • Gang, Hye-Sun;Ha, Seung-Hui
    • The Korean Journal of Ecology
    • /
    • v.24 no.3
    • /
    • pp.157-168
    • /
    • 2001
  • Herbicides have been used to control weeds for decades. If detoxification upon exposure to herbicides requires considerable amounts of energy, it could affect the pattern of resource allocation to growth and reproduction of crops. We examined the effects of three levels of a herbicide (Control, Low, and High) on germination, growth and reproductive characters of Glycine max treated twice, i.e., before and after seed germination. Since flowering time of G. max was separated into two groups, flowering time was also considered as a variable in this study. The rate of seed germination tended to be higher at the low level of herbicide compared to other levels. Chlorosis and shape variation of leaves were apparent after the second herbicide treatment, but completely disappeared after six weeks of treatment. The herbicide effects on growth characters were somewhat different between early and late flowering plants, but plants treated with both low and high levels of herbicide reduced their growth compared to those in the control group regardless of flowering time. Plants at the high level of herbicide exhibited the highest growth rate later in the season, suggesting that plants compensated to some extent for reduced growth. However, growth reduction among plants at the high level of herbicide was persistent until the end of growing season. Among plants flowered late in the season, plants in the control level bore a higher number of nodules per plant than those in other levels; such a pattern did not exist among plants flowered early in the season. Plants treated with low and high levels of herbicide produced a lower number of flowers than those in the control. Thus, the herbicide examined affected not only the growth and reproductive characters of non-target crops but also the development and growth of root nodules.

  • PDF

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.

Dosimetric Effect on Selectable Optimization Parameters of Volumatric Modulated Arc Therapy (선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향)

  • Jung, Jae-Yong;Shin, Yong-Joo;Sohn, Seung-Chang;Kim, Yeon-Rae;Min, Jung-Wan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.15-25
    • /
    • 2012
  • The aim of this study is to evaluate plan quality and dose accuracy for Volumetric Modulated Arc Therapy (VMAT) on the TG-119 and is to investigate the effects on variation of the selectable optimization parameters of VMAT. VMAT treatment planning was implemented on a Varian iX linear accelerator with ARIA record and verify system (Varian Mecical System Palo Alto, CA) and Oncentra MasterPlan treatment planning system (Nucletron BV, Veenendaal, Netherlands). Plan quality and dosimetric accuracy were evaluated by effect of varying a number of arc, gantry spacing and delivery time for the test geometries provided in TG-119. Plan quality for the target and OAR was evaluated by the mean value and the standard deviation of the Dose Volume Histograms (DVHs). The ionization chamber and $Delta^{4PT}$ bi-planar diode array were used for the dose evaluation. For treatment planning evaluation, all structure sets closed to the goals in the case of single arc, except for the C-shape (hard), and all structure sets achieved the goals in the case of dual arc, except for C-shape (hard). For the variation of a number of arc, the simple structure such as a prostate did not have the difference between single arc and dual arc, whereas the complex structure such as a head and neck showed a superior result in the case of dual arc. The dose distribution with gantry spacing of $4^{\circ}$ was shown better plan quality than the gantry spacing of $6^{\circ}$, but was similar results compared with gantry spacing of $2^{\circ}$. For the verification of dose accuracy with single arc and dual arc, the mean value of a relative error between measured and calculated value were within 3% and 4% for point dose and confidence limit values, respectively. For the verification on dose accuracy with the gantry intervals of $2^{\circ}$, $4^{\circ}$ and $6^{\circ}$, the mean values of relative error were within 3% and 5% for point dose and confidence limit values, respectively. In the verification of dose distribution with $Delta^{4PT}$ bi-planar diode array, gamma passing rate was $98.72{\pm}1.52%$ and $98.3{\pm}1.5%$ for single arc and dual arc, respectively. The confidence limit values were within 4%. The smaller the gantry spacing, the more accuracy results were shown. In this study, we performed the VMAT QA based on TG-119 procedure, and demonstrated that all structure sets were satisfied with acceptance criteria. And also, the results for the selective optimization variables informed the importance of selection for the suitable variables according to the clinical cases.

Characteristics and Variation of Panicle Traits of Korean Rice Varieties in Wet Season of the Philippines (국내 육성 벼 품종의 필리핀 우기재배에서의 이삭형질 변이 및 특성)

  • Park, Hyun-Su;Kim, Ki-Young;Mo, Young-Jun;Choi, In-Bae;Baek, Man-Kee;Ha, Ki-Yong;Ha, Woon-Goo;Kang, Hyun-Jung;Shin, Mun-Sik;Ko, Jae-Kwon
    • Korean Journal of Breeding Science
    • /
    • v.43 no.1
    • /
    • pp.68-80
    • /
    • 2011
  • This study was conducted to investigate characteristics and variations of rice panicle traits for breeding temperate japonica varieties adapted to tropical environment. Eleven panicle traits were investigated from nine Korean rice varieties cultivated in Korea and wet season of the Philippines. Tested cultivars were composed of six temperate japonica varieties, three Tongil-type varieties, and one indica variety bred in the Philippines. The number of spikelets on secondary rachis branches (SRBs) was the most variable trait in both environments, while the mean number of spikelets on a primary rachis branch (PRB) was the least variable. Compared with PRB-related traits, SRB traits showed higher correlation with the number of spikelets per panicle. Compared with the plants grown in Korea, the number of spikelets on SRBs, the number of SRBs, spikelets, and rachis branches per panicle were decreased more than other traits in the Philippines. According to path analysis, the number of spikelets on SRBs per panicle affects the number of spikelets per panicle more than the number of spikelets on PRBs per panicle. Climatic factors such as growth duration, cumulative mean temperature, and integrated solar radiation were highly correlated with the relative rate of number of spikelets per panicle. To breed temperate japonica rice varieties adapted to tropical environment, it would be important to select lines which maintain proper growth duration and spikelets on SRBs in target region.