• Title/Summary/Keyword: target precision

Search Result 545, Processing Time 0.339 seconds

권총의 최대반동력 측정 및 해석 (Measurement and analysis the peak recoil force of pistol)

  • 엄혁
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.1033-1036
    • /
    • 1996
  • In Pistol, the peak recoil force affects the reliability of the frame and the accuracy of target shooting. To attenuate the peak recoil force of pistol, we develop measuring test bed, which consists of force sensors, linear sensor and a high speed video camera, execute tests with several Pistol models and compare the results measured.

  • PDF

김발의 가속도 시험용 Shaker의 설계 및 개발 (Design and Development of Shaker for Acceleration test of Gimbal)

  • 윤재윤
    • 한국정밀공학회지
    • /
    • 제18권1호
    • /
    • pp.147-153
    • /
    • 2001
  • This paper proposes a shaker system design for acceleration test of gimbal. Main reason of shaker system design is to give acceleration to the gimbal, which is moving and tracking the target on the tracking test equipment. The shaker system is mounted on the tracking test equipment. It uses the scotch yoke mechanism to have the constant movement in return. The Scotch yoke mechanism changes the rotational movement of constant velocity to simple harmonic motion.

  • PDF

거세저항성전립선암에서 정밀의학에 대한 고찰 (Precision Medicine in Castration-Resistant Prostate Cancer)

  • 김원태;윤석중;김원재
    • 대한비뇨기종양학회지
    • /
    • 제16권3호
    • /
    • pp.97-102
    • /
    • 2018
  • Prostate cancer is usually managed by androgen deprivation therapy after failure of primary treatment. However, such therapies are only temporarily effective in prostate cancer patients, and the most patients experience the progression to castration-resistant prostate cancer (CRPC). Docetaxel chemotherapy is conventional effective treatment for CRPC but has many adverse effects. In CRPC patients, treatment decisions were not typically base on the recognitions of inter-individual differences. Therefore, there are growing interests for precision medicine in CRPC. In this review, we summarized the precision medicine such as candidate target genes and potential therapies in CRPC.

Couch의 좌표 확인을 이용한 치료 위치 이동의 정확성 평가 (Precision evaluation of the treatment that used coordinates confirmation of couch in case of two forgets adjoined.)

  • 서정민;정천영;박영환;송기원
    • 대한방사선치료학회지
    • /
    • 제15권1호
    • /
    • pp.35-40
    • /
    • 2003
  • I. 목적 방사선 치료에서 인접한 두 target을 가진 두경부 환자의 target간의 이동시, 육안으로 판별하여 수동으로 couch를 이동하는 방식에서 나타날 수 있는 오차를 확인하기 위하여, couch의 좌표값을 분석하고 target간의 이동에 대한 재현성의 정확성을 평가하고자 한다. II. 대상 및 방법 방사선 치료에 있어서 치료하고자 하는 인접한 두 target간의 이동시 operator에 의한 수동이동에서 나타날 수 있는 이동오차를 확인하기 위하여, couch의 좌표값(vertical, longitudinal, lateral 세 방향)을 이용, 수동으로 위치잡이시 이동거리에 대한 정확도를 평가하기 위해 치료장비( CL 2100C, Varian, USA) 의 console monitor에 나타난 좌표값을 기록하였다. 매 치료마다 vertical, longitudinal, lateral 세 방향에서 기록된 좌표의 이동거리를 구한 후에, 이를 RTP(Pinnacle, ADAC, USA)에 의한 target간의 거리와 비교하여 오차값을 구하였다. 동일환자를 10회에 걸쳐 실제 set-up시의 좌표이동의 평균값과 오차정도, 그리고 표준편차를 구하였다. III. 결과 환자의 skin mark를 육안으로 확인하며 수동으로 couch를 이동하는 방식에서 두 target간 이동의 평균 표준편차가 각 방향에서 vertical 1.4mm, longitudinal 0.9mm, lateral 2.2mm로 나타났고, 직선상의 이동오차는 평균 약 3.6mm, 최대 5.1mm의 오차가 나타났다. Lateral 방향에서 오차정도가 가장 커서 최대 5mm까지 오차가 발생하였으며, 각 방향에서 오차평균값은 vertical 1mm, longitudinal 0.7mm, lateral 2.7mm이고 이중에서 가장 오차가 큰 lateral방향의 오차평균값을 크게 넘어서는 경우는 전체의 $30\%$정도로 나타났다. IV. 결론 Couch를 수동으로 이동하여 target간을 이동시, 평균 약 3.6mm정도의 오차가 발생하였다. 3D conformal therapy나 IMRT처럼 높은 정밀도를 요구하는 치료의 경우에는 인접한 target간의 정확한 이동을 요구하므로, couch의 실제 좌표의 오차를 확인하는 일이 중요하다. 따라서 couch의 좌표확인을 이용한 치료의 재현성과 정확성 평가를 더욱 발전시켜 응용한다면 양질의 방사선 치료를 실시할 수 있을 것이라 사료된다.

  • PDF

VRS RTK를 이용한 원거리 표적좌표획득의 정확도 향상에 대한 연구 (Study for Improving Target Coordinate Acquisition Accuracy from Long Distance by VRS RTK)

  • 이동녁;윤근식
    • 한국군사과학기술학회지
    • /
    • 제21권4호
    • /
    • pp.471-480
    • /
    • 2018
  • Accurate target coordinate is very important in military operations especially field artillery's ground-to-ground attack and air-force's air-to-ground attack. DOS(or TAS) is used to acquire target coordinates from long distance. DOS is comprised of LRF and goniometer. LRF measures distance between DOS and target. Goniometer is comprised of azimuth and vertical angular sensors, DMC and internal GPS receiver. DOS must set the position and orientation(finding grid north) before measurement step(target coordinate acquisition). To improve accuracy of target coordinate, VRS RTK and reference point method are proposed in DOS setup step. VRS RTK provides accurate location coordinate with small deviations, providing high accuracy and precision in positioning and orientation. As a result, horizontal coordinate(easting and northing) accuracy is improved from 2.68 mil(C.L. = 0.95) mil to 0.58 mil(C.L. = 0.95).

Helmet Mounted Display 장비를 사용한 공대지 표적의 위치정보 획득 (Location Information Extraction of An Air-to-Ground Target using Helmet Mounted Display Device)

  • 방극열;하석운
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권3호
    • /
    • pp.1-7
    • /
    • 2011
  • 무장 전투기와 같은 공격용 항공기는 정밀한 공대공 또는 공대지 공격을 위해 표적의 정확한 위치 정보를 필요로 한다. 본 논문에서는 레이더나 FLIR과 같은 표적추적센서 없이 공대공 유도탄의 seeker head를 조종사의 머리가 가리키는 방향으로 유도하는 장비인 HMD만을 사용하여 공대지 표적의 위치정보를 획득하는 방법을 제시한다. 시뮬레이션 실험을 행한 결과 HMD를 수동 센서로 사용할 경우 다른 표적추적센서와의 연동 없이 HMD 만으로도 높은 정밀도의 표적 위치 정보를 획득할 수 있음을 발견하였다.

Target Market Determination for Information Distribution and Student Recruitment Using an Extended RFM Model with Spatial Analysis

  • ERNAWATI, ERNAWATI;BAHARIN, Safiza Suhana Kamal;KASMIN, Fauziah
    • 유통과학연구
    • /
    • 제20권6호
    • /
    • pp.1-10
    • /
    • 2022
  • Purpose: This research proposes a new modified Recency-Frequency-Monetary (RFM) model by extending the model with spatial analysis for supporting decision-makers in discovering the promotional target market. Research design, data and methodology: This quantitative research utilizes data-mining techniques and the RFM model to cluster a university's provider schools. The RFM model was modified by adapting its variables to the university's marketing context and adding a district's potential (D) variable based on heatmap analysis using Geographic Information System (GIS) and K-means clustering. The K-prototype algorithm and the Elbow method were applied to find provider school clusters using the proposed RFM-D model. After profiling the clusters, the target segment was assigned. The model was validated using empirical data from an Indonesian university, and its performance was compared to the Customer Lifetime Value (CLV)-based RFM utilizing accuracy, precision, recall, and F1-score metrics. Results: This research identified five clusters. The target segment was chosen from the highest-value and high-value clusters that comprised 17.80% of provider schools but can contribute 75.77% of students. Conclusions: The proposed model recommended more targeted schools in higher-potential districts and predicted the target segment with 0.99 accuracies, outperforming the CLV-based model. The empirical findings help university management determine the promotion location and allocate resources for promotional information distribution and student recruitment.

Performance evaluation of a 400 W precise window motor for glass houses

  • Hong, Soon-Joong;Park, Soo-Bok;Kang, Na-Rae;Kim, Yong-Joo;Chung, Sun-Ok
    • 농업과학연구
    • /
    • 제44권4호
    • /
    • pp.595-603
    • /
    • 2017
  • Crop growth and production cost are greatly influenced by management of environmental factors such as ambient temperature, humidity, and $CO_2$, especially in protected horticulture. Opening and closing of greenhouses is the most important operation for control of these ambient environmental factors, and precise and stable operation requires high performance window motors. In this study, a 400 W precise window motor was constructed, and its performance was evaluated for plastic and glass greenhouses. First, the motor was designed and fabricated by benchmarking of an advanced foreign product. Then, the performance was evaluated through vibration, PCB (Process Control Block), and load tests. Vibration tests resulted in averaged vibration displacement and velocity of the developed motor of 0.002 mm and 0.2267m/s, which were statistically significantly different from those of the target motor. Average vibration acceleration ($0.26m/s^2$) of the developed motor was also significantly different from that ($0.51m/s^2$) of the target motor. PCB tests showed 2 - 4 mm deviation from the target values, and confirmed the operating status and precision of the control. Load tests with a 300 kg load also showed acceptable operating status and durability. Current values were $1.31{\pm}0.06A$ and RPMs were in the range of 2.9 - 3.0. Considering the above results, the developed window motor would be competitive to the target foreign product.

Comparison of the Immediate Effect of the Whole-body Vibration on Proprioceptive Precision of the Knee Joint Between Barefoot and Shoe-wearing Conditions in Healthy Participants

  • Lee, Yu-bin;Hwang, Ui-jae;Kwon, Oh-yun
    • 한국전문물리치료학회지
    • /
    • 제28권2호
    • /
    • pp.108-116
    • /
    • 2021
  • Background: Whole-body vibration (WBV) has been used to alleviate proprioceptive damage by musculoskeletal and neurological conditions. However, no study has determined whether wearing shoes while applying WBV can affect proprioception precision of the knee joint. Objects: This study aimed to determine the differences in the proprioceptive precision of the knee joint before and after WBV and to compare the proprioceptive precision of the knee joint between barefoot and shoe-wearing conditions. Methods: This study recruited 33 healthy participants. A passive-to-active angle reproduction test was used to measure the proprioception precision of the knee joint using an electrogoniometer, and the target angle was set to a knee flexion of 30°. Proprioception precision was calculated using the error angle (angular difference from 30°). Proprioceptive precision was measured in weight-bearing and non-weight-bearing positions before and after applying WBV for 20 minutes at 12 Hz in barefoot and shoe-wearing conditions. Mixed repeated analysis of variance was used to determine the differences in changes in the proprioceptive precision of the knee joint according to foot conditions. Results: There were significant improvements in the weight-bearing (p = 0.002) and non-weight-bearing (p < 0.001) proprioceptive precision of the knee joint after applying WBV. However, there was no significant difference in the change in proprioceptive precision of the knee joint after applying WBV between the barefoot and shoe-wearing conditions. Conclusion: WBV stimulation had an immediate effect on improving the proprioceptive precision of the knee joint. However, foot conditions (barefoot or shoe-wearing) during WBV application did not influence the proprioceptive precision of the knee joint.

구성품 요구 성능 설정을 위한 정밀 유도무기의 비행 중 롤 영향성 연구 (Study on Effects of Roll in Flight of a Precision Guided Missile for Subsytem Requirements Analysis)

  • 정동길;박진서;이종희;전두성;손성한
    • 한국시뮬레이션학회논문지
    • /
    • 제28권2호
    • /
    • pp.131-137
    • /
    • 2019
  • 현대전이 내전과 대테러전과 같은 국지전 양상으로 변화하면서, 탐색기를 포함한 정밀 유도무기의 운용 비중이 점점 증가하고 있다. 영상탐색기는 상대적으로 저가이며, 다양한 운용환경에 적용이 가능하다. 다만 유도무기에 적용되는 영상추적기술은 유도탄의 비행 환경 하에서 표적 추적을 수행해야하므로 상당히 고난이도의 기술이 요구된다. 그 중 유도탄의 롤은 다른 거동에 비해 탐색기 영상에 큰 변화를 주게 되어 영상 추적 성능을 크게 저하시킬 수 있다. 롤은 외란 및 비행 제어 오차로 항상 발생할 수밖에 없으나, 영상 추적 및 체계 성능에 영향을 주지 않는 수준을 판단하여 구성품의 오차 관리를 해야 한다. 하지만 표적의 영상 특성 및 영상 추적기의 높은 비선형성으로 단순한 기준으로 성능 예측을 한다는 것은 매우 어려운 일이다. 본 연구에서는 영상탐색기가 적용된 정밀유도무기의 M&S 환경을 구축하고, 유도탄의 롤 거동이 영상 추적 및 체계 성능에 미치는 영향을 분석하였다. 또한 오차 분석을 통해 유도무기 성능보장을 위해 요구되는 구성품의 규격을 도출하였다.