• Title/Summary/Keyword: target matching

Search Result 359, Processing Time 0.024 seconds

Evaluation of Park Re-planning by Feasibility Study in Korea National Parks - Focusing on Area Adjustment of Hallyeohaesang National Park - (국립공원 타당성검토에 따른 공원재계획 평가 - 한려해상국립공원 구역조정을 중심으로 -)

  • Woo Cho
    • Korean Journal of Environment and Ecology
    • /
    • v.38 no.1
    • /
    • pp.79-89
    • /
    • 2024
  • The purpose of this study was to evaluate the area adjustment criteria and methods of the feasibility study of national park plans by applying them to Hallyeohaesang National Park. As a result of the ecological-based assessment used to identify the adjustment target areas, the ecological-based assessment Grades I and II that can be considered for inclusion were analyzed as 10.0% and 40.4%, respectively. Grade V, which can be considered for release, was 9.9%. As a result of the inclusion and release suitability assessment, the area subject to inclusion was 35.150 km2 (3.669 km2 on land and 31.481 km2 at sea), and the area subject to release was 0.071 km2 on land. When local governments and residents request the release of a park area for public interest or convenience, the release can be considered as long as the total area does not change, which is called a mutual exchange. The release area determined by mutual exchange was 10.386 km2. It was 146 times the area determined by the suitability assessment for release. Matching the areas released by the mutual exchange with the ecological-based assessment, 70.6% (7.321 km2) was in Grades I and II, which can never be released. As a result, it was determined that the area adjustment of the feasibility study of Hallyeohaesang National Park was based on a very limited application of the results of the ecological-based assessment or the release suitability assessment. Also, mutual exchange was the key to area adjustment of the feasibility studies of national parks.

Verification of Skin Dose in Tomotherapy Using the Developed Phantom for Image Based Radiation Treatment System (영상 기반 치료 장비용 팬톰을 이용한 토모테라피 피부 선량 검증)

  • Park, Ji-Yeon;Chang, Ji-Na;Oh, Seung-Jong;Kang, Dae-Gyu;Jung, Won-Gyun;Lee, Jeong-Woo;Jang, Hong-Suk;Kim, Hoi-Nam;Park, Hae-Jin;Kim, Sung-Hwan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.88-96
    • /
    • 2009
  • Radiation treatment for skin cancer has recently increased in tomotherapy. It was reported that required dose could be delivered with homogeneous dose distribution to the target without field matching using electron and photon beam. Therapeutic beam of tomotherapy, however, has several different physical characteristic and irradiation of helical beam is involved in the mechanically dynamic factors. Thus verification of skin dose is requisite using independent tools with additional verification method. Modified phantom for dose measurement was developed and skin dose verification was performed using inserted thermoluminescent dosimeters (TLDs) and GafChromic EBT films. As the homogeneous dose was delivered to the region including surface and 6 mm depth, measured dose using films showed about average 2% lower dose than calculated one in treatment planning system. Region indicating about 14% higher and lower absorbed dose was verified on measured dose distribution. Uniformity of dose distribution on films decreased as compared with that of calculated results. Dose variation affected by inhomogeneous material, Teflon, little showed. In regard to the measured dose and its distribution in tomotherapy, verification of skin dose through measurement is required before the radiation treatment for the target located at the curved surface or superficial depth.

  • PDF

USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN (전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가)

  • Park, Do-Geun;Choe, Byeong-Gi;Kim, Jin-Man;Lee, Dong-Hun;Song, Gi-Won;Park, Yeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • Purpose : By taking advantage of each imaging modality, the use of fused CT/MRI image has increased in prostate cancer radiation therapy. However, fusion uncertainty may cause partial target miss or normal organ overdose. In order to complement such limitation, our hospital acquired MRI image (Planning MRI) by setting up patients with the same fixing tool and posture as CT simulation. This study aims to evaluate the usefulness of the Planning MRI through comparing and analyzing the diagnostic MRI image and Planning MRI image. Materials and Methods : This study targeted 10 patients who had been diagnosed with prostate cancer and prescribed nonhormone and definitive RT 70 Gy/28 fx from August 2011 to July 2013. Each patient had both CT and MRI simulations. The MRI images were acquired within one half hour after the CT simulation. The acquired CT/MRI images were fused primarily based on bony structure matching. This study measured the volume of prostate in the images of Planning MRI and diagnostic MRI. The diameters at the craniocaudal, anteroposterior and left-to-right directions from the center of prostate were measured in order to compare changes in the shape of prostate. Results : As a result of comparing the volume of prostate in the images of Planning MRI and diagnostic MRI, they were found to be $25.01cm^3$(range $15.84-34.75cm^3$) and $25.05cm^3$(range $15.28-35.88cm^3$) on average respectively. The diagnostic MRI had an increase of 0.12 % as compared with the Planning MRI. On the planning MRI, there was an increase in the volume by $7.46cm^3$(29 %) at the transition zone directions, and there was a decrease in the volume by $8.52cm^3$(34 %) in the peripheral zone direction. As a result of measuring the diameters at the craniocaudal, anteroposterior and left-to-right directions in the prostate, the Planning MRI was found to have on average 3.82cm, 2.38cm and 4.59cm respectively and the diagnostic MRI was found to have on average 3.37cm, 2.76cm and 4.51cm respectively. All three prostate diameters changed and the change was significant in the Planning MRI. On average, the anteroposterior prostate diameter decrease by 0.38cm(13 %). The mean right-to-left and craniocaudal diameter increased by 0.08cm(1.6 %) and 0.45cm(13 %), respectively. Conclusion : Based on the results of this study, it was found that the total volumes of prostate in the Planning MRI and the diagnostic MRI were not significantly different. However, there was a change in the shape and partial volume of prostate due to the insertion of prostate balloon tube to the rectum. Thus, if the Planning MRI images were used when conducting the fusion of CT/MRI images, it would be possible to include the target in the CTV without a loss as much as the increased volume in the transition zone. Also, it would be possible to reduce the radiation dose delivered to the rectum through separating more clearly the reduction of peripheral zone volume. Therefore, the author of this study believes that acquisition of Planning MRI image should be made to ensure target delineation and localization accuracy.

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.

Comparative Analysis in Visitors' Perception of Aftermath of the Country's Garden Exposition- Focused on the 2013 Suncheon Bay International Garden Expo, 2015 Seoul Garden Expo, and 2022 Goyang International Flower Fair - (국내정원박람회 개최 효과에 대한 방문객 인식 비교 연구 - 2013 순천만국제정원박람회, 2015 서울정원박람회, 2022 고양국제꽃박람회를 대상으로 -)

  • Kim, Tai-Won;Kim, Gunwoo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.6
    • /
    • pp.58-69
    • /
    • 2022
  • This study compares and analyses the impacts of holding domestic garden expos that will be fundamental for holding garden expos in the future. Satisfaction with the three sites of the 2013 Suncheon Bay International Gardening Expo, 2015 Seoul Gardening Expo, and 2022 Goyang International Flower Fair, as well as factors affecting the satisfaction in economic, social/cultural, environment/ecology, and operation aspects, were analyzed. As a result of the study, the satisfaction level of all three sites was high, with a value of 3.5 or higher. In particular, satisfaction with the 2013 Suncheon Bay International Gardening Expo was the highest. It was found that there was a difference between the satisfaction level of the 2013 Suncheon Bay International Gardening Expo and the 2015 Seoul Gardening Expo. As a regional festival, the 2013 Suncheon Bay International Garden Expo has acquired a high status due to the 'Suncheon Bay Garden' being designated as the first National Garden. It is thought that great satisfaction was obtained because economic, social, cultural, and environmental revitalization was achieved by matching the values of citizen participation and ecological conservation. As a result of the comparison of perception types affecting the satisfaction by garden fair, satisfaction at the 2013 Suncheon Bay International Gardening Expo and the 2015 Seoul Gardening Expo, it was found that both affected all four aspects. The 2022 Goyang International Flower Fair did not affect satisfaction in the operational aspect. This seems to be because the Goyang International Flower Fair is already a fixed local brand. As a result of analyzing the detailed factors of perception that affect satisfaction, the three target sites were commonly analyzed, including social and cultural factors, which attract cultural events, improve pride and affection for the region, and help educate children. In terms of environmental and ecological factors were analyzed as an inconvenience in life due to traffic congestion. It can be seen that it has the same meaning as the comparative analysis of the difference in factors on the satisfaction of the target site. There is no difference in the effect on satisfaction in terms of social·cultural, and environmental·ecological aspects, but there are differences in terms of economy and operation. Based on the analysis results of this study, to hold a domestic garden expo in the future, it is necessary to properly utilize "environmental" and "ecological" garden aspects that have potential values according to the region's characteristics to develop sustainable, eco-friendly tourism resources. In addition, values will be more apparent when cultural and artistic programs are planned to establish a differentiated identity in the host area and are appropriately used as a marketing means for a local fair. A well-planned local festival through communication with local residents can affect the image of the region and lead to the revitalization of the local communities by securing urban competitiveness along with the establishment of urban brands, so it can be said that local residents' participation and national or local organizations' cooperation is essential.

A Study to Evaluate the Efficacy of CBCT and EXACTRAC on Spine Stereotactic Body Radiation Therapy (CBCT와 EXACTRAC을 이용한 Spine SBRT의 유용성 평가)

  • Choi, Woo Keun;Park, Su Yeon;Park, Do Keun;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.167-173
    • /
    • 2013
  • Purpose: This study is to evaluate the efficacy of the CBCT and EXACTRAC the image on the spine stereotactic body radiation treatment. Materials and Methods: The study compared the accuracy of the dose distribution for changes in the real QA phantom for The shape of the body of the phantom was performed. Novalis treatment artificially set up at the center and to the right, on the Plan 1 mm, 2 mm, 3 mm in front 1 mm, 2 mm, 3 mm and upwards 1 mm, 2 mm, 3 mm and $0.5^{\circ}$ by moving side to side Exactrac error correction and error values of CBCT and plan changes on the dose distribution were recorded and analyzed. Results: Cubic Phantom of the experimental error, the error correction Exactrac X-ray 6D Translation in the direction of the 0.18 mm, Rotation direction was $0.07^{\circ}$. Translation in the direction of the 3D CBCT 0.15 mm Rotation direction was $0.04^{\circ}$. DVH dose distribution using the results of the AP evaluate the change in the direction of change was greatest when moving. Conclusion: ExacTrac image-guided radiation therapy with a common easy and fast to get pictures from all angles, from the advantage of CBCT showed a potential alternative. But every accurate information compared with CT treatment planning and treatment of patients with more accurate than the CBCT ExacTrac the location provided. Changes in the dose distribution in the experiment results show that the treatment of spinal SBRT set up some image correction due to errors at the target and enter the spinal cord dose showed that significant differences appear.

  • PDF

Setup Verification in Stereotactic Radiotherapy Using Digitally Reconstructed Radiograph (DRR) (디지털화재구성사진(Digitally Reconstructed Radiograph)을 이용한 정위방사선수술 및 치료의 치료위치 확인)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.84-88
    • /
    • 1999
  • Purpose :To develop a method for verifying a treatment setup in stereotactic radiotherapy by ma- tching portal images to DRRs. Materials and Methods : Four pairs of orthogonal portal images of one patient immobilized by a thermoplastic mask frame for fractionated stereotactic radiotherapy were compared with DRRs. Portal images are obtained in AP (anteriorfposterior) and lateral directions with a target localizer box containing fiducial markers attached to a stereotactic frame. DRRs superimposed over a planned iso-center and fiducial markers are printed out on transparent films. And then, they were overlaid over onhogonal penal images by matching anatomical structures. From three different kind of objects (isgcenter, fiducial markers, anatomical structure) on DRRs and portal images, the displacement error between anatomical structure and isocenters (overall setup error), the displacement error between anatomical structure and fiducial markers (irnrnobiliBation error), and the displacement error between fiducial markers and isocenters (localization error) were measured. Results : Localization error were 1.5$\pm$0.3 mm (AP), 0.9$\pm$0.3 mm (lateral), and immobilization errors were 1.9$\pm$0.5 mm (AP), 1.9$\pm$0.4 mm (lateral). In addition, overall setup errors were 1.0$\pm$0.9 mm (AP), 1.3$\pm$0.4 mm (lateral). From these orthogonal displacement errors, maximum 3D displacement errors($\sqrt{(\DeltaAP)^{2}+(\DeltaLat)^{2}$)) were found to be 1.7$\pm$0.4 mm for localization, 2.0$\pm$0.6 mm for immobilization, and 2.3$\pm$0.7 mm for overall treatment setup. Conclusion : By comparing orthogonal portal images with DRRs, we find out that it is possible to verify treatment setup directly in stereotactic radiotherapy.

  • PDF

Estimation of $CO_2$ saturation from time-lapse $CO_2$ well logging in an onshore aquifer, Nagaoka, Japan (일본 Nagaoka 육상 대수층에서 시간차 $CO_2$ 물리검층으로부터 $CO_2$ 포화도의 추정)

  • Xue, Ziqiu;Tanase, Daiji;Watanabe, Jiro
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.19-29
    • /
    • 2006
  • The first Japanese pilot-scale $CO_2$ sequestration project has been undertaken in an onshore saline aquifer, near Nagaoka in Niigata prefecture, and time-lapse well logs were carried out in observation wells to detect the arrival of injected $CO_2$ and to evaluate $CO_2$ saturation in the reservoir. $CO_2$ was injected into a thin permeable zone at the depth of 1110m at a rate of 20-40 tonnes per day. The total amount of injected $CO_2$ was 10400 tonnes, during the injection period from July 2003 to January 2005. The pilot-scale demonstration allowed an improved understanding of the $CO_2$ movement in a porous sandstone reservoir, by conducting time-lapse geophysical well logs at three observation wells. Comparison between neutron well logging before and after the insertion of fibreglass casing in observation well OB-2 showed good agreement within the target formation, and the higher concentration of shale volume in the reservoir results in a bigger difference between the two well logging results. $CO_2$ breakthrough was identified by induction, sonic, and neutron logs. By sonic logging, we confirmed P-wave velocity reduction that agreed fairly well with a laboratory measurement on drilled core samples from the Nagaoka site. We successfully matched the history changes of sonic P-wave velocity and estimated $CO_2$ saturation a(ter breakthrough in two observation wells out of three. The sonic-velocity history matching result suggested that the sweep efficiency was about 40%. Small effects of $CO_2$ saturation on resistivity resulted in small changes in induction logs when the reservoir was partially saturated. We also found that $CO_2$ saturation in the $CO_2$-bearing zone responded to suspension of $CO_2$ injection.

A survey on the utilization practice and satisfaction of users of food and nutrition information (정보이용자의 식품영양정보 이용 실태와 만족도)

  • Kim, Inhye;Park, Min-Seo;Bae, Hyun-Joo
    • Journal of Nutrition and Health
    • /
    • v.54 no.4
    • /
    • pp.398-411
    • /
    • 2021
  • Purpose: The objective of this study was to investigate food and nutrition information utilization practices of adults aged between 20 and 30 years to provide the basic data for developing customized content. Methods: Statistical analyses were performed using the SPSS program (ver. 24.0) for the 𝛘2-test, t-test, one-way analysis of variance, and Duncan's multiple range test. Results: Of the 570 subjects surveyed, 45.4% were men, 54.6% were women, 66.3% were in their 20s, 33.7% were in their 30s, 41.4% were single-person households, and 58.6% lived with their families. On average, 14.2% of televisions (TVs), 26.0% of personal computers (PCs), and 63.7% of smartphones were used for more than three hours per day. 30.9% of respondents searched for food and nutrition information more than once a week. 70.0% of the respondents had then applied the information in real life and 54.7% of the respondents said they would share information with others. Information retrieval rate was in the order of 'restaurant (64.8%)', 'diet (57.5%)', and 'food recipes (55.7%)'. Overall satisfaction with food and nutrition information averaged 3.33 on a five-point scale. Satisfaction score was in the order of 'enough description and easy to understand (3.43)', 'matching title and content (3.35)', and 'providing new and novel information (3.22)'. Satisfaction scores were significantly higher in the group that searched for information (p < 0.001), the group that used the retrieved information in real life (p < 0.001), and the group that conveyed this information to others (p < 0.001). Conclusion: To improve information user satisfaction, it is necessary to provide customized information that fits the characteristics of information users. For this purpose, it is necessary to continuously conduct surveys and satisfaction evaluations for each target group.