• Title/Summary/Keyword: taper

Search Result 657, Processing Time 0.036 seconds

Photorefractive volume hologram recording by single-mode fiber with irregularly etched facet (식각된 불규칙 단면을 갖는 단일모드 광섬유를 이용한 광굴절 체적 홀로그램의 기록)

  • 김기현;강용훈;이병호
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.11
    • /
    • pp.48-53
    • /
    • 1997
  • Volume hologram was recorded using reference beam form optical fiber taper. A singel mode fiber was chemically etced to make a taper structure, and we showed experimentally that the referencing by the irregular beam pattern from this taper structure could increase the storage density of photorefractive volume hologram. The spatial selectivity of the volume hologram with this method was increased by two times compared to the normal single mode fiber referencing case. A theoretical analysis with randomly phased plane model also confirmed the results.

  • PDF

A Design of Enhanced Bandwidth Bow-tie Slot Antenna with Tapered Feeder Line (대역폭 개선을 위한 Taper 형태의 급전선로를 갖는 Bow-tie 슬롯 안테나의 설계)

  • 황석진;윤현보
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.127-131
    • /
    • 2001
  • 본 논문에서는 공진 주파수가 2 GHz 이며 크기가 작고, 광대역 특성을 갖는 Taper 형태의 급전선로를 갖는 마이크로스트립 Bow-tie 슬롯 안테나를 제안하였다. 이 구조에서는 대역폭을 향상시키기 위하여 마이크로스트립 슬롯 안테나 방사 슬롯을 변형된 bow-tie 모양으로 설계하여 기존의 Bow-tie 슬롯 안테나와 다른 구조를 제안하였고 Electromagnetic coupling를 좋게 하기 위하여 급전선로에 Taper를 첨가하여 급전기와 안테나의 정합을 이루어 광대역 특성을 갖도록 하였다.

  • PDF

Transient Response of The Optimal Taper-Flat Head Slider in Magnetic Storage Devices

  • Arayavongkul, R.;Mongkolwongrojn, M.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.990-994
    • /
    • 2004
  • This paper presents a method to predict the transient characteristic of the air lubricated slider head in a hard disk drive by using optimization technique. The time dependent modified Reynolds equation based on the molecular slip flow approximation equations was used to describe the fluid flow within the air bearing and the implicit finite difference scheme is applied to calculate the pressure distribution under the slider head. The exhaustive search combined with the Broyden-Fletcher-Goldfarb-Shanno method were employed to obtain optimum design variables which are taper angle, rail width and taper length in order to keep the forces and moments acting on the slider head in dynamic equilibrium. The results show that the optimal head slider of the magnetic head has good stability characteristic that can reach the steady state within 0.5 microsecond.

  • PDF

Numerical Analysis on the Flow and Heat Transfer Characteristic of Wood-flour-filled Polypropylene Melt in an Extrusion Die (목분 충진 고분자 용융체의 압출다이 내 유동 및 열전달에 관한 수치해석)

  • Ko, Seung-Hwan;Park, Hyung-Gyu;Song, Myung-Ho;Kim, Charn-Jung
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.311-318
    • /
    • 2001
  • A three-dimensional numerical analysis of the flow and heat transfer characteristic of wood-flour-filled polypropylene melt in an extrusion die was carried out Used for this analysis were Finite Concept Method based on FVM, unstructured grid and non-Newtonian fluid viscosity model. Temperature and flow fields are closely coupled through temperature dependent viscosity and viscous dissipation. With large Peclet, Nahme, Brinkman numbers, viscous heating caused high temperature belt near die housing, Changing taper plate thickness and examining some predefined parameters at die exit investigated the effect of taper plate on velocity and temperature uniformities. In the presence of taper plate, uniformity at die exit could be improved and there existed an optimum thickness to maximize it.

  • PDF

Control of Taper Shape in Micro-Hole Machining by Micro-EDM (방전 가공을 이용한 미세 구멍 가공 시 발생하는 테이퍼 형상의 제어)

  • Kim Dong Jun;Yi Sang Min;Lee Young Soo;Chu Chong Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.4
    • /
    • pp.52-59
    • /
    • 2005
  • When a micro hole is machined by EDM with a cylindrical electrode, the hole diameter is different at the inlet and the outlet of the micro hole. The taper shape of the micro hole is caused by not only wear of the electrode but the eroded particles. The eroded particles cause secondary discharge during machining the micro hole. As a result, the diameter of the inlet becomes larger than that of the outlet. In this paper, a new method is proposed to reduce the difference in diameter between the inlet and the outlet of the hole. Observed was that the feed depth and machining time affect the formation of taper shape On this experimental basis, ultrasonic vibration was applied to reduce machining time, and capacitance was changed during machining to use the difference in discharging energy of different capacitances. Using the proposed method, a straight micro-hole was fabricated.

A Basic Study on the Surface Roughness in Turning Process Considering Taper Angle Variation (선삭공정의 각도변화가 표면거칠기에 미치는 영향에 관한 기초 연구)

  • Kim, Dong-Hyeon;Choi, Jun-Young;Lee, Choon-Man
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.16-21
    • /
    • 2011
  • In machining operation, the quality of surface finish is an important factor for many turned products. In this paper, surface quality in turning machining considering angle variation has been investigated. To reach this goal, surface quality turning experiments are carried out according to cutting conditions with angle variation. The variable cutting conditions are cutting speed, feed rate and taper angle of workpiece. The surface roughness was measured and the effects of cutting conditions were analyzed by the method of analysis of variance (ANOVA). From the experimental results and ANOVA, it is found that a better surface roughness can be obtained as decreasing feed rate, increasing cutting speed. Taper angle variation has been more influenced by feed rate and cutting speed.

Elastic Critical Loads of Tapered Compression Members with Simply Supported Ends (단순지지 변단면 압축재의 임계하중)

  • Song, Chang-Young
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.5
    • /
    • pp.83-87
    • /
    • 2007
  • Elastic critical loads of sinusoidally tapered bars with simply supported ends are determined by finite element method. The parameters considered in the analysis are taper parameter (=a) and section property parameter (=m). The analysis result for the special case of porismatic bar (a=0) shows good agreement with the existing value. The changes of the critical load coefficients are expressed by an algebraic equation. The coefficients appearing in the equations are determined by regression technique. The critical loads coefficients estimated by the proposed equations reveal little errors when they are compared with those determined by finite element method.

  • PDF

Comparison of Two Taper Functions in Estimating the Volume of Chamaecyparis obtusa Trees Using Centroid Method (중심치 방법을 이용한 편백림 간재적 추정을 위한 간곡선식의 비교)

  • Lee, Young-Jin;Kim, Hyung-Ho
    • Journal of agriculture & life science
    • /
    • v.43 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • This study was conducted to compare volumes estimated from two taper functions and observed volumes of Chamaecyparis obtusa trees to evaluate accuracy and precision of centroid method. Centroid volume estimates were also compared with volume estimates from existing Forest Resources Evaluation and Prediction Program. The results of this study showed that Gregoire's simple taper function produced unbiased volume estimates while the others were biased. Volume estimates from the Forest Resources Evaluation and Prediction Program were also biased when applied in the Jangseong National Forest regions. These results suggested that the centroid method could produce reliable stem volumes of trees when no other reliable stem volume equations exist.

Study on Atomization Characteristics of Shear Coaxial Injectors (전단동축형 분사기들의 미립화 특성에 대한 연구)

  • Ahn, Jonghyeon;Lee, Keunseok;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.26 no.1
    • /
    • pp.9-17
    • /
    • 2021
  • Six shear coaxial injectors with different recess length and taper angle were manufactured. Cold-flow tests on the injectors were performed at room temperature and pressure using water and air as simulants. By changing the water mass flow rate and air mass flow rate, spray images were taken under single-injection and bi-injection. Breakup length and spray angle were analyzed from instantaneous and averaged spray images using image processing techniques. For all the injectors, the breakup length generally decreased as the momentum flux ratio increased at the same gas mass flow rate. The injectors with 7.5° taper angle usually had the longest breakup length and the smallest spray angle. When the taper angle was 15° or more, it hardly affected breakup length and spray angle. The recess length did not influence breakup length but its effect on spray angle depended on the taper angle.

The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.301-308
    • /
    • 2017
  • Objectives: It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Materials and Methods: Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. Results: PTG showed significantly higher NCF than PTU and PTN in group 1 (p < 0.05). Sterilization significantly increased the NCF of PTN and PTG (p < 0.05) in group 2. PTN in group 3 had significantly higher cyclic fatigue resistance than PTN group 4 (p < 0.05). Also, significantly higher NCF was observed for PTG in group 2 than in groups 3 and 4 (p < 0.05). Conclusions: PTG instrument made of new gold alloy was more resistant to fatigue failure than PTN and PTU. Autoclaving increased the cyclic fatigue resistances of PTN and PTG.