• Title/Summary/Keyword: tap water

Search Result 889, Processing Time 0.026 seconds

Particle Separation and Flotation Efficiency by Dissolved Carbon Dioxide Flotation Process (용존이산화탄소부상(DCF) 공정의 입자분리 특성과 부상효율)

  • Kwak, Dong-Heui;Kim, Seong-Jin;Jung, Heung-Jo;Park, Yang-Kyun;Yoo, Young-Hoon;Lee, Young-Dong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.471-478
    • /
    • 2011
  • A series of laboratory experiments carried out to investigate the particle separation efficiency and flotation characteristics using $CO_2$ bubbles. The primary objective of this study was to find out the feasibility of $CO_2$ bubbles as an applicable unit of flotation process in tap-water and wastewater treatment plant. The fundamental measurements were conducted to characterize the $CO_2$ bubble from the physical viewpoint in water including bubble size distribution and rising velocity under various operational conditions. In addition, the removal efficiency of solid was experimented using the lab scale plant applied $CO_2$ bubbles, namely the dissolved carbon dioxide flotation (DCF) process. The DCF process using carbon dioxide bubble, which is an advantage as the decrease and the reuse of Green-House gas, can be a promising technology as an water treatment process. On the other hand, the further research to decrease the bubble size distribution of $CO_2$ is required to enhance the particle separation efficiency.

Hydro-thermal Numerical Simulation for an Artificial Recharge Test in a Fractured Rock Aquifer (암반대수층 지하수 인공함양 시험에 대한 열-수리 모델링)

  • Park, Daehee;Koo, Min-Ho;Kim, Yongcheol
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.1
    • /
    • pp.65-75
    • /
    • 2015
  • An artificial recharge test aimed at investigating transport characteristics of the injected water plume in a fractured rock aquifer was conducted. The test used an injection well for injecting tap water whose temperature and electrical conductivity were different from the groundwater. Temporal and depth-wise variation of temperature and electrical conductivity was monitored in both the injection well and a nearby observation well. A highly permeable fracture zone acting as the major pathway of groundwater flow was distinctively revealed in the monitoring data. A finite element subsurface flow and transport simulator (FEFLOW) was used to investigate sensitivity of the transport process to associated aquifer parameters. Simulated results showed that aperture thickness of the fracture and the hydraulic gradient of groundwater highly affected spatio-temporal variation of temperature and electrical conductivity of the injected water plume. The study suggests that artificial recharge of colder water in a fractured rock aquifer could create a thermal plume persistent over a long period of time depending on hydro-thermal properties of the aquifer as well as the amount of injected water.

Development of Three-Way Proportional Control Valve and Performance Study (3방 비례제어 조절밸브 개발 및 성능 연구)

  • Lee, Jonghwa;Jung, Taeksu;Cho, Chongdu;Kim, Jooyong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.218-223
    • /
    • 2014
  • Korea District heating corp. recently give an attention to combine the district heating and supply pipes as a two pipe system that are in the present system separated with room heating and warm water supply pipe, and the two pipe system is commonly applied for heating service in European countries. In the new two pipe system, only one heat source is supplied to a house and partitioned into room heating and warm water supply by household substation. So the effective distribution of supplied heat source in accordance to user intention is very important. This paper presents the development and performance test of three-way proportional control valve for a combined heat source system in district heating. The proposed valve is controlled to partition heat source into two different directions : hot water distributor for space heating and household substation for warm water supply in response to the pressure drops of tap water caused by the user. The performance investigation is shown within 3% of error compared to the theoretical model of the three-way proportional valve and its controllability is verified.

Effect of electrolyte on Bow-tie Water tree (Electrolyte 가 Bow-tie 형 수트리에 미치는 영향)

  • Kang, T.O.;Yang, W.Y.;Kim, K.S.;Chun, C.O.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1550-1552
    • /
    • 1994
  • In order to investigate the effect of electrolyte solutions on the activities of bow-tie water trees in XLPE insulated power cable, we have tried to observe the characteristics on water treeing ( bow-tie type ) using several electrolyte solutions such as $CH_3COOH$, $MgCl_2$,HCl and NaCl solution and tap water. Bow-tie tree density in $CH_3COOH$ and $MgCl_2$ solution was higher than in any other solution, and the growth of tree was stimulated in NaCl and $CH_3COOH$ solution, and diffusion of bow-tie trees into insulation in $MgCl_2$, HCl and NaCl solutions was faster than in $CH_3COOH$ solution and water. Also, although the increase of applied voltage caused bow-tie tree density to be high, it didn't affect the growth of tree maximum length noticeably.

  • PDF

Measurement of Microbic Contamination Rate in the Dispensing Process Making Suspension of Barium Sulfate Powder (분말 형태의 황산바륨을 현탁액으로 조제하는 과정에서 발생하는 미생물의 오염도 측정)

  • Kim, Young-Keun;Lee, Yang-Sub;Cho, Cheong-Chan;Ryu, Meung-Sun;Lee, Kyung-Sup
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.53-57
    • /
    • 2001
  • The purpose of this study is to investigate the contamination rate of barium sulfate suspension made in the exposed state in usual circumstances. This study was performed in four university hospital using the contrast media by barium sulfate powder. The specimen were detected at dispensing water, agitator and mixing tank. We also classified the suspension into general bacteria, mycete, and Bacillus coli infection. The tap water were used to dispense water in the all hospitals. Bacillus colt were not detected in the all. General bacteria and mycete were not detected in the one specimen, but detected in two specimen over defined value. In the contamination rate of agitator, mixing tank, and the manufactured, Bacillus coli were not detected in all. However, general bacteria and mycete were detected too numberous to count. In conclusion, the refined water must be used in dispensing water in manufacturing suspension. The disinfectant is also used in washing the agitator and mixing tank for sterilization. Hand washing is indispensible to manufacturing suspension for preventing from infection.

  • PDF

A Study on the Water Saving Effect in Case of Raising Water Rate Depends on Water Rate Awareness (수돗물 가격 인식에 따른 수도요금 인상 시 물 절약 효과)

  • Lim, Sang-Ho;Han, Moo-Young
    • Industry Promotion Research
    • /
    • v.1 no.1
    • /
    • pp.129-135
    • /
    • 2016
  • This study verified the water saving effect in case of raising water rate depends on water rate awareness. The study results showed that the perceived appropriacy of government aid(p<.001), home water rate(p<.01), water rate pricing system, water rate, water rate diffrences depend on use and area(p<.05) significantly affected the degree of agreement of raising water rate. Also, education, residence, member of household, occipation, monthly household income, monthly water rate significantly affected the degree of agreement of raising water rate, consumer behavior for saving water. This study provided implication for water rate pricing policy by analyzing the water saving effect in case of raising water rate depends on water rate awareness and revealing the determinants of the degree of agreement of raising water rate.

The Optimal Enrichment Condition of Rotifer Brachionus rotundiformis (소화효소 활성으로 본 rotifer Brachionus rotundiformis의 적정 영양강화 조건)

  • Kwon, O-Nam;Park, Heum-Gi
    • Journal of Aquaculture
    • /
    • v.21 no.1
    • /
    • pp.41-46
    • /
    • 2008
  • The purpose of the study was to suggest the optimal lipid enrichment conditions used digestive enzyme activity of rotifer changing due to water temperature and salinity. The high population growth appeared at the experiment temperature more than 28 degrees highly on the culture temperature(maximum 32 degrees, 1,453 individual/mL). The fecundity was low at high temperature, and the egg ratio was high at low temperature. Population growth of 10 and 15 ppt appeared in most highly, but the fecundity and the egg ratio were high most significantly appeared in natural seawater(32 psu). The digestive enzyme activity by the culture environment mainly showed high activity in natural seawater(amylase exclusion, 15 psu). However, the TAP activity by the water temperature showed highly at the more high temperature, but the amylase and the lipase appeared at low temperature. We carried out the lipid enrichment at 20 degrees and 26 degrees in a condition of the natural seawater. Total protein, the total essential amino acids differed not significantly. The methionine content that was essential amino acids, a total lipid content, unsaturated index of fatty acids, DHA and the DHA/EPA ratio were high significantly each in $20^{\circ}C$ enrichment trial. Therefore, we could suggest the $20^{\circ}C$ and natural seawater for the optimal lipid enrichment condition in aquaculture, because methionine contents, several indexes by the lipid, TG-lipase activity, fecundity and egg ratio are high.

Cost analysis of water supply and development of desalination vessel as a drought response (가뭄 시 광역자치단체 별 물 비용 분석 및 해상 이동형 담수화 플랜트 이용 대응 방안 연구)

  • Yang, Hayeon;Koo, Jaewuk;Hwang, Taemun;Jeong, Seongpil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • Due to global climate change, Korea is experiencing flooding and drought severely. It is hard to manage water resources because intensive precipitation during short periods and drought are commonly occurred in Korea, recently. Severe drought occurred in 2015 and 2017 in the islands, and coastal and inland areas in Korea, and the citizens experienced decreased water supply and emergency water service by using bottled water. Therefore, the Korean government provided additional governmental funds such as the grant of drought disaster. In this study, we tried to calculate the cost of water for drought response based on the cost of tap water for the regional local governments in Korea and the grant of drought disaster by the Ministry of the Interior and Safety in Korea, etc. The estimated costs of water for drought responses in coastal and inland areas which have a chance to apply alternative water sources such as brackish or seawater desalination and water reuse in Korea were higher than in other areas in Korea. Additionally, as the novel approach of drought response, the 300 ㎥/day-scale desalination vessel was suggested to provide desalinated water for the islands in Korea. The estimated expenses of water supply for the target island areas (Sinan-gun and Jindo-gun) by the desalination vessel was lower than those by emergency water service by using bottled water.

Prioritization decision for hazard ranking of water distribution network by cluster using the Entropy-TOPSIS method (Entropy-TOPSIS 기법을 활용한 군집별 상수도관망 위험도 관리순위 결정)

  • Park, Haekeum;Kim, Kibum;Hyung, Jinseok;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.517-531
    • /
    • 2021
  • The water supply facilities of Korea have achieved a rapid growth, along with the other social infrastructures consisting a city, due to the phenomenon of urbanization according to economic development. Meanwhile, the level of water supply service demanded by consumer is also steadily getting higher in keeping with economic growth. However, as an adverse effect of rapid growth, the quantity of aged water supply pipes are increasing rapidly, Bursts caused by pipe aging brought about an enormous economic loss of about 6,161 billion won as of 2019. These problems are not only worsening water supply management, also increasing the regional gap in water supply services. The purpose of this study is to classify hazard evaluation indicators and to rank the water distribution network hazard by cluster using the TOPSIS method. In conclusion, in this study, the entropy-based multi-criteria decision-making methods was applied to rank the hazard management of the water distribution network, and the hazard management ranking for each cluster according to the water supply conditions of the county-level municipalities was determined according to the evaluation indicators of water outage, water leakage, and pipe aging. As such, the hazard ranking method proposed in this study can consider various factors that can impede the tap water supply service in the water distribution network from a macroscopic point of view, and it can be reflected in evaluating the degree of hazard management of the water distribution network from a preventive point of view. Also, it can be utilized in the implementation of the maintenance plan and water distribution network management project considering the equity of water supply service and the stability of service supply.

Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment (공동주택 지하저수조의 수질변화 및 부식성 특성)

  • JunYoung, Jang;JooWon, Kim;YuHoon, Hwang;KiPal, Kim;HyunSang, Shin;ByungRan, Lim
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.275-281
    • /
    • 2022
  • To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.