• 제목/요약/키워드: tap water

검색결과 889건 처리시간 0.031초

Determination of Polonium Nuclides in a Water Sample with Solvent Extraction Method

  • Lee, M.H.;Lee, C.H.;Song, K.;Kim, C.K.;Martin, P.
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권9호
    • /
    • pp.2488-2492
    • /
    • 2010
  • A method is described for the determination of the Po nuclides in a water sample. After the Po nuclides were purified from interfering elements in a water sample using a manganese dioxide precipitation followed by a solvent extraction method, the Po nuclides were deposited onto the silver plate. A large volume of the water sample was effectively pretreated with manganese dioxide precipitation method. To determine the optimum conditions for plating Po, the effects of the pH, volume, temperature and time on the Po deposition were investigated in hydrochloric acid solution. The investigated determination method of Po nuclides with solvent extraction was applied to a tap water sample.

총유기탄소의 먹는물 수질기준 설정 연구 (A Study on the Establishment of Total Organic Carbon in Drinking Water Standard)

  • 유순주;안경희;박수정;김미아;최자윤;이연희
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.661-666
    • /
    • 2009
  • In this study, total organic carbon (TOC) and potassium permanganate ($KMnO_4$) demand were examined for raw and finished tap water and the range of $KMnO_4$ demand in drinking water was investigated. By analyzing the relationship between TOC and $KMnO_4$ demand, the applicability of TOC as a drinking water standard and its regulation level was proposed. The average $KMnO_4$ demand was 1.3 mg/L in 4,638 samples from finished drinking water, tap water and finished water from small facilities. $KMnO_4$ demand of 95% of samples was 2.9 mg/L which was 29% of the drinking water standard (10 mg/L). At 12 major drinking water treatment plants, the average $KMnO_4$ demand in July and August was 8.1 and 2.4 mg/L for raw and finished water, respectively. TOC in July and August was 2.0 and 1.15 mg/L for raw and finished water, respectively. The correlation coefficient between $KMnO_4$ demand and TOC was as high as 0.8 in both raw and finished water and $KMnO_4$ demand was twice of TOC in finished water. Because the correlation coefficient and ratio between $KMnO_4$ demand and TOC varied according to season and the characteristics of raw water, it would be difficult to establish TOC standard just from the ratio of $KMnO_4$ demand to TOC. However, it is possible to set the TOC range based on the accumulated $KMnO_4$ demand data or from the satisfactory correlation results. Then, it would be reasonable to establish TOC standard level as 4 ~ 5 mg/L.

담금수의 수질이 열무 물김치의 비타민 C 함량에 미치는 영향 (Effect of the Water Quality on the Variation of Ascorbic Acid Content during Yulmoo Mul-kimchi Fermentation)

  • 김유진;오지영;이태녕;한영숙
    • 한국식품과학회지
    • /
    • 제30권1호
    • /
    • pp.175-183
    • /
    • 1998
  • 비타민 C 고함량의 물김치를 제조하기 위한 방법의 하나로 담금수의 종류를 달리하여 지하수, 1차증류수, 3차 증류수, 생수 및 수돗물의 금속이온(Ca, Mg, Fe, K, Na, Cu) 함량을 분석하였으며, 각각의 물로 열무 물김치를 제조하여 $15^{\circ}C$에서 발효 숙성시키면서 그 담금수가 김치의 숙성지표인 pH와 산도의 변화에 미치는 영향을 밝히고, 총 비타민 C함량, 텍스쳐 및 미생물 균수의 변화를 살펴봄과 동시에 관능검사를 실시한 결과는 다음과 같았다. 각 담금수의 금속이온 함량을 측정한 결과, 전반적으로 3차 증류수가 금속이온 함량이 가장 낮은 반면 수돗물은 금속이온 함량이 가장 높았고, 특히 Cu 이온이 검출되었으며, 지하수의 Ca함량은 다른 담금수에 비해 월등히 높았다. 각 담금수로 제조한 김치국물의 pH와 산도 및 미생물의 변화는 김치시료간에 큰 차이를 보이지 않았고, 열무 줄기로 측정한 텍스쳐는 시료간에 큰 차이를 보이지 않았으나 담금 3일까지 증가하였다가 그 이후 감소하는 경향을 보였다. 한편, 총 비타민 C 함량은 3차 증류수로 제조한 김치국물의 숙성 적기 총 비타민 C함량이 7.20 mg%로 최고 함량을 나타내었고, 그 다음이 지하수로 제조한 김치로 5.72 mg%를 나타내었으며, 수돗물로 제조한 김치의 총 비타민 C 함량은 3.37 mg%로 가장 낮아 3차 증류수로 제조한 김치의 50%에 불과했다. 또한, 기호도를 조사한 결과, 3차 증류수로 제조한 김치의 기호도가 가장 높았고 그 다음이 생수로 제조한 김치였으며, 지하수로 제조한 김치의 기호도가 가장 낮았다.

  • PDF

분리막을 이용한 무전해 PCB 도금 폐수의 재활용 (Wastewater Recycling from Electroless Printed Circuit Board Plating Process Using Membranes)

  • 이동훈;김래현;정건용
    • 멤브레인
    • /
    • 제13권1호
    • /
    • pp.9-19
    • /
    • 2003
  • 무전해 PCB 도금 공정 수세액을 분리막으로 처리하여 투과수는 공업용수로 재사용하고 유가금속인 금(Au)을 회수하는 방법에 관하여 연구하였다. 역삼투 분리막 테스트 셀을 이용하여 수세액 처리에 적합한 분리막을 선정하였으며 scale-up을 위한 나권형 모듈 투과 실험을 실시하였다. 먼저, (주)새한에서 생산되는 RO-TL(tap water, low pressure), RO-BL(brackish water, low pressure), RO-normal(for water purifier)막으로 투과실험하였으며 그 중 RO-TL막이 soft etching, 촉매 및 Ni 수세액 처리에 우수한 것으로 판명되었다. 따라서 RO-TL막으로 제작한 나권형 가정용 정수기 모듈로 7bar, $25^{\circ}C$에서 scale-up 실험을 수행하였다. Au수세액의 투과 유속은 약 30 LMH로서 가장 높았으나 Au 제거율이 80% 미만이었다. Pd, Ni 및 soft etching 수세액의 투과유속은 각각 약 22, 17, 10 LMH 정도이며 Pd의 제거율은 85% 이상, Ni 및 Cu 제거율은 97% 이상이었다. 또한 Au, Ni 및 Cu 이온이 함유된 수세액 중 유가금속인 Au를 선택적으로 회수하기 위하여 NF막을 사용하였다. Au수세액 중 Ni 및 Cu 이온은 대부분 제거되었으며 투과액 중에 Au이온이 81.9% 존재하였고 계속하여 RO-TL막으로 Au를 농축 회수하였다. 마지막으로 4"직경의 NF 및 RO-TL 나권형 모듈을 연속적으로 사용하여 Au를 효과적으로 회수할 수 있음을 재확인하였다.인하였다.

Development of a Monitoring System for Water-borne Bacteria by a Molecular Technique, PCR-RFLP-sequence Analysis

  • Lee, Ji-Young;Jeong, Eun-Young;Lee, Kyu-sang;Seul-Ju;Kim, Jong-Bae;Kang, Joon-Wun;Lee, Hye-Young
    • 대한의생명과학회지
    • /
    • 제9권3호
    • /
    • pp.139-144
    • /
    • 2003
  • Since water borne infection causes acute diseases and results in spread of diseases by secondary infection, the prevention is very important. Therefore, it is necessary to have a method that is rapid and effective to monitor pathogenic bacteria in drinking water. In this study, we employed a systematic method, Polymerase Chain Reaction-Restriction Fragment Length Polymorphism (PCR-RFLP) analysis, to develop an effective monitoring system for possible bacterial contaminants in drinking water. For this purpose, PCR primers were derived from 992 bp region of the 16s rRNA gene that is highly conserved through the different species of prokaryotes. To test whether the PCR primers designed are indeed useful for detecting all the possible microbial contaminants in the water, the primers were used to amplify 16s rRNA regions of different microbial water-borne pathogens such as E. coli, Salmonella, Yersinia, Listeria, and Staphylococcus. As expected, all of tested microorganisms amplified expected size of PCR products indicating designed PCR primers for 16s rRNA indeed can be useful to amplify all different microbial water-borne pathogens in the water. Furthermore, to test whether these 16s rRNA based PCR primers can detect bacterial populations present in the water, water samples taken from diverse sources, such as river, tap, and sewage, were used for amplification. PCR products were for then subjected for cloning into a T-vector to generate a library containing 16s rRNA sequences from various bacteria. With cloned PCR products, RFLP analysis was done using PCR products digested with restriction enzyme such as Hae III to obtain species-specific RFLP profiles. After PCR-RFLP, the bacterial clones which showed the same RFLP profiles were regarded as the same ones, and the clones which showed distinctive RFLP profiles were subsequently subjected for sequence analysis for species identification. By this PCR-RFLP analysis, we were able to reveal diverse populations of bacteria living in water. In brief, in unsterilized natural river water, over 60 different species of bacteria were found. On the other hand, no PCR products were detected in drinking tap-water. The results from this study clearly indicate that the PCR-RFLP-sequence analysis can be a useful method for monitoring diverse, perhaps pathogenic bacteria contaminated in water in a rapid fashion.

  • PDF

통합 수질계측 시스템 개발 (A development of integrated water-quality measurement system)

  • 양근호
    • 융합신호처리학회논문지
    • /
    • 제8권3호
    • /
    • pp.211-216
    • /
    • 2007
  • 대형 정수장에서 개인수도꼭지까지 전체 급수 설비에서 수질은 반드시 먹는 물 수질기준을 만족해야 한다. 그러나 현재까지도 수돗물의 공급과정은 과학적으로 모니터링 되거나 관리되지 못하고 있다. 수돗물 특히 대부분의 작은 규모의 정수장은 항상 다양한 오염원 및 불순물 등에 노출되어 있다. 최근 일부 대형 정수장이나 배수지 등에 수질감시 시스템이 사용되고 있다. 특히 인터넷을 이용한 수질 모니터링 방법이 일부 지방자치단체에 도입되었으며 이 시스템은 해당 지역주민들이 언제 어디서나 수질을 확인할 수 있도록 되어있다. 그러나 이 시스템, 즉 대형 시스템에 사용되는 이 방법은 매우 높은 비용을 필요로 하고 이로 인해 아파트, 공공시설, 소규모의 지하저수조 및 고가(高架)저수조와 같은 소규모 급수설비에는 적용하기가 곤란하다. 따라서 본 연구에서는 저가의 개별 수질측정 센서모듈에 대한 통합시스템을 제안한다. 개발된 통합 시스템과 인터넷상에서 동작하는 모니터링 프로그램을 이용하여 저수조 시스템 관리자는 음용수에 대한 수질 특성치를 실시간으로 관리할 수 있다. 또한 제안된 시스템이 모듈화 되어있기 때문에 크고 작고의 규모에 관계없이 저비용으로 다양한 저수조나 정수장에 쉽게 설치할 수 있다.

  • PDF

침지형 다항목 수질계측기 및 원격 모니터링 시스템 개발 (A development of submerged type multiprobe water-quality measuring instrument and remote monitoring system)

  • 양근호
    • 융합신호처리학회논문지
    • /
    • 제10권3호
    • /
    • pp.207-213
    • /
    • 2009
  • 정수장에서 수도꼭지까지 전체적인 물 공급 체계에서 수돗물의 수질은 먹는 물 기준에 적합해야 하지만 수돗물 공급과정에서 수질 모니터링과 충분한 관리가 이루어지지 않고 있다. 특히 대부분의 소규모 저수조(지하저수조 또는 고가(高架)저수조)의 수도관은 다양한 오염원에 노출되어 있다. 최근의 수질 모니터링 시스템은 몇몇 대형 정수장과 배수지 등에 설치되어 운영하고 있다. 특히 인터넷을 이용한 수질 모니터링은 언제 어디서나 주민들이 확인할 수 있도록 몇몇 지방자치단체에서 채택하고 있다. 이러한 시스템을 구축하는 것은 대규모 시설을 필요로 하기 때문에, 아파트, 공공건물, 소규모 지하저수조 또는 고가저수조와 같은 규모가 적은 물 공급시설에는 제한적으로 적용된다. 본 연구에서는 저렴한 각각의 수질센서 모듈을 집적화하여 개발한 다항목 수질계측기를 이용하여 인터넷에서 운용되는 온라인 모니터링 프로그램을 개발하였다. 저수조 관리자는 온라인으로 먹는 물의 수질 측정값을 모니터링할 수 있다. 제안된 다항목 수질측정기를 집적화하였으며, 저수조의 크기와 관계없이 저가로 다양한 저수조에 쉽게 적용할 수 있는 시스템이다.

  • PDF

Methods for the Extraction of DNA from Water Samples for Polymerase Chain Reaction

  • Jung, Jae-Sung;Lee, Young-Jong
    • Journal of Microbiology
    • /
    • 제35권4호
    • /
    • pp.354-359
    • /
    • 1997
  • Methods for the extraction of DNA from water sample were approximated. Four different procedures of DNA extraction were carried out with pellets obtained from centrifugation of 4 liter water samples. The recovery efficiency and purity of DNA extracted by each method from different sources were compared. DNA yield varied with extraction methods, Method I, which involves enzymatic and freeze-thaw lysis steps and phenol and phenol-chloroform purification of extracted nucleic acid, showed a significantly higher yield and purity than the other methods. The use of glass beads in the DNA extraction methods improved the purity of DNA suitable for PCR. Bovine serum albumin in the PCR reaction mixture was useful in reducing inhibitory effects of contaminants. The efficiency of an extraction method was determined by the detection of the aer of Aeromonas hydrophila with PCR. The lower limit of detection of A. hydrophila from seeded tap water was 2 CFU/ml in PCR when method I was used for DNA preparation.

  • PDF

임진강수계의 수질조사 및 개선방안 (A Survey of Water Quality and Improvement Measure of Imjin-River)

  • 김형진;백영석;이준석
    • 환경위생공학
    • /
    • 제10권1호
    • /
    • pp.66-75
    • /
    • 1995
  • This survey is executed about the water quality and improvement measure of Imjin- river. The results are summarized as follows; 1 ) Ammonia nitrogen concentration in tap water was two times higher than drinking water standard. 2) The concentration of BOD in textile wastewater was 235ppm which is higher than wastewater distribution standard and leather wastewater showed high nitrogen concentration. 3) Water quality of the Imjin- river upstream was not in problem but that of Shin- stream showed somewhat high concentration in BOD, COD, and ammonia nitrogen. Especially the detected Cynide compound on the lower of Shin- stream implied seriously polluted condition. 4) The heavy metal in soil of the river bed was not detected but iron, zinc was detected to high concentration. 5) It Is urgently suggested to build more municipal sewage and sanitary treatment plants, and run dredging and river bed rearrangement project. 6) The Construction of the wastewater treatment complexes of relevant industries shall be propelled as soon as possible.

  • PDF

단체급식소에서 이용되는 일부 생채소의 소독방법 및 저장에 따른 품질연구 (A study for the Quality Depending on Sanitization and Storage Method of Raw Vegetables in Foodservice Operation)

  • 김혜영
    • 한국식품조리과학회지
    • /
    • 제20권6호
    • /
    • pp.684-694
    • /
    • 2004
  • The purpose of this study was to estimate the microbial and physicochemical quality of some raw vegetables and suggest safer methods of sanitization and storage for foodservice operations. Three sanitization methods were utilized during pre-preparation (tap water, chlorine water and electrolyzed water). Leek and Chicory were monitored as ingredient, with different storage temperatures $(3,\;10^{\circ}C)$ and periods (1, 2, 3, 4 and 7 days). The largest reduction in the microbial counts was shown with the electrolyzed water and for the case before immersion in chlorine water, performing a first washing was more effective in reducing the microbial counts than with no washing. The results showed that the storage temperature, pH, moisture content and microbial loads were important factors affecting the quality of vegetables.