• Title/Summary/Keyword: tap water

Search Result 888, Processing Time 0.023 seconds

Study on the durability improvement of GFRP composites in alkaline environment (1) (알칼리 환경에 대한 GFRP 복합재료의 내구성 향상에 관한 연구(1))

  • Park, Chang-Ho;Kim, Hyoune-Yul;Park, Young-Hwan;Moon, Chang-Kwon
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.145-149
    • /
    • 2006
  • The effect of alkaline environmental condition on durability of GFRP composites according to additives has been investigated. Additives used were polyvinyl alcohol (PVA), kaolin and alumina powder. Weight gains increased with immersion time in all GFRP composites at $80^{\circ}C$. But weight gain of specimen added PVA did not differ through the whole immersion time in both tap water and alkaline solution at 20 and $80^{\circ}C$. Tensile strength decreased with immersion time in all environment conditions. Tensile strength of GFRP composites regardless of additives decreased rapidly up to 5 days of immersion and then decreased slowly up to 30 days in alkaline solution environment at $80^{\circ}C$. The weight gains were not much difference in both tap water and alkaline solution at $20^{\circ}C$. But the ones of GFRP composites added PVA was smaller than the composites without additive in all aqueous at $20^{\circ}C$. Test strength of GFRP composites added polyvinyl alcohol has improved through the whole immersion time in both tap water and alkaline solution environment at $20^{\circ}C$.

  • PDF

A Study on Comparison of Risk Estimates Among Various Exposure Scenario of Several Volatile Organic Compounds in Tap Water (음용수중 휘발성 유기오염물질의 노출경로에 따른 위해도 추정치 비교연구)

  • Chung, Yong;Shin, Dong-Chun;Kim, Jong-Man;Yang, Ji-Yeon;Park, Seong-Eun
    • Environmental Analysis Health and Toxicology
    • /
    • v.10 no.1_2
    • /
    • pp.21-35
    • /
    • 1995
  • Risk assessment processes, which include processes for the estimation of human cancer potency using animal bioassay data and calculation of human exposure, entail uncertainties. In the exposure assessment process, exposure scenarios with various assumptions could affect the exposure amount and excess cancer risk. We compared risk estimates among various exposure scenarios of vinyl chloride, trichloroethylene and tetrachloroethylene in tap water. The contaminant concentrations were analyzed from tap water samples in Seoul from 1993 to 1994. The oral and inhalation cancer potencies of the contaminants were estimated using multistage, Weibull, lognormal, and Mantel-Bryan model in TOX-RISK computer software. In the first case, human excess cancer risk was estimated by the US EPA method used to set the MCL(maximum contaminant level). In the second and third case, the risk was estimated for multi-route exposure with and without adopting Monte-Carlo simulation, respectively. In the second case, exposure input parameters and cancer potencies used probability distributions, and in the third case, those values used point estimates(mean, and maximum or 95% upper-bound value). As a result, while the excess cancer risk estimated by US EPA method considering only direct ingestion tended to be underestimated, the risk which was estimated by considering multi-route exposure without Monte-Carlo simulation and then using the maximum or 95% upper-bound value as input parameters tended to be overestimated. In risk assessment for volatile organic compounds, considering multi-route exposure with adopting Monte-Carlo analysis seems to provide the most reasonable estimations.

  • PDF

Endosymbionts of Acanthamoeba Isolated from Domestic Tap Water in Korea

  • Choi, Seon-Hee;Cho, Min-Kyoung;Ahn, Soon-Cheol;Lee, Ji-Eun;Lee, Jong-Soo;Kim, Dong-Hee;Xuan, Ying-Hua;Hong, Yeon-Chul;Kong, Hyun-Hee;Chung, Dong-Il;Yu, Hak-Sun
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.4
    • /
    • pp.337-344
    • /
    • 2009
  • In a previous study, we reported our discovery of Acanthamoeba contamination in domestic tap water; in that study, we determined that some Acanthamoeba strains harbor endosymbiotic bacteria, via our molecular characterization by mitochondrial DNA restriction fragment length polymorphism (Mt DNA RFLP). Five (29.4%) among 17 Acanthamoeba isolates contained endosymbionts in their cytoplasm, as demonstrated via orcein staining. In order to estimate their pathogenicity, we conducted a genetic characterization of the endosymbionts in Acanthamoeba isolated from domestic tap water via 16S rDNA sequencing. The endosymbionts of Acanthamoeba sp. KA/WP3 and KA/WP4 evidenced the highest level of similarity, at 97% of the recently published 16S rDNA sequence of the bacterium, Candidatus Amoebophilus asiaticus. The endosymbionts of Acanthamoeba sp. KA/WP8 and KA/WP12 shared a 97% sequence similarity with each other, and were also highly similar to Candidatus Odyssella thessalonicensis, a member of the $\alpha$-proteobacteria. The endosymbiont of Acanthamoeba sp. KA/WP9 exhibits a high degree of similarity (85-95%) with genus Methylophilus, which is not yet known to harbor any endosymbionts. This is the first report, to the best of our knowledge, to show that Methylophilus spp. can live in the cytoplasm of Acanthamoeba.

Analysis of Factors and it's Effectiveness to Maintenance Cost of Public Buildings (공공청사의 운영비용에 영향을 미치는 요인과 요인별 영향력 분석)

  • Ko, Kyujin;Cho, Sangouk;Hwang, Jeongha;Lee, Chansik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.2
    • /
    • pp.29-37
    • /
    • 2015
  • Multi-household buildings are efficiently maintained from the mid- and long-term viewpoint according to the long-term repair coverage system etc. On the other hand, public buildings are not systematically maintained due to a lack of past maintenance cost data and inefficient budget plans, among other problems. Targeting public buildings in Incheon, this study analyzed operation costs variables. To verify the analysis results, they underwent a correlation analysis and a multi-regression analysis. With regard to public buildings electricity, gas and tap water cost, the influence power of the served life, floor area, and workforce were analyzed, revealing that electricity cost was highly correlated with workforce, while gas and tap water cost were correlated with tap water cost. Also, the correlation analysis results were verified through a multi-regression analysis, and a maintenance cost estimation model was presented using a regression equation.

Influence of Filler and Cure Systems on Whitening of EPDM Composites by Formation of Metal Salt (충전 시스템과 가교 시스템이 금속염 형성에 의한 EPDM 복합체의 백화에 미치는 영향)

  • Chung, Hye-Seung;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • v.47 no.3
    • /
    • pp.210-215
    • /
    • 2012
  • Whitening phenomena of the EPDM composites with different inorganic filler compositions which were aged at $90^{\circ}C$ for 7 days in air and tap water atmospheres, respectively, were investigated. The aged samples in tap water containing stearic acid exhibited severe whitening phenomena, while all the samples aged in air did not show any whitening. Depending on the filler compositions, there was no big difference in the whitening phenomena. The whitening materials were analyzed using gas chromatography/mass spectrometry (GC/MS), image analysis, energy-dispersive X-ray spectroscopy (EDX), and attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR). The whitening materials were identified to be salts of stearic acid. The salts of stearic acid were formed by reaction of metal cation in tap water and stearic acid in the sample.

Effects of Chloride and Sulfate Ions on Corrosion Behaviors of Structural Materials Based on Design of Experiment (실험계획에 기반한 수돗물 성분(Chloride and Sulfate Ions)의 구조재료 부식 영향성 고찰)

  • Dong-In Lim;Heng-Su Noh;Hyeok-Jun Kwon;Sung-Ryul Park;Man-Sik Jo;Doo-Youl Lee
    • Corrosion Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.201-213
    • /
    • 2023
  • Corrosion management of an aircraft and its engine relies on rinsing and cleaning using tap water. Few studies have reported effects of tap water species on corrosion behaviors of structural materials. In this study, a series of experiments were conducted based on the design of experiment. Solutions with different levels of chloride and sulfate ions were prepared using a full factorial design. Two structural materials (aluminum alloy and steel) were used for an alternate immersion test. Weight loss was then measured. In addition, a silver specimen was utilized as a sensor for chloride deposition measurement. The silver specimen was examined using the electrochemical reduction method, XPS, and SEM-EDS. Surface analysis revealed that levels of chloride and sulfate ions were sufficient for the formation of silver chloride and silver surface. Statistical analysis of weight loss and chloride deposition rate showed significant differences in measured values. Concentration of chloride ions greatly affected corrosion behaviors of structural materials. Sulfate ion hindered the adsorption reaction. These results emphasize the importance of controlling ion concentration of tap water used for cleaning and rinsing an aircraft.

Natural Reduction Characteristics of Radon in Drinking Groundwater (음용 지하수 중 라돈 자연저감 특성)

  • Noh, Hoe-Jung;Jeong, Do-Hwan;Yoon, Jeong-Ki;Kim, Moon-Su;Ju, Byoung-Kyu;Jeon, Sang-Ho;Kim, Tae-Seung
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.1
    • /
    • pp.12-18
    • /
    • 2011
  • To investigate the natural reduction characteristics of radon with a short half-life (3.82 day) in drinking Qgroundwater, we analyzed the changes of radon concentrations of groundwater, waters in storage tanks, and tap waters from the small-scale groundwater-supply systems (N = 301) by LSC (Liquid Scintillation Counter). We also analyzed the concentrations of uranium (half-life 4.5 billion years) in the waters by ICP/MS to compare with natural reduction of radon concentration. The radon concentrations of 68 groundwater-supply systems occupying 22.6% of the total samples exceeded the US EPA's Alternative Maximum Contaminant Level (AMCL : 4,000 pCi/L), with the average radon concentration of 7,316 pCi/L (groundwaters), 3,833 pCi/L (tank waters) and 3,407 pCi/L (tap waters). Compared to the radon levels of pumped groundwaters, those of tank and tap waters naturally reduced significantly down to about 50%. Especially, in case of 29 groundwater-supply systems with the groundwater radon concentrations of 4,000~6,000 pCi/L, average radon concentrations of the tank and tap waters naturally decreased down to the AMCL. Therefore this study implies that radon concentrations of drinking groundwater can be effectively reduced by sufficient storage and residence in tanks.

Study on the Effect of Washing with Water and Detergent on the Vitamin C Content in Fruit and Vegetable (세정 및 세제사용이 야채 및 과일의 비타민 C 함량에 미치는 영향)

  • 이용욱
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.2
    • /
    • pp.55-60
    • /
    • 1993
  • This study was performed to investigate the effect of washing with water and detergent on the vitamin C content in strawberry and perilla leaf. Vitamin C was extracted with the solution of metaphosphoric acid and quantitated by high performance liquid chromatograph (HPLC). There was no significant difference of vitamin C content between the washing with distilled water and tap water. Three available detergents reduced the vitamin C content of samples to 92.5%, 92.2% and 78.5%, respectively. The content of vitamin C in samples was decreased by increasing the concentration of detergent and washing time.

  • PDF

Study on the Cathodic Protection Characteristics of Hot Water Boiler by Mg-Alloy Galvanic Anode(1) (Mg 합금 유전양극에 의한 온수Boiler의 음극방식특성에 관한 연구(1))

  • 임우조;윤병두
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.147-152
    • /
    • 2001
  • Corrosion damage of boiler, factory equipment and so forth occur quickly due to using of the polluted water, resulting in increasing leak accident. Especially, working life of hot water boiler using the polluted water becomes more short, and energy loss increases. The cathodic protection method is the most economical and reliable one to prevent corrosion damage of steel structures. Mg-base alloys galvanic anode protection of cathodic protection methode is suitable for the application of hot water boiler using water with high specific resistance such as tap water. This paper is studied on the cathodic protection characteristics of hot water boiler. In tap water solution, the measurement of cathodic protection potential according to the time elapsed is carried out, and behavior of cathodic polarization with current change is investigated. The main results obtained are as follows. In hot water boiler shell, the open circuit potential of base metal become less noble than that of weld Bone, and the current density of base metal becomes low than that of weld zone. The further distance from Mg-alloy galvanic anode, the higher cathodic protection potential of hot water boiler appears. And protective potential becomes high according to pass cathodic protection time and after 6∼10 days become stable.

  • PDF

Effect of Clay on the Growth and Changes of Mineral Contents of Soybean Sprout (점토광물이 콩나물의 생장과 미네랄 함유량에 미치는 영향)

  • Choi, Heejeong;Lee, Seungmok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.8
    • /
    • pp.29-35
    • /
    • 2013
  • The objective of this research was to investigate the effect of various clay materials on the growth and change in mineral composition of soybean sprout. Further effect of sericite concentration on growth of soybean sprout was optimized. The experiments were carried by using three different viz., loess supernatant, tap water and sericite supernatant. From the obtained results it was found that a significant growth in soybean sprouts was observed while using sericite supernatant this growth was 14.71% and 50% more total growth than that of loess supernatant and tap water. In addition, using sericite supernatant the length of root of soybean sprouts was reached 17.30% and 36.50% longer than that of tap water and loess supernatant. The plausible reason for this growth using sericite supernatant may be due to the presence of various mineral($K^+$, $Ca^+$) in sericite. Further the mineral contents of sericite supernatant were 11.56% and 13.48% more than that for loess supernatant and tap water. Among the various sericite concentration used it was found that 100g/L sericite supernatant showed significant growth rate compared with other fractions. From the obtained results comparing with all materials 100g/L sericite concentration was economic for the cultivation of soybean sprout.