• Title/Summary/Keyword: tank bottom

Search Result 251, Processing Time 0.024 seconds

Seismic response analysis of an unanchored vertical vaulted-type tank

  • Zhang, Rulin;Cheng, Xudong;Guan, Youhai;Tarasenko, Alexander A.
    • Earthquakes and Structures
    • /
    • v.13 no.1
    • /
    • pp.67-77
    • /
    • 2017
  • Oil storage tanks are vital life-line structures, suffered significant damages during past earthquakes. In this study, a numerical model for an unanchored vertical vaulted-type tank was established by ANSYS software, including the tank-liquid coupling, nonlinear uplift and slip effect between the tank bottom and foundation. Four actual earthquakes recorded at different soil sites were selected as input to study the dynamic characteristics of the tank by nonlinear time-history dynamic analysis, including the elephant-foot buckling, the liquid sloshing, the uplift and slip at the bottom. The results demonstrate that, obvious elephant-foot deformation and buckling failure occurred near the bottom of the tank wall under the seismic input of Class-I and Class-IV sites. The local buckling failure appeared at the location close to the elephant-foot because the axial compressive stress exceeded the allowable critical stress. Under the seismic input of Class-IV site, significant nonlinear uplift and slip occurred at the tank bottom. Large amplitude vertical sloshing with a long period occurred on the free surface of the liquid under the seismic wave record at Class-III site. The seismic properties of the storage tank were affected by site class and should be considered in the seismic design of large tanks. Effective measures should be taken to reduce the seismic response of storage tanks, and ensure the safety of tanks.

Numerical Study on the Design Safety of $9\%$ Nickel Based Inner Tank Bottom Plate in Terms of Hydrostatic Pressure (유체정압을 고려한 $9\%$ 니켈강재 내부탱크 바닥판의 설계 안정성에 관한 수치적 연구)

  • Kim Chung Kyun;Kim Han Goo
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.35-41
    • /
    • 2004
  • This paper presents the stress and deformation characteristics of $9\%$ nickel based inner tank bottom plate in full containment LNG storage tank. When a . maximum hydrostatic pressure applies the bottom plate of inner tank, the maximum = f stress and displacement distributions of the bottom plate have been analyzed as ' functions of inclined angle of the bottom plate, and the thickness and length of the annular plate between the shell plate and bottom one. The calculated results indicate that the taper of the bottom plate is recommended by 100${\~}$200 : 1 for $140,000m^3$ storage capacity of the inner tank. The results recommend that the thickness of the annular plate is around 20mm and the length is greater than 3m for a maximum hydrostatic pressure of $140,000m^3$ tank capacity.

  • PDF

Measurement and Analysis on the Mixing Flows in a Tank with a Bottom Agitator using a Hybrid Volume Measurement Technique (하이브리드 볼륨측정법에 의한 하부교반 탱크내 혼합유동 측정 및 해석)

  • Doh, Deog Hee;Lee, Chang Jae;Baek, Tae Sil
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.3
    • /
    • pp.42-47
    • /
    • 2012
  • Experimental data for the flows in a mixing tank with a bottom agitator are useful for the validation of CFD commercial code. A hybrid volume PIV measurement technique was constructed to measure the flows inside of the mixing tank. The measurement system consists of three cameras. An agitator was installed at the bottom of the tank and it rotates clockwise and counterclockwise. Using the constructed measurement system, instantaneous vector fields were obtained. A phase averaging technique was adopted for the measured instantaneous three-dimensional velocity vector fields. Turbulent properties were evaluated from the instantaneous vector fields.

Longitudinal Modal Analysis of a LOX-filled Tank Using the Virtual Mass Method

  • Lee, SangGu;Sim, JiSoo;Shin, SangJoon;Kim, Youdan
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.4
    • /
    • pp.807-815
    • /
    • 2017
  • For liquid rocket engine(LRE)-based space launch vehicles, longitudinal instability, often referred to as the pogo phenomenon in the literature is predicted. In the building block of system-level task, accurate dynamic modeling of a fluid-filled tank is an essential. This paper attempts to apply the virtual mass method that accounts for the interaction of the vehicle structure and the enclosed liquid oxygen to LOX-filled tanks. The virtual mass method is applied in a modal analysis considering the hydroelastic effect of the launch vehicle tank. This method involves an analysis of the fluid in the tank in the form of mass matrix. To verify the accuracy of this method, the experimental modal data of a small hemispherical tank is used. Finally, the virtual mass method is applied to a 1/8-scale space shuttle external tank. In addition, the LOX tank bottom pressure in the external tank model is estimated. The LOX tank bottom pressure is the factor required for the coupling of the LOX tank with the propulsion system. The small hemispherical tank analysis provides relatively accurate results, and the 1/8-scale space shuttle external tank provides reasonable results. The LOX tank bottom pressure is also similar to that in the numerical results of a previous analysis.

Analysis of land-based circular aquaculture tank flow field using computational fluid dynamics (CFD) simulation (전산 유체 역학(CFD)을 이용한 원형 양식 사육 수조 내부 유동장 해석)

  • KWON, Inyeong;KIM, Taeho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.56 no.4
    • /
    • pp.395-406
    • /
    • 2020
  • The objectives of this study were to develop the optimal structures of recirculating aquaculture tank for improving the removal efficiency of solid materials and maintaining water quality conditions. Flow analysis was performed using the CFD (computational fluid dynamics) method to understand the hydrodynamic characteristics of the circular tank according to the angle of inclination in the tank bottom (0°, 1.5° and 3°), circulating water inflow method (underwater, horizontal nozzle, vertical nozzle and combination nozzle) and the number of inlets. As the angle in tank bottom increased, the vortex inside the tank decreased, resulting in a constant flow. In the case of the vertical nozzle type, the eddy flow in the tank was greatly improved. The vertical nozzle type showed excellent flow such as constant flow velocity distribution and uniform streamline. The combination nozzle type also showed an internal spiral flow, but the vortex reduction effect was less than the vertical nozzle type. As the number of inlets in the tank increased, problems such as speed reduction were compensated, resulting in uniform fluid flow.

Dynamic analysis of water storage tank with rigid block at bottom

  • Adhikary, Ranjan;Mandal, Kalyan Kumar
    • Ocean Systems Engineering
    • /
    • v.8 no.1
    • /
    • pp.57-77
    • /
    • 2018
  • The present paper deals with the finite element analysis of water tanks with rigid baffle. Fluid is discretized by two dimensional eight-node isoparametric elements and the governing equation is simulated by pressure based formulation to reduce the degrees of freedom in the domain. Both free vibration and force vibration analysis are carried out for different sizes and positions of block at tank bottom. The fundamental frequency depends on block height and it reduces with the increase of block height. The variation of hydrodynamic pressure on tank walls not only depends of the exciting frequency but also on the size and position of rigid block at tank bottom. The hydrodynamic pressure has higher value when the exciting frequency is equal and lower than the fundamental frequency of the water in the tank. Similarly, the hydrodynamic pressure increases with the increase of width of the block for all exciting frequencies when the block is at the centre of tank. The left and right walls of tank have experienced different hydrodynamic pressure when the block is placed at off-centre. However, the increase in hydrodynamic pressure on nearest tank wall becomes insignificant after a certain value of the distance between the wall and the rigid block.

Construction and Evaluation of Thermal Crack Stability about Bottom Slab of the #219 LNG Underground Tank in Incheon (인천 LNG 지하탱크 #219 Bottom Slab시공 및 온도균열 안정성 평가)

  • Son, Young-Jun;Ha, Jae-Dam;Um, Tai-Sun;Lee, Jong-Ryul;Park, Jong-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.689-692
    • /
    • 2006
  • The crack of concrete induced by the heat of hydration is a serious problem, particularly in massive concrete structures. In order to control the temperature crack of massive concrete, the selection of appropriate materials like low heat cement, mixture materials, etc. is essential. In tills study, mix proportion using low heat portland cement and lime stone powder was designed and the best mix proportion, B-1, was selected. When bottom slab of the #219 LNG tank in Incheon was constructed, concrete temperature was measured. And thermal stress was analyzed about bottom slab of the LNG tank. As results of the thermal analysis, crack index was 1.60 in bottom slab and satisfied with construction specifications(over 1.0).

  • PDF

Study on Corrosion Law of Large Crude Oil Storage Tank Floor and Risk-Based Inspection and Maintenance Technology

  • Luo, Fang-Wei;Ran, Ran;Wang, Lei
    • Corrosion Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.66-74
    • /
    • 2020
  • In this paper, the author's team has carried out a comparative experimental study on the corrosion characteristics of Q235 steel commonly used in large-scale storage tanks under the specific bottom water environment found with Russian and Daqing crude oil. It was found that there is a certain degree of uniform or local corrosion on the tank floor depending on the kind of bottom water. The bottom water corrosion of Daqing crude oil is a uniform corrosion caused by carbon dioxide. While the Russian crude oil bottom water corrosion is clearly local corrosion caused by co-corrosion of carbon dioxide and hydrogen sulfide, here the corrosion rate is obviously higher than that caused by Daqing crude oil. There are two modes of storage tank inspection and maintenance that have been currently adopted by Chinese refining and chemical enterprises: a regular inspection mode and a API581-2016 risk-based detection mode. These modes have been effectively combined to form an intelligent tank inspection and maintenance mode, software tools to support this intelligent inspection and maintenance management have been developed.

Analysis of Fluid Flows in a Stirred Tank Using Computational Fluid Dynamics (전산유체역학을 이용한 교반탱크 내 유체흐름 해석)

  • Kim, Mi Jin;Lee, Kyung Mi;Park, Kyun Young
    • Korean Chemical Engineering Research
    • /
    • v.48 no.3
    • /
    • pp.337-341
    • /
    • 2010
  • The flow patterns in a stirred tank, 1m in diameter and 1 m in height, were studied using CFX, a commercial computational fluid dynamics program, with the impeller rotation speed, the impeller blade angle and the tank-bottom shape varied and the baffles included or excluded. A vortex was observed in the center of the tank in the absence of the baffles, and the intensity of the vortex increased with increasing the rotation speed. The vortex was considerably reduced in the presence of the baffles. An increase in the blade angle increased the vertical flow and decreased the vortex intensity. The flow in the corners of the tank bottom turned smoother as the tank bottom was varied in shape from flat to round.

A Study on the Effective Free Surface of Fluid Cargo (유동화물의 유효자유표면에 관한 연구)

  • Hur, I.;Wang, J.S.
    • Journal of the Korean Institute of Navigation
    • /
    • v.11 no.2
    • /
    • pp.73-88
    • /
    • 1987
  • It is well known that the height of tank metacenter above the centroid of fluid in a tank is given by i/v where I is the inertia moment of free surface and v is the fluid volume. It is supposed in this formula that the inclination of ship is small and that the free surface of fluid do not touch the top and the bottom of tank. It the inclination of ship is large, the height of tank metacenter may be possibly greater than that given by i/v. The height of tank metacenter is smaller than i/v when the free surface of fluid touch the top or the bottom of tank. The reasonable method to calculate the height of tank metacenter is presented in this paper and prepared in FORTRAN program by FUNCTION EFFRES. The approximate formula was also developed and given by $g_m=(1+\frac{2}{1}tan^2\theta)[1-EXP\{-12(\frac{\alpha(1-\alpha)k}{tan\theta})^{1.25}\}]\frac{i}{v}$ where $g_m$ is the distance from the centroid of fluid to the tank metacenter, $\theta$ is inclined angle of ship, $\alpha$ is the ratio of filled volume to tank capacity and k is the ratio of the depth to the width of tank. The values calculated by the approximate formula given in this paper were compared with the exact values from the computer program and proved out to be sufficiently precise for practical use.

  • PDF