• Title/Summary/Keyword: tactile sensor

Search Result 145, Processing Time 0.019 seconds

Development of a Backpack-Based Wearable Proximity Detection System

  • Shin, Hyungsub;Chang, Seokhee;Yu, Namgyenong;Jeong, Chaeeun;Xi, Wen;Bae, Jihyun
    • Fashion & Textile Research Journal
    • /
    • v.24 no.5
    • /
    • pp.647-654
    • /
    • 2022
  • Wearable devices come in a variety of shapes and sizes in numerous fields in numerous fields and are available in various forms. They can be integrated into clothing, gloves, hats, glasses, and bags and used in healthcare, the medical field, and machine interfaces. These devices keep track individuals' biological and behavioral data to help with health communication and are often used for injury prevention. Those with hearing loss or impaired vision find it more difficult to recognize an approaching person or object; these sensing devices are particularly useful for such individuals, as they assist them with injury prevention by alerting them to the presence of people or objects in their immediate vicinity. Despite these obvious preventive benefits to developing Internet of Things based devices for the disabled, the development of these devices has been sluggish thus far. In particular, when compared with people without disabilities, people with hearing impairment have a much higher probability of averting danger when they are able to notice it in advance. However, research and development remain severely underfunded. In this study, we incorporated a wearable detection system, which uses an infrared proximity sensor, into a backpack. This system helps its users recognize when someone is approaching from behind through visual and tactile notification, even if they have difficulty hearing or seeing the objects in their surroundings. Furthermore, this backpack could help prevent accidents for all users, particularly those with visual or hearing impairments.

A Medical Palpation Guidance System for Minimally Invasive Surgery using Contact Pressure Distribution (접촉 압력 분포를 이용한 최소 침습 수술을 위한 의료 촉진 가이던스 시스템)

  • Kim, Hyoungkyun;Chung, Wan Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.266-273
    • /
    • 2017
  • In this research a medical palpation guidance system for minimally invasive surgery (MIS) is proposed. Palpation is a useful tool for identifying a size and location of a lump during a surgery. However, conventional manual palpation is only available in open surgery, so there has been several researches about palpation assistant or guidance system for MIS. The previously developed systems are based on a pressure based or stiffness based approach. These previous approaches have some limitations in increasing complexity of the systems and lack of geometric information about the lump which is more important information for the lump removal than the stiffness information. We propose a palpation guidance system using a novel approach using contact pressure distribution. Since our approach gives the geometry information of the lump as well as the existence information, the operator can easily notice the currently identified lump region and the optimal position for the next palpation. The experiment results show that our approach can offer the geometry information of the lump correctly.

A Study on Gel-free Probe for Detecting EEG (뇌파 탐지용 Gel-free probe 연구)

  • Yun, Dae-Jhoong;Eum, Nyeon-Sik;Jeong, Myung-Yung
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.156-166
    • /
    • 2012
  • Over the past 15 years productive BCI research programs have arisen. Current mainstream EEG electrode setups permit efficient recordings but most of electrodes has the disadventages of need for skin preparation and gel application to correctly record signals. The new gel-free probe was adapted for EEG recording and it can be fixed to the scalp with the micro needle without neuro-gel. It use standard EEG cap for wearing electrodes on scalp so it is compatible with standard EEG electrodes. A comparison between electrode characteristics is achieved by performing simultaneous recordings with the gel electrodes and gel-free probe placed in parallel scalp positions on the same anatomical regions. The quality of EEG recordings for all two types of experimental conditions is similar for gel-electrodes and gel-free probe. Subjects also reported not having special tactile sensations associated with wearing of gel-free probes. According to our results, it is expected that gel-free probe can be adapted to BCI, BMI(Brain Machine Interface), HMI(Human Machine Interface) because of its simple application and comfortable wearing process.

A Study on Development of Automatic Path Tracking Algorithm for LNG Aluminium Plate and Selection of Process Parameters by Using Artificial Intelligence (LNG 알루미늄 판재 가공용 자동 궤적 추적 알고리즘 개발 및 인공지능을 이용한 공정조건 선정에 관한 연구)

  • 문형순;권봉재;정문영;신상룡
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.8
    • /
    • pp.17-25
    • /
    • 1998
  • Aluminum alloys have low density, relatively high strength and yield strength, good plasticity, good machinability, and high corrosion and acid resistance. Therefore, they are suitable for large containers for the food, chemical and other industries. Large containers are often bodies of revolution consisting of shell courses, stiffening rings, heads and other elements joined by annular welds. Larger containers have longer welds and require greater leak-tightness and higher weld mechanical properties. The LNG tank consists of aluminum plates with various sizes, so its construction should by divided by several sections. Moreover, each section has its own sub-section consisted of several aluminum plates. To guarantee the quality of huge LNG tank, therefore, the precise control of plate dimension should by urgently needed in conjunction with the appropriate selection of process parameters such as cutting speed, depth of cut, rotational speed and so on. In this paper, a manufacturing system was developed to implement automatic circular tracking in height direction and automatic circular interpolation in depth of cut direction. Also, the neural network based on the backpropagation algorithm was used to predict the cutting quality and motor load related with the life time of the developed system. It was revealed that the manufacturing system and the neural network could be effectively applied to the bevelling process and to predict the quality of machined area and the motor load.

  • PDF

Muscle Stiffness and Elasticity Related to Physical Therapeutic Modalities (물리치료에 따른 근육의 경도와 탄성도 비교)

  • Kim, Sung-Hwan;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.319-328
    • /
    • 2007
  • The purpose of this study was to quantitatively assess treatment effect of physical therapy on experimentally-induced masseter muscle fatigue by two parameters of muscle stiffness and elasticity. Three physical therapeutic modalities inducing electroacupunture stimulation therapy(EAST), Microwave diathermy and low-level laser therapy(LLLT) were compared. 10 healthy volunteers with normal occlusion (mean age of $26.3{\pm}1.16$ years, M:F=1:1) were participated in this study. All subjects were asked to chew gum on the right side until they felt pain(more and VAS 5 (0 to 10)) and their masseter muscles were examined with a tactile sensor in order to evaluate changes of stiffness and elasticity according to gum chewing and three physical therapeutic modalities. Subjective discomfort or pain was self-estimated by VAS as well. Unilateral gum chewing increased stiffness and decreased elasticity only on the chewing side but VAS increased on the both sides(p<0.05). EAST or Microwave diathermy greatly decreased stiffness and VAS and increased elasticity(p<0.05) but LLLT did not exhibit significant difference. From the results of this study, it is concluded that both EAST and Microwave diathermy have favorable effect on stiffness and elasticity of muscles and pain relief while effect of LLLT is not reliable. In addition, experimental unilateral gum chewing compromises stiffness and elasticity of masseter muscles only the chewing side while subjective discomfort or pain can be felt on the both sides.