• Title/Summary/Keyword: system unavailability

Search Result 72, Processing Time 0.025 seconds

The application study of preventive maintenance during normal operation for APR1400 nuclear power plants considering risk

  • Jung-Wun Kim;YoungJu Lee;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.56 no.10
    • /
    • pp.4327-4334
    • /
    • 2024
  • Preventive Maintenance(PM) for safety component during power operation at nuclear power plants, On-Line Maintenance(OLM) refers to intentionally entering the Limited Condition of Operation(LCO) specified in the Technical Specification(TS) for safety-related systems and components in order to perform preventive maintenance within the Allowed Outage Time (AOT). This study assessed the feasibility of conducting OLM at the domestic APR1400 nuclear power plant. It focused on preventive maintenance duration and risk perspectives. A total of 78 FEGs were developed for 4450 facilities, considering system functions and preventive maintenance scope during output operation for eight safety-related systems. Additionally, maintenance items included in FEGs were selected, designated as targets for OLM, and their maintenance durations were evaluated and compared with AOT for each maintenance item. As a result, the Auxiliary Feedwater and Essential Chilled Water systems were identified as systems allowing OLM. Furthermore, utilizing the Risk Monitoring System (RIMS), the increased risk value due to the unavailability of target equipment during preventive maintenance was analyzed to determine whether it falls within the acceptable range. Regarding the temporary risk increase caused by OLM, it was observed that in all systems, it falls within Zone III according to NUMARC93-01 standards, allowing for normal equipment arrangement for OLM. However, according to the risk increase standards rate in domestic nuclear power plants, when maintaining the A-train in four systems including Component Cooling Water, they are all evaluated as 'Orange,' indicating that measures for risk mitigation are necessary for OLM to be feasible. When considering extending AOT up to 1.6 times the maintenance time, the risk increase falls within Zone III according to permissible change in risk standards, indicating that AOT extension might be feasible based solely on risk changes. To apply OLM within the permissible risk management scope in domestic nuclear power plants, regulatory policies need to allow voluntary LCO entry for preventive maintenance, necessitating clear determination by regulatory agencies using risk-informed policies. While OLM seems viable concerning maintenance duration and quantitative risk aspects, for inducing regulatory policy changes, comprehensive OLM guidelines are necessary, including risk management strategies.

An Availability Analysis Of Switching Control System with Hot Standby Fault Tolerant Architecture (Hot Standby 고장 감내 구조를 지원하는 교환 제어시스템의 가동률 분석)

  • Song, Gwang-Seok;Yeo, Hwan-Geun;Han, Chang-Ho;Mun, Tae-Su;Yu, Chung-Ryeol;Lee, Gwang-Bae;Kim, Hyeon-Uk;Yun, Chung-Hwa
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.6
    • /
    • pp.985-994
    • /
    • 1995
  • In this paper, we propose two hot standby architectures which not only provide high system availability but also lose little data on fault occurrence. In order to evaluate the performance of the proposed hot standby architectures, the warm standby architecture. In order to evaluate the performance of the propose d hot standby architectures, the warm standby architecture which is made from the hot standby architecture by eliminating its synchronization unit is considered. After system unavailability for each architecture is computed by using the corresponding Markov state diagram, the results are compared and evaluated. As the results, in most cases, hot standby architectures have higher availability than warm standby architecture. Also, hot standby architecture with external synchronization unit always maintains a little higher availability than hot standby architecture with internal synchronization unit. Active set time and personnel recovery rate for each architecture have little effect on system availability. However, in the case that data recovery time is too long, system availabilities of hot standby architectures and warm standby architecture degrade rapidly. In this case, the performance degradation of hot standby architectures is severe, and system availabilities of hot standby architectures eventually become lower than system availability of warm standby architecture.

  • PDF

A brief survey on awareness of pharmacovigilance among ayurveda physicians in Sri Lanka

  • Perera, Pathirage Kamal;Dahanayake, Jeevani;Karunagoda, Kaumadi
    • CELLMED
    • /
    • v.5 no.1
    • /
    • pp.3.1-3.3
    • /
    • 2015
  • Pharmacovigilance is the study of the safety of drugs under the practical conditions of clinical usage in large communities. Aim of this study was to assess the pharmacovigilance awareness among a focus group of Ayurveda physicians in Sri Lanka who participated for their postgraduate studies. A questionnaire which was suitable for assessing the basic knowledge, attitude and the practice of pharmacovigilance was designed and submitted among group of Ayurveda physicians (n = 30) who participated for postgraduate studies in Institute of Indigenous Medicine, University of Colombo, Sri Lanka. Among participants30% of the subjects knew the term pharmacovigilance, 20% were aware of the unavailability of the National Pharmacovigilance Program for Ayurveda and Traditional Medicine in Sri Lanka, 70% believe about Adverse Drug Reactions (ADRs) may be occurred from Ayurveda medicine, 60% indicated that Most labeled counterfeit drugs, inappropriate use and standardization problems as the most important causes of ADRs associated with Ayurvedicdrugs, 70% physicians accepted their ignorance about pharmacovigilance and admitted that there was a need for better training of this subject and 90% admitted that there should be a national pharmacovigilance programme for Ayurveda medicines in Sri Lanka. We strongly suggest that there is an urgent need for a regular training and the introduce ADRs reporting system among the Ayurveda physicians. Also systematic pharmacovigilance programme is essential to build up for reliable information on the safety and effective practice of Ayurveda medicine in Sri Lanka.

A Fair Radio Resource Allocation Algorithm for Uplink of FBMC Based CR Systems

  • Jamal, Hosseinali;Ghorashi, Seyed Ali;Sadough, Seyed Mohammad-Sajad
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.6
    • /
    • pp.1479-1495
    • /
    • 2012
  • Spectrum scarcity seems to be the most challenging issue to be solved in new wireless telecommunication services. It is shown that spectrum unavailability is mainly due to spectrum inefficient utilization and inappropriate physical layer execution rather than spectrum shortage. Daily increasing demand for new wireless services with higher data rate and QoS level makes the upgrade of the physical layer modulation techniques inevitable. Orthogonal Frequency Division Multiple Access (OFDMA) which utilizes multicarrier modulation to provide higher data rates with the capability of flexible resource allocation, although has widely been used in current wireless systems and standards, seems not to be the best candidate for cognitive radio systems. Filter Bank based Multi-Carrier (FBMC) is an evolutionary scheme with some advantages over the widely-used OFDM multicarrier technique. In this paper, we focus on the total throughput improvement of a cognitive radio network using FBMC modulation. Along with this modulation scheme, we propose a novel uplink radio resource allocation algorithm in which fairness issue is also considered. Moreover, the average throughput of the proposed FBMC based cognitive radio is compared to a conventional OFDM system in order to illustrate the efficiency of using FBMC in future cognitive radio systems. Simulation results show that in comparison with the state of the art two algorithms (namely, Shaat and Wang) our proposed algorithm achieves higher throughputs and a better fairness for cognitive radio applications.

Survey of the Antidote Stocking in the Emergency Medical Centers in Korea (국내 응급의료센터의 해독제 보유 현황)

  • You, Je-Sung;Kim, Eui-Chung;Lee, Hahn-Shick;Kim, Seung-Ho;Chung, Sung-Pil
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.5 no.2
    • /
    • pp.106-111
    • /
    • 2007
  • Purpose: Inadequate hospital stocking and unavailability of essential antidotes is a worldwide problem. The purpose of this study was to determine the adequacy of antidote stocks in Korean hospitals based on a modified version of US antidote stocking guidelines. Methods: Both written and telephone surveys to collect information on hospital demographics and antidote stocking were given to the emergency departments or hospital pharmacies of 117 hospitals with emergency medical centers. The twenty antidotes included in the survey were taken from year 2000 US antidote stocking guidelines, except for activated charcoal and black widow spider antivenin. Antidote stocks were compared by hospital size, geographic location, and type of emergency medical center. Results: Complete responses were received from all hospitals. A mean of $12.4{\pm}2.9$ antidotes were adequately stocked per hospital. All hospitals stocked atropine, $CaCl_2$ naloxone, and sodium bicarbonate. However, digoxin Fab fragment (16%), cyanide kits (15%), EDTA (10%), BAL (9%), and fomepizole (1%) were not uniformly stocked. Large and teaching hospitals were significantly more likely to stock greater numbers of antidotes. Conclusions: Korean hospitals as a group do not have adequate antidote stocks. Korean stocking guidelines and an antidote management system are recommended in order to correct these deficiencies.

  • PDF

An efficient session management scheme for low-latency communications in 5G systems

  • Kim, Jae-Hyun;Kim, Seog-Gyu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.2
    • /
    • pp.83-92
    • /
    • 2020
  • In this paper, we propose an efficient session management scheme for low-latency communications in 5G systems. The main idea of the proposed scheme is to prevent unnecessary reattempt signalling overhead when the session establishment for low-latency communications fails. Also, this method avoids network resource waste and battery drain of mobile devices. If a UE(User Equipment) fails to establish an Always-on PDU session for low-latency communications with the 5G systems because of network failure or resource unavailability, the proposed method prevents the UE's re-establishment of the Always-on PDU session by the specific information in the NAS(Non-Stratum) message from the 5G systems. Through simulation, we show that the proposed efficient session management scheme (ESMS) minimizes unnecessary signalling overhead and improves battery efficiency of mobile devices compared to existing legacy mechanism in 5G systems.

Optimization of Data Placement using Principal Component Analysis based Pareto-optimal method for Multi-Cloud Storage Environment

  • Latha, V.L. Padma;Reddy, N. Sudhakar;Babu, A. Suresh
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.12
    • /
    • pp.248-256
    • /
    • 2021
  • Now that we're in the big data era, data has taken on a new significance as the storage capacity has exploded from trillion bytes to petabytes at breakneck pace. As the use of cloud computing expands and becomes more commonly accepted, several businesses and institutions are opting to store their requests and data there. Cloud storage's concept of a nearly infinite storage resource pool makes data storage and access scalable and readily available. The majority of them, on the other hand, favour a single cloud because of the simplicity and inexpensive storage costs it offers in the near run. Cloud-based data storage, on the other hand, has concerns such as vendor lock-in, privacy leakage and unavailability. With geographically dispersed cloud storage providers, multicloud storage can alleviate these dangers. One of the key challenges in this storage system is to arrange user data in a cost-effective and high-availability manner. A multicloud storage architecture is given in this study. Next, a multi-objective optimization problem is defined to minimise total costs and maximise data availability at the same time, which can be solved using a technique based on the non-dominated sorting genetic algorithm II (NSGA-II) and obtain a set of non-dominated solutions known as the Pareto-optimal set.. When consumers can't pick from the Pareto-optimal set directly, a method based on Principal Component Analysis (PCA) is presented to find the best answer. To sum it all up, thorough tests based on a variety of real-world cloud storage scenarios have proven that the proposed method performs as expected.

Development of a ladder-shape melting temperature isothermal amplification (LMTIA) assay for detection of African swine fever virus (ASFV)

  • Wang, Yongzhen;Wang, Borui;Xu, Dandan;Zhang, Meng;Zhang, Xiaohua;Wang, Deguo
    • Journal of Veterinary Science
    • /
    • v.23 no.4
    • /
    • pp.51.1-51.10
    • /
    • 2022
  • Background: Due to the unavailability of an effective vaccine or antiviral drug against the African swine fever virus (ASFV), rapid diagnosis methods are needed to prevent highly contagious African swine fever. Objectives: The objective of this study was to establish the ladder-shape melting temperature isothermal amplification (LMTIA) assay for the detection of ASFV. Methods: LMTIA primers were designed with the p72 gene of ASFV as the target, and plasmid pUC57 was used to clone the gene. The LMTIA reaction system was optimized with the plasmid as the positive control, and the performance of the LMTIA assay was compared with that of the commercial real-time polymerase chain reaction (PCR) kit in terms of sensitivity and detection rate using 200 serum samples. Results: Our results showed that the LMTIA assay could detect the 104 dilution of DNA extracted from the positive reference serum sample, which was the same as that of the commercial real-time PCR kit. The coincidence rate between the two assays was 100%. Conclusions: The LMTIA assay had high sensitivity, good detection, and simple operation. Thus, it is suitable for facilitating preliminary and cost-effective surveillance for the prevention and control of ASFV.

A Study on Urban Inundation Prediction Using Urban Runoff Model and Flood Inundation Model (도시유출모형과 홍수범람모형을 연계한 내수침수 적용성 평가)

  • Tak, Yong Hun;Kim, Jae Dong;Kim, Young Do;Kang, Boosik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.395-406
    • /
    • 2016
  • Population and development are concentrated by urbanization. Consequently, the usage of underground area and the riverside area have been increased. By increasing impermeable layer, the urban basin drainage is depending on level of sewer. Flood damage is occurred by shortage of sewer capacity and poor interior drainage at river stage. Many of researches about flood stress the unavailability of connection at the river stage with the internal inundation organically. In this study, flood calculated considering rainfall and combined inland-river. Also, using urban runoff model analyze the overflow of sewer. By using results of SWMM model, using flood inundation analysis model analyzed internal drainage efficiency of drainage system. Applying SWMM model, which results to flood inundation analysis model, analyzes internal drainage efficiency of drainage system under localized heavy rain in a basin of the city. The results of SWMM model show the smoothness of internal drainage can be impossible to achieve because of the influence of the river level and sewer overflow appearing. The main manholes were selected as the manhole of a lot of overflow volume. Overflow reduction scenarios were selected for expansion of sewer conduit and instruction retention pond. Overflow volume reduces to 45% and 33~64% by retention pond instruction and sewer conduit expansion. In addition, the results of simulating of flood inundation analysis model show the flood occurrence by road runoff moving along the road slope. Flooded area reduces to 19.6%, 60.5% in sewer conduit expansion scenarios.

Evaluation of Egg Quality Traits in the Wholesale Market in Sri Lanka during the Storage Period

  • Jayasena, Dinesh D.;Cyril, Hewa W.;Jo, Cheorun
    • Journal of Animal Science and Technology
    • /
    • v.54 no.3
    • /
    • pp.209-217
    • /
    • 2012
  • The objective of this study was to assess the external and internal quality traits of eggs in wholesale egg market in Colombo, Sri Lanka and the effect of storage period in egg quality traits in the same market after receiving the eggs. First, a total of 482 fresh eggs were randomly collected from the above market and external egg quality traits were determined and recorded according to the definitions given in the Specification for Chicken Egg SLS 959:1992. After that, a total of 288 fresh eggs were randomly collected and various external and internal egg quality traits were measured and recorded according to the standard procedures over a storage period of 1, 3 and 5 d after receiving the fresh eggs to the wholesale market. Information about the shops was also collected using a pretested questionnaire. Using the recorded data, shape index, Haugh unit, albumen index and yolk index were calculated for each egg. Average weight, width, length and shape index of the eggs in the sample was 59.96 g, 4.33 cm, 5.78 cm and 75.03, respectively. Average shape index value was much closer to the standard value of 74. From the total sample 80.5% eggs had a normal and sound shape. However only 60.37% of the eggs are in the desirable quality range specified in SLS 959:1992, when the overall shell quality of the sample is considered based on shell cleanliness, defects and shape. The results of the current study indicated that eggs had significant (p<0.05) deterioration of all internal quality parameters tested with increasing storage time. However the effect was not significant (p>0.05) between the storage periods of 3 and 5 d after receiving eggs except for yolk color and yolk height. Desirable category of eggs had reduced and rejections had increased with the storage period. Main problems associated with the particular market were less space availability, higher percentages of dirty eggs, unavailability of proper packaging materials, no standard packaging system for eggs, and not implementing a standard grading system for eggs. Therefore the results of this study suggest that proper egg handling and storage conditions such as low temperature storage may be implemented to increase the proportion of desirable quality eggs in the above market.