• Title/Summary/Keyword: system separation method

Search Result 737, Processing Time 0.027 seconds

SPEECH SYNTHESIS USING LARGE SPEECH DATA-BASE

  • Lee, Kyu-Keon;Mochida, Takemi;Sakurai, Naohiro;Shirai, Katasuhiko
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.949-956
    • /
    • 1994
  • In this paper, we introduce a new speech synthesis method for Japanese and Korean arbitrary sentences using the natural speech data-base. Also, application of this method to a CAI system is discussed. In our synthesis method, a basic sentence and basic accent-phrases are selected from the data-base against a target sentence. Factors for those selections are phrase dependency structure (separation degree), number of morae, type of accent and phonemic labels. The target pitch pattern and phonemic parameter series are generated using those selected basic units. As the pitch pattern is generated using patterns which are directly extracted form real speech, it is expected to be more natural than any other pattern which is estimated by any model. Until now, we have examined this method on Japanese sentence speech and affirmed that the synthetic sound preserves human-like features fairly well. Now we extend this method to Korean sentence speech synthesis. Further more, we are trying to apply this synthesis unit to a CAI system.

  • PDF

On the Error Bound of the Approximate Solution of a Nonclassically Damped Linear System under Periodic Excitations

  • Hwang, Jai-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.4E
    • /
    • pp.45-52
    • /
    • 1996
  • One common procedure in the approximate solution of a nonclassically damped linear system is to neglect the off-diagonal elements of the normalized damping matrix. A tight error bound, which can be computed with relative ease, is given for this method of solution. The role that modal coupling plays in the control of error is clarified. If the normalized damping matrix is strongly diagonally dominant, it is shown that adequate frequency separation is not necessary to ensure small errors.

  • PDF

Simple Detection of Opines by Paper Electrophoresis for Hairy Roots Transformed with Agrobacterium rhizogenes Strains

  • Cho, Hyeon-Je;Ha, Hyo-Cheol;Lee, Jae-Sung;Widholm, Jack M.
    • Journal of Applied Biological Chemistry
    • /
    • v.44 no.2
    • /
    • pp.92-94
    • /
    • 2001
  • A simple protocol for the detection of opines, cucumopines and mikimopines using a general horizontal or vertical get electrophoresis system for protein or DNA separation in the laboratory are demonstrated. This electrophoresis method can also be applied to other opines as long as correct detection reagent and buffer system are used.

  • PDF

Performance Evaluations for the Partial-Admission Type Turbine System (부분흡입노즐방식의 터빈시스템에 대한 성능 평가)

  • 홍창욱;박승경;남궁혁준;김경호;김영수;우유철
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.11-14
    • /
    • 2001
  • 3-D compressible flow analysis was conducted by using mixing plane method for turbine system which is consisted of partial admission nozzle and rotor. Computational results are shown oblique shock wave in blade leading and trailing edge and also shown flow separation along suction surface of blade due to abrupt blade curvature. But computational results are well agree with 1-D calculation results and experimental data.

  • PDF

An Experimental Study on the Parallel plate Arrangement and Oil/water Separation Efficiency for Plate type Oily water Separator (분리판식 유수분리기의 평행판 배열과 유수분리 효율에 관한 실험적 연구)

  • Han Won-Hui;Kim Gwang-Su;Lee Jin-Yeol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.2
    • /
    • pp.52-60
    • /
    • 2001
  • The need to control the oil content in oily bilge water discharges to meet the increasing stringent seawater pollution standards has led to the development of gravity type separators. Among the several gravitational methods, a plate type oily water separator can be used as an assistant equipment for the oil filtering system to meet the present IMO standard of 15 ppm, because it is believed to be an efficient method dealing with a large amount of rich oil with high specific gravity. The purpose of this paper is to examine the efficiency of oil/water separation with the characteristics of separating plate arrangement. An experimental study was carried out to analyse an efficient treatment oil-water mixture with variation of operating parameters, including flow rates, inlet oil concentrations and the height between the plates. The experimental results show that the height between the plates has a significant effect on the separation efficiency. The best efficiency was acquired when the ration of the height between the plates the plates to distance(H/Ci) was 2 with lower inlet oil concentration and lower flow rate.

  • PDF

Separation of Pu and Nd from Uranium Matrix by Equilibrated Cation Exchanger for Burnup Measurement of Irradiated Nuclear Fuel (조사후핵연료의 연소도 측정을 위한 동적이온교환체에 의한 우라늄 매질로부터 Pu 및 Nd의 분리)

  • Joe, Kih-Soo;Kim, Jung-Suk;Jeon, Young-Shin;Han, Sun-Ho;Eom, Tae-Yoon
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.259-264
    • /
    • 1993
  • Ion chromatographic method has been applied for burnup measurement of irradiated nuclear fuel by dynamic system using 1-octanesulfonate as a cation exchanger and $\alpha$-hydroxyisobutyric acid as an eluant. A number of elution techniques were evaluated for the optimum separation of plutonium, uranium and neodymium. These elements were individually separated and collected by gradient elution between 0.05 M and 0.40 M of $\alpha$-hydroxyisobutyric acid in a single column, and finally determined by isotope dilution mass spectrometry. The burnup data from this method were compared with those from conventional anion exchange method. The results showed a good agreement within 3.5 % of difference between two methods.

  • PDF

Speciation of Chromium in Water Samples with Homogeneous Liquid-Liquid Extraction and Determination by Flame Atomic Absorption Spectrometry

  • Abkenar, Shiva Dehghan;Hosseini, Morteza;Dahaghin, Zohreh;Salavati-Niasari, Masoud;Jamali, Mohammad Reza
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2813-2818
    • /
    • 2010
  • A novel method was developed for the speciation of chromium in natural water samples based on homogeneous liquid-liquid extraction and determination by flame atomic absorption spectrometry (FAAS). In this method, Cr(III) reacts with a new Schiff's base ligand to form the hydrophobic complex, which is subsequently entrapped in the sediment phase, whereas Cr(VI) remained in aqueous phase. The Cr(VI) assay is based on its reduction to Cr(III) by the addition of sodium sulfite to the sample solution. Thus, separation of Cr(III) and Cr(VI) could be realized. Homogeneous liquid-liquid extraction based on the pH-independent phase-separation process was investigated using a ternary solvent system (water-tetrabutylammonium ion ($TBA^+$)-chloroform) for the preconcentration of chromium. The phase separation phenomenon occurred by an ion-pair formation of TBA and perchlorate ion. Then sedimented phase was separated using a $100\;{\mu}L$ micro-syringe and diluted to 1.0 mL with ethanol. The sample was introduced into the flame by conventional aspiration. After the optimization of complexation and extraction conditions such as pH = 9.5, [ligand] = $1.0{\times}10^{-4}\;M$, [$TBA^+$] = $2.0{\times}10^{-2}\;M$, [$CHCl_3$] = $100.0\;{\mu}L$ and [$ClO_4$] = $2.0{\times}10{-2}\;M$, a preconcentration factor (Va/Vs) of 100 was obtained for only 10 mL of the sample. The relative standard deviation was 2.8% (n = 10). The limit of detection was sufficiently low and lie at ppb level. The proposed method was applied for the extraction and determination of chromium in natural water samples with satisfactory results.

The Coexistence of OFDM-Based Systems Beyond 3G with Fixed Service Microwave Systems

  • Jo Han-Shin;Yoon Hyun-Goo;Lim Jae-Woo;Chung Woo-Ghee;Yook Jong-Gwan;Park Han-Kyu
    • Journal of Communications and Networks
    • /
    • v.8 no.2
    • /
    • pp.187-193
    • /
    • 2006
  • In this paper, we study the coexistence of orthogonal frequency division multiplexing (OFDM)-based systems beyond 3G (B3G) and point-to-point (P-P) fixed service (FS) microwave systems. The advanced general analytical model derived via a power spectral density (PSD) analysis proposed in this paper has two advantages in comparison with the conventional minimum coupling loss (MCL) method. First, the interfering signal power that appears in the band of a victim system can be easily assessed without a spectrum emission mask. Second, when transmit power is not allocated to some subcarriers overlapping the band of the victim system in order to mitigate B3G OFDM-based systems interference with other systems, the general analytical model can successfully assess the interference from the B3G systems into FS systems, whereas the MCL method incorporating the spectrum emission mask cannot be applied in the presence of the same interference condition. The proposed model can be derived in a closed form and is simply implemented with the help of simulation, and thus the solution can be obtained in significantly reduced time. Through application of the proposed model, coexistence results are analyzed in a co-channel and adjacent channel with respect to guard band and minimum separation distance.

Vortex Flow Analisys around the Floating Body with Vertical Plate (연속부착된 수직평판을 갖는 부유구조물 주위의 와유동 해석)

  • Kim, Ho;Lee, Gyoung-Woo;Cho, Dae-Hwan;Gim, Ok-Sok
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.161-168
    • /
    • 2007
  • In this paper, the floating body with double barriers is introduced with a study on the flow patterns and characteristics in around the floating body by using 2 frame p article tracking method. This paper introduce an analisys method to predict the characteristics of flow around the neighbording fields of Floating Body with double barriers in order to investigate a high performance model. Flow visualization has conducted in a circulating water channel by a high speed camera and etc. Flow phenomena according to velocity distribution and flow separation around the floating body with double barriers were obtained by two-dimensional PIV system.

  • PDF

Characteristics of the Electrochemical Ion Exchanger for the Treatment of Cations in Nuclear Wastewater (원자력 폐수의 양이온 처리를 위한 전기화학적 이온교환체의 특성)

  • Hwang, Young-Gi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.19 no.4
    • /
    • pp.176-184
    • /
    • 2016
  • Electrochemical ion exchange method is expected to be one of the most acceptable techniques for the separation of radioactive cations from nuclear wastewater. In this study a thin film of hexacyanoferrate on nickel surface was derivatized chemically in an aqueous potassium-ferricyanide solution. Electrochemical redox behavior of the nickel hexacyanoferrate(NiHCNFe) film electrode was investigated with the use of cyclic voltammetry potentiostated from -100 to 800 mV versus SCE. The electro-reduction characteristics of the NiHCNFe film were examined in the cobalt solutions. The NiHCNFe ion exchanger was more useful at lower concentration, lower temperature, and pH7 of the cobalt solution. The capacity loss of NiHCNFe was 0.018%/cycle that was less than the average loss of 2~3%/cycle of the convective organic exchanger. The 45~55% of the initial cobalt ions was electro-deposited on the NiHCNFe by using continuous recirculating reactor system. As a result, it was found that the electroactive NiHCNFe films showed better performance than the organic resins for the separation of cobalt ion from the aqueous solutions.