• 제목/요약/키워드: system rig test

검색결과 194건 처리시간 0.021초

PWM 제어에 의한 솔레노이드-유량제어방식 ABS의 제동압력 특성 (Braking Pressure Characteristics of Solenoid-Flow Control Type ABS by PWM Control)

  • 송창섭;양해정
    • 한국정밀공학회지
    • /
    • 제14권8호
    • /
    • pp.146-154
    • /
    • 1997
  • Solenoid-folw control type ABS is used with a 'dump and reapply' pressure control arrangement instead of using 2/2 (normal open/close) solenoid valves in convensional systems(sol. -sol. control type), a flow control valve is used which replaces the (no) inlet valve. The flow control valve controls fluid flow providing a nearly constant reapply rate( .theta. ) after the dump plase of ABS operation. In this study, to investigate a characteristics of brake pressure by PWM control, test rig was consisted of ABS hydraulic modulator, digital controller, pneumatic power supply and brake master cylinder. For comparison with experi- mental results, system modelling and computer simulation were performed. As a result, experiment results showed fairly agreement with the simulation. Also, it is shown that the pressure gradient (tan .theta. ) is affected by pressure, frequency, duty ratio and expressed with an exponential funtion.

  • PDF

EGR Cooler 내부 형상에 따른 Fouling이 냉각 성능에 미치는 영향 (The Effect of Cooling Efficiency on Fouling by EGR Cooler Internal Shape)

  • 남연우;오광철;이천환;이춘범;이원남
    • 한국자동차공학회논문집
    • /
    • 제19권1호
    • /
    • pp.101-108
    • /
    • 2011
  • Understanding the exhaust gas recirculation (EGR) cooler fouling in diesel engine is important factor in the durability characteristic of a EGR system. We develope a test rig and PM feeder using carbon black to examine the effect of fouling on EGR cooler devices those were consisted of flat and shell & tube type. The EGR cooler fouling process is a complex interaction involving heat exchanger shape, boundary condition, constitutes, chemistry and operating mode. As the soot deposited to EGR cooler, these formed a thin deposit layer that was less heat exchange than the fresh status of tube enclosing the exhaust gas, resulting in lower heat exchange effectiveness in both type coolers. But these deposits caused different results in pressure drop, it is increased in flat type, but decreased in Shell & tube type of EGR cooler. A cause was estimated from a change of the flow structure and a decrease of contact area as the EGR cooler fouling.

DME 커먼레일 차량의 윤활향상제에 관한 연구 (A Study on Lubricant additive of DME Common-rail Vehicle)

  • 박정권;김현철;정수진;전문수
    • 융복합기술연구소 논문집
    • /
    • 제3권1호
    • /
    • pp.15-18
    • /
    • 2013
  • The next generation alternative fuel of diesel, DME (Dimethyl Ether) discharges particulate matter hardly due to chemical structural as oxygen-fuel so it has the eco-friendly property. Despite these advantages, the DME has the technical difficulties to apply to the diesel engine because of a low calorific value, viscosity and compressibility effects. From this point of view, we performed experimental studies on improved reliability of DME common-rail vehicle and lubricity enhancement of DME fuel for empirical distribution of eco-friendly DME fuel. Also we analyzed solubility of lubrication enhancer according to a drop in temperature, try to secure reliability about core parts of DME vehicle by applying lubrication enhancer in the DME common-rail vehicle.

  • PDF

A Study on Integrated OWC System within Turbine Effects

  • Liu, Zhen;Hyun, Beom-Soo;Hong, Key-Yong;Lee, Young-Yeon;Jin, Ji-Yuan
    • 한국해양공학회지
    • /
    • 제24권2호
    • /
    • pp.1-9
    • /
    • 2010
  • Oscillating Water Column is one of the most widely used converting systems all over the world. The operating performance is influenced by the efficiencies of the two converting stages in the OWC chamber-turbine integrated system. In order to study the effects of the pressure drop induced by the air turbine, the experiments using the impulse turbine and the orifice device are carried out in the wave simulator test rig. The numerical simulation utilizing the orifice and porous media modules is calculated and validated by the corresponding experimental data. The numerical wave tank based on the two-phase VOF model embedded with the above modules is employed to investigate the wave elevation, pressure variation inside the chamber and the air flow velocity in the duct. The effects of the air turbine on the integrated system and interaction among the wave elevation, pressure and air flow velocities variations are investigated, which demonstrates that the present numerical model are more accurate to be employed.

1단 유성기어의 전달오차 특성에 대한 실험적 연구 - 토크 및 속도 변화의 영향 (Experimental Study on Transmission Errors of a Single-Stage Planetary Gear Train: Influence of Torque and Speed Variations)

  • 송진섭;이근호;박영준;남용윤
    • 한국생산제조학회지
    • /
    • 제24권3호
    • /
    • pp.320-326
    • /
    • 2015
  • Despite the wide industrial applications of planetary gear trains, the relationship between the design parameters (tooth profile, carrier mass, etc.) and performance (strength, vibration, noise, etc.) remains poorly understood. A significant amount of research has focused on transmission errors, which are measurable performance indicators directly related to the design parameters. Herein, an experimental test rig for a single-stage planetary gear set built using digital angular encoders and gap sensors is described. To study the static and dynamic characteristics of this planetary gear train, the transmission errors and sun gear orbit are analyzed from the data measured under various levels of torque and speed. The transmission errors of the gear train decrease 40% when the speed increases from 30 to 600 rpm with an output torque of 39.2 Nm, and increase 22% when the output torque increases from 19.6 to 39.2 Nm with an input speed of 30 rpm.

파워트레인 부품의 피로수명에 미치는 열처리의 영향 (Effect of Heat Treatment on Fatigue Life of the Power Train Part)

  • 허만대;심태양;이광오;유금빈;강성수
    • 열처리공학회지
    • /
    • 제22권4호
    • /
    • pp.203-209
    • /
    • 2009
  • Dual mass flywheel is the newly developed flywheel system which reduces the noise and vibration and make a better and comfortable ride of cars by adding inertia mass and damping device. However, verification of performance for this system should be carried out since this system is under developing status in our country. Especially, the durability for each part of this system should be guaranteed. Durable properties of driver plate which is the key component of dual mass flywheel were first investigated both in the raw (SCM435 in JIS) and heat-treated material. In addition, fatigue life analysis of driver plate was preformed in the real condition and the results were verified by comparison with the results of rig test.

Implementation of a new empirical model of steam condensation for the passive containment cooling system into MARS-KS code: Application to containment transient analysis

  • Lee, Yeon-Gun;Lim, Sang Gyu
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3196-3206
    • /
    • 2021
  • For the Korean design of the PCCS (passive containment cooling system) in an innovative PWR, the overall thermal resistance around a condenser tube is dominated by the heat transfer coefficient of steam condensation on the exterior surface. It has been reported, however, that the calculated heat transfer coefficients by thermal-hydraulic system codes were much lower than measured data in separate effect tests. In this study, a new empirical model of steam condensation in the presence of a noncondensable gas was implemented into the MARS-KS 1.4 code to replace the conventional Colburn-Hougen model. The selected correlation had been developed from condensation test data obtained at the JERICHO (JNU Experimental Rig for Investigation of Condensation Heat transfer On tube) facility, and considered the effect of the Grashof number for naturally circulating gas mixture and the curvature of the condenser tube. The modified MARS-KS code was applied to simulate the transient response of the containment equipped with the PCCS to the large-break loss-of-coolant accident. The heat removal performances of the PCCS and corresponding evolution of the containment pressure were compared to those calculated via the original model. Various thermal-hydraulic parameters associated with the natural circulation operation through the heat transport circuit were also investigated.

흡기포트 분사식 LPG 엔진의 연료량 제어 및 연소 특성에 관한 연구 (A Study on the Combustion Characteristics and the Control on the Fuel Flow Rate of LPG Intake Port Injection Engine)

  • 김우석;이종화;정창현
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.31-39
    • /
    • 2000
  • In this paper, characteristics of a port injection type LPG fuel system were investigated to adopt the system to a spark ignition engine through rig test. Engine combustion characteristics for limited conditions and the precise control method of LPG fuel supply were also studied. As a basic experiment, the effects and the relationships of parameters such as orifice area, fuel delivery pressure, fuel temperature and flow coefficient were established. From this, one dimensional compressible flow equation can be applied to control gaseous fuel flow rate by setting pressure difference between vaporizer and manifold to a certain range, for example about 1.2 bar in a naturally aspirated engine. The combustion analysis results of LPG engine were also compared with those of gasoline engine according to spark timing and load change. At part load and stoichiometric condition, the MBT spark timing of LPG fueled engine is retarded by 2$^{\circ}$ - 4$^{\circ}$CA compared to that of gasoline engine. On the contrary, the spark timing of LPG fueled engine can be advanced by 5$^{\circ}$- 10$^{\circ}$ CA at WOT, which results from higher Octane Number and burned fraction of LPG fuel compared to gasoline.

  • PDF

지면효과익의 공기역학특성을 위한 모사실험장치 개발에 관한 연구 (Simulator Development for the Aerodynamic Characteristics of a Wing in Ground)

  • 김태호;김희동;이명호;손명환;촌수남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1724-1729
    • /
    • 2003
  • A new ground transportation system is often simulated by the wing in ground effect(WIG). Recently, several kinds of experimental and computational studies are being carried out to investigate the WIG aerodynamic characteristics which are of practical importance to develop the new ground transportation vehicle system. These works are mainly based on conventional wind tunnel tests, but many problems associated with the WIG aerodynamic characteristics can not be satisfactorily resolved. In order to develop the new ground transportation vehicle system the WIG should be further investigated. To do this, it is necessary to develop a s imulator appropriate to the WIG aerodynamics. The objective of the present study is to clarify the aerodynamic characteristics of the WIG and to develop a new experimental test rig for the investigation of the WIG aerodynamics. Some preliminary experiments are performed to investigate the usefulness of the WIG simulator.

  • PDF

냉매 충전량에 따른 CO2용 수냉식 열펌프의 성능 특성에 관한 연구 (Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Variation of Refrigerant Charge Amount)

  • 손창효;유태근;장승일;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.558-566
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of refrigerant charge amount was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2400 mm length. The experimental results summarize as the followings : As the refrigerant charge ratio of $CO_2$ heat pump system increases, the discharge pressure and compressor ratio increases, but mass flow rate of refrigerant decreases. Also the compressor work increases with the increase of refrigerant charge ratio. However, the heating and cooling capacity of $CO_2$ heat pump decreases as the refrigerant charge ratio increases. The maximum heating COP of $CO_2$ heat pump system presented at 0.25 refrigerant charge ratio. It is possible to confirm the optimum charge ratio of $CO_2$ heat pump system by the viewpoint of heating COP.