• 제목/요약/키워드: system operation

검색결과 20,265건 처리시간 0.041초

수동운전방식에서의 PSD 출입문 신호반응 시간 개선 방안 연구 (PSD Door Response Time Improving Method in Train Manual Operation Mode)

  • 이무호;김찬겸;이석종;이수영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.559-571
    • /
    • 2008
  • Platform Screen Door(PSD) has been installed and operated at seoul subway line $1\sim4$ in the manual train operation mode(ATS/ATC) by SeoulMetro since 2005. SeoulMetro uses the wireless (RF) communication system and the train door detection system for the link between the train and PSD doors opening/closing motion in the manual train operation mode. For the convenience and safety of passengers, the train doors and the PSD doors opening/closing shall be synchronized as much as possible. In ATO(Automatic Train Operation) mode which provides the interface between train control system and PSD system, ATO signaling system makes the train doors and PSD doors open/close command signals systematically, so PSD doors can be opened/closed almost simultaneously with the train doors. But, in the manual train control(ATS/ATC) mode, PSD system needs to detect the train doors open/close operation and make PSD open/close command signals to actuate PSD doors. These PSD open/close commanding process cause time delay of PSD doors opening/closing motion in response to the train doors opening/closing motion. Sometimes the response delay time can be over 1 second, which is not proper to operate PSD, and need to be reduced This paper presents the reduction method of the PSD response delay time to improve the convenience and safety of passengers.

  • PDF

빙축열시스템의 실질적인 최대 축열 가능량 예측 (Prediction of practically chargeable cold energy in an ice storage system)

  • 이대영;강병하;김민수
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF

KSTAR 저온 및 구조 계측 시스템 운전 결과 (Operation result of the Cryogenic and Mechanical Measurement System for KSTAR)

  • 김영옥;추용;요네가와;방은남;이태구;백설희;홍재식;이상일;박갑래;오영국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.26-30
    • /
    • 2009
  • Korea Superconducting Tokamak Advanced Research(KSTAR) device is composed of 30 superconducting magnets, magnet structure, vacuum vessel, cryostat, current feeder system, and etc. KSTAR device is operated in the cryogenic temperature and high magnetic field. We install about 800 sensors - temperature sensors, stain gages, displacement gages, hall sensors - to monitor the thermal, mechanical, electrical status of KSTAR during operation. As a tremendous numbers of sensors should be installed for monitoring the KSTAR device, the method of effective installation was developed. The sensor test was successfully carried out to check its reliability and its reproduction in the cryogenic temperature. The sensor signal is processed by PXI-based DAQ system and communicated with central control system via machine network and is shown by Operator Interface(OPI) display in the main control room. In order to safely operate the device, any violations of mechanical & superconductive characteristic of the device components were informed to its operation system & operator. If the monitored values exceed the pre-set values, the protective action should be taken against the possible damage. In this paper, the system composition, operation criteria, operation result were presented.

직기 자동운전 감시 시스템 구성에 관한 연구 (A design of a automatic loom operation monitoring system)

  • 고명삼;이재곤;이상욱;성광제;손영대;유견아
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.153-157
    • /
    • 1986
  • This paper describes the design of a monitoring system of automatic loom operation, which can provide valuable data for production and management by monitoring the operation of upto 512 looms.

  • PDF

버스노선 운영체계의 효율성 평가 (Evaluating Efficiency of the Bus Route Operation System)

  • 김경식;정병두;김기혁
    • 대한교통학회지
    • /
    • 제31권4호
    • /
    • pp.67-75
    • /
    • 2013
  • 본 연구는 개별노선제와 공동배차제로 구분되는 버스노선 운영체계의 효율성을 분석하였다. 최근 시내버스 서비스 개선을 위해 버스노선 운영체계의 개편이 자주 검토되지만 실제 정책검토의 기초자료가 부족하고 이에 대한 연구결과 또한 상대적으로 부족한 실정이다. 이에 따라 본 연구에서는 두 가지 운영체계를 복합운영중인 울산시의 2009년 현재 101개 버스 노선을 대상으로 자료포락분석기법을 적용하여 버스노선별 효율성을 분석하였다. 분석결과 공동배차제는 규모면에서는 상대적으로 안정적이었으나, 효율성 측면에서는 개별노선제가 더 효율적인 것으로 나타났다. 특히 비효율의 원인은 공동배차제의 경우는 순수 기술적 요인, 개별노선제는 규모의 효율성에 있는 것으로 제시되어, 공동배차제의 책임성 부재로 인한 마케팅 및 노선관리의 등한시 현상과, 개별노선제의 노선운영 책임성 부여에 따른 현재 상태에서의 최적 노선운영을 확인할 수 있었다. 또한 개별노선제 운영노선이라도 순수 기술적 요인에 의한 비효율이 발생하는 것으로 분석되어 노선운영 체계개편 시에는 순수 기술적 효율성 제고방안 마련이 반드시 수반되어야 할 것이다.

A Study on Optimal Operation Strategy for Mild Hybrid Electric Vehicle Based on Hybrid Energy Storage System

  • Bae, SunHo;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.631-636
    • /
    • 2018
  • This paper proposed an optimal operation strategy for a hybrid energy storage system (HESS) with a lithium-ion battery and lead-acid battery for mild hybrid electric vehicles (mild HEVs). The proposed mild HEV system is targeted to mount the electric motor and the battery to a conventional internal combustion engine vehicle. Because the proposed mild HEV includes the motor and energy storage device of small capacity, the system focuses on low system cost and small size. To overcome these limitations, it is necessary to use a lead acid battery which is used for a vehicle. Thus, it is possible to use more energy using HESS with a lithium battery and a lead storage battery. The HESS, which combines the lithium-ion battery and the secondary battery in parallel, can achieve better performance by using the two types of energy storage systems with different characteristics. However, the system requires an operation strategy because accurate and selective control of the batteries for each situation is necessary. In this paper, an optimal operation strategy is proposed considering characteristics of each energy storage system, state-of-charge (SOC), bidirectional converters, the desired output power, and driving conditions in the mild HEV system. The performance of the proposed system is evaluated through several case studies with respect to energy capacity, SOC, battery characteristic, and system efficiency.

신규 도입차량 유지관리 기술과 품질보증 대책에 대한 고찰 (A Study on the New Rolling Stock Vehicle Maintenance Technology and Discussion on Quality Assurance Measures)

  • 최석중;김문홍;김봉래
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.27-37
    • /
    • 2011
  • Currently, in the course of introducing rolling stocks, RAMS standard and management by system engineering method apply to rolling stock system. Technical elements and results applied in system introduction phase are just used in acquisition stage, and these are not applied to the standard in railway site. Therefore, it is difficult to apply to standardized technology and quality assurance measure. Due to the establishment of the EU, railway operation system is internationalized and the international railway standards are being discussed in various ways. In addition, standardization is expanded from manufacture to operation and maintenance. It is to provide consistent standard in quality, cost calculation of maintenance technology, maintenance technology and quality assurance in case of international railway safety incidents. Therefore, this study is to find technology, quality and cost management model to be used for choosing railway-operation guidance by considering how technologies & quality have changed in system life cycle, compared with estimated standards, based on the technologies & quality-related result in the process of getting new rolling stocks and management guidance for operation & maintenance process.

  • PDF

안전도 향상을 위한 UPFC 운전 전략 (UPFC Operation Strategy for Enhancement of System Security)

  • 이동우;안선주;문승일;윤종수;장병훈;김수열;문승필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.177-178
    • /
    • 2006
  • The enhancement of system security is one of the most important objectives of UPFC operation. To describe the system security, the index related to line flows and bus voltages are used. For the enhancement of security, the operation point of UPFC is set to minimize the index. This paper proposes the minimization algorithm using the Marquardt method. Moreover, the coefficients minimizing iteration number will be derived. For verification of the proposed operation scheme, numerical simulations have been performed on power system in Kwanju area, Korea with a UPFC.

  • PDF

전기자동차용 80[kW] IPMSM 구동 시스템 개발 (Development of an 80[kW] IPMSM Drive System for an Electric Vehicle)

  • 김상훈;박내춘
    • 산업기술연구
    • /
    • 제33권A호
    • /
    • pp.61-66
    • /
    • 2013
  • This paper is about the development of 80[kW] IPMSM(Interior Permanent Magnet Synchronous Motor) drive system for an electric vehicle. MTPA(Maximum Torque per Ampere) operation and flux-weakening operation for the optimal torque control of the IPMSM are presented. In this system, the torque control of the IPMSM is achieved by using the look-up table, which gives d- and q-aixs current references for the given torque command in the MTPA operation and flux-weakening operation regions. This look-up table is made by current injection tests, and from which the motor parameters are also estimated. The proposed system is verified by the experiment on the electric vehicle drive system, which consists of an 80[kW] IPMSM and an IGBT inverter.

  • PDF

생활폐기물 관로이송용 터보블로어 운전 및 설계 최적화 연구 (Optimal design and operation of a turbo blower used for refuse collection system)

  • 장춘만
    • 한국유체기계학회 논문집
    • /
    • 제13권5호
    • /
    • pp.58-63
    • /
    • 2010
  • Optimal operation of turbo blowers connected in serial is analyzed by experimental measurements and numerical simulation with three-dimensional Navier-Stokes equations. The turbo blower system considered in the present study is widely used for the refuse collection system. Design optimization of the turbo blower using some design variables is also studied to enhance the performance of the blower. Throughout numerical simulation, it is found that the input energy reduction by optimal operation of the turbo blowers with the proper changes of the rotor's rotating frequency can be reduced a input energy for operating the blower system compared to the conventional on-off operation method theoretically. It is also found that the optimal design method is effective to enhance the performance of the turbo blower.