• Title/Summary/Keyword: system composition module

Search Result 63, Processing Time 0.03 seconds

A Study on properties of Lower Electrode thin films solar cell for Mo thin film (박막태양전지 하부전극용 Mo 박막특성 연구)

  • Yang, Hyeon-Hun;Kim, Young-Jun;Jeong, Woon-Jo;Park, Gye-Choon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.321-322
    • /
    • 2007
  • In order to increase the cost effectiveness of solar cells, module production should be treated more comprehensively. Back contact cells offer distinct advantage in the interconnection of cells to modules. Thereby Mo thin film were prepared in order to clarify optimum conditions for growth of the thin film depending upon process, and then by changing a number of deposition conditions and substrate temperature conditions variously, structural and electrical characteristics were measured. For the manufacture of the Mo were vapor-deposited in the named order. Among them, Mo were vapor-deposited by using the sputtering method in consideration of their adhesive force to the substrate, and the DC power was controlled so that the composition of Mo, while the surface temperature having an effect on the quality of the thin film was changed from R.T$[^{\circ}C]$ to $200[^{\circ}C]$ at intervals of $50[^{\circ}C]$. Micro-structural studies were carried out by XRD (D/MAX-1200, Rigaku Co.) and SEM (JSM-5400, Jeol Co.). Electrical properties were measured by CMT-SR3000 Measurement System.

  • PDF

The influence of the water ingression and melt eruption model on the MELCOR code prediction of molten corium-concrete interaction in the APR-1400 reactor cavity

  • Amidu, Muritala A.;Addad, Yacine
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1508-1515
    • /
    • 2022
  • In the present study, the cavity module of the MELCOR code is used for the simulation of molten corium concrete interaction (MCCI) during the late phase of postulated large break loss of coolant (LB-LOCA) accident in the APR1400 reactor design. Using the molten corium composition data from previous MELCOR Simulation of APR1400 under LB-LOCA accident, the ex-vessel phases of the accident sequences with long-term MCCI are recalculated with stand-alone cavity package of the MELCOR code to investigate the impact of water ingression and melt eruption models which were hitherto absent in MELCOR code. Significant changes in the MCCI behaviors in terms of the heat transfer rates, amount of gases released, and maximum cavity ablation depths are observed and reported in this study. Most especially, the incorporation of these models in the new release of MELCOR code has led to the reduction of the maximum ablation depth in radial and axial directions by ~38% and ~32%, respectively. These impacts are substantial enough to change the conclusions earlier reached by researchers who had used the older versions of the MELCOR code for their studies. and it could also impact the estimated cost of the severe accident mitigation system in the APR1400 reactor.

A Study on the Stabilized System Operation Considering the Reflection Characteristic of an Active-Phased Array Antenna (능동 위상 배열 안테나의 반사 특성을 고려한 안정적 시스템 운용에 관한 연구)

  • Kim, Young-Wan;Chae, Hee-Duck;Lee, Dong-Kook;Jeong, Myung-Deok;Park, Jong-Kuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • In this paper, a stabilizd system operation through a composition of a protective circuit and an improvement of active reflection coefficient(ARC) is studied. Unlike the passive-phased array antenna, the APPA is a combined form of radiating element and transmitter-reciever module. Therefore, a definition of new ARC that differentiates itself from typical passive-phased array antenna must apply. The ARC is a reflection coefficient considering a superposition of a coupling from nearby radiating elements and self reflection. It is an important parameter that predicts and analyzes charateristics of a APPR system. A high level ARC is a direct source inducing a performance degradation of a system. In this paper, as a method for a stabilized operation of APAR, one method for improving a performance and another for degradation prevention are analyzed. An effectiveness of two methods was validated using experiment results of real-fabricated active-phased array antenna.

A study of performance improvement of a thermoelectric generation system for the coastal fishing boats (연안어선용 열전발전 장치의 성능개선을 위한 연구)

  • LEE, Donggil;KIM, Hyunyoung;BAE, Sungyoun;KIM, Jiyeon;DO, Yonghyun;YANG, Yongsu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.3
    • /
    • pp.246-254
    • /
    • 2018
  • In this study, we developed a thermoelectric generation system for coastal fishing boats that allows for a high-density arrangement of thermoelectric modules, verified the improvement in performance by conducting comparative analysis between field test results and results from previous studies. The developed thermoelectric generation system was installed in a 3-ton gill-netter to analyze the engine revolutions per minute and energy production per day for each fishing process over a period of 20 days. From the experimental results, the maximum electric energy generated was 207.1 Wh, the minimum was 53.93 Wh and the average electric energy was 129.98 Wh. In accordance with the increasing of the engine r.p.m., the maximum electric production was 183 W at 1,500 r.p.m. It was approximately 80.5% of designed capacity, 227.2 W. Considering the result in the earlier research was 50.7% of designed capacity, 115.8 W. It was improved by 30% compared to the earlier one. The fishing operation was classified as departure, fishing and arrival. From the result on production analysis of electric energy, the composition of energy was 63% in fishing, 19.5% in departure and 17.5% in arrival. The electric energy production per unit hour was 42.8% in arrival, 32.9% in departure and 24.3% in fishing.

Flow-Accelerated Corrosion Analysis for Heat Recovery Steam Generator in District Heating System (지역난방 배열 회수 보일러의 유동 가속 부식 원인 고찰)

  • Hong, Minki;Chae, Hobyung;Kim, Youngsu;Song, Min Ji;Cho, Jeongmin;Kim, Woo Cheol;Ha, Tae Baek;Lee, Soo Yeol
    • Korean Journal of Materials Research
    • /
    • v.29 no.1
    • /
    • pp.11-15
    • /
    • 2019
  • Severe wall thinning is found on the tube of a low-pressure evaporator(LPEVA) module that is used for a heat recovery steam generator(HRSG) of a district heating system. Since wall thinning can lead to sudden failure or accidents that lead to shutdown of the operation, it is very important to investigate the main mechanism of the wall thinning. In this study, corrosion analysis associated with a typical flow-accelerated corrosion(FAC) is performed using the corroded tube connected to an upper header of the LPEVA. To investigate factors triggering the FAC, the morphology, composition, and phase of the corroded product of the tube are examined using optical microscopy, scanning electron microscopy combined with energy dispersive spectroscopy, and x-ray diffraction. The results show that the thinnest part of the tube is in the region where gas directly contacts, revealing the typical orange peel type of morphology frequently found in the FAC. The discovery of oxide scales containing phosphate indicates that phosphate corrosion is the main mechanism that weakens the stability of the protective magnetite film and the FAC accelerates the corrosion by generating the orange peel type of morphology.

Drupal-based Map Application Generator(MapAppGen): an Application Generation Example for Famous Restaurants (Drupal 기반 맵 응용 생성기 (MapAppGen) : 맛집탐방 응용 생성 사례)

  • Eum, Doo-Hun
    • The KIPS Transactions:PartD
    • /
    • v.19D no.3
    • /
    • pp.229-236
    • /
    • 2012
  • The demand for map applications in both Web and mobile environments has been rapidly increased with the population of Web and smart phone usage. Web-based map applications are mostly developed on such environments as ArcGIS and MapServer and mobile map applications are developed on such API levels as Google Maps and Yahoo Maps. But many parts of map applications are still constructed by coding because these environments don't support high level of automation. Our MapAppGen that we have designed and implemented enhances the Web-based map application productivity by generating the map related modules that can be applied to the Drupal that is one of popular content management systems(CMS's). Comparing the applications that are constructed by the Drupal-supported GMap or NodeMap, the applications that are constructed by MapAppGen provide information on not only the interested geographical feature but also its related geographical features. MapAppGen uses Google Maps API and Drupal is a module-based system that supports the creation, composition and management of contents. We are now working on automatic generation of mobile map applications with MapAppGen.

Facility Management Techniques Using AHP Model (의사결정모델을 이용한 시설물관리시스템)

  • Kang, In-Joon;Choi, Hyun;Lee, Jun-Seok
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.2 s.20
    • /
    • pp.19-27
    • /
    • 2002
  • The goal of this research is to develop the method of facility management which is used to manage the facility efficiently by using existing analyses of a system and a operation, and establish the method of a facility administration by applying AHP(Analytic Hierarchy Process) model. Because the standard of a accuracy in spacial analysis and calculation is a unclear, the exact analysis of a geographic data for a decision-making needs statistical analysis and administrator-centered type of system didn't satisfy the desire of users. There must be the existing general statistics module, integrated internet GIS and the composition of interface in order to structure a spacial statistics analysis methods that satisfy the matters desired in internet GIS into the spacial analysis function. This paper presents the need of internet GIS and AHP Model in supporting and managing function of all facilities in campus and introduce the possibility of applying.

  • PDF

u-Mart Network using RFID/USN based Movement-Reader Device for Effective Shopping of Customer (고객의 효율적인 쇼핑을 위한 RFID/USN 기반 이동형리더기를 이용한 u-마트 네트워크)

  • Diao, Jianhua;Yang, Jin-Ho;Ahn, Byeong-Tae;Kang, Hyun-Syug
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.5
    • /
    • pp.104-112
    • /
    • 2008
  • RFID/USN is considered important basic infra of ubiquitous community and tried practical adaption through various research. Specially, there is during researcher progresses for stock and state management of logistics to let you get at u-mart systems. It discern thing from warehouse to deliver as adhere RFID tag of palette in keeping unit of article and construct form of thing to analyze information of environment status using sence module based on function of wireless communication. in the paper, propose composition of customer satisfaction system using RFID chip in u-Mart status management system based on RFID/USN and according to analysis specific information of commodity, propose movement reader device to offer real-time information from customer. And it presents the improvement program for the provision of product information which is appropriate uses the RFID chip and the provision of control information in the customer who is a core of consuming.

A study on the electronic EGR valve control method (전자식 EGR밸브 제어기법에 관한 연구)

  • Choi, Sang-Yun;Lee, Sang-Hun;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2594-2602
    • /
    • 2014
  • As environmental awareness increases, regulations on exhaust gas of automobile, which is a cause of air pollution, have been strengthened. In order to meet emission regulation, automobile companies and engine manufacturers have actively developed the related technologies. Because the emission control has become severe, the systems using electronic motor or solenoid valve for high precise control are needed. For this reason, it is required not only the optimization of composition of components for improving performance and efficiency of the system but also the development of optimal design technology of electronic control system by securing the designing and manufacturing technology of the components. In this paper, it is proposed the position characteristics for electronic EGR valve module through the applied control logic and experiment results.

The Characteristics of Flexibility applied to Unit Plan of Housing by Residents Participation - focusing on European Multi-story Housing applying Residents Participation - (거주자 참여형 공동주거의 평면계획에 적용된 가변성의 특성 - 유럽의 거주자 참여형 다층 공동주거를 중심으로 -)

  • Kim, Hyun-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.113-123
    • /
    • 2018
  • First of all, the multi-story Housing applying resident's participation in europe was classified by the menu selection method, the two-step supply method and the cooperative method. And then I analyzed flexible unit plan of cases for deriving the planning methode and the characteristics of flexibility. First, I analyzed the area and form of the unit plan, structure and Installation, fixed and variable elements to derive the planning method. The area of units are distributed from a minimum of $35m^2$ to a maximum of $150m^2$, and many of the unit planes have a narrow front and a deep depth. The structure is a long-span wall-structure or a skeleton structure, and is designed without any columns and bearing walls in the interior space for flexibility in spatial composition. The vertical shafts are located in the center of the unit in a box-form or in the corner at the unit dividing wall for free placement of interior wall. Fixed elements are framework and facility systems. Most of the future residents in the two-steps supply method and the cooperative method were able to freely design the internal space within the zoning concept proposed by the architect and change the location of the facade element within module system proposed by the architect. Second, the characteristics of the flexibility applied to the unit plan were divided in integrated flexibility, functional flexibility, construction flexibility, and supply flexibility. The integrated flexibility enables residents to give the variable space combination based on the complex structure of the inner space for providing various living experiences. Regarding functional flexibility, the three-dimensional spatial structure with neutral space has multi-functionality according to the needs of residents and easily accepts mixing of hybrid programs such as work and residence. Constructive flexibility allows residents to create identity by freely planning interior space and changing the size or location of facade components in a determined system of architects. Finally, various types of size and space composition are proposed and realized in the whole building applying menu selection method, so that flexibility in the offer can accommodate and integrate various types of living.