• Title/Summary/Keyword: system calibration

Search Result 2,065, Processing Time 0.028 seconds

Development of the Calibration Method for the Boost Pressure and EGR Rate of a WGT Diesel Engine Using Mean Value Model (평균값 모델을 활용한 WGT 디젤엔진의 과급압력 및 EGR율 보정 방법 개발)

  • Chung, Jaewoo;Kim, Namho;Lim, Changhyun;Kim, Deokjin;Kim, Kiyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.3
    • /
    • pp.319-329
    • /
    • 2016
  • Globally, many researchers have been trying to improve the fuel economy of a vehicle for satisfying future $CO_2$ regulation and minimizing air pollution problem. For the same background, diesel engine and vehicle system optimization using simulation models have been key technologies for the improvement of vehicle system efficiency. Therefore, in this study, calibration method for the air breathing system of a WGT diesel engine using mean value model has been composed for efficient engine and vehicle optimization simulation researches. And virtual WGT performances have been calculated for a 2 cylinder downsized diesel engine system. From these researches, the calibration method for the boost pressure and EGR rate of a virtual diesel engine related with WGT performances could be composed and some of technical issue related with downsized diesel engine could be investigated.

Calibration and Radiation Survey of High Dose Rate Remote Afterloading System (고선량율 근접치료기의 선원교정과 치료실주변 방사선량 측정)

  • Lee, Jeon-Gok;Kang, Jeong-Ku;Moon, Sun-Rock
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.101-104
    • /
    • 1995
  • High Dose Rate Remote Afterloading system was installed at Wonkwang University Hospital in January 1994. In this report, the calibration of a Gammamed 12-i High Dose Rate Remote Afterloading system and the radiation survey around the facility after design and construct a shieding room are discussed. The radiation survey of the facility indicates that the use of ordinary concrete shielding of existing room will provide adequate shielding. Also, the methodologies for performing source calibration are presented.

  • PDF

Development and Performance of Automated Calibration System of Sound Level Meters (소음계 교정 자동화 시스템 개발 및 성능평가)

  • 김용태;조문재;이용봉;서재갑
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.879-886
    • /
    • 1998
  • An automated calibration system of sound level meters was developed and tested. As a standard sound source, the speaker unit(Forstex FE208) cabineted by 440$\times$390$\times$490 $\textrm{mm}^3$(LHW) volume wood box was adopted. Including this source, the driving part was found out to have a good linearity of sound pressure output vs AC voltage input. The Hybrid-Bisect/Newton-Raphson method modified by the linearity was adopted as a searching algorithm. Uisng GPIB interface, the console PC make the control, measurements, and calculations and finally make the accumulation of useful data and results automatically by the instructon in the program coded by C languate. Several trials of automatic calibration using this developed system give the reliable results.

  • PDF

A Study on the Camera Calibration Algorithm using the Grid Type Frame with Different Line Widths (다른 선폭들로 구성된 격자형 교정판을 이용한 카메라 교정 알고리즘에 관한 연구)

  • Jeong, Jun-Ik;Han, Young-Bae;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2333-2335
    • /
    • 1998
  • Recently, the development of computer achieves a system which is similar to the mechanics of human visual system. The 3D measurement using monocular vision system must be achieved a camera calibration. So far, the camera calibration technique required reference target in a scene. But, these methods are inefficient because they have many calculation procedures and difficulties in analysis. Therefore, this paper proposes a native method that without reference target in a scene. We use the grid type frame with different line widths. This method uses vanishing point concept that possess a rotation parameter of the camera and perspective ration that perfect each line widths into a image. We confirmed accuracy of calibration parameter estimation through experiment on the algorithm with a grid paper with different line widths.

  • PDF

Fuzzy Methods for the design of Digital Controllers with Intelligent Calibration (지능형 자동 보정화 디지털 제어기 설계를 위한 퍼지 기법)

  • 나승유;박민상
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.187-190
    • /
    • 1998
  • The values of physical components of the plants and controllers as well as the relevant environmental conditions change in time, thus the output performance can be deteriorated during the operating span of the system. Naturally the duty of calibration or the prevention of performance deterioration due to excessive component sensitivity should be provided to the control system. The proposed controller, whenever necessary, measures the open-loop and close-loop characteristics, and then calculates the offset and sensor gain correction values based on the prepared standard measurements It is applied to the control of a flexible link system with the gain and offset calibration problems in the light sensor module for position to show the applicability. In this paper, we propose a digital controller which has the capability of calibration gain and offset adjustment using fuzzy methods.

  • PDF

Automation of Primary Vibration Calibration System Using Laser Interferometer (레이저 간섭계를 이용한 진동 가속도계 절대교정 시스템 자동화)

  • Cho, Seung-Il;Lee, Yong-Bong;Jeon, Byeong-Su;Lee, Jong-Kyu;Lee, Doo-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.11 s.104
    • /
    • pp.1241-1247
    • /
    • 2005
  • An automation of primary vibration calibration system was developed and tested. Using GPIB interface, the console PC make the control of equipments, signal collecting and save measuring results automatically by the instructions in the program by Visual Basic. Several trials of automatic calibration for the accelerometer(ENDEVCO 2270) using this developed system give the reliable results.

Development of a Laboratory-based Calibration System for 5-Hole Probes (5공 프로브 실험실용 교정 시스템 개발)

  • Kim, Changmin;Baek, Seungchan;Ji, Changeun;Hwang, Wontae
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.122-128
    • /
    • 2020
  • In the field of experimental fluid dynamics, the 5-hole probe is one of the most widely used tools to measure flow velocity and pressure. We hereby describe the development of an inexpensive laboratory-based flow calibration system for 5-hole probes. The system is applied to a custom L-shaped probe, and the probe performance is compared against a standard commercial probe in a custom wind tunnel. The setup allows rotation of the probe around the yaw and pitch axes. Static and total pressure values are calculated, and then calibration maps are constructed based on the yaw and pitch angles. Using these maps, errors of the custom probe are found to be ±5% for velocity magnitude and ±3° for direction, compared to the commercial probe, when both pitch and yaw angles are within 40°.

The Development of a Wearable Prototype to Measure Clothing Pressure through Sensor Calibration Procedure

  • Jin, Heejae;Lee, Hyojeong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.827-835
    • /
    • 2022
  • Clothing pressure is considered the essential factor affecting the comfort of clothing, so it is crucial that it is measured precisely. The purpose of this study is to construct a prototype using the Adafruit Flora as the Arduino system, which can be used as a wearable framework for easy, low-cost, and precise clothing pressure measurement. The study also aims to determine how best to conduct the procedure of sensor calibration. To optimize the accuracy of the sensors, the calibration procedure was implemented using mathematical methods that combined polynomial and exponential regression in a hybrid approach. The prototype can easily measure clothing pressure even during active movements, as seen in the detection of stable signals. In addition, since the system was specifically proposed as a wearable patch that can be easily attached and removed as necessary, it can also be used to standardize the value of clothing pressure in each movement.

An Exact 3D Data Extraction Algorithm For Active Range Sensor using Laser Slit (레이저 슬릿을 사용하는 능동거리 센서의 정확한 3D 데이터 추출 알고리즘)

  • Cha, Y.Y.;Gweon, D.G.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.8
    • /
    • pp.73-85
    • /
    • 1995
  • The sensor system to measure the distance precisely from the center of the sensor system to the obstacle is needed to recognize the surrounding environments, and the sensor system is to be calibrated thoroughly to get the range information exactly. This study covers the calibration of the active range sensor which consists of camera and laser slit emitting device, and provides the equations to get the 3D range data. This can be possible by obtaining the extrinsic parameters of laser slit emitting device through image processing the slits measured during the constant distance intervals and the intrinsic parameters from the calibration of camera. The 3D range data equation derived from the simple geometric assumptions is proved to be applicable to the general cases using the calibration parameters. Also the exact 3D range data were obtained to the object from the real experiment.

  • PDF

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF