• 제목/요약/키워드: system area efficiency

검색결과 1,634건 처리시간 0.036초

충진층식 스크러버의 스프레이 시스템 최적 설계에 대한 수치해석적 연구 (NUMERICAL STUDY ON THE OPTIMAL DESIGN OF SPRAY SYSTEM IN PACKED BED SCRUBBER)

  • 고승우;노경철;유홍선
    • 한국전산유체공학회지
    • /
    • 제12권1호
    • /
    • pp.28-34
    • /
    • 2007
  • This study evaluates the performance of the packed bed scrubber and proposes the optimization of spray system for improvements of collection efficiency. The packed bed scrubber is used primarily in the semiconductor manufacturing process. The mean diameter of entering solid particles in scrubber is the submicron. The impaction between water droplets and solid particles is an important factor in removing the solid particles. Thus, the coverage area of spray system influences on the collection efficiency. The collection efficiency of a single droplet is calculated through the mathematical model and numerical calculations are performed for coverage area for each nozzle type (Droplet diameters: 500, 319.5, $289.5{\mu}m$) and injected directions (0, 15, $30^{\circ}$). In case of nozzle type 3, the collection efficiency of a single droplet is highest but the collection efficiency of spray system has lowest value because the ratio of flow rate between the gas and water is below 0.1. The results show the coverage area ratio is about 85% in the case of nozzle type 3 and downward sirection $15^{\circ}$. It was shown that a coverage area increase by two times than an existing spray system. In simulation of demister, collection efficiency by demister is predicted about 80% and the pressure drop in demister is below 3.5 Pa.

Antenna Radiation Efficiency of the Korean NDGPS Based on Radiation Power Measurements

  • Kim, Young-Wan
    • Journal of information and communication convergence engineering
    • /
    • 제10권2호
    • /
    • pp.97-102
    • /
    • 2012
  • The differential global positioning system (DGPS) transmits a GPS enhancement signal using a top-loaded monopole antenna in the medium frequency range. The top-loaded antenna in the medium frequency band can attain a radiation efficiency on the order of 10%. The antenna ground plane characteristics affect the antenna radiation efficiency. To improve the radiation efficiency, it is necessary to install the antenna on a ground plane with large enough physical dimensions and good conductivity. The antenna radiation efficiency is a primary factor in determining the DGPS service area. The service area of the DGPS using a medium frequency band is dominantly affected by the antenna radiation efficiency. To determine antenna radiation efficiencies accurately, the antenna radiation efficiencies of DGPS are deduced from the propagation power in this paper. Based on the deduced antenna radiation efficiencies, the service area for the Korean nationwide-DGPS is analyzed and evaluated.

매니코어 프로세서 상에서 이산 웨이블릿 변환을 위한 성능 평가 및 분석 (Performance Evaluation and Analysis for Discrete Wavelet Transform on Many-Core Processors)

  • 박용훈;김종면
    • 대한임베디드공학회논문지
    • /
    • 제7권5호
    • /
    • pp.277-284
    • /
    • 2012
  • To meet the usage of discrete wavelet transform (DWT) on potable devices, this paper implements 2-level DWT using a reference many-core processor architecture and determine the optimal many-core processor. To explore the optimal many-core processor, we evaluate the impacts of a data-per-processing element ratio that is defined as the amount of data mapped directly to each processing element (PE) on system performance, energy efficiency, and area efficiency, respectively. This paper utilized five PE configurations (PEs=16, 64, 256, 1,024, and 4,096) that were implemented in 130nm CMOS technology with a 720MHz clock frequency. Experimental results indicated that maximum energy and area efficiencies were achieved at PEs=1,024. However, the system area must be limited 140mm2 and the power should not exceed 3 watts in order to implement 2-level DWT on portable devices. When we consider these restrictions, the most reasonable energy and area efficiencies were achieved at PEs=256.

가변 흡기시스템에 의한 디젤기관의 체적효율 향상에 관한 연구 (A Study on the Amelioration of Volumetric Efficiency by Variable Induction System in a Diesel Engine)

  • 강희영
    • 동력기계공학회지
    • /
    • 제10권1호
    • /
    • pp.12-18
    • /
    • 2006
  • A three-degree of freedom model of intake system was contrived and investigated in various ways for the purpose of the amelioration of the volumetric efficiency in a low and transient engine speed for a multi cylinder diesel engine. The basic concept beyond this model started from the theory that each degree of freedom model has volumetric efficiency peak as many as its number of the degree of freedom. The volumetric efficiency affects significantly to the engine performance; torque characteristics, fuel economy and emission level. For commercial vehicles and stationary engines, the engine is designed so as to produce their best performance near the normal engine speeds, thus the low engine speed area has a tendency of poor volumetric efficiency. The aim of this study was highlighted on the amelioration of volumetric efficiency of low engine speed area in a multi cylinder diesel engine matched with an additional Helmholtz resonator. By the use of VIS(variable induction system) volumetric efficiency at low engine speed range was significantly improved. The availability of control by combination of VIS and CIS(conventional induction system) will be proposed as a variable induction system that would be an appropriate model for amelioration of the volumetric efficiency at low engine speed.

  • PDF

High-efficiency deep geological repository system for spent nuclear fuel in Korea with optimized decay heat in a disposal canister and increased thermal limit of bentonite

  • Jongyoul Lee;Kwangil Kim;Inyoung Kim;Heejae Ju;Jongtae Jeong;Changsoo Lee;Jung-Woo Kim;Dongkeun Cho
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1540-1554
    • /
    • 2023
  • To use nuclear energy sustainably, spent nuclear fuel, classified as high-level radioactive waste and inevitably discharged after electricity generation by nuclear power plants, must be managed safely and isolated from the human environment. In Korea, the land area is limited and the amount of high-level radioactive waste, including spent nuclear fuels to be disposed, is relatively large. Thus, it is particularly necessary to maximize disposal efficiency. In this study, a high-efficiency deep geological repository concept was developed to enhance disposal efficiency. To this end, design strategies and requirements for a high-efficiency deep geological repository system were established, and engineered barrier modules with a disposal canister for pressurized water reactor (PWR)-type and pressurized heavy water reactor type Canada deuterium uranium (CANDU) plants were developed. Thermal and structural stability assessments were conducted for the repository system; it was confirmed that the system was suitable for the established strategies and requirements. In addition, the results of the nuclear safety assessment showed that the radiological safety of the new system met the Korean safety standards for disposal of high-level radioactive waste in terms of radiological dose. To evaluate disposal efficiency in terms of the disposal area, the layout of the developed disposal areas was assessed in terms of thermal limits. The estimated disposal areas were 2.51 km2 and 1.82 km2 (existing repository system: 4.57 km2) and the excavated host rock volumes were 2.7 Mm3 and 2.0 Mm3 (existing repository system: 4.5 Mm3) for thermal limits of 100 ℃ and 130 ℃, respectively. These results indicated that the area and the excavated volume of the new repository system were reduced by 40-60% compared to the existing repository system. In addition, methods to further improve the efficiency were derived for the disposal area for deep geological disposal of spent nuclear fuel. The results of this study are expected to be useful in establishing a national high-level radioactive waste management policy, and for the design of a commercial deep geological repository system for spent nuclear fuels.

철전기분해장치(FNR)에서 철판의 표면적이 인제거에 미친 영향에 관한 연구 (A Study on Phosphorus Removal Effects Per Iron Surface Area in FNR Process)

  • 김영규
    • 한국환경보건학회지
    • /
    • 제38권6호
    • /
    • pp.568-574
    • /
    • 2012
  • Objectives: The purpose of this experiment is to understand the phosphorus removal ratio effects of iron plates per unit of surface area through the iron electrolysis system, which consists of an anoxic basin, aerobic basin, and iron precipitation apparatus. Methods: Iron electrolysis, which uses an iron precipitation reactor in anoxic and oxic basins, consisted of iron plates with total areas of 400 $cm^2$, 300 $cm^2$ and 200 $cm^2$ respectively. The FNR process was operated with a hydraulic retention time and a sludge retention time of 12 hours and three days, respectively. Wastewater used in the experiments was prepared by dissolving $KH_2PO_4$ in influent water. Results: The iron plates 400 $cm^2$ (16.6 $mA/cm^2$), 300 $cm^2$ (13.3 $mA/cm^2$) and 200 $cm^2$ (7.3 $mA/cm^2$) in surface area in the phosphorus reactor had respective phosphorus of 2.4 mg/l, 2.7 mg/l and 3.2 mg/l in the effluent and phosphorus removal respective efficiencies of 90.3%, 89.1% and 87.1%. The effluent in the reactor, where the iron plate was not used, had relatively very low phosphorus removal efficiency showing phosphorus concentration of 15.3 mg/l and a phosphorus removal efficiency about 38.3%. Phosphorus removal per ferrous was 0.472 mgP/mgFe in the iron electrolysis system where the surface area of iron was low. Phosphorus pollution load per active surface area and the phosphorus removal efficiency had an interrelation of RE = -0.27LS + 89.0 (r = 0.85). Conclusion: With larger iron plate surface area, the elution of iron concentration and phosphorus removal efficiency was higher. The removal efficiency of phosphorus has decreased by increasing the initial phosphate concentration in the iron electrodes. This shows a tendency of decreasing phosphorus removal efficiency because of decreasing of iron deposition as the phosphorus pollution load per active surface area increases.

EMS data 분석 및 최적화 기법을 적용한 제어지역별 목표운전전압 제안 (Target Operation Voltage Guidelines Considering Voltage Level in Each Voltage Control area by Applying Optimization Technique Through EMS Data Observation)

  • 성웅;김재원;김태균;이병준;정응수;조종만
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.671-678
    • /
    • 2009
  • This paper presents target operation voltage guidelines of each voltage control area considering both voltage stability and economical efficiency in real power system. EMS(Energy Management System) data, Real-time simulator, shows not only voltage level but lots of information about real power system. Also this paper performs optimal power flow calculation of three objective functions to propose the best target operation voltage. objective function of interchange power flow maximum and active power loss minimization stand for economical efficiency index and reactive power reserve maximum objective unction represents stability index. Then through simulation result using optimazation technique, the most effective objective function is chosen. To sum up, this paper divides voltage control area into twelve considering electric distance characteristics and estimate or voltage level by the passage of time of EMS peak data. And through optimization technique target operation voltage of each voltage control area is estimated and compare heir result. Then it is proposed that the best scenario to keep up voltage stability and maximize economical efficiency in real power system.

에너지 효율로 본 상업용 건물의 적정 창호에 관한 연구 (The optimal window system of office buildings considering energy efficiency)

  • 유호천;오영호;박승길
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.53-60
    • /
    • 2005
  • The purpose of this study is to improve energy efficiency of windows in office buildings through the evaluation of their heating, cooling and illumination load. Energy efficiency is influenced by window size which is determined at the early stage of building design. The process of this study is as follows. First, energy performance is analysed according to the various rates of windows through computer simulation (ECOTECT). Then, the annual heating, cooling and illuminating loads according to the different window sizes are compared one another. Results indicated that the optimal window size considering energy efficiency is 50% of the surface area. When the window size is 50% of the surface area, annual maintenance expense is also smallest. Since the cost of cooling is larger than that of heating, too low indoor air temperature in summer is unfavorable based on the reasonable annual maintenance expenses.

Improving water use efficiency in the Upper Central Irrigation Area in Thailand via soil moisture system and local water user training

  • Koontankulvong, Sucharit;Visessri, Supatra
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.8-12
    • /
    • 2022
  • Water loss is one of the typical but challenging problems in water management. To reduced water loss or increase water efficiency, the pilot projects were implemented in the TTD's irrigation area. Modern soil moisture technology and local level water user training were conducted together as a mean to achieve improved water efficiency. In terms of technology, soil moisture sensors and monitoring system were used to estimate crop water requirement to reduce unnecessary irrigation. This was found to save 16.47% of irrigated water and 25.20% of irrigation supply. Further improvement of water efficiency was gained by means of local level water user training in which stakeholders were engaged in the network of communications and co-planning. The lessons learnt from the TTD pilot project was translated into good water management practices at local level.

  • PDF

도시유역의 분담저류 방식에 따른 유출저감특성 분석 (Analysis of Runoff Reduction Characteristics According to Alloted Detention System in Urban Area)

  • 김지태;권욱;김영복;김수전
    • 한국수자원학회논문집
    • /
    • 제39권11호
    • /
    • pp.915-922
    • /
    • 2006
  • 본 연구는 소방방재청에서 계획하고 있는 도시유역의 침수피해를 방지하기 위한 대책 수립의 일환으로 도시유역의 중상류부에 중소규모의 저류지를 설치하는 방안에 대한 유출저감 효과 분석에 관한 것이다. 이를 위해 시범유역을 선정하여 유출분석을 실시하였고 저류지의 위치와 규모에 따른 유출저감 정도 및 치수안전도 확보 효과를 분석하였다. 분석결과 유역의 유출량을 모두 하도에서 소통시키는 개념이 아닌 유역에서 홍수량의 일부를 저류하여 유량을 분담하는 유역분담 저류지를 설치함으로써 하도의 부담을 완화시킬 수 있음을 확인하였고 저류지의 입지 및 규모의 선정에 따라 그 효과에 큰 차이가 있음을 알 수 있었다. 따라서 중상류부에 저류지를 설치하는 경우 하류부 유출 저감에는 상당히 효과적인 것으로 나타나 유역의 치수안전도 확보에 효율적인 방안이 될것으로 기대된다.